Viking Area of Refuge Signs Designed to Comply with IBC, ADA, NFPA and ICC Requirements

Similar documents
2009 IBC Section 1024 Approved Luminous Egress Path Markings

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

RHE3 Dock Leveler Installation Manual

Model # 800SM-PS3. 8/3/2016 Page 1 of 8

INSTALLATION PROCEDURE

A. This Section includes automatic entrance door systems operating as follows: 1. Swinging operation.

SHCM SHOWER COLUMN INSTALLATION INSTRUCTIONS

SECTION VINYL ACRYLIC CLAD WOOD DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS

Residential Commercial Industrial

Wash Down Duty Non-Contact Sensor

Model # 158-P4. 12/12/2013 Page 1 of 11

4411N 4411G 4412N 4412G

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following:

SECTION DIRECTORIES

Embry-Riddle Aeronautical University Signage Specifications 03/25/2008

OM-90 SERIES Portable Temperature and Humidity Data Loggers. Shop online at omega.com

SERIES W1S & W2S ACCESS COVERS. With Grating Panels

INSTALLATION PROCEDURE

Extreme Sealing Tape

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

Owner s Manual & Safety Instructions

Thank you for purchasing the SC-CONVERSION System 500/600 Conversion Kit. This Kit is available in two different versions:

where high efficiency is the standard

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

Safety Precautions. 3. Cabinet Assembly 4. Operating buttons / functions.5-6. Machine Operation

Double Coated Urethane Foam Tapes

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers)

Model # 922-S4. 12/18/2013 Page 1 of 8

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

Introduction. Disclaimer. Table of contents

SGLP-RO. Installation and Operating Instructions for SCALEGARD TM LP REVERSE OSMOSIS FILTRATION SYSTEM. 3M TM Water Filtration Products

BESTMOVE STANDING TRANSFER AID

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

Double Coated Urethane Foam Tapes

1/17/2005 FAQ - Sothebys doc 1

Wine Storage Models 427G and 427RG Design Guide

INDUSTRIAL GUARDRAIL SYSTEMS

PH6000. Key Features

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

DS-520 Digital Indicator Operation Manual 73366

Bed Docker. Installation Manual. Model BD 600/601

A. Product Data shall be provided for each type of product indicated.

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Architectural Specifications, Section Phenolic Lockers

VI PARTS LIST. , ELECTRIC FRYER PARTS LIST ITEM DESCRIPTION MODELS PART # 10x x24

Gun Safe 6720F / 6740F. Operation & Installation Guide. FIRE 30minutes /1100ºF RATED THEFT. Manual # M

Sby SR Instruments, Inc.

FTW 175 Wireless Monitoring System Reference Manual Part Number

INTERIOR SIGNAGE

SERIES H2R ACCESS COVER With Retro-Grate

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders

Installation and Operation Manual

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

Rack Power Distribution Unit AP7562, AP7563, AP7564 General Information

WHY SPECIFY KOALA: Koala s new KB200 Baby Changing Station has redefined the benefits of Family Friendly accommodation:

RAPiD VEHICLE SAFE. Owner s Manual. Instructional videos for Hornady Security products are available at hornady.com. With patented RFID technology.

PALLET APPLICATION GUIDE

1. Section Steel Doors and Frames. 2. Section Flush Wood Doors 3. Section Aluminum Storefront Doors.

Pedestrian Flood Door

Installation. Basic Rack Power Distribution Units AP9560 AP9561

Owner s Manual & Safety Instructions

Protective Capony RTC-16

SPECIFICATION GUIDE SLIDING CLOSET DOOR PART 1 - PRODUCT

Series - 1

Drag Chain Conveyor Installation and Operation Manual

ON-FLOOR WIREWAY INSTALLATION GUIDE

3 Bumpon TM. Protective Products. Molded Shapes SJ-5000 SJ-5200 SJ-5300 SJ-5400 SJ-5500 SJ-5700 SJ-6100 Series. Technical Data December 1, 1999

DRYWALL DOLLY 900 LB. CAPACITY

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

Insulated Fire-Rated Access Door Model(s): BIT/BIW/BIP

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

Key Features. Glass Locker Series GL5000. ¼ inch tempered glass doors with soft closing hinges. Back-painted glass can be matched to any Pantone color

INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS

This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated by these symbols.

SECTION DEFIBRILLATOR CABINETS

Thermoelectric Cooler

4 rotary milling table

Product Specifications MRI Trench Duct

TOLL FREE: (866) VANITY SPECIFICATIONS. VANITY COMPONENTS Model VG09008

FLEX SHOWER DOOR INSTALLATION INSTRUCTIONS. For more information on DreamLine TM Shower Doors please visit

PS-31 (SUS304, 300 mm) PS-31 (SUS304, 1,000 mm)

3M Decorative Polyester Glass Film

2007 Title 24 Accessibility Code Updates and ADA Issues

Features and benefits. Precision made using cnc machinery to ensure accurate and unobtrusive installation.

Aqua Swing Tub Door & EX/RT Panel

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

Avery Dennison SF 100 Polyester Series Permanent - StaFlat or Kraft Revision: 5 Dated: 01/09/18

Edge Lit. 1 5 Product Data Sheet

RSIC-1. RSIC-1, the Low Cost, High Performance, Noise control Solution. RSIC-1 specifications:

FLEX SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

Maximum Sizes 20 Minute Single : 4 x 9 20 Minute Pair: 8 x 9. Mat formed 32 pound particleboard conforming to ANSI:A208.1 Grade #1-LD

Switch-Tek. LV41 & LV42 Series Manual. Sump Float Level Switches

Maintenance Bypass Breaker Cabinet Series Configuration 5. Installation and Operation Manual

Bottom Hinged Flood Barrier Operation & Maintenance Manual

Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment.

ROLL-IN SHOWER PAN. For additional information, call the Aqua Bath Customer Service Department At

effective January 1 ice storage, ice transport, ice handling EURO LIST PRICE SCHEDULE

BESTMOVE STANDING TRANSFER AID

General Guidelines. Tools Required. Instructions for Part # SC500-AF. Safety

Transcription:

Designed, Manufactured and Supported in the USA VIKING PRODUCT MANUAL COMMUNICATION & SECURITY SOLUTIONS ARS Series Area of Refuge Signs December 28, 2016 Viking Area of Refuge Signs Designed to Comply with IBC, ADA, NFPA and ICC Requirements ARS-DLB100 ARS-TB100 Tactile Blue Braille and raised letter sign to be placed next to the Area Of Refuge (stairwell exit) door. ARS-IB100 Instructional Blue Braille and Raised letter sign to be placed next to the Area of Refuge emergency phone (E-1600A, etc.) The ARS Series Area of Refuge Signs are designed to comply with IBC 1007,1011, ADA 4.3.11, NFPA 22, 101 and ICC 703 code requirements. The ARS-LR100 is an LED Illuminated edge-lit double sided hanging Sign. It is AC powered with 3 hour battery backup. The unit can be ceiling mounted, mounted flat against a wall or end mounted so it can be viewed from either direction. The Instructional, Tactile and Directional signs are made from Acrylic or durable ABS plastic and are designed to adhere to the wall with the provided double sided foam tape. Features Applications ARS-LR100: Red LED edge lit wall sign, 120/277V AC power, Included NiCad battery delivers over 3 hours of battery backup, UL listed, Universal wall, side or ceiling mounting, Silver aluminum housing with mirrored double sided acrylic sign surface, Battery test button, AC pwr LED, Low voltage automatic battery disconnect to prevent deep cycling battery, mounting hardware and 4 optional Chevron arrows with mounting templates included. ARS-TB100: 6 wide x 9 tall Tactile Sign with 0.031 raised white letters and accessibility symbol, California compliant Contracted Grade 2 Braille. Blue PMS 300 Acrylic with non-glare finish, 0.032 thick double sided foam included. ARS-IB100: 6 wide x 7.5 tall Instructional sign with 0.031 raised white Push For Help letters and engraved white text, California compliant Contracted Grade 2 Braille. Blue PMS 294 ABS with non-glare finish, 0.032 thick double sided foam included. ARS-DLB100 (left arrow) and ARS-DRB100 (right arrow): 12 wide x 4 tall Directional sign with engraved white text, Blue PMS 294 ABS with nonglare finish, 0.032 thick double sided foam included. VE-ARSW: Area of Refuge surface mount command center cabinet. Lockable for mounting Two-Way Communications System phone in low rise (less than 60 ft tall) buildings. See DOD# 237. www.vikingelectronics.com Information: (715) 386-8861 ARS-LR100 Lighted double sided Wall or ceiling mount sign to be placed above the Area Of Refuge (stairwell exit) door. ARS-LR100: Placed above Area Of Refuge (stairwell exit) door ARS-TB100: Placed next to Area Of Refuge (stairwell exit) door ARS-IB100: Placed next to Area Of Refuge emergency phone (E-1600A, etc.) ARS-DLB100 and ARS-DRB100: Placed next to exit doors without Area Of Refuge VE-ARSW: Cabinet placed in elevator lobby for mounting command center phone (see DOD # 237) Specifications ARS-DRB100 Directional Blue signs with left or right arrow to be placed next to exit doors without Area Of Refuge. ARS-LR100 Power: 120/277V AC power 3 watts at 120V, 3 hour battery backup, UL 924 compliant Weight: 4.5 lbs. Connections: (3) wire nuts Included Hardware: Wall/ceiling mounting cover, universal electrical box mounting bracket, (2) M4 x 40 Phillips head screws, (2) #10-24 x 0.625 Phillips head screws, (2) #10-24 kepnuts, (4) adhesive backed Chevron arrows ARS-TB100 Material: Acrylic PMS 300 blue with matte finish Dimensions: 6 x 9 x 0.093 Weight: 1.6 oz ARS-IB100 Material: ABS and Acrylic PMS 294 blue with matte finish Dimensions: 6 x 7.5 x 0.093 Weight: 1.6 oz ARS-DLB100 and ARS-DRB100 Material: ABS PMS 294 blue with matte finish Dimensions: 4 x 12 x 0.062 Weight: 3.2 oz VE-ARSW: See DOD# 237

Installation and Specifications A. ARS-LR100 Lighted Double Sided Wall or Ceiling Mount Sign 1. Ceiling Mounting Step 1 Step 2 Plug the remaining holes with appropriate color plug. Attach crossbar to junction box, using junction box screws if needed (not included). Step 3 Remove side plate and open aluminum housing cover, see Figure 1. Step 4 Assemble canopy with aluminum housing, see Figure 3. Using holes 1 and 4 assemble canopy with (2) 10-24 screws and nuts. Step 5 Adhere chevron(s) as required to the panel, then remove the chevron alignment templates. Note: Once chevrons have been attached to the panel, they can be removed but cannot be reused. Step 6 Feed the leads from the circuit board through the center hole. You may use a holding wire, see Figure 4. Step 7 Step 8 Make the proper supply lead connections, see Figure 5. If using 120VAC, connect the black and white leads to the builiding utility. If using 277VAC, connect the orange and white leads to the building utility. Cap off unused wires. Use standard wire nuts when connecting to leads. Using M4 x 40 screws supplied, tighten canopy to mounting plate. Step 9 Connect charge battery wire to circuit board. Step 10 Assemble side plates and close aluminum housing cover, see Figure 2. 2. Side Mounting Step 1 Step 2 Plug the remaining holes with appropriate color plug. Attach crossbar to junction box, using junction box screws if needed (not included). Step 3 Remove side plate and open aluminum housing cover, see Figure 1. Step 4 Assemble canopy with aluminum housing, see Figure 6. Using holes 3 and 5 assemble canopy with (2) 10-24 screws and nuts. Step 5 AAdhere chevron(s) as required to the panel, then remove the chevron alignment templates. Note: Once chevrons have been attached to the panel, they can be removed but cannot be reused. Step 6 Feed the leads from the circuit board through the center hole. You may use a holding wire, see Figure 4. Step 7 Step 8 Make the proper supply lead connections, see Figure 5. If using 120VAC, connect the black and white leads to the builiding utility. If using 277VAC, connect the orange and white leads to the building utility. Cap off unused wires. Use standard wire nuts when connecting to leads. Using M4 x 40 screws supplied, tighten canopy to mounting plate. Step 9 Connect charge battery wire to circuit board. Step 10 Assemble side plates and close aluminum housing cover, see Figure 2. 3. Back Mounting Step 1 Step 2 Plug the remaining holes with appropriate color plug. Attach crossbar to junction box, using junction box screws if needed (not included). Step 3 Remove side plate and open aluminum housing cover, see Figure 1. Step 4 Assemble canopy with aluminum housing, see Figure 3. Using holes 1 and 4 assemble canopy with (2) 10-24 screws and nuts. Step 5 Adhere chevron(s) as required to the panel, then remove the chevron alignment templates. Note: Once chevrons have been attached to the panel, they can be removed but cannot be reused. Step 6 Feed the leads from the circuit board through the center hole. You may use a holding wire, see Figure 4. Step 7 Step 8 Make the proper supply lead connections, see Figure 5. If using 120VAC, connect the black and white leads to the builiding utility. If using 277VAC, connect the orange and white leads to the building utility. Cap off unused wires. Use standard wire nuts when connecting to leads. Using M4 x 40 screws supplied, tighten canopy to mounting plate. Step 9 Assemble aluminum housing to canopy using provided screws, see Figure 7. Step 9 Connect charge battery wire to circuit board. Step 10 Assemble side plates and close aluminum housing cover, see Figure 2. 2

3

B. ARS-TB-100 Blue Tactile Braille Sign 6.00 1. Literary braille type: Raster TM Contracted Grade 2 with.059 dot base diameter,.10 inter dot spacing, inter-cell spacing =.20,.025 dot height. (Rounded on top). California Title 24 compliant. 2. Material: Single Ply Modified Acrylic 3. Adhesive: 0.032" thick 3M 4462B double coated polyethylene foam with 745 rubber adhesive 4. Font: Arial Bold 5. Background: Blue PMS 300 matte non-glare finish 6. Text and Graphics: PMS trans. white 7. Usage: Interior signage and/or exterior signage 8. Thickness: 1/16 (0.0625 ) 9. Edges: Beveled 10. Durability: UV stable, handles temperatures up to 175 F 9.00 Raised 0.031 Min. 0.625 0.375 4 ARS-TB100 Mounting Height and Location to Comply with ICC (Internation Code Council) 2009 703.3.10 Height above Floor. Raised characters shall be 48 inches (1220mm) minimum above the floor, measured to the baseline of the lowest raised character and 60 inches (1525mm) maximum above the floor, measured to the baseline of the highest raised character. 703.3.11 Location. Where a sign containing raised charachers and braille is provided at a door, the sign shall be alongside the door at the latch side. Where a sign containing raised characters and braille is provided at double doors with one active leaf, the sign shall be located on the inactive leaf. Where a sign containing raised characters and braille is provided at double doors with two active leaves, the sign shall be to the right of the right-hand door. Where there is no wall space on the latch side of a single door, or to the right side of double doors, signs shall be on the nearest adjacent wall. Signs containing raised characters and braille shall be located so that a clear floor area 18 inches (455mm) minimum by 18 inches (455mm) minimum, centered on the raised characters is provided beyond the arc of any door swing between the closed position and 45 degrees open position.

C. ARS-IB-100 Blue Instructional Braille Sign 6.00 1. Literary braille type: Raster TM Contracted Grade 2 with.059 dot base diameter,.10 inter dot spacing, inter-cell spacing =.20,.025 dot height. (Rounded on top). California Title 24 compliant. 2. Material: 2-Ply Micro Surfaced ABS and 1-Ply modified Acrylic. 3. Adhesive: 0.032" thick 3M 4462B double coated polyethylene foam with 745 rubber adhesive 4. Font: Arial Bold 5. Background: Pantone blue 294, matte finish 6. Text and Graphics: PMS trans. white 7. Durability: UV stable, handles temperatures up to 175 F 7.50 D. ARS-DLB100 Blue Left Arrow Directional Sign 12.00 0.375 PUSH FOR HELP LOCATION Persons able to use the exit stairway do so as soon as possible, unless they are assisting others. After activating the Area of Refuge communication system, wait here for assistance. VIKING FLOOR 0.625 0.65 4.00 1. Material: 2-ply microsurfaced ABS 2. Adhesive: 0.032" thick 3M 4462B double coated polyethylene foam with 745 rubber adhesive. 3. Font: Arial Bold 4. Background: Blue PMS 294 matte non-glare patterened finish 5. Text and Graphics: PMS trans. white 6. Usage: Interior signage 7. Thickness: 1/16 (.0625 ) 8. Edges: Straight 9. Durability: UV stable, handles temperatures up to 175 F E. ARS-DRB100 Blue Right Arrow Directional Sign 12.00 0.65 4.00 1. Material: 2-ply microsurfaced ABS 2. Adhesive: 0.032" thick 3M 4462B double coated polyethylene foam with 745 rubber adhesive. 3. Font: Arial Bold 4. Background: Blue PMS 294 matte non-glare patterened finish 5. Text and Graphics: PMS trans. white 6. Usage: Interior signage 7. Thickness: 1/16 (.0625 ) 8. Edges: Straight 9. Durability: UV stable, handles temperatures up to 175 F 5

VIKING EMERGENCY PHONE HELP Application Examples Requirements for INSIDE the Area of Refuge Two-Way Communications Instructional Signage LOC TION Requirements for OUTSIDE the Area of Refuge Directional Signage Model 1600A Series Persons able to use the exit stairway do so as soon as possible, unless they are assisting others. After activating the Area of Refuge communication system, wait here for assistance. Model ARS-IB100 Model ARS-DLB100 (Left arrow) Model ARS-DRB100 (Right arrow) Illuminated Signage Model ARS-LR100 Tactile Signage Model ARS-TB100 Requirements for the Area of Refuge Lobby Command Center Two-Way Communications System As required by the following codes: IBC 1007, 1011 ICC 703 NFPA 22, 101 ADA 4.3.11 Area of Refuge Command Center (phone in locked cabinet located in the elevator lobby*) Refuge Locking Command Center Enclosure Model VE-ARSW (surface mount) * For buildings under 60 ft. For taller buildings, the Refuge Command Center phone should be located in the Fire Command Center. Recommendations for 6 or Less Area of Refuge Emergency Phones Recommendations for 7-24 Area of Refuge Emergency Phones High Efficiency UPS (Tripp-Lite model Internet55U or equivalent) 6 Port Line Concentrator Model LC-6 High Efficiency UPS (Minuteman Entrust Series ETR700 or equivalent) Panasonic KX-TA824 120V AC 120V AC Connect up to 6 Area of Refuge emergency phones (1600A Series) to one command center phone and one C.O. line. UPS must have a minimum of 90 minute backup. Using a Panasonic KX-TA824 with optional expansion cards KX-TA82483 and KX-TA82470, connect up to 24 Area of Refuge emergency phones (1600A Series) to one command center phone and one C.O. line. UPS must have a minimum of 90 minute backup. Note: The Panasonic KX-TA824 can be expanded (in increments of 6) up to 144 ports by adding a Viking LC-6 to each station port. 6

Related Products A. Model VE-ARSW Area of Refuge Surface Mount Command Center Cabinet Each Area of Refuge is required to have a central control point (Command Center) where the emergency phones call for assistance. In low rise buildings (less than 60 ft. tall) the Command Center can simply be a telephone mounted in a cabinet located on the ground floor of the elevator lobby. The VE-ARSW cabinet is ideal for this application, allowing you to mount a single line phone or PABX Key phone. The VE-ARSW is a 13 x 13.5 x 4 surface mount metal cabinet with a hinged door, roller catch, chrome handle, phone mounting studs and optional lock. The lock is equipped with a breakaway cam allowing emergency personnel to force the door open if the key cannot be found. Features 20 gauge galvaneal steel cabinet with gloss white powder coat finish Optional roller catch to keep door closed when not using the lock Lock with breakaway cam and two keys Heavy duty chrome plated cast handle Mounting studs on back panel for mounting any standard wall phone Hinged door with clear acrylic window For more info see DOD# 237 Specifications Material: 20 gauge galvaneal steel Finish: Gloss white powder paint Dimensions: 13 x 13.5 x 4 (330.2mm x 342.9mm x 101.6mm) Weight: 8.0 lbs (3.63 kg) B. Model LC-6 Concentrates up to Six Area of Refuge Emergency Phones The LC-6 Line Concentrator eliminates the monthly charges for a dedicated line to each Area of Refuge. The LC-6 is designed to be used with the Viking 1600A Series Emergency Phones. Up to six of these emergency phones can communicate with authorized personnel on 3 other phones within a building, or add a telephone line to allow communication outside the building. A call initiated by an emergency phone can dial internally, externally, or both. Any other phones that are activated will be bridged with authorized personnel. All telephone line inbound calls are answered by the For more info see DOD# 245 LC-6. A touch tone command will route the call to any of the phone ports. If no command is detected within 4 seconds, the call will be routed to the last emergency phone that was used. This allows emergency personnel to easily call back to the same phone. Connections include a Fire Floor phone, a Machine Room phone and a Lobby phone. An output is also provided for driving up to two Viking LM-24D displays to show status of all ports. 7

C. Your Emergency Device Can Share a Line with You Phone System Why pay for a dedicated line for your elevator/emergency phone or alarm panel? The LSR-1 Line Seizure Relay allows the user to share an existing phone line with an emergency phone or other priority alarm device. This can save hundreds of dollars a year over leasing a dedicated phone line. The LSR-1 can be used on any C.O. line or analog PABX/KSU station. Important: When the emergency device is in use, the phone line is not available for normal use. Any additional emergency calls will have to be made on another phone line. For this reason the LSR-1 is not recommended for single line applications. Note: Connecting more than one set of microphone and speaker combinations to the LSR-1 may infringe on US Patent 5,386,463. For more info see DOD# 230 Warranty IF YOU HAVE A PROBLEM WITH A VIKING PRODUCT, CONTACT: VIKING TECHNICAL SUPPORT AT (715) 386-8666 Our Technical Support Department is available for assistance Monday through Friday 8am - 5pm central time. So that we can give you better service, before you call please: 1. Know the model number, the serial number and what software version you have (see serial label). 2. Have your Product Manual in front of you. 3. It is best if you are on site. RETURNING PRODUCT FOR REPAIR The following procedure is for equipment that needs repair: 1. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (RA) number. The customer MUST have a complete description of the problem, with all pertinent information regarding the defect, such as options set, conditions, symptoms, methods to duplicate problem, frequency of failure, etc. 2. Packing: Return equipment in original box or in proper packing so that damage will not occur while in transit. Static sensitive equipment such as a circuit board should be in an anti-static bag, sandwiched between foam and individually boxed. All equipment should be wrapped to avoid packing material lodging in or sticking to the equipment. Include ALL parts of the equipment. C.O.D. or freight collect shipments cannot be accepted. Ship cartons prepaid to: Viking Electronics, 1531 Industrial Street, Hudson, WI 54016 3. Return shipping address: Be sure to include your return shipping address inside the box. We cannot ship to a PO Box. 4. RA number on carton: In large printing, write the R.A. number on the outside of each carton being returned. RETURNING PRODUCT FOR EXCHANGE The following procedure is for equipment that has failed out-of-box (within 10 days of purchase): 1. Customer must contact Viking s Technical Support at 715-386-8666 to determine possible causes for the problem. The customer MUST be able to step through recommended tests for diagnosis. 2. If the Technical Support Product Specialist determines that the equipment is defective based on the customer's input and troubleshooting, a Return Authorization (R.A.) number will be issued. This number is valid for fourteen (14) calendar days from the date of issue. 3. After obtaining the R.A. number, return the approved equipment to your distributor, referencing the R.A. number. Your distributor will then replace the Viking product using the same R.A. number. 4. The distributor will NOT exchange this product without first obtaining the R.A. number from you. If you haven't followed the steps listed in 1, 2 and 3, be aware that you will have to pay a restocking charge. TWO YEAR LIMITED WARRANTY Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of two years from the date of purchase from any authorized Viking distributor. If at any time during the warranty period, the product is deemed defective or malfunctions, return the product to Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI., 54016. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (R.A.) number. This warranty does not cover any damage to the product due to lightning, over voltage, under voltage, accident, misuse, abuse, negligence or any damage caused by use of the product by the purchaser or others. This warranty does not cover non-ewp products that have been exposed to wet or corrosive environments. This warranty does not cover stainless steel surfaces that have not been properly maintained. NO OTHER WARRANTIES. VIKING MAKES NO WARRANTIES RELATING TO ITS PRODUCTS OTHER THAN AS DESCRIBED ABOVE AND DISCLAIMS ANY EXPRESS OR IMPLIED WAR- RANTIES OR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. EXCLUSION CONSEQUENTIAL DAMAGES. VIKING SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE TO PURCHASER, OR ANY OTHER PARTY, FOR CONSEQUENTIAL, INCI- DENTAL, SPECIAL OR EXEMPLARY DAMAGES ARISING OUT OR RELATED TO THE SALE OR USE THE PRODUCT SOLD HEREUNDER. EXCLUSIVE REMEDY AND LIMITATION LIABILITY. WHETHER IN AN ACTION BASED ON CONTRACT, TORT (INCLUDING NEGLIGENCE OR STRICT LIABILITY) OR ANY OTHER LEGAL THEORY, ANY LIABILITY VIKING SHALL BE LIMITED TO REPAIR OR REPLACEMENT THE PRODUCT, OR AT VIKING'S OPTION, REFUND THE PURCHASE PRICE AS THE EXCLUSIVE REMEDY AND ANY LIABILITY VIKING SHALL BE SO LIMITED. IT IS EXPRESSLY UNDERSTOOD AND AGREED THAT EACH AND EVERY PROVISION THIS AGREEMENT WHICH PROVIDES FOR DISCLAIMER WARRANTIES, EXCLUSION CONSEQUENTIAL DAMAGES, AND EXCLUSIVE REMEDY AND LIMITATION LIABILITY, ARE SEVERABLE FROM ANY OTHER PROVISION AND EACH PROVISION IS A SEPARABLE AND INDEPENDENT ELEMENT RISK ALLOCATION AND IS INTENDED TO BE ENFORCED AS SUCH. Product Support: (715) 386-8666 Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes. 8 DOD# 235 Printed in the U.S.A. ZF303460 Rev A