Gerber M Series Site Requirements

Similar documents
Pre-installation Manual LightCELL Advanced Laser Machining Center

Pre-installation Manual CONCEPT 301 D/401 D/501 D

BINAR Quick-Lift System

MNL, SEL DIMENSIONS, SITE AW PLANNING GUIDE ARTWORK SIZE A SHEET 1 OF 1

Gerber CAT UV. Site Requirements, Operating Performance Requirements and Warranty Limitations

INSTALLATION INSTRUCTIONS CMP SERIES

medixx Series Installation Guidelines medixx 50 medixx 60 medixx 70 Suitable for the following Siemens MRI Systems, or similar models:

Electric Service Standards

Lubricated Rotary Screw Air Compressors. Constant Speed Drives and Variable Speed Drives kw hp

METHOD OF PAYMENT. Advance Payment Deadline Date: 02/09/18 FINANCIALLY RESPONSIBLE COMPANY METHOD OF PAYMENT CHECK AND CREDIT CARD INFORMATION

PROflex* 60 Hz Reverse Osmosis Machines from 50 to 360 gpm

all VAC LIFT ALL-VAC-LIFT Phone Redstart Street Fax

UNDERGROUND SERVICES SECONDARY

Maintenance Bypass Breaker Cabinet Series Configuration 5. Installation and Operation Manual

Light Duty Ramps. Loadingdocksupply.com PHONE:

Pre Delivery & Installation Guide GX 480 GX 480 DT GX 480 APC GX 480 DT APC GX 600 GX 800 GX 1000

PROPOSAL FOR MODEL: HP 2100X

MODELS PH PH PH

Basic Service. This Section provides information regarding a. Introduction

300828TWP INSTALLATION INSTRUCTIONS MODEL SUBMERSIBLE SUMP PUMP

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

Kelley HULK Dock Lifts and Ergonomic Lift Tables

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SC Series Modular Reverse Osmosis System. January 2012 Version

3M Intelligent Return Plus and Sorter System SL. Architect/Contractor's Package

Diffused Aeration Piping Equipment

Installation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02

Vertical Baler: V63OCC

MD Power Supply -48Vdc +Bias Tee

YOUR SPLASH PAD RESOURCE

NEUTRAL GROUNDING TRANSFORMERS INSTALLATION AND MAINTENANCE INSTRUCTIONS

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

LEED FOR BUILDING OPERATIONS AND MAINTENANCE (LEED O+M) v4 DOCUMENTATION LETTER FOR UNITED STATES OF AMERICA

Utah s APWA Fall Conference and Stormwater Expo October 11 and 12, 2016 South Towne Exposition Center

SECTION SLUDGE HOLDING TANK DECANTER PUMP

MET-FAB FABRICATION & MACHINE, INC. P.O. Box 363, Batavia, Ohio Ph. (513) Fax (513)

VARIETY BEAUTY COMES IN ALL SHAPES AND SIZES SERVICE SELF-SERVICE COMBINATION

(01) Thermo Bond Buildings Military Service Shelter: DOG KENNEL OPERATING AND SETUP MANUAL MSS-RP-1-20P

July P Wide Format Stacker User Guide

FREQUENTLY ASKED QUESTIONS FOR THE ADVANTAGE

FREEMAN installation & dismantle

VIBRAPAC 3 AT A TIME INSTALLATION MANUAL F9801US OCTOBER 1999 US$250

Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment.

SECTION PACKAGE BOOSTER PUMP STATIONS

COMPACT FIRE PUMP SYSTEM LIFTING MANUAL LIFTING & MOVING INSTRUCTIONS

Natural Gas Service Installation and Meter Clearance Requirements

Filter Media 452 sq. ft. (42 sq. m) Accu-Rated Airflow 900 cfm (425 L/sec.) Sound Level Approximately 77 dba at 5 ft. (1.5 m)

SECTION CHAIN-LINK FENCES AND GATES 02821/1

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

INSTALLATION INSTRUCTIONS

BakeMax Dough Mini Moulder BMMDM02

Legacy Environmental Process, LLC 1445 Ashville Road, Suite 103 Leeds, Alabama In USA Fax:

Raised Basement. Mechanical Installation Guide

Introduction. Disclaimer. Table of contents

SURFACE TEMPERATURE SENSORS

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

Sprinkler Identification Numbers (SINs)

Installation and Operation Manual

Xerox Nuvera Xerox Production Stacker Operator Manual

Material Handling. Chapter 5

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

trusted innovative expertise

S E R I E S Series Design & Installation Guide. September 2014

Westgate Entrematic, Parking Security Gates Section OVERHEAD SECURITY GATE Prepared by: Digicon Information Inc. Page 1

Installation plan. Washer-extractor PW 6107 EL. en - GB M.-Nr / 01

TYPICAL INSTALLATION INSTRUCTIONS

PRE-INSTALLATION MANUAL. February 2015

Material Handling Comparison

a difficult challenge when trying to achieve effective coverage within a shallow space. The Model CC1 Combustible

Power Zone Center. Your solution for power distribution and control systems

Official General Contractor. Show Information

A-Series Aluminum Gantry Crane

Sby SR Instruments, Inc.

Smarter. Safer. Leaner.

Bulk Bag Unloader Installation, Operation and Maintenance Manual

TABLE OF CONTENT. Equipment kit Description of the technology Installation of equipment Start of construction...

FERTILIZER IRRIGATION EQUIPMENT LTD. SERIES 6000 APPLICATIONS

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Compressed Air Systems. Compressed Air Filters. Balston Microfiber Filter Assemblies. Product Features

(Condensed from National Electric Code)

Wireless Freezer Manual Installation Guide

BULK BAG FILLING SYSTEMS

Revision 1 RAM ELEVATORS. Elevator Electrical Planning Guide. RAM Manufacturing Ltd

Speedlock Pallet Racking

The Canadian Electrical Code (Saskatchewan Amendments) Regulations, 1999

Section 13 Lift-Position Units

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

TC54. for architects & designers. Dimensions Clearances Venting

Fiberglass Cooling Towers

DESIGN AND CONSTRUCTION STANDARDS. Section 2: Standards for Specific Categories of Work. Laboratory Standards

Site Preparation Guide. Stratasys J750 3D Printing System. DOC Rev. D1

A. STORAGE/ WAREHOUSE SPACE

CONSTRUCTION TRADES LABORATORY September 30, 2010

ANSI/ ASME HST Performance Standard For Overhead Electric Wire Rope Hoists

SECTION COOLING TOWER

Product Specifications MRI Trench Duct

For the 2008 Code, the minimum clear distances were revised to reflect an accurate metric conversion (also known as a soft conversion).

Series Sump and Sewage Systems

METHOD OF PAYMENT FORM

Multi-Level VW Piezometer

Transcription:

Gerber M Series Site Requirements Preparing for the arrival of your new machine. P rior to the arrival of your Gerber M Series Cutting System there are certain things you can prepare to facilitate a quick and smooth installation. The following information will guide you. It is also important that you complete the Site Preparation and Warranty Checklist (the last page of this document) and return it to Gerber Sales Support so that they can schedule the installation of your cutting system. Floor Plan Preparation Electrical Inputs and Connections Vacuum Blower Shipping and Handling Site Preparation Checklist Floor Plan Refer to Appendix A Floor Plan for the dimensions of the machine and necessary clearances. Preparation Allow sufficient room for operator access and work handling. Vacuum, electrical and pneumatic connections are most conveniently attached at the rear and to the left of the machine. Clean and wax the floor if appropriate. To avoid static electricity, which can interfere with computer operations, carpets are not recommended. Isolation of machine by partitions or windowed walls should be considered, as the machine generates noise that may be distracting to CAD personnel.

External Inputs and Connections Setup requirements 90psi air at 6 SCFM, filtered to 5 microns. Minimum 3hp. 2 dedicated 110 power outlets rated for 20 amps with no extension cables. 3 phase 35amp power for blower Motor starter for blower (manual or magnetic starter) Vacuum Blower Prior to delivery of your machine, the vacuum blower should be shipped to you. The blower must be installed as close to the machine as is practical. The blower is to be mounted on the supplied rubber shock mounts. Do not bolt directly to a floor as this can distort the blower housing. The blower may be mounted vertically or horizontally on a wall, or suspended from a roof. The maximum allowable ambient temperature is 100 degrees F (38 C). The blower has a high airflow and produces considerable heat and noise, even with the supplied muffler. Four-inch PVC piping must be run between the vacuum blower to within six feet of the rear of the Cutting Table. Try to minimize the use of 90-degree elbows to minimize flow losses. Reduce to a 2 ½" NPT female thread at each end. Gerber supplies 2 ½" NPT barbed fittings and flexible hose to connect the blower and machine to the 4" PVC. Contact customer service to be sure the vacuum pump is shipped early. The motor starter is customer-supplied and must be wired in conformance with local electrical codes. The start/stop switch should be mounted near to the front left of the Cutting Table. Automatic Blower Operation Note that if you would like to use a magnetic starter as opposed to a manual starter, provision is made inside the Gerber controller to pilot the starter. We provide a normally open set of relay contacts and two terminals for field hookup. The vacuum blower can then be automatically controlled by the cutting system. Pneumatic A 90 PSI @ 6 SCFM pneumatic supply is required for the machine. The air quality should be clean, dry, and filtered to 5 microns. A male & female quick disconnect fitting is supplied with the machine. The barb fitting is for 5 / 16 " ID hose. The connection on the Cutting Table is in the left rear of the base. Piping runs over 50 feet long should use ¾" or larger piping. A drip leg and coalescing filter should provide sufficient quality. Dryers may be required on pneumatic systems that produce more water than a coalescing filter can accommodate.

If your existing air system lacks sufficient capacity, a compressor will be required. The minimum acceptable size is 3 HP. You will have to provide filtration and possibly a drier to meet the above air quality requirements. Electrical Table 1 shows the electrical requirements for the 10 HP vacuum blower. 10 HP Vacuum Blower Electrical Requirements HP/kW 60 Hz 10/7.5 50 Hz 8/6 Voltage 60 Hz 208-230/460-3 50 Hz 190-220/380-440-3 Amps 60 Hz 35-29.5/15 50 Hz 27-23/13.5-12.3 Starting Amps 60 Hz 120 @ 460V 50 Hz 143 @ 380V Insulation Class F Recommended NEMA Starter Size 2/1 Net Weight (lbs/kg) 293/133 Table 1 Electrical Customer must provide service per local code. The machine requires a dedicated 20 AMP circuit at 115V/60 Hz. An equivalent 50 Hz. power source may be used if the factory is notified at the time of order. Note that on a nominal 115V USA installation, the line voltage must be in the range of 110V to 122V for proper operation of the machine. The service outlet should be within 4 feet of the left rear of the machine. The machine must not be run through an extension cord. Network A network cable is desirable for connection between the Cutting Table and the CAD computer. If no network exists or if no connection is setup, a disk must be used to transfer substrate files from the CAD computer to the Cutting Table.

Vacuum Blower Dimensions Figures 2 shows the dimensions of the vacuum blower supplied with your Cutting Table. Shipping and Handling Figure 1 10 HP Vacuum Blower Access During installation, large machine parts will need to be moved into final position. Any large objects in the work area should be moved out of the way prior to installation. Arrival Refer to Appendix B Shipping Crate for the dimensions of the shipping crates. The M1200 is shipped fully assembled. Refer to Appendix A Floor Plan to determine if the machine will fit through any doors or elevators to get to the final location. If the machine will not fit then it will need to be disassembled and moved in pieces. The service technician will require help during this process. Note that the vacuum pump skid is usually shipped early. Labor requirements: Two people, each capable of lifting 50 lbs. (23 kg) must be available to assist the technician on the first day of installation. It is the customer's responsibility to ensure that these people are on hand. If on-site staff is not available, contact local temporary agencies or moving companies to hire them.

With any other machine except the M1200, four persons can handle the major assemblies, all of which break down into sub-assemblies weighing 250 or less. Loading Dock The availability of a loading dock will determine what type of truck is used. Please inform Gerber of this in advance of installation. Fork Lift A forklift is desirable but not necessary. A pallet and hand-operated jack and dollies are necessary. Uncrating Wait for Gerber Service personnel before uncrating. Tools When installing the machine, Gerber Service personnel will need access to the following: 1. Claw hammer 2. Pry bar 3. 3/8" reversible/variable speed pistol drill 4. Extension cord 5. Fantastic or another general purpose cleaner 6. Cloth rags 7. Spray can of 10-weight oil 8. Vacuum cleaner

Appendix A Floor Plan Floor Plan Recommended Width x Depth Total Clearance M1200 94 x 76 154 x 164 M3000 103 x 151 163 x 239 (All units are in inches)

Appendix B Shipping Crate Dimensions Length x Width x Height (Weight) M1200 Crate Base* 81 x 98 x 67 (1500 lbs.) Crate Surface Crate Cross Beams Crate Gantry Skid Vacuum Pump N/A N/A N/A 36 x 36 (250 lbs.) M3000 28 x 103 x 32 (800 lbs.) 51 x 84 x 22 (1070 lbs.) 31 x 152 x 29 (920 lbs.) 35 x 106 x 29 (920 lbs.) 36 x 36 (250 lbs.)

Site Preparation and Warranty Checklist In order to expedite the Gerber M Series installation, complete this checklist and fax it Gerber Sales Support at 800-227-6228. Description Power requirements for the Gerber M Series: Cutter: Two 20 AMP circuits at 115V/60 Hz. Line voltage must be in the range of 110V to 122V for proper operation of the machine. Machine MUST NOT be run through an extension cord.(see page 3 for details) Blower: 3 phase, 35amp, 60Hz power for blower (See page 3 for details.) Motor starter for blower (manual or magnetic starter) must be installed by licensed electrician. A licensed electrician will install the proper electrical service prior to the arrival of the cutting table. Compressed air requirements 90psi air at 6 SCFM, filtered to 5 microns. Minimum 3hp. Weight and clearance requirements for M3000 Series Cutting Table: Does not have a loading dock but has a forklift to take the Gerber M3000 Series crates (maximum weight ~1,000 lbs. (454kg)) off the carrier s truck. Has a loading dock and a forklift or pallet jack to take the Gerber M3000 Series crates (~1,000 lbs. (454kg)) off the carrier s truck. Does not have a dock or a forklift or pallet jack and will hire riggers to facilitate the delivery and installation of the Gerber M3000 Series cutting table. The outside doorway into the facility is at least 53" (135cm) wide. Interior corridors and doorways are at least 53" (135cm) wide. (Wider widths are needed for turning radius) Weight and clearance requirements for M1200 Series Cutting Table: M1200 Cutting Table ships assembled. If doorway clearances are not sufficient, the table must be disassembled and moved in pieces. The Gerber service technician will require assistance. Does not have a loading dock but has a forklift to take the Gerber M1200 Series crate (1,500 lbs. (680kg)) off the carrier s truck. Has a loading dock and a forklift or pallet jack to take the Gerber M1200 Series crate (1,500 lbs. (680kg)) off the carrier s truck. Does not have a dock or a forklift or pallet jack and will hire riggers to facilitate the delivery and installation of the Gerber M1200 Series cutting table. The outside doorway into the facility is at least 82" (208cm) wide. Interior corridors and doorways are at least 82" (208cm) wide. (Wider widths are needed for turning radius) General delivery requirements: The path from the loading dock to the printer's permanent location is free and clear of obstructions. Business location/area. Residential location/area. Labor requirements: Two people capable of lifting 50 lbs. (23 kg) will be on hand to assist the technician on the first day of installation. Work area and operating requirements: Has sufficient work area clearance on all sides of the printer as shown on in Appendix A. The floor is level and free of debris. There is a clean area for storage of media. Media should not be stored on the floor. Will store the shipping crates in its original condition for use during reshipment. Warranty acceptance: I have read and understand the Gerber M Series warranty and accept the terms and conditions. Complete Customer Name: Signature: Title: Date: Company name: Phone: Service Technician Name: Signature: