Practical Checklists of Best Practices Frank Donovan, W3LPL

Similar documents
A. Product Data shall be provided for each type of product indicated.

SECTION CHAIN-LINK FENCES AND GATES 02821/1

GUY-GRIP Dead-end NOMENCLATURE GENERAL INFORMATION SAFETY CONSIDERATIONS

STANDARD PRACTICE INSTRUCTION

ROOF MOUNT KIT OWNERS MANUAL

SECTION CHAIN LINK FENCES AND GATES (GALVANIZED) A. Fence framework, fabric, gates, and accessories.

SPECIAL SPECIFICATION 8826 Self Supporting Communications Tower (20 to 100 feet)

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

HF Tower Collapse ! We re not the only ones. NSARC HF Operators 1 KFI KRBC-TV

Custom Canopies Intl. Inc.

American Metal Specialties, Inc.

Scaffolding and Raised Platforms

Houston Community College 3200 Main Parking Garage November 15, 2010 Houston Community College

PREPARED FOR: NEW BEDFORD HARBOR DEVELOPMENT COMMISSION FLOATING DOCK CONDITION ASSESSMENT REPORT PORT OF NEW BEDFORD POPE S ISLAND MARINA

KD ANGLE LEG GUYED TOWER McIntosh, ON Report No: 9999 TOWER INSPECTION REPORT

HIGH MAST CAMERA POLE ASSEMBLY GENERAL

Commercial Roof Cover Maintenance and Repair Risk Engineering Your Business Insurance Specialists

STANDARD INSPECTION OF GUY ANCHORS IN DIRECT CONTACT WITH SOIL. Rev: 4/06

02800 SHADE STRUCTURES

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

CHAIN LINK FENCES AND GATES

H 12 Heavy Duty Modern Tripod 8 Seat Swing Heavy Duty Hangers

Single Post Anchor Part Number Spectrum Lane ~ Missoula MT ~

DBI-SALA Uni 8 Overhead Horizontal Lifeline Cable System SECTION HORIZONTAL FALL PROTECTION - OVERHEAD CABLE

EVALUATION REPORT. PFC-5551 Reissued April 1, Filing Category: DESIGN Steel (038)

Pioneer Forced Draft Cooling Tower Specifications

SECTION CHAIN LINK FENCES AND GATES

SECTION SEISMIC CONTROL OSHPD

EVALUATION & REPAIR OF CORROSION DAMAGED ROOF LIFT SLAB WITH WIRE POST-TENSIONING SYSTEM (BUTTON HEADS)

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

SECTION MASONRY ACCESSORIES

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

SECTION ACOUSTICAL PANEL CEILINGS

Model # 158-P4. 12/12/2013 Page 1 of 11

SECTION GROUNDING AND BONDING

SECTION STAINLESS STEEL FLEXIBLE CABLE MESH. Show hidden Specifier Notes for best results

COMMUNICATION STRUCTURES. Delivering Solutions for Your Wireless Tower Needs

Basic Service. This Section provides information regarding a. Introduction

Foundation Manual. Part Number: Version: Updated: July 5, S. Meadows Pkwy. A-9, #329 Reno, NV

Table of Contents. List of Drawings

Model # 800SM-PS3. 8/3/2016 Page 1 of 8

Technical Specification for Live Line Tap Connectors

USER S MANUAL 400W and 600W

NEUTRAL GROUNDING TRANSFORMERS INSTALLATION AND MAINTENANCE INSTRUCTIONS

FACT SHEET #2 DECK INFORMATION

(Condensed from National Electric Code)

DURO-SHIELD ROOF COATING CARE GUIDE TABLE OF CONTENTS

Section 2: Underground

IBC Compliant Seismic Rated Isolators

Model # 922-S4. 12/18/2013 Page 1 of 8

Attachment A-Flagpole(s) Specifications

TYPICAL INSTALLATION INSTRUCTIONS

EXTERNAL GROUNDING (EARTHING)

YOUR SPLASH PAD RESOURCE

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 7

Foundations in Coastal Areas

SECTION PIPE AND TUBE RAILINGS PART 1- GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY 1.3 PERFORMANCE REQUIREMENTS

The Inspection Process. Waxhaw N.C.

CHECKLIST Inspecting a Garage

PREFABRICATED STEEL TRUSS SPECIFICATIONS

SECTION PRE-ENGINEERED MEMBRANE STRUCTURE

John Corini - PE. Key To Successful Tower Installations: Under Stack And Over Guy

Contact Clark Public Utilities Construction Services department at (360) to initiate a request for service.

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

SECTION 1043 FENCE MATERIAL

DUQUESNE UNIVERSITY SAFETY PROGRAM FOR WORKING AT ELEVATED HEIGHTS

SECTION CAST-IN-PLACE CONCRETE

STRUCTURAL MASONRY SPECIAL INSPECTOR. Study Guide

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

SECTION VIBRATION ISOLATION FOR PLUMBING PIPING AND EQUIPMENT

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Douglas County Traffic Signal Installation Guidelines (January 2013)

Electric Service Handbook

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

Note: Any verbiage written in red needs to be specified. All other options should be deleted

SPECIFICATIONS FOR THE INSTALLATION OF REDUCED PRESSURE BACKFLOW PREVENTERS AND CONCRETE VAULTS FOR METERS 4 AND LARGER

Vertigo Cladding Board

RE<C: Heliostat Frame Design

Series 2000HD Heavy-duty pile protection system with marine grade petrolatum tape and an HDPE outercover secured with a bolted system

CONDUITS AND FITTINGS

Universal Panels & Accessories

TYPES OF SEWAGE PUMPS. Solids Handling Pumps: Grinder Pumps: Effluent Pumps:

SECTION PACKAGE BOOSTER PUMP STATIONS

Smarter. Safer. Leaner.

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

The University of Texas at Austin September 30, 2011

PRO-TEC SENTRY BUILDING PONY WALL 90' WIDTH FOUNDATION MANUAL


Stay-Cable Replacement Design

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

Port of Lake Charles RE: 3501 Bayou D Inde Road 200,000 Gallon EWT

SECTION ALUMINUM RAILINGS

TAMPA ELECTRIC COMPANY ENERGY SUPPLY SCAFFOLD PROGRAM

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY AERIAL WORK PLATFORM POLICY 09/06/17 Last Revision

Roughneck Mesh Slings

Typical Deck Details

Specification Lightning Protection Systems

SPECIAL SPECIFICATION 4900 Sacrificial Cathodic Protection Pile Jacket

Transcription:

Design, Construction and Maintenance of Antennas and Towers for Storm Survival and Long Term Reliability Practical Checklists of Best Practices Frank Donovan, W3LPL

Typical A Typical Guyed Guyed Tower Tower and Antenna and Antenna System

Typical Guyed In its Tower Environment and Antenna System corrosive soil

Tower Sections Typical Guyed Tower and Antenna System Design and Construction Checklist Adequate load capacity for current and future use Antenna loads (especially unbalanced or unidirectional) Transmission lines and other cables Adequate load capacity for environmental conditions Wind loads (especially site-specific conditions) Ice loads (especially site-specific conditions) Unidirectional or unbalanced ice and wind loads Corrosion protection (including site-specific needs) Beware of used or corroded tubular tower sections

Tower Sections Typical Guyed Tower and Antenna System Maintenance Checklist Inspect all tower sections one year after installation At least once every three years after initial inspection After all very serious storms After any structural damage to the tower Check plumb and twist of the tower Pay special attention to damaged, loose, missing or corroded: Diagonal and horizontal trusses, welds and hardware Especially near guy attachment points Keep tubular tower weep holes clear of obstructions

Tower Foundation Design and Construction Checklist Use the manufacturer s recommended design Provide adequate depth for local frost conditions The top of the foundation should be 6 inches above grade Tubular tower sections embedded in a concrete foundation require careful attention during construction Each leg must drain into gravel at the bottom of the foundation Concrete embedded tower sections are a risky practice in salt water or industrial pollution atmospheric environments Prevent corrosion at the concrete-to-tower interface

Tower Foundation Maintenance Checklist Inspect at least once every three years Pay special attention to Corrosion at the tower-to-concrete interface Standing water on the foundation Dirt and debris accumulation on the foundation Settling or cracks Dirt and debris accumulation on the foundation can lead to catastrophic tower failure

Guy Anchor Design and Construction Checklist Guy anchor failure is one of the most common causes of catastrophic tower failure Determine if you have corrosive soil conditions in your area Adequate guy anchor depth for local soil conditions Use heavy duty galvanized, forged hardware Use tower manufacturer s recommended guy anchor design Corrosive soils require guy anchor professional design Elevated guy anchors require professional design Do not use light duty home owner grade hardware

Guy Anchor Maintenance Checklist Inspect at least once every three years Dig down at least six inches to inspect for anchor rod corrosion Missing hardware Loose hardware Corroded hardware Anchor rod corrosion is a very serious threat to tower survival

Guy Wire Design and Construction Checklist Use heavy duty galvanized, forged hardware Use tower manufacturer s recommended guy wire size Smaller guy wire risks catastrophic tower failure Heavier guy wire reduces the tower s load capacity Tension the guy wires to 10% of breaking strength Less than 7% risks galloping of the guy wire and excessive tower movement in the wind Greater than 15% risks guy wire vibration and reduced tower load capacity Guy wire vibration dampening hardware may be needed Do not use light duty home owner grade hardware

Inspect three months after initial installation Inspect at least once every three years after initial inspection Inspect after all very serious storms Check guy wire tension (7 to 15% of breaking strength) Check for Damage from rubbing or chaffing of guy wire Corrosion Loose hardware Guy Wire Maintenance Checklist Significantly corroded guys risk catastrophic failure

Guy Attachment (Tower and Anchor) Design and Construction Checklist Guy force must be properly distributed to the tower structure Use the tower manufacturer s recommended design Heavy duty professional grade forged, galvanized hardware Install turnbuckle safety wires Use articulated guy wire connections 10 degrees of free guy wire movement in any direction No chaffing or damage to the guy wire or hardware from frequent tensioning, loosening and movement of the guy wire in the wind Use the manufacturer s recommended guy attachments

Guy Attachment (Tower and Anchor) Maintenance Checklist Inspect at least once every three years Check all guy attachment hardware Missing or loose turnbuckle safety wires Loose, missing or corroded hardware Guy wire chaffing or rubbing Integrity of the tower in the vicinity of the attachments Damaged tower structural components Broken welds Loose or missing hardware Replace all degraded attachment hardware

Lightning Protection Design and Construction Checklist Use at least three ground rods at the tower foundation Separated 20 feet from each other One ground rod at each guy anchor 8 foot galvanized ground rods (10 foot length preferred) Large diameter (2/0) solid, tinned ground wire Rugged, durable connections to the tower and guys Buried connections to ground rods (Cadweld preferred) Buried wire between ground rods and tower foundation Do not use braided ground wire!

Lightning Protection Maintenance Checklist Inspect all ground wire connections at least once every three years Loose or missing hardware Missing wires Broken wires Corrosion Repair all damaged or missing ground wires or connections

Antenna Rotator Design and Construction Checklist Analyze the antenna load capacity of the rotator Use adequate size control wire Consider the total length of the control cable Rotator mounting hardware should be appropriate for the tower Use galvanized steel or stainless steel hardware Use anti-galling compound for stainless steel hardware An under rated rotator will fail prematurely

Antenna Rotator Maintenance Checklist Inspect three months after installation Inspect every three years after initial inspection Check: Excessive mechanical play in the wind Loose or missing hardware Corroded hardware An under rated rotator will be a major maintenance problem

Antenna and Mast Design and Construction Checklist Appropriate antenna and mast for wind and ice conditions Heavy duty or homebrew antenna when needed Use only galvanized or stainless steel hardware Use anti-galling compound for stainless steel hardware Use vibration dampening of antenna elements to avoid premature failure Well designed transmission line connections to the antenna Electrical and mechanical Well designed boom truss with professional quality hardware Select your antenna for local wind and ice conditions

Antenna and Mast Maintenance Checklist Inspect at least once every three years Loose or missing antenna hardware Loose or missing boom truss hardware Corroded hardware Damage from ultra violet radiation Transmission line electrical connection to the antenna Transmission physical connection to the antenna Damaged structural components Transmission line electrical connections to the antenna are often damaged by wind and rain

Transmission Lines and Other Cables Design and Construction Checklist Select appropriate cables local ultraviolet conditions Use appropriate hardware for tower attachment Consider local ultraviolet, wind and ice conditions #12 solid insulated copper wire is a good choice High quality electrical tape (Scotch 88) is a good choice Electrically connect the transmission lines to tower top and bottom of tower Lightning protection of rotator and control cables at the tower base Fasten cables to the tower with high quality attachments

Transmission Lines and Other Cables Maintenance Checklist Inspect at least once every three years Loose, missing or UV damaged cable attachments UV damaged cables Transmission lines, cables and connectors damaged by water intrusion Best inspected by using a time domain reflectometer, VSWR meter or other appropriate techniques Good records are very helpful Failed lightning protection Degraded transmission lines seriously affect station performance

Summary These checklists will help you to avoid common design and construction errors Inspections are an important contributor to long term tower and antenna reliability Conduct major inspections during the first year after construction every three years after initial inspection After very serious storms Inspections are a very important factor in long term tower and antenna reliability