Viking Enviroclad Waterproofing Membrane. EC01 Enviroclad Drip Edge Specify from the above three options

Similar documents
Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

Viking dec-k-ing. membrane. Product. BRANZ APPRAISAL No. 411 (2011) Scope. Appraisal No.411 [2011] BRANZ Appraisals

nu-wall direct fixed Product BRANZ APPRAISAL No. 557 (2007) Scope Aluminium Product Brands NZ Limited 15 Gabador Place Mt Wellington Auckland

SS806 StoStucco Roughcast System 1

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only)

ALLMET CONTINENTAL INSTALLATION GUIDE

Trims for flat roofing. GRP Trims for flat roofing

GRP Flat Roofing Edge Trims

Plastercrete. Drained & Ventilated AAC Facade System Design and Installation Guide 100% NZ OWNED. plastercrete.co.nz.

SECTION TURBINE VENTILATORS

Roofgard Paving Support System

SECTION RESILIENT SHEET FLOORING

BENCHMARK Evolution Axis

RUBBERGARD EPDM SA APPLICATION GUIDE

PREFA Aluminiumprodukte GmbH Page 1 of 25

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

HIDDEN HOLES IN WOOD FRAMED BALCONY WATERPROOFING

AQUABLOK INTERIOR WATERPROOFING MEMBRANES. Product. Scope. Appraisal No. 724 [2017]

ELEVATION FOR DETAIL REFERENCE ONLY

PREFA Aluminiumprodukte GmbH Page 1 of 21

NOVAFLEX AND POLIBIT ROOF AND DECK WATERPROOFING MEMBRANES. Product. Scope. Appraisal No. 520 [2013] Appraisal No. 520 (2013) Amended 02 March 2016

DUKE UNIVERSITY CONSTRUCTION STANDARDS

Insulating systems used in agricultural and industrial buildings

WORK BELOW LOWEST FLOOR FINISH 1/7 230, , , FRAME 2/6 96, , ,056.00

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

SITE VISIT REPORT DATE: JOB: NO. OF VISIT: PAGE OF : PURPOSE OF VISIT: CONTRACTOR: Items to be checked Observations Actions SETTING OUT

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Waterproofing Handbook

How do you install yours?

Construction details:

BUILD A SHOWER CUBICLE

RS32 Multi-Section Skylight System under/over seam clip double diverter

Balconies Information. How to waterproof and reduce efflorescence

ELEVATION FOR DETAIL REFERENCE ONLY

Finestone Stucco Ultra Wall System

KS SERIES - VERTICAL INSTALLATION

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

Chapter 2 Understanding The Problem

SI T T FST

Sub-construction for Wall-mounted Longlight

Finestone Stucco System

EXT.CORNER - MANUF.STONE/FC SHEET

Built to Last a Lifetime

Senturion TM III Wall System

Rediflow Concrete Gas Flue System

Lithia Dodge East 5500 L St. Omaha, NE

SECTION PLATE CONNECTED WOOD TRUSSES

External Thermal Insulation Composite System Insulation below ground level

RS24-10 Single-Section Skylight System

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DuPont RainVent Batten Installation Guidelines

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

The HardieZone System: HZ5 Care and Maintenance Guide

Administrative Changes

RUUKKI FORMA DESIGN INSTRUCTION

Examples of Installation Method

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

BEAL Appraisal Certificate The PLASTERCRETE AAC Wall Panel System

Nouveau BBQ Single Flue

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper

e x a n g l e installation guide exangle Finishing Sections

Compliance Document for New Zealand Building Code Clause E2 External Moisture

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

A. Product Data: Submit manufacturer s product data, with complete general and specific installation instructions, recommendations, and limitations.

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

Kingspan Day-Lite Klick

11 FLAT ROOF CONSTRUCTION

MIGUTAN FP110 (Previously FP 90, name changed as part of metric standardization program)

NOTES FROM THE FIELD FLAT ROOFS AND MASONRY IN NEW YORK PETER MARCIANO

AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW.

FLUID APPLIED WATERPROOFING

MULE-HIDE PRODUCTS CO., INC. MULE-HIDE SELF-ADHERING TPO ROOFING SYSTEM

ELEVATION FOR DETAIL REFERENCE ONLY

TW50. Insulation STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY. Low Energy Low Carbon Buildings. Wall lining. Inner leaf blockwork

SECTION METAL BUILDING SYSTEMS

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

Modular Buildings. Installation Manual

SWING DOOR SPECIFICATION

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms.

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels.

TC54. for architects & designers. Dimensions Clearances Venting

REV:6-30/09/30. Liquid Rubber Timber Specification

When I started tiling, we didn t do our own shower pans that BATHS

HYDRATHANE INTERIOR WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 959 [2017] Appraisal No. 959 (2017) BRANZ Appraisals

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

Radon Vent Pipe System. Labeling Performance Indicators

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description

SECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD

Transcription:

*lum ngle 50x50x1.6mm min. with 20mm lum fixing bar to mechanically secure membrane Enviroclad Waterproofing Membrane Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from www.vikingroofspec.co.nz B *lum ngle 50x50x1.6mm with SMT076V Laptape to seal Enviroclad to drip-edge C * Refer NZBC Clause E2 Table 21 for Metal ngle compatibility with CC treated timber. If required use separation layer between materials TPO coated Galv ngle 50x50x.55mm Enviroclad can be welded to drip-edge for a secure termination EC01 Enviroclad Drip Edge Specify from the above three options EC01

230mm 230mm Clamped Drain or Overflow SDM049 80mm flowrate 3.2Lts/sec 100mm flowrate 5 Lts/sec Outlet Overflow Note: 1/ Overflow to match outlet capacity. 2/ Overflow to be plumbed independent of stormwater, through soffit or exterior wall EC02 Enviroclad Dropper Outlet and Overflow EC02

It is Roofspecs view that Internal Gutters can be eliminated in most cases. In doing so you may Reduce overall heights or increase roof falls while reducing risk and detail. To find out more contact Roofspec Technical 0800 729-799 *E2/S1 Min. falls for gutters = 1:100 40mm Weld Enviroclad Waterproofing Membrane 40mm Weld Minimum 5mm Radius to all external edges SDM049 Drain or Overflow 80/100mm Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from www.vikingroofspec.co.nz * pply cut edge sealant to all cut edges of reinforced membrane. * No fillets required with Enviroclad. EC03 Enviroclad Internal Gutter EC03

Optional Head-flashing to prevent water over fixings Generic Rainhead TPO Scupper Enviroclad Waterproofing Membrane sealant and tape by builder 4mm rebate for scupper Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from www.vikingroofspec.co.nz EC04 Enviroclad Scupper Outlet EC04

Enviroclad Waterproofing Membrane Consider keeping floodheight of membrane above the parapet, eliminating the possibilty of water ingress under the metal roof 'Z' Scupper Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from www.vikingroofspec.co.nz 'Z' = variable according to wind zoning. please refer to table 7 E2/S1 * Gutters must be sized to E2/S1 paragraph 8.5.10 please refer to fig 64b & 64c E2/S1 * ll external corners must be have a minimum 5mm radius. * The membrane must extend across the top of the parapet and down the outside of the parapet. * The top of the parapet substrate, must be angled to allow water to run off the top of the parapet. * ll fixings for the cap flashing, must be through the side of the flashing. * pply cut edge sealant to all cut edges of reinforced membrane. * No fillets required with Enviroclad. EC05 Enviroclad Parapet Gutter EC05

Enviroclad Waterproofing Membrane Clamped drain as overflow through Parapet SDM049 Clamped Drain or overflow 80mm / 100mm through base of gutter SDF110 Fixing Bar only required if not using a Parapet Cap Sealant to cladding Outlet flange 231mm 75mm Generic Rainhead Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from www.vikingroofspec.co.nz * pply cut edge sealant to all cut edges of reinforced membrane. * No fillets required with Enviroclad. EC06 Enviroclad Parapet Gutter / Outlet / Overflow EC06

SDF110 Fixing Bar only required if not using a Parapet Cap Clamped drain as overflow through Parapet Sealant to cladding by builder Enviroclad Waterproofing Membrane 75mm EC07 Enviroclad Overflow through Parapet EC07

Enviroclad Waterproofing Membrane Fixing Bar SDF110 Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from www.vikingroofspec.co.nz Enviroclad Waterproofing Membrane Fixing Bar SDF110 EC08 Enviroclad Barge Edges with Fastening Bar EC08

RB Flashing Tape non-bituminous Min. 150mm as per E2/S1 Enviroclad Waterproofing Membrane Min. 150mm as per E2/S1 EC09 Enviroclad Wall Upstands behind Cavity EC09

Note: Roofspec would only advise using a pressure bar detail where a Chase detail is not practical sealant STP860 SDF110 Fixing Bar with STP870 water cut-off mastic sealant between membrane and wall for a compression seal Chase Flashing and sealant by Main-Contractor SDF110 Fixing Bar with STP870 water cut-off mastic sealant between membrane and wall for a compression seal 'Z' Minimum upstand 150mm Minimum upstand 150mm 'Z' Enviroclad Waterproofing Membrane Enviroclad Waterproofing Membrane 5mm 5mm Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from www.vikingroofspec.co.nz EC10 Enviroclad Chase or Face Upstand EC10

Finish Membrane 100mm min. up framing at ends Finish Membrane 100mm min. up framing at ends Interior floor level lum joinery Min. 100mm as per E2/S1 Enviroclad Waterproofing Membrane 1.5mm thickness for decks Min. 100mm as per E2/S1 5mm Gap 5mm Gap Note: recommend a trafficable overlay system is installed over all membrane deck types other than Dec-K-ing EC11 Enviroclad 100mm Door Threshold to deck EC11

Metal Cap Flashing to allow for movement Enviroclad Waterproofing Membrane 150mm Seismic Gap determined by designer Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from www.vikingroofspec.co.nz EC12 Enviroclad Construction Joint EC12

Pitched Roofing. Longrun 150mm 150mm 2 fall Pitched Roofing Tiles Finish membrane to 150mm minimum vertical height from high point of the membrane roof. Support mermbrane under pitched roofing with flood-board 2 fall EC13 Enviroclad Membrane to Pitched roof Transition EC13

DryLight skylight lum frame / clear glazing Enviroclad Waterproofing Membrane Min. 150mm Upstand as per E2/S1 * pply cut edge sealant to all cut edges of reinforced membrane. * No fillets required with Enviroclad. EC14 Enviroclad Skylight upstand EC14

Minimum 40mm Weld 150mm Minimum Enviroclad Waterproofing Membrane Enviroclad Moulded External Corner Fully welded Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from www.vikingroofspec.co.nz EC15 Enviroclad External Corner * pply cut edge sealant to all cut edges of reinforced membrane. EC15

Min. 40mm Weld Enviroclad Waterproofing Membrane Enviroclad Moulded Internal Corner Fully welded 150mm Minimum Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from www.vikingroofspec.co.nz * pply cut edge sealant to all cut edges of reinforced membrane. all cut edges EC16 Enviroclad Internal Corner EC16

Cladding underlay 150mm TPO Corner Diverter welded to Enviroclad base and upstand Enviroclad Waterproofing Membrane continue past drip edge by 150mm under cladding and cavity Enviroclad Waterproofing Membrane 150mm EC17 Enviroclad Kick-out Diverter EC17

Wall Underlay and cladding cover membrane upstand min. 115mm 150mm TPO Corner Diverter welded to Enviroclad base and upstand Enviroclad Waterproofing Membrane 150mm Drip-edge termination Bar EC18 Enviroclad Kick-out Diverter EC18

Enviroclad Waterproofing Membrane Laptape SMT076V Metal Roofing Metal Ridge Flashing refer NZBC E2/S1 table 7 for dimensions and table 21 for materials compatibility 'Z' 'Z' = variable according to wind zoning. please refer to table 7 E2/S1 EC19 Enviroclad to Mansard Roofing Junction EC19

104mm TPO Cavity Vent STP607 Grey only (with Black Cap) How many vents? recommends 1 vent per 50m2 area. Ensure cross ventilation between timber supports. Note: Venting not required if specifying Warmroof or WarmSpan systems 250mm lum Cavity Vent IMV111 Grey IMV112 White 215mm 310mm TPO Pipe Seal 25mm - 225mm Enviroclad Waterproofing Membrane Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from www.vikingroofspec.co.nz EC20 Enviroclad Cavity or substrate Vents EC20

Note: Membrane is suitable to be installed to flue outer-liners reaching temperatures up to 60 C. Pipe overflashing by plumber or flue supplier Sealant STP870 Water Cut-off Mastic Stainless Steel Hose clamp Enviroclad Waterproofing Membrane Enviroclad Non-Reinforced Membrane Heat welds EC21 Enviroclad Oversized Pipe or Flue Penetration EC21

Goose-neck allowing wiring or conduit to be passed through Pipe over-flashing by plumber Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from www.vikingroofspec.co.nz Sealant STP870 TPO pipe seal 25mm - 225mm welded to Enviroclad Waterproofing Membrane EC22 Enviroclad Pipe Penetration Showing Goose-neck for ir-con Conduit EC22

Round Support post brackets Wall Mounted Bracket Enviroclad with welded strip to shroud bracket fixings Beam to span from post supports Enviroclad Waterproofing Membrane Min. 100mm Plant Mount support bracket Fixed to round post above waterproofing detail Beam to span from post supports Wall Mounted Steel Bracket to support beam Round support post welded to flat plate which is to be bolted to the main structure under the substrate EC23 Enviroclad Plant Mounting Posts or Wall supports NOTE: Brackets to be manufactured specific to requirements and spaced according to Plant weight and beam spanning abilities 01/12/2016 EC23

solution for very difficult shaped penetrations. Note that all surfaces in contact with Pourable sealant must be primed with SEC034 Lap primer. This includes all pipes, bolts, brackets and TPO sealant surround. For specific requirements contact Roofspec for advice Example Bracket STP460 Pourable sealant White only must be min. 25mm of sealant around all surfaces Enviroclad Pourable pocket surround heat welded to membrane sheet Enviroclad Waterproofing Membrane Multiple penetrations must be Min. 25mm apart Example: square post minimum 25mm minimum 25mm EC24 Enviroclad Pourable TPO Pockets EC24

Consider Detail EC23 as a better option for supporting Mechanical Plant on membrane roofs. lthough Roofspec do not recommend fixing posts or plant through the top of Membrane roofs or decks if this is required then use of a plinth detail provides that fixings by other trades are keep off the main deck flood area. Roofspec recommend that any fixing of plant is kept independent of the membrane roof ideally through vertical surfaces such as parapets. ll fixings must be sealed. Note: Roofspec or our pproved pplicators do not warranty fixings installed by other trades. Bracket / Bolt with compression washers both sides of bracket. By others 40mm Weld SMT076V Laptape to seal 40mm Weld Plywood to comply with current Roofspec Masterspec specification EC25 Enviroclad Plinth Details for fixing of mechanical plant by others EC25

Square post through deck Timber Moulding installed by builder Overflashing membrane upstand Enviroclad Waterproofing Membrane Enviroclad Moulded External Corner Min. 100mm Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from www.vikingroofspec.co.nz EC26 Enviroclad Square Post through Deck EC26

Enviroclad Waterproofing Membrane Enviroclad TPO Batten Welded directly to Enviroclad TPO membrane, no penetrations. Battens can be placed at any point along the roof as long as they don't inhibit watershed 25mm Heat weld 35mm EC27 Enviroclad TPO Welded Batten STP219 EC27

STEP 4. Cladding to seal to saddle flashing *NOTE: refer further advise from E2/S1 fig12 for saddle detail STEP 1. Enviroclad behind cavity batten fully supported by substrate Finish 150mm min. cover over & beyond the parapet junction STEP 3. *Saddle Flashing over cavity batten, directly behind cladding, refer Fig12 E2/S1 50x50mm Internal-corner Flashing by cladding supplier Behind saddle flashing extended to bottom of cladding. STEP 5. Metal Cap flashing to seal to saddle flashing Waterproofing membrane to detail over cladding 50mm 50mm 5 Sealant Bead x 2 for Parapet Cap 50mm Waterproofing membrane EC28 Enviroclad Parapet Junction Methodology EC28

3 SDM057 80mm PVC llthrough Deck Drain SDM058 100mm PVC llthrough Deck Drain 45 55.6 25.4 6 55 76.2 50.2 83 133 180 104 110 266.8 Balcony Drains llproof llthrough Multi-deck Drains 23/3/2016 Drainage

280 230 Outlet or Overflow SDM049 80mm / 100mm 121 Outlet or Overflow SDM051 150mm 121 80mm insert Note requires approx. 300mm depth to fit a 100mm 88 bend to dropper SDM055 80mm side exit Drain or Overflow 100mm depth SDM056 80mm side exit deck drain 100mm depth Note requires approx. 240mm depth to fit an 80mm 88 bend to dropper 230 38mm Retain Collar to use as an Overflow Deck Drain SDM050 refer SDM049 for dimensions Note: Metal components are 304 Grade Stainless Steel 100mm depth 230 Flowrates in Litres / Sec SDM051 150mm = 7.6 SDM049 80mm/100mm = 3.26/5.09 SDM050 80mm/100mm = 3.26/5.09 Clamped Drains and Overflows quaknight 23/3/2016 Drainage