Evaluating Appropriate Residential Ventilation Strategies in Dense Urban Environments and the Challenges for Passive Design

Similar documents
Thermal comfort in a 21st century climate

Designing carbon neutral schools: The Victor Miller Building, a critical review

AIRCOOL VENTILATORS FURTHER INFORMATION

Overheating in homes. An introduction for planners, designers and property owners. Inside: Overheating explained 2. A changing climate 3

Low2No Implementation of sustainable principles after design competition

MODELLING THE IMPACTS OF NEW UK FUTURE WEATHER DATA ON A SCHOOL BUILDING

ASSESSMENT OF INWARD TRAFFIC NOISE IMPACT AT RESIDENTIAL DEVELOPMENT, WONDERFUL BARN, LEIXLIP, CO. KILDARE

VELUX A/S, Daylight Energy and Indoor Climate, Ådalsvej 99, 2970 Hørsholm, Denmark *Corresponding author:

London Prototype House: A Flexible Design Alternative for Accommodating Change

EVALUATION OF THE INDOOR AIR QUALITY IN A SINGLE FAMILY ACTIVE HOUSE

Project Description. Projected build start date 24 Dec 2004 Projected date of occupation. Energy target. Existing external wall construction

Impact of increasing the depth of urban street canyons on building heating and cooling loads in Tel Aviv, Israel

Deakin Research Online

Passivhaus Projects and Benefits

Urban Greening and the UHI: Seasonal Trade-offs in Heating and Cooling Energy Consumption in Manchester, UK

What you need to know about 6 Star. 6 Star. for new homes, home renovations, alterations, additions and relocations

THERMAL MASS CHAPTER 6. Understanding thermal mass. Seasonal effects of thermal mass

SOUTH LANARKSHIRE COLLEGE LOW CARBON TEACHING BUILDING TECHNICAL CASE STUDY

Stage 6 & 7 Design Guidelines

Design Strategies and Guide lines for Tropical Coast of Pakistan, Using Climate Consultant

BRE Bites: Passivhaus Ecobuild 20 th 22 nd March 2012

Compliance to the IgCC. September 29, 2011

Closing the Loop. The use of post occupancy evaluation to inform adaption choices to overheating in Derwenthorpe

Stage 10 Design & Building Guidelines

A STUDY OF DAYLIGHTING TECHNIQUES AND THEIR ENERGY IMPLICATIONS USING A DESIGNER FRIENDLY SIMULATION SOFTWARE

Climate Change Adaptation in London. Alex Nickson, Strategy Manager Climate Change Adaptation & Water, Greater London Authority

INFLUENCE OF HIGH PERFORMANCE FAÇADE ON HEATING/COOLING LOAD IN OFFICE BUILDINGS IN LONDON AND HONGKONG

Design for Noise Mitigation Measures for Public Housing Developments in Hong Kong

Module 3: Simulation and Data Analysis

BRE Lighthouse. 2. Background and Context:

UK-GBC ON SITE LEARNING CASE STUDY EBURY STREET

hard reflecting surfaces close by (such as tall buildings) increasing noise levels by up to 3dB(A)

Optimization of air tightness and night ventilation for Passive houses in Italian climates under Fanger and Adaptive comfort models

ENERGY PERFORMANCE OF DIFFERENT TYPES OF DOUBLE SKIN FACADES IN VARIOUS CLIMATES

Passive Houses in South West Europe

Climat e Change Adaptation in London

Facade Design for Super High- Rise Building in Subtropic Region in China

Lessons from UK Passivhaus projects. - a certifiers view. peter warm CEng BSc MCIBSE MIE

PLANNING SUSTAINABLE IN CHINESE CITIES: DWELLING TYPES AS A MEANS TO ACCESSING POTENTIAL IMPROVEMENTS IN ENERGY EFFICIENCY

EXPLORING THE IMPLICATIONS OF VARIANCE IN URBAN MICROCLIMATE FOR BUILDINGS ENERGY PERFORMANCE: A SIMULATION BASED APPROACH

HELLA Sonnen - und Wetterschutztechnik GmbH. Contribution within the framework of BREEAM certification. Management. Date:

EFA BASELINE DESIGNS ACOUSTICS STRATEGY. Acoustic Design of Schools

TAP-YTL 2010: Sustainable Architecture & Urban Planning

NOISE AND VIBRATION FEASIBILITY STUDY 316 BLOOR STREET WEST CITY OF TORONTO, ONTARIO

Energy-Efficient Passive House using thermal mass to achieve high thermal comfort

Bioclimatic Design Approach Integration into Architectural Design: a Library Case Study

Natural ventilation and acoustic comfort

SOLAR XXI: A Portuguese Office Building towards Net Zero-Energy Building

The content of this supplement is based upon the that described in our letter of May 28, 2012.

Noise Feasibility Study Proposed Residential Development Old Barber House 5155 Mississauga Road City of Mississauga, Ontario

RENOVATIONS & REFURBISHMENTS

PALM TREE RESIDENTIAL AREA / Hanoi, Vietnam

Case Study: Bio-Climatic Building Design for Tropical Climates

General guidelines for using thermal mass in concrete buildings

COMFORT DRIVEN ADAPTIVE WINDOW OPENING BEHAVIOR AND THE INFLUENCE OF BUILDING DESIGN

Paul Tuohy*, Sue Roaf, Fergus Nicol, Mike Humphreys and Atze Boerstra

SUMMER THERMAL COMFORT IN TYPICAL FRENCH RESIDENTIAL BUILDINGS: IMPACT ASSESSMENT OF BUILDING ENVELOPE INSULATION ENHANCEMENT

Assessment of the energy demand in energy-saving office buildings from the viewpoint of variations of internal heat gains

Bioclimatic approaches of modern residential architecture in Cyprus,

Thermal insulation of buildings and cooling demand

Bullitt Center s Energy Performance

Passivhaus Project Documentation Wrexham Passivhaus

Green Building Guideline of Jordan

Building Regulations Part L1A (2006)

Urban Temperature Analysis and Impact on the Building Cooling Energy Performances: An Italian Case Study

Bridging the gap between predicted and actual energy performance in schools

PLANNING DECISION NOTICE

NEED FOR A CORRECT GLASS DESCRIPTIVE CODE: ENERGY-CODING

Rural-Residential Rural-Residential Explanatory Statement Significant Issues Objectives and Policies...

HEAT LOSS REDUCTION OF ENERGY-EFFICIENT HOME BY BUFFER AREAS. Alexander Dvoretsky, KseniaKlevets

Bruck an der Mur. Project summary. Energy concept: Background for the renovation reasons

Student Modeling Competition

Green Building Guideline of Jordan

681: Environmentally Responsive Architecture; Passive Design for School in Southern India

Student Modeling Competition

AIR CONDITIONING ENERGY USE IN HOUSES IN SOUTHERN ENGLAND

FIGURE N-1 LAND USE COMPATIBILITY FOR NEW DEVELOPMENT NEAR TRANSPORTATION NOISE SOURCES

Integration of Energy Efficiency Through Architectural Design. Presentation by TERI. 10 th June,2010

Using passive solutions to improve thermal summer comfort in timber framed houses in South-west France

Achieving Zero Carbon for Buildings in a Densely Populated City and a Subtropical Climate. Guiyi LI Construction Industry Council

Efficient cooling in a natural and energy-saving way. Large volume flows of outside air provide cooling. Intelligent control

Analysis 2: Alternative Thermal Window Design

Double Skin Walls & Dynamic Façades

Noise Assessments for Construction Noise Impacts

OVERALL PERFORMANCE OF VENTILATED DOUBLE FAÇADES COMPARED TO A STATE OF THE ART SINGLE SKIN FAÇADE

Westminster s Energy Challenges and Opportunities. Joe Baker Go Green Programme Manager

Building Concepts for a mid-century energy-neutral society

Work Package 2: Performance of naturally ventilated buildings

MULTI-OBJECTIVE OPTIMISATION OF A MODULAR BUILDING FOR DIFFERENT CLIMATE TYPES. Buro Happold, 17 Newman Street, London, W1T 1PD, UK

POST OCCUPANCY DESIGN INERVENTION TO IMPROVE COMFORT AND ENERGY PERFORMANCE IN A DESERT HOUSE

Existing vegetation with each tree detail like species, girth, canopy etc. Contours with levels Natural features like water body, stream etc.

EFFECTS OF SHADING DESIGN OPTIONS ON THERMAL AND DAYLIGHTING PERFORMANCE OF A MODULAR HOUSE IN MELBOURNE

Assessment of shading devices with integrated PV for efficient energy use

White Paper. A guide to the acoustic performance of Smarts Systems Products. Building Regulations Document E Resistance to the passage of sound

ARPAN JOHARI. Architect. 13/08/10 AW Design. Ahmedabad

ATRIA IN SHOPPING CENTRES, OFFICE BUILDINGS AND HOSPITALS. E.Ph.J. de Ruiter. Adviesbureau Peutz & Associés BV., The Hague, Holland

Place Vanier Édifice AEFO

Proof of Evidence on Noise Helene C S Evans BSc(Hons) MIOA MASA

Thermal Comfort in Architecture

Transcription:

Evaluating Appropriate Residential Ventilation Strategies in Dense Urban Environments and the Challenges for Passive Design Ashley Bateson CEng CEnv MCIBSE MEI Partner, Hoare Lea Chair, CIBSE Homes for the Future Group Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 1

Background Residences are increasingly being built in noisy locations and on challenging plots of land, often resulting in designs for single aspect homes with facades exposed to traffic. At the same time, there is often a drive to provide large areas of glazing in new apartments (perceived as desirable for the residential market) This response can create ventilation challenges and overheating risk. Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 2

Good practice site selection and appraisal of building form Guidance references: CIBSE Guide L (Sustainability), 2007 Site Layout Planning for Daylight and Sunlight: Guide to Good Practice, BRE, 2011 Planning for Sustainable Buildings, Welsh Government, 2014 Engineering a Low Carbon Built Environment, The Royal Academy of Engineering, 2010 Assessing site opportunities and constraints (Source: CIBSE Guide L Sustainability) Overheating in Homes: An introduction for planners, designers and property owners, NHBC 2012 Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 3

London planning guidance Developments should minimise the need for active cooling systems and consider natural means of maintaining comfort (London Plan policy 5.9) Passive design 1. Minimise internal heat generation through energy efficient design 2. Reduce summer heat gains: orientation, shading, albedo, fenestration, insulation, green roofs / walls COOLING HIERARCHY 3. Exposed internal thermal mass and high ceilings 4. Passive ventilation 5. Mechanical ventilation Active design 6. Active cooling systems (selecting the lowest carbon options) Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 4

Busy London high street 100 years ago Camden High Street c.1904 Electrified tram in Camden, c. 1910 Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 5

The same street now Challenges for residential ventilation in urban locations: Traffic noise Retail activity Air conditioning units Urban heat island effect / warmer climate Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 6

Glazing proportions in modern apartments can be > 50% of the façade Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 7

Glazing proportions in older buildings generally < 35% of the facade Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 8

Urbanisation increases the density of residential development Manchester skyline Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 9

Traditional apartment design enables cross-flow ventilation Site plan showing courtyard Street elevation Courtyard elevation Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 10

Climate change: Ranking the hottest years since 1850 shows that most of the hottest years have occurred in the last 10 yrs. Average temp. changes: Approx. 0.5 C increase since 1950s Approx. 1.0 C increase since 1850s Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 11

Cities in particular, are getting hotter Summers are getting drier and warmer More extreme weather conditions occur Hyde Park in the summer Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 12

Future trends in peak temperatures - Predictions for different emission scenarios Maximum temperatures could rise by at least 2 C by 2050s Worst in southern England Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 13

Future evening temperatures will reduce opportunities for night cooling Evening temperatures could increase by 3 C by 2050s Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 14

Overheating criteria for residential design CIBSE Residential Summer Peak temperatures (CIBSE Guide A) Assessed by dynamic thermal model Building type Dwellings - Living Areas Benchmark summer peak temp 28 C Passivhaus Overheating Criteria Overheating criterion Not to exceed 28 C operative temp for more than 1% annual occupied hours - Bedrooms 26 C Not to exceed 26 C operative temp for more than 1% annual occupied hours Minimum Acceptable Overheating Criterion Not to exceed 25 C air temp for more than 10% of total annual hours Preferred Overheating Criterion Not to exceed 25 C air temp for more than 5% of total annual hours Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 15

Acoustic criteria for residential design Recommended acoustic criteria for residential design are provided by BS8233 (Sound Insulation and Noise Reduction for Buildings Code of Practice) Activity Internal space 07:00 to 23:00 23:00 to 07:00 Resting Living Room 35dB L Aeq,16hour - Dining Dining Room 40dB L Aeq,16hour - Sleeping (daytime resting) Bedroom 35dB L Aeq,16hour 30dB L Aeq,8hour It should be noted that high noise levels can cause anxiety and affect sleeping patterns for occupants. (Ref. Overheating evidence review, Zero Carbon Hub, 2015) Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 16

MVHR performance gap issues References highlighting industry problems with MVHR installations and operation: Preventing Overheating: Investigating and reporting on the scale of overheating in England, including common causes and an overview of remediation techniques, Good Homes Alliance, 2014 Overheating in new homes: A review of the evidence, NHBC & ZCH, 2012 Performance Gap Issues: Final Report, Zero Carbon Hub, 2014 Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 17

Summary of challenges for urban residential developments Site location and building form: Homes developed at busy sites with high external noise levels Single aspect apartment layouts with no opportunity for cross-flow ventilation Small dwelling sizes (solar and internal heat loads can become significant) Lightweight construction Window configuration: Highly glazed Often lack of openable windows, or windows won t open fully Mechanical ventilation / Building services: Increasing dependency on MVHR systems MVHR performance gap issues: low air flow rates and poor maintenance Internal heat gains from communal heating systems (with corridor distribution 24 hrs/day) Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 18

Case study Analysis of an apartment block adjacent a busy road Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 19

Case study description The project is a multi-storey apartment block with two elevations facing busy roads. External noise levels measured by acoustic survey: 65 db(a) to 72 db(a). Due to high external noise levels opening windows for background ventilation and comfort should be kept to a minimum. Acoustic implications for apartments facing the streets: Partially open window (10-15 db reduction) => approx. 50-60 db inside apartment Closed window (35-40 db reduction) => 30-35 db inside apartment All apartments designed to have MVHR unit and openable windows for purge ventilation (for Building Regulation Part F compliance and occupant control) Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 20

Description of Overheating Assessment A CIBSE Guide A overheating assessment was undertaken using dynamic thermal modelling software: TAS (EDSL) v 9.2.1.3. The 2005 CIBSE weather data for London Heathrow Design Summer Year (DSY) was used. The baseline scenario includes a standard MVHR unit in the apartments with the flow rates: 18l/s for small living rooms/ bedrooms and 30l/s for larger living rooms/ larger bedrooms. In order to assess the opportunity to reduce overheating risk a larger MVHR unit was considered, with higher flow rates: 60l/s for small living rooms, 100l/s for larger living rooms and 36l/s for bedrooms. The larger MVHR unit scenario was assessed with and without external shading (The external shading comprised external louvres at 45 angles). External louvres were introduced to mitigate overheating risk Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 21

Results - Natural ventilation scenario with standard MVHR units and no external shading Low overheating risk but opening windows create unreasonable noise levels in the apartments due to external traffic noise N Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 22

Results - Larger MVHR scenario with no external shading Apartments showing some overheating risk Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 23

Results - Larger MVHR scenario with external shading added The addition of the external shading has resulted in fewer apartments showing overheating risk. Some apartments still show some residual overheating risk. This can be mitigated be further increases in the ventilation rates and other measures. Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 24

Conclusions of case study 1. Natural ventilation (using openable windows) is not suitable at the site, given the high levels of traffic noise, although the modelling shows it would be effective in minimise overheating risk. 2. Standard MVHR ventilation rates are insufficient to avoid overheating risk at the site. 3. Higher MVHR ventilation rates reduce overheating risk when combined with external shading. The recommended solution comprises: Large MVHR unit with high ventilation rates External shading Openable windows for purge ventilation Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 25

Lessons from abroad - examples of solar shading techniques Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 26

Lessons from abroad passive construction techniques Good practice examples from Mediterranean housing: Thermal mass Reflective surfaces Smaller windows Optimised building form Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 27

Examples of shading in recent UK projects Timber Wharf, Manchester Art House, Kings Cross Hanham Hall, Bristol Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 28

Key lessons and future issues 1. An early review of external noise and ventilation strategies will become increasingly important, especially as dwellings are being planned adjacent busy roads and other noisy sites. 2. Natural ventilation strategies may be unacceptable from an acoustic perspective. MVHR is increasingly likely to be the future solution 3. The use of external shading, light coloured facades, thermal mass and smaller areas of glazing should be evaluated as passive strategies to complement the MVHR system. 4. Dynamic thermal modelling is a useful tool to test the impact of passive measures at the pre-planning stage. 5. MVHR performance gap issues need to be resolved (better installation, testing, commissioning and maintenance etc.) 6. Impact of the future climate conditions, adaptation and microclimate will be increasingly important (including the urban heat island effect) Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 29

Thank-you Any questions? ashleybateson@hoarelea.com Ashley Bateson / Residential ventilation and challenges for passive design Rev. B / April 2015 30