FUZZY LOGIC APPROACH TO REACTIVE POWER CONTROL IN UTILITY SYSTEM

Similar documents
International ejournals

ANALYSIS OF THE BEHAVIOR FOR REACTIVE POWER COMPENSATION USING SVC CONTROLLED HYBRID SOLAR/WIND POWER GENERATING SYSTEMS

CSIRO CLUSTER PROJECT #3

Thermal Unit Commitment Strategy Integrated with Solar Energy System

Multi-Objective Allocation of DG Simultaneous with Capacitor and Protective Device Including Load Model

Mitigation of Voltage Fluctuations in Power System Using STATCOM

Economic Load Dispatch Solution Including Transmission Losses Using MOPSO

Refinement of Hydel power by implementing FACTS at Narangwal hydroelectric power plant

DETERMINATION OF PRICE OF REACTIVE POWER SERVICES IN DEREGULATED ELECTRICITY MARKET USING PARTICLE SWARM OPTIMIZATION

The Effect of the Volt/Var Control of Photovoltaic Systems on the Time-Series Steady-State Analysis of a Distribution Network

POTOMAC ELECTRIC POWER COMPANY

A Fuzzy Optimization Model for Single-Period Inventory Problem

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 3, Issue 5, November 2013

PSO Based Optimal Control for Maximizing PV Penetration at Transmission Level

ELECTRIC ARC FURNACE WITH STATIC VAR COMPENSATOR PLANNING AND OPERATIONAL EXPERIENCE

IEEE TRANSACTIONS ON POWER SYSTEMS, VOL. 26, NO. 3, AUGUST

Power Flow Control Scheme for Wind Energy Conversion System

A Study of Uncertain Wind Power in Active-Reactive Optimal Power Flow

MINIMIZATION OF ELECTRICITY CONSUMPTION COST OF A TYPICAL FACTORY

Large-scale Wind Power Integration and Voltage Stability Limits in Regional Networks

Performance Improvement in Distribution Network with DG

Centralized wind power plant voltage control with optimal power flow algorithm

Application of Intelligent Methods for Improving the Performance of COCOMO in Software Projects

Consequence and Impact of Electric Utility Industry Restructuring on Transient Stability and Small-Signal Stability Analysis

PSS E. High-Performance Transmission Planning Application for the Power Industry. Answers for energy.

Dispatch Signal & Locational Marginal Pricing (LMP)

SOLUTION TO AN ECONOMIC LOAD DISPATCH PROBLEM USING FUZZY LOGIC

Technical Bulletin Comparison of Lossy versus Lossless Shift Factors in the ISO Market Optimizations

Multi-Agent Model for Power System Simulation

MOD Data for Power System Modeling and Analysis

Applying RFID Hand-Held Device for Factory Equipment Diagnosis

IN MANY countries all over the world the power industry

Procedia - Social and Behavioral Sciences 109 ( 2014 )

Power System Economics and Market Modeling

Power Quality Assessment of Large Motor Starting and Loading for the Integrated Steel-Making Cogeneration Facility

Multi-Objective Generation Scheduling with Hybrid Energy Resources

Outcomes and recommendations GREDOR

3. PROPOSED MODEL. International Journal of Computer Applications ( ) Volume 103 No.9, October 2014

Value-based Transmission Investment and Operations. Marija Ilic Invited Panel, IEEE PES 2014 Washington DC

A Fuzzy Multiple Attribute Decision Making Model for Benefit-Cost Analysis with Qualitative and Quantitative Attributes

Power quality improvement by using STATCOM control scheme in wind energy generation interface to grid

Sustainable sequencing of N jobs on one machine: a fuzzy approach

Deregulation, Locational Marginal Pricing, and Critical Load Levels with Applications

A comparative study of ASM and NWCR method in transportation problem

Distribution System Operator (DSO) Construct as a Bridge for End-to-End Transactive Operation

Facility Interconnection Requirements

EVALUATING INVESTMENT DEFERRAL BY INCORPORATING DISTRIBUTED GENERATION IN DISTRIBUTION NETWORK PLANNING

Joint DSO TSO reactive power management for an HV system considering MV systems support

Standard PRC-002-NPCC-01 Disturbance Monitoring

ECONOMIC LOAD DISPATCH USING GENETIC ALGORITHM AND PATTERN SEARCH METHODS

Standard TPL Transmission System Planning Performance Requirements

Volatility Prediction and Management by Active Network Management & Future Generation Management. Siemens, Sept 8 th 2017

Stock Market Prediction with Multiple Regression, Fuzzy Type-2 Clustering and Neural Networks

Measurement and Control of Coal Pipe Temperature of Coal Mills of PF Boiler

Research and Application Study on Accident-Based 3D Power Station Simulation Technology

EDF and Integration of Distributed Energy Resources

Shunt and series reactors for medium- and high-voltage grids siemens.com/transformers

Application of genetic algorithm for optimal sizing and placement of distribution transformers in PT PLN East Medan Indonesia

A. Panagoda, K.T.M.U. Hemapala and N. De Silva

Locational Marginal Pricing (LMP): Basics of Nodal Price Calculation

Ergon Energy Corporation Limited

EVALUATION THE PERFORMANCE AND IMPLEMENTATION OF FUZZY LOGIC CONTROLLER IN STEAM TURBINE OF THE THERMAL POWER PLANT

Information Systems in Organizations. Decision Making. Mintzberg s five 5 organizational parts. Types of Organizations.

California Independent System Operator Corporation Fifth Replacement Electronic Tariff

EE 741. Load Characteristics

POWER SYSTEM STABILITY GUIDELINES

IEEE TRANSACTIONS ON POWER SYSTEMS, VOL. 22, NO. 4, NOVEMBER

Educating System Operators in the New Millennium! Background. Course Level. Target Audience. NERC Continuing Education Hours

PERMANENT MAGNET SYNCHROUNOUS GENERATOR WIND TURBINE PITCH ANGLE CONTROL BY FUZZY AND PID CONTROL

Condition Assessment of Power Transformer Using Dissolved Gas Analysis

HCTL Open Int. J. of Technology Innovations and Research HCTL Open IJTIR, Volume 2, March 2013 e-issn: ISBN (Print):

A Traditional Approach to Solve Economic Load Dispatch Problem Considering the Generator Constraints

FIS Based Speed Scheduling System of Autonomous Railway Vehicle

IMPROVEMENT IN MICROGRID DUE TO RENEWABLE ENERGY SOURCES IN DISTRIBUTED GENERATOR NETWORK

ENABLING EMBEDDED GENERATION

Economic Design of Reinforced Concrete Columns under Direct Load and Uniaxial Moments

CERTS Microgrids. Tom Jahns Professor, University of Wisconsin-Madison. LPPC Rates Roundtable May 21, 2013

Simulation of Container Queues for Port Investment Decisions

BUFFER EVALUATION FOR DEMAND VARIABILITY USING FUZZY LOGIC

SERVICE AGREEMENT. For. Network Integration Transmission Service. Between. The City of Wauchula, Florida (Transmission Customer) And

2750 Monroe Blvd Audubon, PA

Slide 1. ABB August 23, 2016

2.000 SGB-SMIT AT A GLANCE YEARS OF EXPERIENCE COUNTRIES EMPLOYEES PRODUCTS READY FOR YOUR MARKET. More than. Combined, more than.

GRID CODE COMPLIANCE TESTING OF RENEWABLES NEW REQUIREMENTS AND TESTING EXPERIENCES

A Bayesian Approach to Operational Decisions in Transportation Businesses

Hierarchical Frequency Control Scheme for Islanded Multi-Microgrids Operation

OPTIMIZING DEMAND FULFILLMENT FROM TEST BINS. Brittany M. Bogle Scott J. Mason

Business Information Systems. Decision Making and Problem Solving. Figure Chapters 10 & 11

GENETIC ALGORITHMS. Narra Priyanka. K.Naga Sowjanya. Vasavi College of Engineering. Ibrahimbahg,Hyderabad.

Con Ed/PSEG Wheel Replacement Proposal A joint white paper from the New York Independent System Operator and PJM Interconnection

Classical Approach to Solve Economic Load Dispatch Problem of Thermal Generating Unit in MATLAB Programming

Optimal Scheduling Strategy in Insular Grids Considering Significant Share of Renewables

Visualization for Shipboard Power Systems

A Fuzzy Inference System Approach for Knowledge Management Tools Evaluation

Impact study of PV integration in Bornholm power system

An Improved Genetic Algorithm for Generation Expansion Planning

LOADING AND SEQUENCING JOBS WITH A FASTEST MACHINE AMONG OTHERS

New method for assessment of raters agreement based on fuzzy similarity

Modeling of the Dynamic Behavior of the Island Power System of Cyprus

Transcription:

FUZZY LOGIC APPROACH TO REACTIVE POWER CONTROL IN UTILITY SYSTEM Mr. C. Ramesh Dr. M. Rajaram (Corresponding author) Vice-Chancellor, Research Scholar, Anna University of Technology, Anna University of Technology Coimbatore, Tamil Nadu, India Tirunelveli, Tamil Nadu, India Mobile No: +91 8861950333 Mobile No: +91 9942227799 Fax: +91 4259 236070 Office: +91 4622 554255 crameshpandian@rediffmail.com rajaramgct@rediffmail.com Dr. S. Chenthur Pandian Principal, Dr. Mahalingam College of Engineering and Technology, Tamil Nadu, India Mobile No: +91 98423 04203 Fax: +91 4259 236070 chenthur@rediffmail.com Abstract: The reactive power control has become particularly important concern for maintaining the voltage level for utility transmitting power over long distances. To maintain the voltage level at various buses either the reactive power is injected or absorbed. In this paper the load and the voltage level are considered as two inputs and the reactive power is taken as an output. The input variable load has been divided into five triangular membership functions. Another input variable voltage has been divided into three triangular membership functions. The required reactive power value as an output has been divided into five triangular membership functions. Case studies have been performed for State Electricity System (SES) which is known as the utility system in this paper. For this SES four generating stations have been considered in this paper. For all these cases the reactive power requirement are calculated by using fuzzy logic approach. This fuzzy based reactive power requirement values are compared with the conventional controller values. It is observed that the reactive power requirement by fuzzy approach is lower than the conventional method. Practical calculation and results are taken for simulation which has been performed by using the developed software in MATLAB package. Keywords: Expert Systems, Fuzzy, Linguistic, Membership Functions, Reactive Power, Unified Power Flow Controller (UPFC), Compensators 1. Introduction The quality of power supply is decided by the level of voltage and frequency. Maintenance of the voltage in various buses within the tolerable range is an important aspects in the power systems. The voltage level is maintained by using suitable reactive compensating devices and UPFC at the desired location. The voltage controllers are connected on line so that we can program the voltage controller / reactive power controller setting according to daily reactive power dispatch schedules. The reactive power / voltage control should be fast for on line application, flexible for charging systems conditions and easy to comply with operator s decision making logic. Fuzzy logic technology has achieved impressive success in diverse engineering applications ranging from mass market consumer product to sophisticated decision and control problems. Uncertainty in fuzzy logic typically arises in the form of vagueness and / or conflicts, which are not represented naturally within the probabilistic frame work. Emphasis is placed on understanding the types of uncertainties in power system problem that are well represented by fuzzy methods. There are many uncertainties in various power system problems because power systems are large, complex, geographically widely distributed system and influenced by unexpected events [1]. These facts make it difficult to effectively deal with many power 1

systems problems through strict mathematical formulations alone [2]. Therefore the fuzzy logic approach is chosen as one of its area of artificial intelligence approach for the reactive power control for the State Electricity System (SES) which is the utility system. 2. The Need for Reactive Power Control in Power System The ideal ac power should have constant voltage and frequency, should be free from harmonics and the power factor should be nearly unity. The voltage profile of an elective power system could be constantly affected either by the variations of load or by the change of network configurations. The power systems are equipped with a number of voltage controlling devices such as capacitors, tap settings in transformers, UPFC and compensators [3]. The control of reactive power will maintain the level of voltage nearly constant or within the specified tolerance limits. The voltage control should be carried out on line against a possible disturbance, particularly in a heavily loaded system. The objectives are to minimize real power losses and to improve the voltage profile of the given system. The purpose of reactive power / voltage control in a distribution substation is to control the reactive power flow over the main transformer and the voltage on the low voltage bus. It is evident that sufficient reactive power reserve is required to maintain terminal voltage at the load bus. The objectives of reactive power control in power system are to minimize the real power which will reduce the operative cost and improve the voltage profile [4]. In addition to the voltage control the other effects of providing reactive power compensating devices at the load bus are: Reduction in supply side reactive burden Reduction of system copper loss due to reduction of reactive current Decrease in KVA loading of alternators Reduction in investment per kw of load supplied Improvement in the system power factor UPFC Design 3. Reactive Power Control One of the important operative tasks of power utilities is to keep voltage within an allowable range for high quality customer services. Electric power load varies from hour to hour and voltage can be varied by change of the power load. To maintain constant voltage profile, the reactive power control is needed. If the voltage of the bus is more than the specified level then the reactive power from that particular bus is to be absorbed. On the other hand if the voltage level is lower than the required level then the reactive power has to be injected to that bus. This is known as the reactive power control, which is needed to maintain the voltage profile by minimizing bus voltage variations. Power utility operators in control centers handle various equipment such as generators, transformers, static condenser, shunt reactor UPFC, so that they can inject reactive power and control voltage directly in target power system in order to follow the load change. The purpose of reactive power/voltage control in a distribution substation is to control the reactive power flow over the main transformer and the voltage on the low voltage bus. The ON / OFF status of the capacitor and tap positions for the LTC at each hour in the next day can be determined in order to keep the reactive power flow over the main transformer as small as possible and to maintain secondary bus voltage as close to the specified value a possible at all hours in the day [3]-[5]. 4. Fuzzy Logic Implementation Fuzzy logic allows a convenient way to incorporate the knowledge of human experts into the expert system using qualitative and natural language like expressions. The empirical establishment of the membership functions and the rule base allow one to incorporate available human knowledge and heuristics. The approach of this paper is to develop tools specifically designed for real-time operation instead of adapting planning tools for this purpose. In this case, the objective is to integrate Artificial Intelligence with traditional techniques for a more realistic formulation of the problem while maintaining a high computation efficiency [6]-[8]. The fuzzy set theory provides an excellent framework for this type of integration. The objective is to have optimal control of reactive power and to minimize real power losses and to improve the voltage profile of a system. Voltage constraints are also represented as fuzzy sets to reflect a more practical behaviour in this optimization problem. In this paper the optimal reactive power control problem will become that of maximizing this intersection, uncertainties in load and generations are modeled as fuzzy members. The approach by using the fuzzy sets aims at the enhancement of voltage security. In this modeling, two linguistic variables are applied to 2

measure the proximity of a given quantity to a certain condition to be satisfied [9]. The two linguistic variables are used as two inputs; they are Load in MW (Input 1) and the voltage level in KV (Input 2). The output is the reactive power requirement in MVAR. For load (input 1) the intervals are divided into five triangular membership functions as: * Very Low (V.LOW) * Low (LOW) * Medium (MEDIUM) * High (HIGH) * Very high (V.HIGH) The triangular membership function in shown below in fig.1. Fig. 1. Triangular Membership function for load. The intervals for voltage level (Input 2) are divided into three triangular membership functions as: *Low(LOW) *Medium(MEDIUM) *High(HIGH) The Triangular Membership function is shown below in fig.2 Fig. 2. Triangular Membership function for voltage The intervals for the Reactive Power (output) are divided into five triangular membership functions as: * Very Low (V.LOW) * Low (LOW) * Medium (MEDIUM) * High (HIGH) * Very high (V.HIGH) The triangular Membership function is shown below in Figure3. Fig. 3. Triangular Membership function for reactive power. The proposed approach is simple and straight forward which defines the membership function of the two linguistic variables ingeniously, so that the merits of fuzzy techniques are brought into play. In this modeling, control heuristics are expressed by IF THEN Fuzzy rules, where the premises are given by the inguistic variables, measuring the proximity of a given input to a certain condition to be satisfied as the grade of membership in fuzzy sets. Every premise include in a rule has a numerical value rather than true or false, which enables in relaxed pattern matching and flexible application of known numerical model in the consequence, reflecting the relation between input and output [6], [8]. The flowchart for the voltage-reactive power control based on fuzzy modeling is shown in Fig. 4. 5. Case Study Case study has been carried out for State Electricity System (SES) in India which is considered as the utility system in this paper. The different types of generation system have been considered. Here station A consists of Thermal stations, station B consists of Hydro-Irrigation Stations and Station C means hydro non-irrigation and Station D means the Diesel generation stations. The various values of load MW, Reactive power in MVAR and the voltage levels in KV are shown below in Table 1 for all the four stations (Stations A,B,C,D). The case study is carried out for a particular day. Simulations of results are carried out in MATLAB simulation package. The fuzzy membership functions for the inputs and output, three-dimensional surface views for these four stations are shown in Fig. 5, 6, 7 and 8(a) & (b) respectively. 3

Table 1. State Electricity System (SES) Real (Re) Power in MW, Reactive Power, Conventional (Con) and Fuzzy (Fuz) in MVAR, Voltage in KV for a particular day. Voltage in KV Station A Station B Station C Station D Time B, D C A (Hrs) Re Con Fuz Re Con Fuz Re Con Fuz Re Con Fuz 110 230 400 MW MVAR MVAR MW MVAR MVAR MW MVAR MVAR MW MVAR MVAR 1 635 55 49.6 15 12 9.96 30 12 10.9 2 44 42 111 231 426 2 640 65 58.6 15 12 9.96 30 12 10.9 2 50 42 111 231 424 3 610 50 38.0 15 12 9.96 30 12 10.8 2 48 42 111 230 425 4 640 65 58.6 15 12 10.5 30 12 10.8 2 50 42 110 230 424 5 640 80 62.5 46 22 16.3 30 12 10.8 2 48 42 110 230 423 6 640 80 62.2 90 44 40.5 105 40 37.4 2 48 42 110 230 420 7 645 90 79.7 90 44 41.0 105 40 37.4 2 56 42 109 227 418 8 645 125 81.8 90 44 40.5 105 40 37.1 2 52 42 110 227 416 9 645 110 81.5 90 44 41.0 105 40 37.4 2 48 42 109 229 417 10 645 90 79.7 90 44 41.0 105 40 37.4 2 44 42 109 230 418 11 645 90 81.8 90 44 41.0 105 40 37.1 2 56 42 109 230 416 12 645 50 38.0 90 44 41.0 105 40 37.1 2 52 42 109 232 420 13 640 85 76.9 85 44 40.5 105 40 37.1 2 48 42 110 231 418 14 640 85 76.2 85 44 40.9 105 40 37.1 2 46 42 111 232 417 15 640 80 62.2 85 44 40.9 105 40 37.1 2 52 42 112 231 420 16 640 85 76.9 85 44 40.9 105 40 37.1 2 52 42 111 231 418 17 640 90 71.0 85 44 40.5 105 40 37.1 2 42 42 110 229 419 18 640 90 71.0 85 44 40.5 105 40 37.4 2 43 42 110 230 419 19 640 120 76.2 85 44 40.5 105 40 37.4 2 44 42 110 230 417 20 640 85 76.9 85 44 40.5 105 40 37.4 2 44 42 110 230 418 21 640 80 62.2 85 44 40.5 105 40 37.4 2 48 42 110 233 421 22 640 80 62.5 15 12 9.96 105 40 37.1 2 50 42 111 231 423 23 640 70 62.5 15 12 9.96 15 12 10.9 2 46 42 111 232 423 24 640 70 62.2 15 12 9.96 15 12 10.9 2 45 42 111 232 421 Re- Real Power; Con Conventional Controller; Fuz Fuzzy Controller Reactive Power for SES (State Electricity System) Station A Fig. 5(a) Inputs and Output Fig.5 (b): Three Dimensional Surface views 4

START Reactive Power for SES (State Electricity System) Station B INPUT SYSTEM DATA INPUT BUS VOLTAGE DATA Figure 6(a) Inputs and Output CALCULATE LOAD FLOW No BUS VOLTAGES VIOLATE No CONSTRAINTS Yes DETERMINE VOLTAGE CONTROL BY APPROXIMATE REASONING Fig.6 (b): Three Dimensional Surface views Reactive Power for SES (State Electricity System) Station C ESTIMATE CONTROL EFFECT WILL VOLTAGE BE RESTORED TO NORMAL? Yes SUBMIT CONTROL COMMAND No Figure 7(a) Inputs and Output END Fig. 4. Flow Chart for voltage fuzzy based voltage-reactive power control Figure 7 (b): Three Dimensional Surface views 5

Reactive Power for SES (State Electricity System) Station D Figure 8(a) Inputs and Output Figure 8 (b): Three Dimensional Surface views 6. Result Analysis The fuzzy rule approach is designed to closely describe the input, output relationship of the actual problem by using linguistic terms. Fuzzy logic membership functions and fuzzy rules are designed to provide a simple technique to directly implement experience and intuition into a computer program. This approach is much closer to people s decision making process in real life that we consider the preference around the environments before making final decision. From Table 1 it is observed that the voltage is maintained within tolerable limit of + 5 %. It is noticed that the voltage is almost constant. The variations and fluctuations in the voltage level are negligible. The comparison of results by conventional control method and fuzzy control method is done for the State Electricity System (SES). The values are shown in Table I and the compared results are shown in Figures 9 (a), (b), (c) and (d) for stations A, B, C & D respectively. From Figure 9 (a), (b), (c) and (d), it is observed that the reactive power requirement values by the fuzzy approach is lower than the conventional methods which is more economical and requires less number of capacitor or reactive power compensating devices. Hence the fuzzy approach is best suited for reactive power control / UPFC. Comparison of Conventional and Fuzzy Controller for Station-A Reactive Power in MVAR 140 120 100 80 60 40 20 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time in Hours Fig. 9 (a) Comparison of Conventional and Fuzzy Controller for Station-A Dynamic Fuzzy 6

Coparision of Conventional and Fuzzy Controller for Station-B Reactive Power in MVAR 50 45 40 35 30 25 20 15 10 5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time in Hours Fig. 9 (b) Comparison of Conventional and Fuzzy Controller for Station-B Comparison of Conventional and Fuzzy Controller for Staction-C Reactive Power in MVAR 45 40 35 30 25 20 15 10 5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time in Hours Fig. 9 (c) Comparison of Conventional and Fuzzy Controller for Station-C Comparison of Conventional and Fuzzy Controller for Station-D Reactive Power in MVAR 60 50 40 30 20 10 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time in Hours Fig. 9 (d) Comparison of Conventional and Fuzzy Controller for Station-D 7

7. Conclusion Fuzzy logic allows a convenient way to incorporate the knowledge of human experts using qualitative and natural language like expressions. In this reactive power control two inputs such as load and the level of voltages are considered as fuzzy inputs. The reactive power requirements are formed out as output. By changing the value of reactive power the voltage profile is maintained constant. Voltage is the sole indicator of reactive power balance. By controlling the reactive power the real power losses are reduced. In SES for the different stations (A, B, C and D) the requirements of reactive power required have been found out by fuzzy approach. All these reactive power values are compared with the conventional controller. It is found out that the reactive power requirements calculated by the fuzzy approach are lower than the conventional controller. Hence, this fuzzy logic approach for reactive power control is a flexible approach to a coordinated control of voltage and reactive power in order to enhance voltage security of electric power systems. It is concluded that the fuzzy logic controller is better, effective, superior and much closer to people s decision-making process in real life. 5. Mekhamer, S.F., Application of Fuzzy logic for reactive power compensation of Radial Distribution Feeres, IEEE Trans. on Power Systems, Vol.18, No.1, (2003), pp. 206-213. 6. Ross, T. J., Fuzzy logic with Engineering Application, (1995). McGraw Hill. Inc., New York. 7. George. J. Klir, Bo Yuan, Fuzzy Sets and fuzzy Logic, (2000),.Prentice hall of India Private Limited, New Delhi. 8. Stamatios V. Kartalopoulos, Understanding Neural Networks and Fuzzy Logic, IEEE Press, (2000), Prentice Hall of India Private Limited, New Delhi. 9. Chenthur Pandian, S., Duraiswamy, K., and Ravichandran, S., Fuzzy logic approach for reactive power contro,, Int. Conference at KCT, Coimbatore, India, in Collaboration with National University, Singapore and Oakland University, USA, 2005. References: 1. Bansal, R.C., Bibliography on the fuzzy set theory applications in power systems, 1994-2001, IEEE Transactions on power systems, vol 18, No.4, (2003), pp.1291-1299, 2. Chenthur Pandian, S., Duraiswamy, K., Christober Asir Rajan, C., Kanagaraj, N., Fuzzy approach for short term load forecasting, Electric Power Systems Research, Elsevier, 76, (2006), pp 541-548. 3. Yoshida, H., Kawata, K., Fukyyama, Y., Takayama, S. and Nakamishi, Y., A Particle Swarm optimization for reactive power and voltage control considering voltage security assessment, IEEE Trans. on Power Systems, Vol.15, No.4, (2000), pp.1232-1239. 4. Deng, Y., Ren, X., Zhao, C. and Zhao, D., A Heuristic and Algorithm Combined Approach for reactive power optimization with time varying load demand in distribution systems, IEEE Trans on Power Systems, Vol.17, No.4, (2002), pp.1068-1072. 8