The clearly better choice

Similar documents
Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

HIGHER IMPACT LC/MS DIAGNOSTICS AGILENT IN VITRO DIAGNOSTIC MEDICAL DEVICES FOR CLINICAL LABORATORIES

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment QTRAP 5500

AB SCIEX TripleTOF 5600 SYSTEM. High-resolution quant and qual

Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions

LC/MS/MS Solutions for Biomarker Discovery QSTAR. Elite Hybrid LC/MS/MS System. More performance, more reliability, more answers

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides

rapiflex Innovation with Integrity Designed for Molecules that Matter. MALDI TOF/TOF

Thermo Scientific TSQ Quantum Access MAX

Agilent 6400 Series. System. Concepts Guide. The Big Picture. Agilent Technologies

Highly Confident Peptide Mapping of Protein Digests Using Agilent LC/Q TOFs

Thermo Scientific Peptide Mapping Workflows. Upgrade Your Maps. Fast, confident and more reliable peptide mapping.

Peptide Mapping of Glycoprotein Erythropoietin by HILIC LC/MS and RP-LC/MS

CaptiveSpray nanobooster

Agilent 7820A GC System THE EASY CHOICE FOR ROUTINE ANALYSES

ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS

The LC-MS/MS Workhorse. SCIEX 4500 Series Mass Spectrometers

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

Cell Clone Selection Using the Agilent Bio-Monolith Protein A Column and LC/MS

Featuring Analyst software under Windows NT for enhanced performance and ease of use. API 150EX. LC/MS System

ICP Expert software. Technical Overview. Introduction

Agilent 7693A Series Automatic Liquid Sampler. Inject new performance into your gas chromotography

Characterization of Glycosylation in the Fc Region of Therapeutic Recombinant Monoclonal Antibody

Monoclonal Antibody Characterization on Q Exactive and Oribtrap Elite. Yi Zhang, Ph.D Senior Proteomic Marketing Specialist Oct.

TurboMass GC/MS Software

Characterize Fab and Fc Fragments by Cation-Exchange Chromatography

MasterView Software. Turn data into answers reliable data processing made easy ONE TOUCH PRODUCTIVITY

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Xevo G2-S QTof and TransOmics: A Multi-Omics System for the Differential LC/MS Analysis of Proteins, Metabolites, and Lipids

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Rapid Peptide Catabolite ID using the SCIEX Routine Biotransform Solution

Proteins. Patrick Boyce Biopharmaceutical Marketing Manager Waters Corporation 1

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

Agilent 1220 Infinity II LC GET ON THE FAST TRACK TO HIGHEST EFFICIENCY AT A PRICE YOU CAN AFFORD

Application Note. Author. Abstract. Biotherapeutics and Biologics. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany

Method Translation in Liquid Chromatography

Rapid Soft Spot Analysis using the SCIEX Routine Biotransform Solution

BioConfirm B Presentation

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

Metabolic Changes in Lung Tissue of Tuberculosis-Infected Mice Using GC/Q-TOF with Low Energy EI

A Unique LC-MS Assay for Host Cell Proteins(HCPs) ) in Biologics

LC/MS. Why is it the fastest growing analytical technique?

A Complete Workflow Solution for Intact Monoclonal Antibody Characterization Using a New High-Performance Benchtop Quadrupole- Orbitrap LC-MS/MS

Tony Mire-Sluis Vice President, Corporate, Product and Device Quality Amgen Inc

Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run

High Resolution Accurate Mass Peptide Quantitation on Thermo Scientific Q Exactive Mass Spectrometers. The world leader in serving science

UFFLC of the Proteome Ultra High Pressure and Ultra Fast Flow Liquid Chromatography: A New Approach To Proteomics

Key Words Q Exactive Focus, SIEVE Software, Biomarker, Discovery, Metabolomics

Agilent CE and CE/MS Solutions FLEXIBILITY AND RELIABILITY TO AMPLIFY YOUR FINDINGS

IgG Purity/Heterogeneity and SDS-MW Assays with High- Speed Separation Method and High Throughput Tray Setup

Application Note. Authors. Abstract

Thermo Scientific EASY-nLC 1200 System. Leading in simplicity. and performance

The Five Key Elements of a Successful Metabolomics Study

Liquid Chromatograph Liquid Chromatograph Mass Spectrometer. CL Series. for In Vitro Diagnostic Use

Peptide Mapping: A Quality by Design (QbD) Approach

Changing the Game in LC-MS/MS. New Tools for Unprecedented Performance in Residue Analysis. Dr. Thomas Glauner

QUANLYNX APPLICATION MANAGER

ProSEC 300S. Protein Characterization columns

THE SOURCE OF NEW POSSIBILITIES

Automated Real-Time Determination of Bromate in Drinking Water Using LC-ICP-MS and EPA Method Application

LabChip GXII: Antibody Analysis

BÜCHI Labortechnik AG

Generating Automated and Efficient LC/MS Peptide Mapping Results with the Biopharmaceutical Platform Solution with UNIFI

Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns

Analysis of Intact and C-terminal Digested IgG1 on an Agilent Bio MAb 5 µm Column

Využití cílené proteomiky pro kontrolu falšování potravin: identifikace peptidových markerů v mase pomocí LC- Q Exactive MS/MS

Automated Online SPE for LC/MS/MS Analysis of Trace Organic Contaminants in Water Using the Agilent 1290 Infinity Flexible Cube Module

Genotoxicity is the property of a compound

Advanced QA/QC characterization MS in QC : Multi Attribute Method

Proteomics. Proteomics is the study of all proteins within organism. Challenges

SCION GC Series. The Gas Chromatographers Choice for Separations

Enabling Systems Biology Driven Proteome Wide Quantitation of Mycobacterium Tuberculosis

Proteomics And Cancer Biomarker Discovery. Dr. Zahid Khan Institute of chemical Sciences (ICS) University of Peshawar. Overview. Cancer.

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

Using accurate mass LC/MS/MS in forensic toxicology screening

ENHANCED MS WITH THE TURN OF A KEY

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

Conjugated protein biotherapeutics

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

Time-resolved Measurements Using the Agilent Cary Eclipse Fluorescence Spectrophotometer A Versatile Instrument for Accurate Measurements

Detecting Challenging Post Translational Modifications (PTMs) using CESI-MS

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Thermo Scientific Mass Spectrometric Immunoassay (MSIA) Pipette Tips. Next generation immunoaffinity. Robust quantitative platform

MetaXpress High-Content Image Acquisition and Analysis Software

Towards unbiased biomarker discovery

Clarus 600. Gas Chromatograph/Mass Spectrometers. your GC/MS results. better. faster.

Asish Chakraborty, St John Skilton, Weibin Chen and John C. Gebler Waters Corporation, Milford, MA, U.S. INTRODUCTION METHODS. Sample preparation

Capillary GC Troubleshooting: a Practical Approach

MassPREP On-Line Desalting Cartridge

Utilizing novel technology for the analysis of therapeutic antibodies and host cell protein contamination

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

Choosing the Right Calibration for the Agilent Bio SEC-3 Column

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

UNIFI: an innovative enabling platform Ken Eglinton Nordic User Training, September 2013

MetaXpress High-Content Image Acquisition and Analysis Software

Completing the performance picture.

Next Generation Sequencing. Target Enrichment

Transcription:

Agilent Accurate-Mass 6500 Series Q-TOF and 600 Series TOF LC/MS Systems The clearly better choice in TOF and Q-TOF LC/MS Our measure is your success. products applications soft ware services

The unmatched confidence of Ultra High Definition Q-TOF Technology plus the speed of Agilent s 90 Infinity LC Welcome to the power and the certainty of Ultra High Definition Q-TOF technology. They come together in the Agilent Accurate-Mass 6500 Series Q-TOF LC/MS and Agilent Accurate-Mass 600 Series TOF LC/MS systems. And now the family is enhanced by the front-end speed, sensitivity, and chromatographic resolution of our new 90 Infinity LC. So you can separate and identify more low abundance compounds faster, easier, and with higher confidence. Whether you are analyzing PTMs, profiling biomarkers, identifying metabolites, screening for pesticides, or characterizing intact proteins, Agilent TOF and Q-TOF solutions deliver the data quality demanded of the most critical science. You get: The analytical performance you need to identify components in complex, real-world samples The speed you need to realize the benefits of today s fastest UHPLC separations The confidence you need to make better decisions, sooner The data-mining tools you need to boost your lab s productivity and take full advantage of superior accurate-mass MS and MS/MS measurements The advanced screening, profiling, and identification capabilities of Agilent s MassHunter software Agilent Accurate-Mass Time-of-Flight (TOF) and Quadrupole Time-of-Flight (Q-TOF) LC/MS systems combine Ultra High Definition Q-TOF technology with advanced MassHunter Workstation software plus the superior HPLC and UHPLC performance and flexibility of the new 90 Infinity LC.

Clearly better performance by any measure Through the use of Ultra High Definition Q-TOF technology, the 600 and 6500 systems achieve industry-leading mass accuracy, dynamic range, and sensitivity without compromising data acquisition speed, mass range, or mass resolution trade-offs that occur in competitive Q-TOF-based systems and even in more expensive Orbitrap mass analyzers. LC sample inlet Nebulizing gas It s a compelling proposition: you get the speed you need to keep up with today s ultra-fast UHPLC separations, plus the MS and MS/MS performance you need to get as much information as possible from the most challenging samples. Super-heated sheath gas Nozzle voltage MS inlet Sub ppm mass accuracy improves confidence and reduces false positives. Ultra high resolving power separates compounds of interest from interferences. Fast data acquisition rates assures maximum data quality and compatibility with the fastest chromatography and high-throughput workflows. Up to five orders of in-spectrum dynamic range reveals trace-level targets even in the presence of vastly more abundant compounds. High, femtogram-level sensitivity finds impurities, metabolites, or biomarkers at extremely low concentrations. Fast, scan-to-scan polarity switching lets you analyze both positive and negative ions in a single experiment. Automatic tuning and reliable delivery of an internal reference mass ensures consistent mass accuracy and reliable elemental composition determination over a wide range of concentrations and m/z. Collimated thermal containment zone results in enhanced MS and MS/MS sensitivity Heated drying gas Resistive sampling capillary Agilent Jet Stream Technology increases LC/MS and LC/MS/MS sensitivity five-fold Agilent Jet Stream Thermal Focusing technology significantly increases MS and MS/MS sensitivity by improving the spatial focusing of electrospray droplets. The innovative technology uses super-heated nitrogen to improve ion generation and desolvation for greater signal and reduced noise. This boosts sensitivity 5x or more for multiple applications, including the analysis of drug candidates and trace levels of food contaminants, metabolites, or biomarkers. To learn more about Agilent 6500 Q-TOF and 600 Series TOF LC/MS solutions, visit www.agilent.com/chem/qtof 3

Exceptional MS and MS/MS performance fully compatible with UHPLC Whether you analyze small molecules or high MW proteins, the accurate-mass measurements of Agilent 6500 Series and 600 Series systems give you greater certainty for screening, identification, and quantitation studies. Hardware innovations such as Agilent Jet Stream technology, ultra-fast analog-to-digital (ADC) acquisition, and automated reference mass delivery (now expanded for all Agilent liquid phase ion sources) all contribute to breakthrough performance improvements over previous generation TOF and Q-TOF instruments. The result: exceptional analytical performance across multiple dimensions. Sensitivity, accurate mass, dynamic range, and resolution all fully compatible with ultra-fast UHPLC separations. Exceptional mass resolution helps you find more compounds This example uses the 90 Infinity LC with a ZORBAX Rapid Resolution High Definition (RRHD) column and 6540 Accurate-Mass Q-TOF. A 90- second assay of a suite of 50 pesticides yields excellent chromatographic and mass spectral resolution across the pesticide mass range. Three pesticide examples are detailed, representing low, mid, and high m/z. x0 5 +ESI EIC(609.8066) Scan Frag=40.0V Reserpine_40pgms3.d Error. 0.5 Run (ppm) 0.96-0.7 3 0.5 4 0.0 5 0.39 6 0.3 0.6 7 0.0 8 0.5 9 0.04 0 0.30 Mean 0.5 0. Std. Dev 0.3 0 0.0 0.5 0.5 0.75 Counts vs. Acquisition Time (min) Is o to p e O b s % Calc % O b s m /z Calc m /z D if f (p p m ) 609.808 A 00 00 609.808 609.8066 0.5 A+ 35.87 37.4 645 6393 0.5 A+ 8.58 8.59 6.8650 6.867-0.34 A+3.4.48 6.8987 6.894 0.75 A+4 0. 63.90 63.903 0. 645 6.8650 6.8987 63.90 609 60 6 6 63 64 Counts vs. Mass-to-Charge (m/z) Exceptional mass accuracy improves analytical confidence The innovative design of the 6500 Q-TOF collision cell and ion optics allows the same reference mass calibration to be used for both MS and MS/MS. The resulting MS mass accuracy in this example, 0.3 ppm and precise i sotopic ratios greatly improve confidence in molecular formula generation. Excellent isotopic ratio fidelity is shown for 0 replicate reserpine injections at 40 pg on-column. 4

Dual-stage ion mirror improves second-order time focusing for high mass resolution. Ion Beam Compression (IBC) Technology (patent pending) compresses and cools the ion beam up to 0-fold, resulting in fewer ion losses and more precise mass assignment. Mass resolution and mass accuracy are improved up to 00 percent. Proprietary INVAR flight tube sealed in a vacuum-insulated shell eliminates thermal mass drift due to temperature changes to maintain excellent mass accuracy. Added length improves mass resolution. Unlike time-to-digital (TDC) detectors which record single ion events, analog-to-digital (ADC) detection records multiple ion events, allowing very accurate mass assignments over a wide mass range and dynamic range of concentrations. Ion source innovations such as proprietary orthogonal spray maximize ion generation and reduce noise, while maintaining excellent accurate mass with automated introduction of an internal reference mass. 4GHz ADC electronics enable a high sampling rate (3 Gbit/s) which improves the resolution, mass accuracy, and sensitivity for low-abundance samples. Dual gain amplifiers simultaneously process detector signals through both low-gain and highgain channels, extending the dynamic range to 0 5. Ions are accelerated in the hexapole collision cell to enable faster generation of high-quality MS/MS spectra. To learn more about Agilent 6500 Q-TOF and 600 Series TOF LC/MS solutions, visit www.agilent.com/chem/qtof 5

Clearly better productivity for any application Sometimes productivity is all about speed. Sometimes it s all about data quality. And often, it s about both. Agilent TOF and Q-TOF solutions offer a combination of unbeatable separation speed and resolution, superior qualitative MS and MS/MS capabilities, and powerful MassHunter data mining software so they can match any productivity challenge your lab may have. Agilent 90 Infinity LC System: An infinitely better liquid chromatography platform The 90 Infinity LC complements the performance of Ultra High Definition Q-TOF technology and allows you to optimize your separations for maximum productivity. ZORBAX Rapid Resolution High Definition (RRHD) columns provide the separating power for excellent UHPLC results. Take full advantage of fast chromatography for highthroughput analysis. For very complex samples, use the 90 Infinity LC system s unmatched peak capacity and chromatographic resolution to minimize co-elution and ion suppression effects. The Agilent 90 Infinity LC delivers unprecedented, best-in-class speed, resolution, and sensitivity for better overall HPLC and UHPLC performance. HPLC-Chip/MS technology offers highest sensitivity for small-volume samples The Agilent 6500 Series and 600 Series systems are also fully compatible with our innovative 00 Series HPLC-Chip/MS technology a plug-and-play alternative to complicated nanoflow LC separations. The easy-to-use technology combines the sample enrichment and separation columns of a 00 Series Nanoflow LC system with an integrated nanospray tip all on a single, reusable microfluidic chip about the size of a microscope slide. It delivers robust, ultra-sensitive results and is especially well-suited for protein and peptide applications using small sample volumes. Highest sensitivity ensures low-level sample fidelity. Narrower, better-defined chromatographic peaks reduce MS complexity for more confident compound identification. The new HPLC-Chip II features a new carbon-ionimplanted filter resulting in optimal chip-to-chip and run-to-run reproducibility for maximum productivity. More reliable nanospray MS facilitates biomarker discovery and validation, intact monoclonal antibody characterization, phosphopeptide analysis, and small molecule analysis, such as DMPK. 6

MassHunter software amplifies your productivity From instrument setup to final report, Agilent s MassHunter Workstation software is designed to make all of your MS analyses faster, easier, and more productive. Data analysis tools let you quickly find, compare, and identify compounds in complex matrices. Compound-centric data-mining and navigation capabilities streamline and simplify MS data analyses. One easy-to-learn interface handles all of your basic qualitative and quantitative analysis tasks and also integrates seamlessly with Agilent s powerful application-specific workflow software. If it s there, MassHunter will help you find, compare, and identify it. Proprietary algorithms enable comprehensive data mining to bring the highest level of certainty to the confirmation and identification of unknowns. Integrated, application-driven database and library searching. To enhance your productivity and to make compound identification easier MassHunter software lets you perform automated, accurate-mass searches against METLIN and other public and private databases. Pesticide, forensic, toxicology, and other small molecule compounds can be searched using accurate mass and retention time or by generating molecular formulas from accurate-mass MS or MS/MS data. Compound-centric data navigation and selection Detailed Molecular Formula Generation and accurate mass databases search results Method Editor and Explorer List of compounds with best molecular formulas and accurate mass databases search hits Overlaid compound chromatograms for each individual compound Mass peak list with identified ion species for each compound Compound mass spectrum with a theoretical isotope pattern overlaid for generated formulas Easily find, compare, and identify compounds in qualitative analysis. MassHunter Workstation makes it easy to create, organize, navigate, store, and report results on a compound-by-compound basis. FIND COMPARE IDENTIFY QUANTIFY Automatically find, compare, identify, and quantitate compounds using MassHunter Workstation s unique compound-centric data processing. To learn more about Agilent 6500 Q-TOF and 600 Series TOF LC/MS solutions, visit www.agilent.com/chem/qtof 7

Powerful, easy-to-use solutions for food safety and environmental analysis Agilent s combination of ultra-fast spectral acquisition, wide dynamic range, and superior mass accuracy and mass resolution lets you screen for hundreds of compounds in a single analysis even in the most complex matrices. MassHunter software locates sample components and automatically searches your public and private databases, rapidly providing high-confidence answers. New Agilent application kits including methods, chemicals, compound databases, and more help you spend less time on setup and configuration and more time generating expert results. Ultra-fast screening and identification of pesticides x05.9.8.7.6.5.4.3.. 0.9 0.7 0.6 0.5 0.3 0. 0.649 0. 0 0. 0. 0.3 0.5 0.6 0.7 0.9...3.4.5.6.7 Counts vs. Acquisition Time (min).8.9...3.4.5.6.7.8.9 3 Q-TOF identification of 00 pesticides in less than three minutes. Superior peak capacity and fast MS acquisition lets you resolve large numbers of pesticides and ensures high confidence in compound identification. The fast acquisition capability of the Q-TOF allows considerably shorter run times while still acquiring full spectral data. (90 Infinity LC using a ZORBAX RRHD column and 6540 Accurate-Mass Q-TOF) High resolution MS, sub ppm mass accuracy, and isotope peak fidelity at 0 scans per second x04.3. 94.366. 0.5 ppm.9.8.7.6.5.4 Cl.3 Cl.. CH3 CH3 H3C H3C 0.9 N H3C N 0.7 OH N H3C 96.337 N OH N N 0.6 0.5 95.396 0.3 0. 0. 0 94 94.5 94.5 94.75 95 95.5 95.5 95.75 96 96.5 96.5 96.75 97 97.5 97.5 97.75 Counts vs. Mass-to-Charge (m/z) Screening for thousands of pesticides in three minutes. In this example, 0 data points are collected across each one-second wide LC peak, allowing thousands of pesticides to be screened in the three-minute timeframe. 8

Powerful workflows find more biomarkers, more quickly Agilent s Ultra High Definition Q-TOF technology gives you the power to quickly find differences in expression levels between sample groups and identify potential biomarkers in your accurate-mass LC/MS data. Together with integrated software solutions such as Agilent s METLIN Personal Metabolite Database and Mass Profiler Professional the platform provides tools to help understand complex biological systems. Superior TOF sensitivity and five orders of dynamic range help you detect very low-abundance metabolites in the presence of vastly more abundant compounds. Sub-ppm MS typical mass accuracy generates higher confidence in compound identification and reduces false positives when searching with Agilent s METLIN Personal Metabolite Database of over 3,000 endogenous and exogenous metabolites, lipids, and di- and tripeptides. A comprehensive suite of metabolomics data mining tools for profiling, multivariate analysis, identification, and pathway elucidation Identify Non-infected Infected Biology This analysis involved two sets of replicate malaria-infected and non-infected red blood cell samples. PCA analysis was performed and correctly grouped the eight samples based on 750 entities. This was followed by differential analysis which resulted in identifying arginine as a significant biological marker for this study. Arginine was then correctly mapped to the arginine synthase pathway using Agilent Pathway Architect software. To learn more about Agilent 6500 Q-TOF and 600 Series TOF LC/MS solutions, visit www.agilent.com/chem/qtof 9

High-confidence biomolecule identification, characterization, and quantitation Agilent s 00 Series HPLC-Chip/MS system provides fast, highly reproducible nanoflow LC separations critical for achieving good results in differential analysis, and an ideal complement to the high spectral quality of the Accurate-Mass Q-TOF platform. Wide dynamic range, coupled with excellent mass accuracy and mass resolution, optimizes profiling performance allowing you to uncover more lowabundance compounds and to see peptides and proteins at both high and low levels of concentration. Excellent MS reproducibility x0 5 9.5 9 8.5 8 7.5 7 6.5 6 5.5 5 4.5 4 3.5 3.5.5 0.5 Two replicate runs overlaid without scaling, illustrating excellent reproducibility of both retention time and ionization yield x0 5 3. 3.8.6.4..8.6.4. 0.6 0. 0-0. zoomed/overlaid 4 5 6 7 8 9 0 3 4 5 6 7 8 Counts vs. Acquisition Time (min) 4 6 8 0 4 6 8 0 4 6 8 30 3 34 36 38 40 4 44 46 48 50 5 54 56 58 60 6 64 66 68 70 7 74 76 78 Counts vs. Acquisition Time (min) Overlaid chromatograms are shown for two replicate runs of a tryptic digest of an SEC fraction from a Schizosaccharomyces pombe sample. The results show the high level of reproducibility of both retention time and ionization yield. (Agilent HPLC-Chip/MS and 6540 Accurate-Mass Q-TOF) Superior MS/MS mass accuracy ALIMDLEGLTGQIVK An MS/MS spectrum is shown for a peptide, ALIMDLEGLTGQIVK, from Schizosaccharomyces pombe. All b- and y- ions from the peptide are shown with corresponding mass accuracy values. (Agilent HPLC-Chip/MS and 6538 Accurate-Mass Q-TOF) 0

Reliable confirmation of intact proteins Full characterization of proteins of interest including details about molecular composition and structural variations requires in-depth, accurate analysis of both the intact and digested forms. The accurate-mass MS and MS/MS measurements of Agilent s Q-TOF platform ensure higher confidence in identifying intact proteins. The system s high resolution resolves charge states and gives you the power to pinpoint small changes in structure from post-translational modifications, chemical degradation, and modification. MassHunter BioConfirm software provides optimized mass spectral deconvolution and a sequence editor/matcher for peptide mapping, as well as the prediction and confirmation of protein modifications, resulting in accelerated characterization of recombinant proteins and synthetic peptides. 00 percent sequence coverage of monoclonal antibody digest x0 6.8.6.4. 0.6 0. TIC x0 5 5.5 5 4.5 4 3.5 3.5.5 0.5 ECC for Matched Peptides 0. 0. 0.3 0.5 0.6 0.7 0.9...3.4.5 Counts vs. Acquisition Time (min) 0 0. 0. 0.3 0.5 0.6 0.7 0.9...3.4.5 Counts vs. Acquisition Time (min) Complete mab sequence coverage in less than two minutes. This example shows extracted compound chromatograms (ECC) for peptides matched to the IgG sequence; for both light and heavy chains, 00 percent sequence coverage was obtained. At a flow rate of.6 ml/min with system pressure of >00 bar, analysis time was under two minutes. (Agilent 90 Infinity LC using a Poroshell 0 column and 6530 Accurate-Mass Q-TOF) MS measurement and deconvolution of intact antibody x0 3 3. 3.8.6.4..8.6.4. 0.6 0. 0 450 500 550 600 650 700 750 800 850 900 950 3000 3050 300 350 Counts vs. Mass-to-Charge (m/z) x0 4 48573.79.9 48734.66.8.7.6.5.4.3. 484.67. 0.9 48894.57 0.7 0.6 0.5 49055.90 0.3 495.66 0. 0. 0 48000 4800 48400 48600 48800 49000 4900 49400 49600 Counts vs. Deconvoluted Mass (amu) MS spectrum of deglycosylated ANTI-FLAG antibody following a 600 pg (4 fmol) injection on column. The deconvoluted spectrum on the right shows six different major glycoforms. Analysis was performed using HPLC-Chip/MS with 43 mm ZORBAX SB 300-C8 chip. (Agilent HPLC-Chip/MS and 6530 Accurate-Mass Q-TOF) To learn more about Agilent 6500 Q-TOF and 600 Series TOF LC/MS solutions, visit www.agilent.com/chem/qtof

Workflow-driven applications add power and productivity To maximize your lab s productivity, easy-to-use, applicationspecific software solutions can be seamlessly integrated into MassHunter Workstation. These include: Mass Profiler Professional Powerful chemometrics software package that fully exploits the high information content of accurate-mass MS data Spectrum Mill for MassHunter Workstation Protein identification, relative quantitation, characterization MassHunter BioConfirm Software Intact protein characterization and oligonucleotide analysis MassHunter Metabolite ID Software Drug metabolite identification Personal Compound Database & Library Software MassHunter Personal Forensic and Toxicology Database Over 7,000 compounds available MassHunter Personal Pesticide Database Over,600 compounds available Agilent METLIN Personal Metabolite Database Most comprehensive endogenous metabolite database available includes over 3,000 compounds including 8,000 lipids Agilent Services keep your lab running at peak productivity With a 98% customer satisfaction rating, Agilent s service engineers are the most respected and best-trained in the industry. Whether you need support for a single instrument or a multi-lab, multi-vendor operation, we can help you solve problems quickly, increase your uptime, and optimize your lab s resources. Through a selection of service plans tailored to your lab s needs and budget, we provide: On-site preventive maintenance that ensures dependable system operation and minimizes unplanned downtime Remote diagnostic and monitoring capabilities that give you additional uptime insurance Rapid, expert troubleshooting and repair for Agilent and non-agilent instruments Expert installation, familiarization, and advanced training to get you up and running as quickly as possible and to make sure you get the most from your new Agilent equipment For more information Learn more: www.agilent.com/chem/qtof Buy online: www.agilent.com/chem/store Find an Agilent customer center in your country: www.agilent.com/chem/contactus U.S. and Canada -800-7-9770 agilent_inquiries@agilent.com Europe info_agilent@agilent.com Asia Pacific inquiry_lsca@agilent.com Research use only. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Agilent Technologies, Inc. 03 Printed in USA September 9, 03 5990-405EN