Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Similar documents
Tested in accordance with ISO , high expected durability in corrosivity category C5-I. Property Test/Standard Description

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong

Property Test/Standard Description

Pre-qualification testing in accordance with NORSOK M-501, Rev. 5, System 1, suitable for exterior exposure in offshore environment, below 120 C.

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1

Property Test/Standard Description

Property Test/Standard Description

Property Test/Standard Description

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 25 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 32 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Property Test/Standard Description

Approved. Property Test/Standard Description. high gloss (85+) Flash point ISO 3679 Method 1 30 C. US EPA method 24 (tested)

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Property Test/Standard Description. Flash point ISO 3679 Method C

Date of issue: 5 October 2017 Page: 1/6

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method C VOC-EU EU VOC Directive 2004/42/CE (theoretical) 14 g/l

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method C VOC-US/Hong Kong. US EPA method 24 (tested)

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method C VOC-EU EU VOC Directive 2004/42/CE (theoretical) 22 g/l

Technical Data Jotamastic 80 MIO

The required quality of surface preparation can vary depending on the area of use, expected durability and if applicable, project specification.

two component high build amine adduct cured phenolic epoxy primer

SIGMACAP MASTIC GF. September surface tolerant coating for lower grade of steel preparation

PRODUCT GUIDE: ZINC-RICH COATINGS. Version:

Corlar 2.1 PR-P High Solids Productive Epoxy Primer

1.4 kg/l (11.4 lb/us gal) Maximum 295 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) 50 to 63 μm (2.0 to 2.

Refer to Substrates & Surface Preparation.

Aliphatic Acrylic-Polyester Polyurethane

1.4 kg/l (11.4 lb/us gal) Maximum 272 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) To 650 C (1200 F) To 538 C (1000 F)

Corlar 2.1 PR-P High Solids Productive Epoxy Primer For Use With FG-040, FG-041 or FG-042 Activators

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

The Application Guide offers product details and recommended practices for the use of the product.

- Aromatic hydrocarbons - Binder 2,67 kg/dm³ (±0,06 Kg/dm³) Solid content - 80% by weight (±2%) - 58% by volume (±2%) according to ASTM D2697

Corlar 2.8 HG High Solids Epoxy

10P20-14 High Solids Low IR Primer

Coating Types. Coating Systems. Coating Basics. Why coatings are used Component of coatings Methods of protection Service environment

SECTION 1045 PAINT FOR STRUCTURAL STEEL

Corlar LV PR 178 Series Epoxy Primer

PRODUCT DATA SHEET Sika Unitherm Platinum

SP-100 Equipment Wash SP-110 Tool Cleaner

Normadur 65 HS. Technical Data PROPERTIES AND RECOMMENDED USAGE TECHNICAL DATA

SUPERIOR PRODUCTS INTERNATIONAL LEAD-BASED PAINT ABATEMENT ENCAPSULATION METHOD THAT ELIMINATES SANDBLASTING FOR STEEL STRUCTURES

The Application Guide offers product details and recommended practices for the use of the product.

3MTM FireDamTM Intumescent Coating WB Installation Manual. Thinner is. Better

SP-100 Equipment Wash SP-110 Tool Cleaner SP-120 Internal Storage Lubricant

NFCA 400 Field Quality Assurance Procedure for Application of Mastic and Thin-Film Intumescent Fire Resistive Coatings

58 Series Polyurethane topcoat

DP4101 / DP4104 / DP4107 HS PRIMER

64C1-2-A High Temperature Resistant Insulative Coating

Product Information CHEMGLAZE B 9942 A/B. Coating for Casting Pits. Easy Application Chemglaze B 9942 A/B will bond to damp and wet surfaces.

PRODUCT DATA SHEETS CUSTOM COATINGS FORMULATED TO MATCH YOUR NEEDS USCOATINGS.COM // St. Louis, Missouri

Avoiding Fading Paint

Section COATING RESTORATION

CC-1004 Ultra High Temperature Epoxy Adhesive

APPLICATION GUIDELINES EXTERIOR DECK SYSTEM

ERC5 Erosion Resisting Polyurethane Coating

SECTION A. American Society for Testing and Materials (ASTM):

Corrosion, Coatings and Hydropower

HYDROJETTING INFORMATION. a six page issue October 1999

Priming and Painting Slip Critical Steel Connections. Troy Fraebel Corrosion Specification Specialist

Mix ratio (by volume): (base component) (activator component) (thinner component)

APPLICATION GUIDELINES RAPID REPAIR EXTERIOR DECK SYSTEM

Rust Bullet Home and Farm FAQ s

CA8310B (Activator) CA8360 meets the performance requirements of: Mil-PRF FS BS2X34B

Construction. Pulastic Coating-221 W. 2 Component Polyurethane

VE 9300 SERIES NOVOLAC VINYL ESTER

Imron 1.8 FT-C Flat Waterborne Polyurethane Clearcoat

Eclipse ECL-G-2 Clear High Solids Polyurethane Topcoat

HYDRAULIC GATE SEALS. Industrial Rubber Supply (1995) Ltd.

Corrosion Protection for Fisher Valves

1.1 This Section includes surface preparation and the application of base coats, intermediate and topcoats.

Bharat Heavy Electricals Limited Piping Centre Chennai-17. Specification Number Revision Number Sheet Number PC:E:GF: of 7 CONTENTS

10P2-3 Anti-static Conductive Flat Black Epoxy Coating

TECH MANUAL TABLE OF CONTENTS

DPHS521 FL301. Low VOC Primer

SAMPLE SPECIFICATION

Product Information D8120

DULUX INTERIOR LUXURIOUS SILK TECHNICAL DATA SHEET Version SEPTEMBER THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS

Cleaning and Protecting Concrete Surface Preparation, Application, and Inspection. NESMEA October 17, 2017 Kenneth A. Trimber KTA-Tator, Inc.

A. Section includes surface preparation and the application of high-performance coating systems on the following substrates:

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

Construction. 2-part epoxy primer. Product Data

Adhesion Promoter/Primer 3M Adhesion Promoter AP596

Refining Corrosion Technologist NACE-RCT-001

APPENDIX 1 QA INSPECTION FORM - ENVIRONMENTAL READINGS & PAINT/NONSKID STORAGE

Two component solvent-free epoxy system for creation of self-levelling floors. Gloss <4% <70% IR4

SECTION CONCRETE AND MASONRY COATINGS

January 2007 Product Information ENVIROBASE HIGH PERFORMANCE

Single component moisture curing polyureas Best performing corrosion resistant coatings Marine & protective coatings brochure

Florock Seamless Flooring Systems

Frank D. Rea Director of Coatings Services / Chief Chemist

Epobond RS-T30 and RS-T35

GRIP-GARD PLUS BRUSH / ROLL ADDITIVE

TOPCOAT System Specifications Corrugated Transite Panels

Vapor-Clear. The high-performance, low-cost, eco-friendly, aesthetically-pleasing alternative to high-build epoxy floors and boring

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: APPLIED FIREPROOFING REPORT HOLDER: CARBOLINE COMPANY

CHARACTERISTICS / ADVANTAGES. Yellowish-transparent. PACKAGING 20 kg per pail

B. Paints, Sealants, Adhesives

1-part polyurethane pourable self levelling floor joint sealant

Data Sheet 1806 Englisch

Valspar InspireME Coil and Extrusion Product Guide Specification Section Shop-Applied Coatings for Metal

Transcription:

Approved 402;2522 1,2 2522 zinc epoxy ^(ValidationDate) 1 Product description This is a two component polyamide cured zinc rich epoxy coating. It is a high zinc dust containing product. It conforms to the compositional requirements of SSPC paint 20, level 2. It provides very good corrosion protection as part of a complete coating system. To be used as primer in atmospheric environments. Suitable for carbon steel, repair of inorganic zinc silicate coating and damaged galvanized steel substrates. This product complies with ASTM D520 type II zinc dust. Typical use Protective: Suitable for structural steel and piping to be exposed to highly corrosive environments, C5I or C5M (ISO 12944-2). Recommended for offshore environments, refineries, power plants, bridges, buildings, mining equipment and general structural steel. Designed as a primer in coating systems where extended durability is required. Other Colors grey Product data Property Test/Standard Description Solids by volume ISO 3233 53 ± 2 % Gloss level (GU 60 ) ISO 2813 Flash point ISO 3679 Method 1 Density VOC-US/Hong Kong calculated US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong) matt (0-35) 77 F (25 C) 2.2 kg/l Not available. 3.84 lbs/gal The provided data is typical for factory produced products, subject to slight variation depending on color. All data is valid for mixed paint. Gloss description: According to Jotun Performance Coatings' definition. Film thickness per coat Typical recommended specification range Dry film thickness Wet film thickness Theoretical spreading rate 1 mils (25 µm) 1.8 mils (45 µm) 860 ft²/gal (21.2 m²/l) - 3 mils (75 µm) - 6 mils (140 µm) - 290 ft²/gal (7.1 m²/l) Date of issue: 4 March 2018 Page: 1/5

Surface preparation To secure lasting adhesion to the subsequent product all surfaces shall be clean, dry and free from any contamination. Surface preparation summary table Surface preparation Substrate Minimum Recommended Carbon steel St 3 (ISO 8501-1) or SSPC SP-3 Sa 2½ (ISO 8501-1) or NACE No. 2 / SSPC SP-10 Shop primed steel Clean, dry and undamaged approved shop primer (ISO 12944-4 6.1.4) Abrasive swept or alternatively blasted to Sa 2 (ISO 8501-1) or SP 6 / NACE No. 3 (SSPC-VIS 1) of at least 70 % of the surface. Optimum performance, including adhesion, corrosion protection, heat resistance and chemical resistance is achieved with recommended surface preparation. Application Application methods The product can be applied by Spray: Brush: Use airless spray. Recommended for stripe coating and small areas. Care must be taken to achieve the specified dry film thickness. Product mixing ratio (by volume) Comp A Barrier/ Comp B 3 part(s) 1 part(s) Thinner/Cleaning solvent Thinner: Jotun Thinner No. 17 Guiding data for airless spray Nozzle tip (inch/1000): Pressure at nozzle (minimum): 15-21 150 bar/2100 psi Date of issue: 4 March 2018 Page: 2/5

Drying and Curing time Temperatures: -10 C = 14 F / -5 C = 23 F / 0 C = 32 F / 5 C = 41 F / 10 C = 50 F / 15 C = 59 F / 23 C = 73 F / 35 C = 95 F / 40 C = 104 F / 100 C = 212 F Substrate temperature 5 C 10 C 23 C 40 C Surface (touch) dry 50 min 20 min 10 min 4 min Walk-on-dry 3 h 2 h 1.5 h 40 min Dried to over coat, minimum 3 h 2 h 1.5 h 40 min Dried/cured for service 10 d 7 d 5 d 2 d For maximum overcoating intervals, refer to the Application Guide (AG) for this product. Drying and curing times are determined under controlled temperatures and relative humidity below 85 %, and at average of the DFT range for the product. Surface (touch) dry: The state of drying when slight pressure with a finger does not leave an imprint or reveal tackiness. Walk-on-dry: Minimum time before the coating can tolerate normal foot traffic without permanent marks, imprints or other physical damage. Dry to over coat, minimum: The recommended shortest time before the next coat can be applied. Dried/cured for service: Minimum time before the coating can be permanently exposed to the intended environment/medium. Induction time and Pot life Temperatures: 15 C = 59 F / 23 C = 73 F Paint temperature 23 C Pot life 24 h Heat resistance Dry, atmospheric Temperature Continuous 120 C Peak 140 C Peak temperature duration max. 1 hour. The temperatures listed relate to retention of protective properties. Aesthetic properties may suffer at these temperatures. Date of issue: 4 March 2018 Page: 3/5

Product compatibility Depending on the actual exposure of the coating system, various primers and topcoats can be used in combination with this product. Some examples are shown below. Contact Jotun for specific system recommendation. Previous coat: Subsequent coat: inorganic zinc shop primer epoxy, epoxy mastic, polyurethane Packaging (typical) Volume (liters) Size of containers (liters) Comp A 6.75 10 Barrier/ Comp B 2.25 2.25 l = 0.59 gal 6.75 l = 1.78 gal The volume stated is for factory made colors. Note that local variants in pack size and filled volumes can vary due to local regulations. 3 Storage The product must be stored in accordance with national regulations. Keep the containers in a dry, cool, well ventilated space and away from sources of heat and ignition. Containers must be kept tightly closed. Handle with care. Shelf life at 73 F (23 C) Comp A Barrier/ Comp B 24 month(s) 24 month(s) In some markets commercial shelf life can be dictated shorter by local legislation. The above is minimum shelf life, thereafter the paint quality is subject to re-inspection. Caution This product is for professional use only. The applicators and operators shall be trained, experienced and have the capability and equipment to mix/stir and apply the coatings correctly and according to Jotun's technical documentation. Applicators and operators shall use appropriate personal protection equipment when using this product. This guideline is given based on the current knowledge of the product. Any suggested deviation to suit the site conditions shall be forwarded to the responsible Jotun representative for approval before commencing the work. Health and safety Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not inhale spray mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately. Date of issue: 4 March 2018 Page: 4/5

Color variation When applicable, products primarily meant for use as primers or antifoulings may have slight color variations from batch to batch. Such products may fade and chalk when exposed to sunlight and weathering. Disclaimer The information in this document is given to the best of Jotun's knowledge, based on laboratory testing and practical experience. Jotun's products are considered as semi-finished goods and as such, products are often used under conditions beyond Jotun's control. Jotun cannot guarantee anything but the quality of the product itself. Minor product variations may be implemented in order to comply with local requirements. Jotun reserves the right to change the given data without further notice. Users should always consult Jotun for specific guidance on the general suitability of this product for their needs and specific application practices. If there is any inconsistency between different language issues of this document, the English (United Kingdom) version will prevail. Date of issue: 4 March 2018 Page: 5/5