[Authors], [Year] [Title of the paper] in "Abstracts of the 3rd EJIL - LAETA Young

Similar documents
HydroSet. Injectable HA Bone Substitute

Composite. Solutions for composite applications

LUBRICATION & MACHINING OF COMPACTED GRAPHITE IRON

TEMPERATURE AND HEAT EFFECTS ON POLYETHYLENE BEHAVIOUR IN THE PRESENCE OF IMPERFECTIONS

An effective sensor for tool wear monitoring in face milling: Acoustic emission

HIGH PERFORMANCE PRODUCT

Analysis of Micro Generation Impacts in Distribution Networks

Functional Assessment and Clinical Outcome

Small thermal energy storage units filled with microencapsulated PCMs for building applications

Electrochemical Die-Sinking (ECM) in Practice

Drilling Speeds and Feeds

Organizing committee at imed.ulisboa/ffulisboa Joao Goncalves (Coordinator) and Paula Brito.

Drilling System. ATI Stellram tooling systems for all your drilling requirements.

Microstructure refinement by tool rotation-induced vibration in incremental sheet forming

Finite Element Analysis of Medical Devices: WS Atkins Perspective

SERIES

A Comparative Study of Failure with Incremental Forming

EUROPEAN PRECISION AND QUALITY SAWS HIGH SPEED STEEL, COBALT & CARBIDE METAL CUTTING SAWS

CONCENTRATE AND BRINE MANAGEMENT THROUGH DEEP WELL INJECTION. Abstract

Multi-Objective Optimization in CNC Turning of S45C Carbon Steel using Taguchi and Grey Relational Analysis Method

IMPACT SOUND REDUCTION OF CONCRETE LAYERS CONTAINING CORK GRANULES

ERC/NSM Activities. Research for Industry and Government

ENHANCING OPERATIONAL SAFETY AND LOGISTICAL EFFICIENCY FOR TORPEDO LADLES

NANO SCRATCH/MAR TESTING OF PAINT ON METAL SUBSTRATE

View of INEGI buildings in the campus of the Faculty of Engineering of the University of Porto

Experimental evaluation of machining parameters in machining of 7075 aluminium alloy with cryogenic liquid nitrogen coolant

Development of Veress Needle Insertion Robotic System and Its Experimental Study for Force Acquisition in Soft Tissue

Cortical Bone Healing after Internal Fixation and Infection

VAPR TRIPOLAR 90 Suction Electrode with COOLPULSE Technology VALUE ANALYSIS BRIEF

Numerical Analysis of the Influence of Geometry of Ceramic Units (Blocks) on Structural Walls

Cutting Temperature and Laser Beam Temperature Effects on Cutting Tool Deformation in Laser-assisted Machining

Effect of Low Feed Rate FSP on Microstructure and Mechanical Properties of Extruded Cast 2285 Aluminum Alloy

Advanced FEA Stress Analysis of Medical Instruments and Devices using Femap, NX Nastran and LS-DYNA

AUTOMATIC WELDING SPEED CONTROL BY MONITORING IMAGE OF WELD POOL USING VISION SENSOR

Keeping the Customer First. Tungaloy Catalogue TE0707-E2. Cutting Tools.

Use of Quantitative Scanning Electron Microscopy of S. aureus Biofilm Formation in vitro to Identify Strain and Implant Material Specificities

António Morais. University of Lisbon, Lisbon, Portugal

AIR QUENCHING OF ALUMINUM: THE AFFECT OF QUENCH ORIENTATION AND AIR VELOCITY

Concept and manufacture of a hollow crankshaft forming tool

NUMERICAL MACHINING SIMULATION FOR AN AISI 304 STAINLESS STEEL CONSIDERING MICROFRACTURE MECHANICS ASPECTS

LABORATORY INVESTIGATION Light and Photosynthesis - Teacher Instructions

M.A. Ford Where high performance is the standard. Phone: or

STACKING SEQUENCE EFFECT ON POLYMER/COMPOSITE MULTI-LAYERS SUBMITTED TO THERMOMECHANICAL CYCLIC LOADINGS

Postprint.

Analysis of the corrosion test process for heat exchangers in corrosion test chambers by CFD simulation

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

Ultrasonic Assisted Machining Introducing Intense Vibrations to Enhance Metalworking

The Lancet Publishes Results from the Landmark Phase III Rivaroxaban Study RECORD2

MECHANICAL PROPERTIES

CONNECTIONS OF TRAPEZOIDAL SHEETS UNDER FIRE. Petra Kallerová, František Wald, Zdeněk Sokol

Course ADVANCED DRUG DELIVERY July 03-07, 2017 Faculty of Pharmacy Amphitheatre B Universidade de Lisboa, Portugal

Deep Hole Drills. RT 100 T coolant fed, solid carbide twist drills EB 100 solid carbide gun drills EB 80 Conventional brazed head gun drills

Cooling Device for Transesophageal Ultrasound

Surface Characterization of Biomaterials

Giddings & Lewis FT / FTR Series, Floor-Type Horizontal Boring Mills

RF 100 Speed GUHRING - YOUR WORLD-WIDE PARTNER. High-performance roughing even at deep cutting depths. Smooth operation and high metal removal rate

Thermoelectric Detection of Spherical Tin Inclusions in Copper by Magnetic Sensing

Healthcare Technology Assessment Division HTAD of the International Federation for Medical and Biological Engineering IFMBE

DISTORTION PREDICTION IN QUENCHING AISI 4140 C- RINGS WITH DIFFERENT QUENCHANTS 1

MASTERBATCHES. Masterbatch Application and Selection Guide for Irrigation Pipes

TRELLIS COLLAGEN RIBBON

Universidade da Beira Interior

Main Drivers for the Iberian Market Price And Energy Storage in Portugal

Heat Transfer in Laser Tumor Excision

Machine and Vehicle Design: Master Thesis presentation

COMPACT STRIEBIG 4D CONTROL EVOLUTION STANDARD S STANDARD COMPACT. FLEXIBLE AND ECONOMICAL Entry level to vertical sawing technology

Available online at ScienceDirect. Procedia CIRP 31 (2015 ) th CIRP Conference on Modelling of Machining Operations

Chamber Temperature Measurement of Micro PCR Chip Using Thermocouple

This paper presents the summary of a experimental study related to the. surface coating, of zinc or aluminum. The main objective of the study was

Introducing a new take on efficient workflow: Deeply integrated clinical applications

MATERIALIZING VISIONS. Bohler-Uddeholm M42 HIGH SPEED STEEL

LD21 NEW MATERIALS FOR LARGE-CALIBER ROTATING BANDS FOR HIGH CHARGES. M. Schupfer1, K. Steinhoff2, R. Röthlisberger1 1.

Hybrid Short Path Evaporation as an Option to Lactic Acid Recovery from Fermentation Broth

ATI Datalloy HP TM Alloy

Superabrasive CUTTING TOOLS & WEAR PARTS

Adipose rabbit mesenchymal stem cells for the treatment of the chronic scar tissue of the vocal cords

PATIENT DOSIMETRY IN INTERVENTIONAL RADIOLOGY

Effect of Twisted Tape Inserts On Heat Transfer in A Concentric Tube Heat Exchanger

AN EXERGY COST ANALYSIS OF A COGENERATION PLANT

MEASURING THE WATER TEMPERATURE CHANGES THROUGHOUT THE ABRASIVE WATER JET CUTTING SYSTEM

Tooling for Composites and Aerospace Materials. Diamond coated, carbide and PCD tools Routers, drills, and end mills Full special design capabilities

Medical Area at the METAV 2018: customised solutions for curative competence

AC50 Silver Adhesive Anchoring System

DAS FRAUNHOFER IKTS ALS INNOVATIVER PARTNER IM BEREICH BIO- UND MEDIZINTECHNIK

Effective troubleshooting of extrusion problems

FINITE ELEMENTSIMULATION IN ORTHOGONAL MACHINING OF INCONEL 718 ALLOY

Application Note #1007 All-Inclusive Scratch Testing of Coatings and Thin Films Using Bruker's Universal Test System

The Children s Hospital of Philadelphia Department of Pathology and Laboratory Medicine

NATIONAL COUNCIL OF ETHICS FOR THE LIFE SCIENCES Presidency of the Council of Ministers 56/CNECV/08

THE BEHAVIOR OF TWO MASONRY INFILLED FRAMES: A NUMERICAL STUDY

Index. MEGA-Spike-Drill. Product presentation 4 General information 5 Technical specification 5. MEGA-Spike-Drill M9535 6

Parametric Optimization for Friction Stir Welding of Al6061 Alloy using Taguchi Technique

The prediction of toughness and strength in high integrity forgings

Simulation of High Pressure Die Casting (HPDC) via STAR-Cast

Bone Tissue Mechanics

DEVELOPMENT OF IN-SITU MONITORING SYSTEM FOR SINTERING OF CERAMICS USING LASER AE TECHNIQUE

3. Residual Stresses

Transcription:

ORGANIZING COMMITTEE Miguel Almeida (Chairman) - ADAI, LAETA André Silva - AeroG, LAETA Carla Roque - INEGI, LAETA Duarte Albuquerque - IDMEC, LAETA Eugênio Rodrigues ADAI, LAETA Luís Mário Ribeiro ADAI, LAETA Ramiro Martins - FNEGI, LAETA Susana Vinga - IDMEC, LAETA AD VISORY COMMITTEE Domingos Xavier Viegas (Chairman) - ADAI, LAETA José Carlos Pereira - IDMEC, LAETA Carlos Mota Soares - IDMEC, LAETA Jorge Humberto Seabra - INEGI, LAETA Jorge Barata - AeroG, LAETA Renato Natal Jorge - INEGI, LAETA ADITIONAL INFORMATION To open the füll papers available online at https://app. box. com/3ejil use the password "coimbra3ejil". The correct citation for the füll papers is: [Authors], [Year] [Title of the paper] in "Abstracts of the 3rd EJIL - LAETA Young Researchers Meeting". Coimbra 2015. Edited by LAETA. ISBN 978-989-99080-1-7'. Available at https://app. box. com/3ejil.

3 EJIL - LAETA Young Researchers Meeting ADAI, Coimbra, 7-8 May 2015 TEMPERATURE ASSESSMENT IN THE DRILLING OF COMPOSITE MATERIALS AND EX-VIVO PORCINE BONES Maria Fernandes 1 a*, Elza Fonseca 2 b, Renato Natal 3 c, Maria Isabel Dias 4 d a) INEGI, FEUP, Rua Dr. Roberto Frias 400, 4200-465 Porto b) LAETA-INEGI/UMNMEE, IPB, Campus de Santa Apolónia, 5301-857 Bragança c) INEGI, FEUP, Rua Dr. Roberto Frias 400, 4200-465 Porto d) CITAB, UTAD, Quinta de Prados, 5000-801 Vila Real * e-mail: mgfernandes@inegi.up.pt Key words: Bone Cutting, Experimental methods, Temperatures Abstract. This study presents different experimental methodologies for analysis and temperature evaluation during the drilling process of composite materials and ex-vivo porcine bones. In the experimental methodologies were evaluated the influence of different parameters on the bone temperature rise. The combinations of different parameters produced temperatures far below the critical values. It was concluded that drill temperature decreases when the feed-rate is higher and, independently, increases with the increasing of hole depth. The influence of drill speed is not clear. In the composite materials the temperature decreases in the drill bit when the drill speed is higher, and in ex-vivo porcine bones happens the opposite. The animal models recorded lower temperature values than composite materials. 1 INTRODUCTION The bone cutting is a procedure widely used in medicine, including orthopaedic, dental and neuro surgeries. The success of this surgeries is dependent of many factors and also in temperature generation during the drilling bone. When an excessive heat is produced during the drilling bone the thermal necrosis can occur, and the bone suffers injuries. Eriksson and Albrektsson indicated that thermal necrosis in cortical bone from living rabbits occurred when this one reached a temperature of 47 ºC for 1 minute. Other authors showed that temperature values above 55 ºC for a period longer than 30 seconds can cause great irreversible lesions in bone tissue. The main goal of many researchers has been finding one way for reducing the heat generated in drilling processes. Studies have shown that the increased temperature is directly related with the cutting parameters, particularly, the drill speed, feed-rate, applied force, the hole depth, the geometry of the drill bit, the use or not of a cooling system and also the type of bone. The heat generated from the contact between the cutting tool and the bone tissue, during the bone drilling in surgical operations has been a known problem for years. The increase of heat is caused by friction of the cutting surface of the drill bit in contact with the bone tissue and converts the applied cutting energy into heat energy that causes necrosis and combustion of bone tissue, which means the irreversible death of bone cells [1]. The post-operative success of these surgeries is widely conditioned by the temperature generation and the level of

damage in the bone tissue during the drilling operation [2]. The reduction of damage in bone surgeries is very important to the reduction of rejected implants, to increase the capacity of bone regeneration and decrease the patient recovery time [3, 4]. Currently, it is known that the heat generation in the drilling process is associated to drilling parameters. Thus, it is important to understand and to improve the drilling conditions and all the involved variables, to reduce the heat generated and consequently minimize the bone damage. The analysis of the temperature changes during drilling has been examined in animal models and in specific materials with similar properties to the human bone tissue [5]. Several studies have focused on measuring temperature distribution during bone drilling, where thermocouple measurements is most frequently choice. However, the uncertainty in sensor placement and the heat conduction within the sensor, where the thermal conductivity of the bone is two orders of magnitude smaller than that of the thermocouple wires, can be a problem [6]. An alternative method of measurement is the thermography technique that allows surface measurements in the cutting tool and bone. In this study, the combined of two experimental methodologies has been executed by considering the effects of drill speed, feed-rate and hole depth on the maximum temperature during drilling of several fresh porcine bones and composite materials. Different drill speed were used in the experimental tests: 600, 800 and 1200 rpm; feedrates of 25, 50 and 75 mm/min and a drill bit with 4 mm of diameter. In both methodologies, a thermographic camera was used to capture the surface temperature in the drill bit. 2 EXPERIMENTAL METHODOLOGIES In order to keep the bone necrosis to a minimum level, two experimental methodologies were used to evaluate the temperature during the drilling processes of different materials with different drilling parameters. In the first methodology, composite materials with similar density to the human bone were used and in the second one, an ex-vivo study was performed by considering the porcine femur bones. Both methods were performed in the Mechanical Laboratory at IPB-ESTiG (Polytechnic Institute of Bragança), using a computer numerically controlled (CNC) machine system with total control of the involved parameters. 2.1 Drilling process of composite materials To the drilling operations in composite materials, three composite blocks were chosen with similar mechanical properties to the human bone. The composite blocks have the following dimensions: 130x180x40mm [7]. In order to evaluate the temperature in cutting tool, a thermographic camera (ThermaCAM 365, FLIR Systems) at a distance of 1.5 m from the drilling area was used. The thermal camera allowed to obtain thermal images before and after of drilling process (Figure 1) [8]. Several holes were made using a conventional drill bit with 4 mm of diameter, 30 mm of depth and a point angle equal to 118º. In order to evaluate the influence of the drill parameters, a set of three different drill speeds and three different feed-rates were considered (Table 1). The other parameters were considered as a constant in all experiments. 2

Figure 1: Drilling operations of composite materials. 2.2 Drilling process of ex-vivo porcine bone Through three samples of porcine femur was elaborated an ex-vivo study to evaluate the temperature in the cortical bone tissue. The fresh porcine bone was chosen due to its mechanical properties similar to human bone [9]. The bone samples were obtained from a local butchery, after animal death from animals processed for food industry (no animals were sacrificed specifically for the purpose of the current study). The samples have been previously cleaned (muscle removed), as shown in Figure 2. In order to retain the mechanical and thermo-physical properties, the samples were prepared according to the guidelines established by Yuehuei and Robert [10]. All samples were kept moist in saline solution with gauze swabs and stored in plastic bags at -4ºC, before the tests. To realize the experiments, the periosteum was removed from the outer surface of the bone samples, as it clogs the drill flutes [11]. All the epiphysis were removed and the mid-diaphysis columns were obtained using a hacksaw (Figure 2). Also the bone marrow was removed, leaving only the cortical tissue [12]. (a) (b) (c) Figure 2: (a) fresh bone; (b) sample cut from mid-diaphysis and (c) sample with gauze swabs. The porcine samples present the approximate dimensions of 7-9 mm in length with an average thickness of the cortical wall of 4-6 mm. All samples were divided to accommodating several drilled holes. In order to compare the obtained results in composite materials with ex-vivo bones, the same parameters and cutting tool were used during the tests (Table 1). 3

Table 1: Parameters of drilling. Parameters Composite materials Ex vivo porcine bones Drill diameter (mm) 4 4 Drill point angle (degrees) 118 118 Depth of the holes (mm) 30 5 Drill speed (rpm) 600, 800, 1200 600, 800, 1200 Feed rate (mm/min) 25, 50, 75 25, 50, 75 As it was tested in the composite materials, only the thermographic camera was used to measure the temperature in drill bit, before and after of drilling process in ex-vivo porcine bones. The holes were carried out at room temperature without cooling. Figure 3: Experimental setup of bone drilling. 3 RESULTS AND DISCUSIONS To evaluate the generation of temperature in bone tissue it is important to take into account that the inherent variation in mechanical and thermal properties of specimens taken from different bones in the animal, and from different animals of the same species, results in variations in the measured temperature subject to virtually identical drilling conditions in repeated experiments [6]. In this study three samples of femurs porcine bone from three different animals and three composite blocks were used to measure the temperature. During drilling of the bone, the cortical tissue is the main part of the bone that generates higher temperatures. The current study aims to realize an experimental investigation of the effects of drill speed, feed-rate and hole depth, on the temperature distribution in the cutting tool during drilling of the cortical section of the porcine femurs and composite materials. Evaluation tests were performed under two representative sets of drilling conditions: the first one, the holes were performed with feed-rates of 25, 50 and 75 mm/min and a constant drill speed of 800 rpm and the second one with drill speeds equal to 600 and 1200 rpm and a constant feed-rate of 50 mm/min. The tests were repeated several times for each set of conditions and for both methodologies. The Tables 2 and 3 present the mean values of the temperature in the tool cutting, obtained in different tests. 4

Table 2: Temperature variation from drill bit, before and after drilling, in composite materials. Composite materials Drill speed [rpm] Feed-rate [mm/min] ΔT [ºC] Mean ± SD [Range] 600 50 (n=6) 102.75 ± 14.16 [77.80-115.80] 1200 50 (n=6) 87.45 ± 7.25 [76.20-97.0] 25 (n=8) 86.81 ± 9.20 [76.70-102.60] 800 50 (n=7) 72.73 ± 9.69 [55.80-84.40] 75 (n=8) 63.69 ± 6.63 [51.20-70,80] n number of the holes, SD Standard deviation, ΔT Temperature variation Table 3: Temperature variation from drill bit, before and after drilling, in ex-vivo porcine bones. Ex vivo porcine samples Drill speed [rpm] Feed-rate [mm/min] ΔT [ºC] Mean ± SD [Range] 600 50 (n=7) 28.22 ± 6.20 [20.4-34.20] 1200 50 (n=7) 36.60 ± 3.49 [31.0-41.20] 25 (n=7) 26.42 ± 6.51 [15.90-33.90] 800 50 (n=5) 18.36 ± 1.82 [16.10-21.10] 75 (n=7) 18.87 ± 1.46 [16.80-20.80] n number of the holes, SD Standard deviation, ΔT Temperature variation Comparing the results obtained in the Tables 2 and 3, it was found that the temperature in the cutting tool is higher in holes made in composite materials, when compared with holes in ex-vivo porcine femurs. These results were expected, since the holes depth in the composite materials (30 mm) is higher than in ex-vivo bones (5 mm). In addition, the composite materials have a constant geometry over the whole model while the samples of porcine femur have an irregularly geometry, with different cortical thickness along its diaphysis. In both studies it can be observed that maximum temperature in the cutting tool decrease with the increasing feed-rate. This observation is consistent with the literature, where increased of feed-rate was seen to reduce the drilling temperatures during bone drilling [5, 6, 8, 12]. Regarding the drill speed it was found there is not agreement between composite materials and bone samples. In composite materials, the maximum temperature in the cutting tool decreases with the increase of drill speed but in the porcine samples it is just the inverse. Also, in the literature it is not found agreement among different authors [13]. This can be explained by the fact that the increase of drill speed increases the friction energy generation due to the friction forces acting on the rake face of the drill bit (close to the cutting edges). Since a majority of this energy is converted into heat, it is reasonable to expect increased temperatures at higher drill speeds [14], as it is supported by the results from ex-vivo study. However, with higher drill speeds, the chips are moving faster away from the cutting zone, which results in a higher heat transfer rate from this zone with the stream of chips; this stream generates an apparent cooling effect [6]. While this cooling effect is not sufficient to reverse the trend due to the increased friction energy, it may be responsible for different results with different materials. 5

4 CONCLUSIONS In the present study were used experimental methods to investigate the effects of feedrate, drill speed and hole depth on temperature generation of cutting tool during drilling in porcine femur models and composite materials using a thermography technique. In general, it was found that the maximum drill temperature increased with the increasing of hole depth and, independently, decreases with the increasing feed-rate. Comparing the results for different drill speeds, it was verified does not exist a consistent trend. In the composite materials was found that higher drill speed produces lower drill temperatures and in the porcine femur models happens the opposite. In this study the obtained values of temperature in the drilling process of ex-vivo cortical tissue from porcine femurs were lower than the drilling process of composite material. ACKNOWLEDGEMENTS The author of this paper acknowledges the support of the Project "Biomechanics: Contributions to the healthcare" co-financed by the Regional Operational Programme of North (ON.2 - The New North), the National Strategic Reference Framework (NSRF), through the European Development Fund (ERDF) and also to the project UID/EMS/50022/2013 of LAETA financed by FCT. REFERENCES [1] Karmani S., The Thermal Properties of Bone and the Effects of Surgical Intervention, Current Orthopaedics, Volume 20, pp. 52-58 (2006). [2] Fernandes M.G., Fonseca E.M.M. and Natal R., Modelo 3D para análise térmica durante o processo de furação do osso cortical, Humberto Varum et al. (Eds), Book of abstracts, 9 th National Congress of Mechanical Experimental, University of Aveiro, 15-17 October, 2014. [3] Bertollo N., Walsh W.R., Drilling of Bone: Practicality, limitations and complications associated with surgical drill-bits, Biomechanics in Applications, Klika, V., (Eds), ISBN: 978-953-307-969-1, 2011. [4] Eriksson R.A., Albrektsson T., Temperature threshold levels for heat induced bone tissue injury: a vital-microscopic study in the rabbit. Journal of Prosthetic Dentistry, Volume 50, pp. 101-107 (1983). [5] Fernandes M.G., Fonseca E.M.M., Natal R., Vaz M. and Dias M.I., Composite Materials and Bovine Bone Drilling: Thermal Experimental Analysis, M2D 2015: 6 th International Conference on Mechanics and Materials in Design, Azores, 26-30 July, 2015, (accepted for publication). [6] Lee J., Ozdoganlar O.B., and Rabin Y., An experimental investigation on thermal exposure during bone drilling, Medical Engineering and Physics, Volume 34, pp. 1510-1520 (2012). [7] Sawbones-Worldwide Leaders in Orthopaedic and Medical Models, Available from: www.sawbones.com (Accessed 11 March 2015). [8] Fernandes M.G., Vaz M., Natal R., and Fonseca E.M.M., Modelo dinâmico 3D para análise térmica em processos de furação óssea, Rui B. Ruben et al (Eds), Book of Abstracts, 6 th National Congress of Biomechanics, Leiria, 6-7 February, 2015. 6

[9] Aerssens J., Boonen S., Lowet G., and Dequeker J., Interspecies differences in bone composition, density, and quality: potential implications for in vivo bone research, Endocrinology, Volume 139, pp. 663 670 (1998). [10] Yuehuei A.H., and Robert D.A., Mechanical testing of bone and the bone-implant interface. New York: CRC Press, pp. 178-179, ISBN: 978-1-4200-7356-0, 2000. [11] Jacob C.H., Berry J.T., Pope M.H., and Hoagland F.T., A study of bone machining process, Journal of Biomechanical Engineering, Volume 9, pp. 343-349 (1976). [12] Fernandes M.G., Fonseca E.M.M., Natal R., and Dias M.I., Temperature Assessment in the Drilling of Ex-vivo Bovine and Porcine Cortical Bone Tissue, BioMedWomen: International Conference on Clinical and BioEngineering for women s Heath, Porto, 20-23 June, 2015, (accepted for publication). [13] Pandey R.K., and Panda S.S., Drilling of bone: A comprehensive review, Journal of Clinical Orthopaedics and Trauma, Volume 4, pp. 15-30 (2013). [14] Karmani S., and Lam F., Influence of thermal effects on hole quality in dry drilling. Part 1. A Thermal model of workpiece temperatures, Current Orthopaedics, Volume 18, pp. 484 90 (2004). 7