LTQ Orbitrap XL Hybrid FT Mass Spectrometer Unrivaled Performance and Flexibility

Similar documents
Thermo Scientific icap 6000 Series ICP Emission Spectrometer

Thermo Scientific Solutions for Intact-Protein Analysis. Better, Faster Decisions for. Biotherapeutic Development

Thermo Scientific DFS High Resolution GC/MS Designed for Highest Sensitivity

Monoclonal Antibody Characterization on Q Exactive and Oribtrap Elite. Yi Zhang, Ph.D Senior Proteomic Marketing Specialist Oct.

A Complete Workflow Solution for Intact Monoclonal Antibody Characterization Using a New High-Performance Benchtop Quadrupole- Orbitrap LC-MS/MS

Chrom-Card Data System. A simple, chemist-oriented data handling system...productive from the first day!

LC/MS/MS Solutions for Biomarker Discovery QSTAR. Elite Hybrid LC/MS/MS System. More performance, more reliability, more answers

Key Words Q Exactive Focus, SIEVE Software, Biomarker, Discovery, Metabolomics

Rapid Peptide Mapping via Automated Integration of On-line Digestion, Separation and Mass Spectrometry for the Analysis of Therapeutic Proteins

AB SCIEX TripleTOF 5600 SYSTEM. High-resolution quant and qual

Thermo Scientific EASY-nLC 1200 System. Leading in simplicity. and performance

Využití cílené proteomiky pro kontrolu falšování potravin: identifikace peptidových markerů v mase pomocí LC- Q Exactive MS/MS

Lebedev A, 1 Damoc E, 2 Makarov A, 2 Samguina T 1 1. Moscow State University, Moscow, Russia; 2 ThermoFisher Scientific, Bremen, Germany

High Resolution Accurate Mass Peptide Quantitation on Thermo Scientific Q Exactive Mass Spectrometers. The world leader in serving science

Thermo Scientific Transcend System

Analysis of Glyphosate and AMPA in Environmental Water Samples by Ion Chromatography and On-Line Mass Spectrometry with Minimal Sample Preparation

Proteomics: A Challenge for Technology and Information Science. What is proteomics?

rapiflex Innovation with Integrity Designed for Molecules that Matter. MALDI TOF/TOF

Thermo Scientific Peptide Mapping Workflows. Upgrade Your Maps. Fast, confident and more reliable peptide mapping.

Thermo Scientific Proteomics & Metabolomics Seminar Tour

Featuring Analyst software under Windows NT for enhanced performance and ease of use. API 150EX. LC/MS System

Highly Confident Peptide Mapping of Protein Digests Using Agilent LC/Q TOFs

TechnicalNOTE METABOLYNX EXACT MASS DEFECT FILTER: RAPIDLY DISCRIMINATE BETWEEN TRUE METABOLITES AND FALSE POSITIVES INTRODUCTION

Thermo Scientific TSQ Quantum Access MAX

Total Chlorine Analyzer ECS 1200/ ECS Many Applications, One Solution

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

Detecting Challenging Post Translational Modifications (PTMs) using CESI-MS

Xevo G2-S QTof and TransOmics: A Multi-Omics System for the Differential LC/MS Analysis of Proteins, Metabolites, and Lipids

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment QTRAP 5500

TurboMass GC/MS Software

Proteomics. Proteomics is the study of all proteins within organism. Challenges

Tony Mire-Sluis Vice President, Corporate, Product and Device Quality Amgen Inc

Center for Mass Spectrometry and Proteomics Phone (612) (612)

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

Thermo Scientific FLASH 2000 Series Organic Elemental Analyzers

Thermo Scientific DSQ. II Series Single Quadrupole GC/MS. Redefining Productivity in the Workplace

Rapid Peptide Catabolite ID using the SCIEX Routine Biotransform Solution

Structure Characterization and Differentiation of Biosimilar and Reference Products Using Unique Combination of Complementary Fragmentation Mechanisms

SNP GENOTYPING WITH iplex REAGENTS AND THE MASSARRAY SYSTEM

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

The clearly better choice

EDS Phase Mapping of a Contact Metamorphosed Calc-Silicate Rock

The LC-MS/MS Workhorse. SCIEX 4500 Series Mass Spectrometers

Rapid Soft Spot Analysis using the SCIEX Routine Biotransform Solution

Thermo Scientific Mass Spectrometric Immunoassay (MSIA) Pipette Tips. Next generation immunoaffinity. Robust quantitative platform

Quantification of Drug Metabolites in Early-Stage Drug Discovery Testing

Proteomics software at MSI. Pratik Jagtap Minnesota Supercomputing institute

Protein De novo Sequencing

How to view Results with Scaffold. Proteomics Shared Resource

Thermo Scientific Qtegra Intelligent Scientific Data Solution. Delivering quality. Driving productivity

Thermo Scientific Evolution Array UV-Visible Spectrophotometer

Thermo Scientific Evolution Array UV-Visible Spectrophotometer

ENHANCED MS WITH THE TURN OF A KEY

MasterView Software. Turn data into answers reliable data processing made easy ONE TOUCH PRODUCTIVITY

Enabling Systems Biology Driven Proteome Wide Quantitation of Mycobacterium Tuberculosis

Analysis of Trace Elements in Seawater Using the Thermo Scientific icap 7000 Series ICP-OES Duo

QUANLYNX APPLICATION MANAGER

FPO. BioPharma Compass 2.0. Innovation with Integrity. Accelerate Biopharmaceutical Analysis. Software

Two-Dimensional LC Protein Separation on Monolithic Columns in a Fully Automated Workflow

DSQ II GC/MS Series. Redefining Productivity in the Workplace. Sensitivity and large dynamic range for demanding environmental analyses

Towards unbiased biomarker discovery

Simultaneous in vivo Quantification and Metabolite Identification of Plasma Samples Using High Resolution QTof and Routine MS E Data Analysis

Concentration of Human Hormones in Drinking Water Using Solid Phase Extraction and Analysis by High Performance Liquid Chromatography

Utilizing novel technology for the analysis of therapeutic antibodies and host cell protein contamination

Simple, fast and reliable analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS

The Importance of High Speed Data Acquisition in the Design and Implementation of GC/MS Applications

Analysis of Targeted and Non-Targeted Identified Contaminants in Storm Water Retention Ponds Using LC-HRMS With Online Solid Phase Extraction

Proteomics And Cancer Biomarker Discovery. Dr. Zahid Khan Institute of chemical Sciences (ICS) University of Peshawar. Overview. Cancer.

Metabolic Changes in Lung Tissue of Tuberculosis-Infected Mice Using GC/Q-TOF with Low Energy EI

ProteoMiner Protein Enrichment Technology

Application Note. Kwasi Antwi, Amanda Ribar, Urban A. Kiernan, and Eric E. Niederkofler Thermo Fisher Scientific, Tempe, Arizona

N-Glycan Profiling Analysis of a Monoclonal Antibody Using UHPLC/FLD/Q-TOF

Additional file 2. Figure 1: Receiver operating characteristic (ROC) curve using the top

About OMICS Group Conferences

Algorithm for Matching Additional Spectra

Modification Site Localization Scoring Integrated into a Search Engine

Proteins. Patrick Boyce Biopharmaceutical Marketing Manager Waters Corporation 1

Innovations To Meet Your Needs

Accurate and Automated cell confluence assessment in microplates

Metabolomics: Sifting Through Complex Samples

ARL X TRA Powder X-ray Diffraction System. Uncompromised Intensity and Resolution

Thermo Scientific SkanIt software for microplate readers. Simplified data acquisition and analysis

Expression Array System

N- The rank of the specified protein relative to all other proteins in the list of detected proteins.

CaptiveSpray nanobooster

Proteomics Technology Note

ANALYTICAL STANDARDS AND REAGENTS

Chromatography Column Performance and Data Analysis Success Guide. Hints and Tips for Better Purifications

Top-Down, Bottom-Up. The Merging of Two High-Performance Technologies

Bio-Rad Laboratories BIOPLEX 2200 SYSTEM. BioPlex 2200 ANA Screen with MDSS. The first and only fully-automated, multiplexed ANA Screen

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

Generating Automated and Efficient LC/MS Peptide Mapping Results with the Biopharmaceutical Platform Solution with UNIFI

Sprint analysis of lubricating oils using the Thermo Scientific icap 7600 ICP-OES

Identification of Microprotein-Protein Interactions via APEX Tagging

The Five Key Elements of a Successful Metabolomics Study

Genotoxicity is the property of a compound

Advanced QA/QC characterization MS in QC : Multi Attribute Method

Investigating Biological Variation of Liver Enzymes in Human Hepatocytes

EU Water Analysis Using the Thermo Scientific icap 7400 ICP-OES Duo

Transcription:

m a s s s p e c t r o m e t r y LTQ Orbitrap XL Hybrid FT Mass Spectrometer Unrivaled Performance and Flexibility Part of Thermo Fisher Scientific

LTQ Orbitrap XL OFFERING OUTSTANDING MASS ACCURACY, RESOLVING POWER, DYNAMIC RANGE, AND HIGH SENSITIVITY Based on the fast and highly sensitive Thermo Scientific LTQ XL linear ion trap and the patented Orbitrap technology, the LTQ Orbitrap XL hybrid FTMS (Fourier Transform Mass Spectrometer) supports a wide range of applications from routine compound identification to the most challenging analysis of low level components in complex mixtures. LTQ ORBITRAP XL UNRIVALED PERFORMANCE AND FLEXIBILITY Features the new HCD (Higher Energy Collisional Dissociation) collision cell for ultimate flexibility in fragmentation experiments for advanced proteomics and small molecule research Future upgrades will include ETD (Electron Transfer Dissociation) and MALDI capabilities The LTQ Orbitrap received the R&D 100 Award in 2006 and the PITTCON Editor s Gold Award at PITTCON 2006. PRINCIPLE OF OPERATION The hybrid FT mass spectrometer combines a linear ion trap MS and the Orbitrap mass analyzer. Ions generated by API are collected in the LTQ XL followed by axial ejection to the C-shaped storage trap which is used to store and collisionally cool ions before injection into the orbital trap. The ions transferred from the C-Trap are captured in the orbital trap by rapidly increasing the electric field and the detection of the image current from coherent ion packets takes place after the voltages have stabilized. Signals from each of the orbital trap outer electrodes are amplified and transformed into a frequency spectrum by fast Fourier transformation which is finally converted into a mass spectrum. Additionally, the LTQ Orbitrap XL features a new collision cell to provide additional flexibility to any MS/MS experiment. Ions can be selected in the linear ion trap and fragmented either in the ion trap (CID) or in the new collision cell (HCD). For HCD (Higher Energy Collisional Dissociation) ions are passed through the C-trap into the gas-filled collision cell. Normalized Collision Energy in HCD MS/MS experiments provides reproducible data from instrument to instrument. API Ion Source LTQ XL Linear Ion Trap C-Trap HCD Collision Cell Schematic of the LTQ Orbitrap XL. Orbitrap Mass Analyzer

THE MOST CONFIDENT PROTEIN IDENTIFICATION The analysis of complex protein mixtures is one of the most challenging tasks in the area of proteomics. The key requirements of mass spectrometry based methods are a wide dynamic range, outstanding mass accuracy, fast cycle times for MS/MS experiments, and high sensitivity. The LTQ Orbitrap XL meets all of these requirements and provides the most confident protein identification. Base peak chromatogram of E. coli total enzymatic digest. THE LTQ ORBITRAP XL PROVIDES: Superior mass accuracy for lower false positive rates High sensitivity and dynamic range leading to more protein ID Parallel acquisition mode for optimized productivity Excellent MS/MS sensitivity Comparison of the protein identification results (MASCOT) between the LTQ Orbitrap XL and latest Q-TOF technology. Experimental Method E. coli total digest (500 ng) Online nano LC-MS and MS/MS Optimized productivity with parallel detection Orbitrap mass analyzer full scan with Ion Trap Top 7 Data Dependent MS/MS Dynamic exclusion BioWorks result of the database search showing the confident peptide identification. Orbitrap mass analyzer full scan MS at RT 89.4 min with zoom-in.

LTQ Orbitrap XL FROM PROTEIN ID TO BIOMARKER DISCOVERY An important aspect of proteomics is not only the identification of all proteins in complex biological samples but also the accurate determination of their relative concentrations. Several analytical approaches to protein quantitation have been developed, including isotopic labeling techniques such as itraq. This method relies on the measurement of specific reporter ions in the low m/z region of MS/MS spectra of target peptides. The new HCD collision cell of the LTQ Orbitrap XL is ideally suited to perform such experiments with excellent sensitivity and signal-to-noise ratio (S/N) for the reporter ions and the fragment ions of the peptide sequence. THE LTQ ORBITRAP XL WITH NEW HCD COLLISION CELL PROVIDES: Excellent sensitivity and fragmentation efficiency Reliable identification and quantitation in one experiment More confidence in biomarker research Base peak chromatogram of nano LC-MS and MS/MS analysis.* itraq reporter ions. Experimental Method Mouse cell line itraq labeled Online nano LC-MS and MS/MS Orbitrap mass analyzer full scan at R = 30,000 Data Dependent Top 3 MS/MS using HCD Dynamic exclusion HCD spectrum for FSALESQLQDTQELLQEENR (MYH9_MOUSE, Myosin-9) in mouse cell line digest derivatized with four itraq reagents.* * The isotopically labeled (itraq) protein digest sample was provided by Jarrod Marto, Ph.D. and Yi Zhang, Ph.D., BLAIS Proteomics Center Boston, MA USA

HIGH QUALITY DATA FOR RELIABLE DE NOVO SEQUENCING While the extensive use of large-scale genomic sequencing has greatly simplified the task of identifying peptides and proteins by mass spectrometry, the use of de novo sequencing is still required in proteomics research. BASED ON ULTIMATE PERFORMANCE THE LTQ ORBITRAP XL PROVIDES: Superior mass accuracy and high resolution leading to confident de novo sequencing results Multiple collision modes (CID and HCD) for comprehensive structural information Spectrum of precursor ion with excellent mass accuracy. Zoom-in on low mass range showing detected immonium ions. Experimental Method Enzymatic enolase digest Online nano LC-MS and MS/MS Orbitrap mass analyzer full scan at R = 60,000 Data Dependent Top 3 MS/MS using HCD Dynamic exclusion Zoom-In on low mass range showing detected immonium ions. PEAKS view MS/MS of 1086.5445 (YGASAGNVGDEGGVAPNIQTAEEALDLIVDAIK).

LTQ Orbitrap XL CONFIDENT METABOLITE PROFILING AND IDENTIFICATION The characterization of metabolites plays an important role in drug development. Studies performed in vivo and in vitro lead to very complex mixtures containing the biological matrix background, the parent drug and all of the metabolites over a wide concentration range. Based on the selectivity, sensitivity, and speed of analysis, liquid chromatography tandem mass spectrometry has become the method of choice for metabolite profiling and identification. BASED ON ULTIMATE PERFORMANCE THE LTQ ORBITRAP XL PROVIDES: Automated workflows using MetWorks and Mass Frontier for structural elucidation Reliable metabolite profiling and identification based on accurate mass Improved confidence by MS n spectral tree fingerprints to distinguish even isobaric compounds Automated identification of expected metabolites based on accurate mass using MetWorks. Experimental Method Clozapine in vitro incubation Online LC-MS and MS n using CID and HCD Orbitrap mass analyzer full scan Isotopic pattern triggered MS/MS Dynamic exclusion Structural elucidation based on the unique MS n capability of the LTQ Orbitrap XL. Proposed fragmentation pathway of m/z 270 according to Mass Frontier.

CONFIDENT CHARACTERIZATION OF METABOLOMIC PROFILES The goals of metabolomics studies are to compare the abundance of the small molecule metabolites in highly complex matrices such as body fluids and tissues. The greatest challenges are the detection of low abundance metabolites amidst a vast background of unchanged metabolites and to confidently identify their structure. THE LTQ ORBITRAP XL WITH NEW HCD COLLISION CELL PROVIDES: Outstanding mass accuracy, sensitivity, and dynamic range for metabolic profiling Confident determination of the identity and structure of metabolites Determination of differentially expressed metabolites using SIEVE in conjunction with Mass Frontier 2-Dimensional scatter plot showing over- and under-expression generated by Spotfire. Experimental Design In vivo drug treatment of rats Controls: untreated day one rat urine Samples: drug treated day one rat urine Orbitrap mass analyzer full scan SIEVE and Spotfire used to display metabolites that demonstrate statistically significant differences Zoom into SIEVE frame Detailed information of over-expressed metabolites.

THERMO SCIENTIFIC APPLICATION-SPECIFIC SOFTWARE TURNING DATA INTO INFORMATION In addition to these offices, Thermo Fisher Scientific maintains a network of representative organizations throughout the world. Xcalibur data system Stable operating platform Xcalibur is the versatile, easy-to-use data system that controls all Thermo Scientific MS systems. Xcalibur s Home Page offers easy navigation through the process of instrument setup, sequence setup, and data acquisition. The XReport reporting package simplifies custom reporting with drag-and-drop functionality. ProteinCalculator ProteinCalculator performs in silico digestion. Specify peptide sequences or import them from a fasta database, select post-translational modifications from a list or edit novel PTMs, then digest them with an enzyme of your choosing. The proteolytic fragment spectra can be saved as RAW data files for comparison with acquired spectra. Xtract Xtract deconvolutes isotopically resolved data, simplifying complex MS/MS spectra acquired in topdown, intact protein analysis. Specify the mass range, mass resolution, and S/N criteria for deconvolution and display in one of four modes: monoisotopic masses, isotopic pattern, or approved or disapproved signals. The results can be exported as RAW or ASCII file formats. BioWorks protein identification software Confident protein ID featuring the SEQUEST algorithm BioWorks utilizes the SEQUEST search algorithm to automatically identify proteins by comparing experimental tandem mass spectrometry (MS/MS) data with spectra created from standard protein and DNA databases. MetWorks drug metabolism software Simplify the interpretation of complex metabolism data MetWorks simultaneously searches multiple modifications of one or more parent drugs and interprets simple to complex isotope patterns, or unexpected or low abundance metabolites. Mass Frontier spectral elucidation software Turning mass spectral data into results Mass Frontier contains a state-ofthe-art database and predictive fragmentation module which allows you to easily interrogate and assign the structure of your compounds. SIEVE differential expression software Analysis of differential expression based on comparison of LC-MS n datasets SIEVE software provides label-free, semi-quantitative differential expression analysis of proteins, peptides, or metabolites from the comparison of multiple LC-MS data sets. It is a statistically rigorous tool for analyzing data from metabolism or biomarker discovery experiments. Australia +61 2 8844 9500 analyze.au@thermo.com Austria +43 1 333 50340 analyze.at@thermo.com Belgium +32 2 482 30 30 analyze.be@thermo.com Canada +1 800 532 4752 analyze.ca@thermo.com China +86 10 5850 3588 analyze.cn@thermo.com Denmark +45 70 23 62 60 analyze.dk@thermo.com France +33 1 60 92 48 00 analyze.fr@thermo.com Germany +49 6103 408 1014 analyze.de@thermo.com India +91 22 6742 9434 analyze.in@thermo.com Italy +39 02 950 591 analyze.it@thermo.com Japan +81 45 453 9100 analyze.jp@thermo.com Latin America +1 608 276 5659 analyze.la@thermo.com Netherlands +31 76 587 98 88 analyze.nl@thermo.com South Africa +27 11 570 1840 analyze.sa@thermo.com Spain +34 91 657 4930 analyze.es@thermo.com Sweden / Norway / Finland +46 8 556 468 00 analyze.se@thermo.com Switzerland +41 61 48784 00 analyze.ch@thermo.com UK +44 1442 233555 analyze.uk@thermo.com USA +1 800 532 4752 analyze.us@thermo.com www.thermo.com Installation Requirements Power 230 Vac ±10% 3 phase, 16 Amps, 50/60 Hz, with earth ground for the instrument Environment System averages 2800 W (10,000 Btu/hr) output when considering air conditioning needs Weight ~600 kg Dimensions 141.4 87 146.3 cm (H W D) 120 or 230 Vac single phase with earth ground for the data system 120 or 230 Vac single phase, 15 Amps, with earth ground for the water chiller Gas One high purity (99.5% pure, flow rate 15 L/min) nitrogen gas supply for the API source Operating environment must be 15-26 C (59-78 F) and relative humidity must be 40-70% with no condensation Optimum operating temperature is 18-21 C (65-70 F) Thermo Electron (Bremen) GmbH is certified DIN EN ISO 2001:9000 Thermo Fisher Scientific, San Jose, CA USA is ISO Certified. 2007 Thermo Fisher Scientific Inc. All rights reserved. itraq is a trademark of Applera Corporation. Mass Frontier is a trademark of HighChem, Ltd. PEAKS is a trademark of Bioinformatics Solutions, Inc. Spotfire is a registered trademark of Spotfire, Inc. SEQUEST is a registered trademark of the University of Washington. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. One ultra high-purity helium gas supply (99.998%) with less than 1 ppm each of water, oxygen, and total hydrocarbons for the linear ion trap BR30135_E 06/07M