Application Note. Abstract. Authors. Introduction. Environmental

Similar documents
EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

Automated Online SPE for LC/MS/MS Analysis of Trace Organic Contaminants in Water Using the Agilent 1290 Infinity Flexible Cube Module

Application Note. Author. Abstract. Environmental. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions

Peptide Mapping of Glycoprotein Erythropoietin by HILIC LC/MS and RP-LC/MS

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides

Improved SPE for UPLC/MS Determination of Diquat and Paraquat in Environmental

Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run

Characterize Fab and Fc Fragments by Cation-Exchange Chromatography

Development of a Fast and Cost-Effective Multi-Residue Method to Determine Pesticides in Tobacco by LC/MS/MS

Determination of Iodinated Contrast Media in Aqueous Samples by Direct-Injection LC-MS/MS

Cell Clone Selection Using the Agilent Bio-Monolith Protein A Column and LC/MS

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

CHROMATOGRAPHY/MASS SPECTROMETRY

Converting a Liquid-Liquid Extraction Method for Vitamin D to a 96-Well Plate Supported Liquid Extraction Format

Changing the Game in LC-MS/MS. New Tools for Unprecedented Performance in Residue Analysis. Dr. Thomas Glauner

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

N-Glycan Profiling Analysis of a Monoclonal Antibody Using UHPLC/FLD/Q-TOF

Method Translation in Liquid Chromatography

Analysis of Intact and C-terminal Digested IgG1 on an Agilent Bio MAb 5 µm Column

Automated Real-Time Determination of Bromate in Drinking Water Using LC-ICP-MS and EPA Method Application

Tyler Trent, Applications Sales Specialist; Teledyne Tekmar Page 1

Expanding EPA 544: Addition of Seven Microcystin Congeners for Analysis of Lake Erie Beach Samples, a Comparative Study with ELISA

mab Titer Analysis with the Agilent Bio-Monolith Protein A Column

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

Determination of Monocrotophos, Diazinon, Malathion, EPN, and Methamidaphos from Aqueous Samples Using Atlantic HLB SPE Disks

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

Analysis of 16 Pesticide Residues in Broccoli Using CarbonX dspe QuEChERS AOAC Kits Using GC/MS

Application Note. Author. Abstract. Biotherapeutics and Biologics. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

Agilent 6400 Series. System. Concepts Guide. The Big Picture. Agilent Technologies

HIGHER IMPACT LC/MS DIAGNOSTICS AGILENT IN VITRO DIAGNOSTIC MEDICAL DEVICES FOR CLINICAL LABORATORIES

Rapid Soft Spot Analysis using the SCIEX Routine Biotransform Solution

Preparative HPLC is still the

Certified Reference Material - Certificate of Analysis

Analysis of USP <467> Residual Solvents using the Agilent 7697A Headspace Sampler with the Agilent 7890B Gas Chromatograph

PAHs in Surface Water by PDA and Fluorescence Detection

New Contaminants Are Always Emerging. High-Throughput Methods for Testing Serum and Drinking Water

Extraction and Analysis of Neonicotinoid Pesticides using QuEChERS Approach

Optimizing the Purification of a Standard Chiral Compound Utilizing a Benchtop, Multi-Purpose, Semi-Preparative to Preparative HPLC System

Genotoxicity is the property of a compound

EASY-Spray Columns. Guidance for column set up and installation Tips to maximize column lifetime

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

Characterization of Glycosylation in the Fc Region of Therapeutic Recombinant Monoclonal Antibody

The clearly better choice

Protocol for Quantitative Determination of Residual Solvents in Cannabis Concentrates Prepared by: Amanda Rigdon, May 23 rd, 2016

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

MS Certified Vials. Pre-cleaned and certified vials for mass spectrometry

Concentration of Human Hormones in Drinking Water Using Solid Phase Extraction and Analysis by High Performance Liquid Chromatography

A Sub-picogram Quantification Method for Desmopressin in Plasma using the SCIEX Triple Quad 6500 System

Validation Report 19

Analysis of Pesticide Residues and Mycotoxins in Cannabis using QuEChERS Extraction, ChloroFiltr dspe Cleanup and LC-MS/MS Detection

Bio-Monolith Protein G Column - More Options for mab Titer Determination

Application Note. Author. Abstract. Small Molecule Pharmaceuticals. Sonja Krieger Agilent Technologies, Inc. Waldbronn, Germany

Choosing the Right Calibration for the Agilent Bio SEC-3 Column

EtG / EtS Analysis UCT INNOVATION THROUGH CHEMISTRY FORENSICS

Peptide Mapping: A Quality by Design (QbD) Approach

Thermo Scientific TSQ Quantum Access MAX

Optimization of Volatile Petroleum Hydrocarbons Analysis by Automated Headspace Using Method Development Tools

Fraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction. chromatography. Agilent 1260 Infinity II Bio-Inert System

Olga Shimelis, Katherine Stenerson, Michael Ye, Carmen T. Santasania, and Ed Mauney. Supelco, Div. of Sigma-Aldrich, Bellefonte, PA USA

ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS

Glyphosate and AMPA in drinking water

Application Note. Authors. Abstract

Protein-Pak Hi Res HIC Column and HIC Protein Standard

Improving Resolution and Column Loading Systematically in Preparative Liquid Chromatography for Isolating a Minor Component from Peppermint Extract

Improved Peptide Maps Using Core-Shell Media: Explaining Better Biopharmaceutical Applications With Kinetex C18 Columns

Using accurate mass LC/MS/MS in forensic toxicology screening

Generating Automated and Efficient LC/MS Peptide Mapping Results with the Biopharmaceutical Platform Solution with UNIFI

Liquid Chromatograph Liquid Chromatograph Mass Spectrometer. CL Series. for In Vitro Diagnostic Use

Automated Solid Phase Extraction of PAH Compounds Utilizing the SPE-DEX 5000

HepG2 Labeling and Cell Growth Protocol for IROA Phenotypic Metabolic Profiling

Practical guidance for switching between anion and cation analysis systems

Low-level Detection of Ethanol, 1,4-Dioxane, and Other Oxygenates Using the Eclipse Purge-and-Trap Sample Concentrator

Quantitation of Microcystins and Nodularins in Water Samples Using LC-MS/MS

MassPREP On-Line Desalting Cartridge

Agilent Ultimate Plus Fused Silica Tubing

Investigation of Solid Phase Microextraction as an Alternative to Dried Blood Spot

The Determination of Trace Elements in Stainless Steel by Forked Platform GFAAS

QUANLYNX APPLICATION MANAGER

Chem-Lab High Purity Solvents

Key Words Q Exactive Focus, SIEVE Software, Biomarker, Discovery, Metabolomics

Agilent MetaCarb Ca PLUS Carbohydrate Column Ca ++ Form User Manual Part No. A5205

A Single Analyzer Solution for Refinery Flare Emissions Monitoring (40 CFR 60 Subpart Ja) Using Mass Spectrometry

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment QTRAP 5500

Measurement of Bromate and Haloacetic Acids In Drinking Water by IC-MS/MS

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

Fluensulfone on Potatoes and Sugar Beets

A Unique LC-MS Assay for Host Cell Proteins(HCPs) ) in Biologics

Determination of Oxalate and Other Anions in Bayer Liquor Using Ion Chromatography

Fast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover

Using the Pulsed Flame Photometric Detector (PFPD) for Low-level Analysis of Organophosphorus Pesticides

Validation Report 16

ENHANCED MS WITH THE TURN OF A KEY

DNA Synthesis With IRDye 700 Phosphoramidite. Part #

Guidelines on Quality Assurance/Quality Control for The Environmental Measurements of Dioxins

ZORBAX StableBond HPLC Columns

Transcription:

EPA Method 538: Determination of Selected Organic Contaminants in Drinking Water by Direct Aqueous Injection with the Agilent 646 Triple Quadrupole LC/MS System Application Note Environmental Authors Imma Ferrer and Michael Thurman Center for Environmental Mass Spectrometry University of Colorado in Boulder, Colorado, USA Abstract A new method from the U.S. EPA (538) on 11 selected organic contaminants in drinking water by direct aqueous injection liquid chromatography/mass spectrometry/ mass spectrometry has been developed using UHPLC and the Agilent Model 646 Triple Quadrupole LC/MS System. One advantage of the EPA method is that solid phase extraction is no longer needed for sample preparation. This means that the analysis time is reduced by at least half. Furthermore, run time was cut by almost two-thirds by the use of UHPLC, and the method provided excellent linearity (R 2.9999) for all analytes, with limits of detection from 1 to 5 ng/l. Introduction Pesticides and other organic contaminants in drinking water pose potential human health risks. Agricultural and industrial uses of these chemicals are major sources of such contamination. To ensure the quality of drinking water in the US, the Environmental Protection Agency (EPA) has a number of monitoring requirements. EPA Method 538 has been developed and implemented for the determination of selected organic contaminants in drinking water, most of which are organophosphate pesticides. EPA Method 538 involves analysis of water by direct aqueous injection and liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS). The method measures the presence of 11 target analytes, using five deuterated internal standards. The analytes are separated and identified by comparing the acquired transition ions and retention times to calibration standards obtained under identical LC/MS/MS conditions. The concentration of each analyte is determined by internal standard calibration following standard procedures. Because the method requires no sample extraction, it is rapid and inexpensive relative to other LC/MS/MS methods.

This application note describes an Agilent implementation of EPA Method 538, which is demonstrated with the Agilent 129 Infinity LC System and an Agilent 646 Triple Quadrupole LC/MS System using Jet Stream technology. The 1-minute UHPLC chromatographic analysis is more than twice as fast as the original EPA Method 538, saving time and solvent costs. The method was modified by adding a second transition for all analyte ions for confirmation, which satisfies the European Union (EU) specifications for unequivocal identification by mass spectrometry. This gives an even greater assurance of correct identification than prescribed by the EPA. The utility of the method was demonstrated using local water samples. Experimental Reagents and Standards All standard solutions (1 µg/ml) were purchased from Accustandards (New Haven, CT). The deuterated standards were obtained from Cambridge Isotopes (Cambridge, MA). HPLC grade acetonitrile and methanol were obtained from Burdick and Jackson (Muskegon, MI, USA). Formic acid was obtained from Sigma-Aldrich (St. Louis, MO, USA). Individual stock solutions (1 µg/ml) were prepared in pure methanol and stored at -18 C. From these solutions, working standard solutions were prepared by dilution with acetonitrile and water. Instruments The method was run on the 129 Infinity LC System with a 1 µl sample loop, coupled to the 646 Triple Quadrupole LC/MS System with Jet Stream Technology. The instrument conditions are listed in Table 1. Table 1. LC and MS Instrument Conditions LC conditions Column Agilent ZORBAX RRHD Eclipse Plus C18, 2.1 x 5 mm, 1.8 µm (p/n 959757-92) Column temperature 25 C Injection volume 1 µl Mobile phase A = Acetonitrile B =.1% acetic acid in water Run time 1 min Flow rate.4 ml/min Gradient 9% B at time, and hold for 1.7 min. Gradient to 1% B at 1 min. MS conditions Sheath gas temperature 35 C Sheath gas flow 11 L/min Gas temperature 25 C Desolvation gas flow rate 1 L/min Nebulizer pressure 45 psi Capillary voltage 4 V Nozzle voltage V Delta EMV 2 V Sample Preparation Method 538 calls for a 4 ml water sample, preserved with sodium omadine and ammonium acetate. Remove a 95 µl aliquot and place it in a vial, along with a 5 µl aliquot of five deuterium labeled internal standards. The organic solvent content of the sample should not exceed 5%. Collect the samples in baked amber glass bottles and store at 4 C until analyzed. Pass the water sample through a PFTE filter (.2 µm) before addition of internal standards, in order to prevent plugging of the analytical column. The sample is then ready for direct injection into the LC/MS/MS system. Blanks should also be passed through the filter to check for interferences. 2

Results and Discussion Method 538 Table 2 shows the 1 organophosphate analytes included in EPA Method 538 along with the polynuclear aromatic heterocycle, quinoline. These 11 analytes represent important possible drinking water contaminants [1]. Five deuterated standards are also part of the method and are shown in Table 3. Table 2. Ten Organophosphate Pesticides and Quinoline are the 11 Compounds Measured in EPA Method 538 as Drinking Water Contaminants Chemical Abstract Services Analyte Registry Number (CASRN) Acephate 356-19-1 Aldicarb 116-6-3 Aldicarb sulfoxide 1646-87-3 Dicrotophos 141-66-2 Diisopropyl methylphosphonate (DIMP) 1445-75-6 Fenamiphos sulfone 31972-44-8 Fenamiphos sulfoxide 31972-43-7 Methamidophos 1265-92-6 Oxydemeton-methyl 31-12-2 Quinoline 91-22-5 Thiofanox 39196-18-4 One advantage of the EPA method is that solid phase extraction (SPE) is no longer needed for sample preparation, which means that total analysis time is cut at least in half. In addition, suppression from the sample matrix is reduced because the matrix is not concentrated as may occur with SPE. Although concentration of the sample may enable lower detection limits, this advantage will be mitigated by suppression effects. In addition, the sensitivity of the instrument negates the need for concentration of the sample. The method is quite simple, requiring only the addition of the internal standard mixture to the water sample. Table 3. The Five Deuterated Internal Standards Used in EPA Method 538 [1] Internal standards Acephate-d 6 Diisopropyl methylphosphonate-d 14 (DIMP-d 14 ) Metamidophos-d 6 Oxydemeton-methyl-d 6 Quinoline-d 7 3

Limits of Detection and Linearity The EPA Method 538 calls for one MRM transition per compound [1]. The adaptation of the method described includes a second transition in order to provide a confirmation ion for each detected compound. This change also conforms to standard analytical procedures that call for a second confirming transition for analysis by LC/MS/MS using triple quadrupole methods, as well as ion-ratio percentages. Table 4 shows the transitions for each of the 11 compounds, along with the fragmentation and collision energies. Table 5 shows the transition used for each of the deuterated labeled standards used for quantitation, as well as their fragmentation and collision energies. Table 5. Transitions, Fragmentation Energies, and Collision Energies for Each of the 5 Labeled Standards for EPA Method 538 Fragmentation Collision Compound Transition energy energy Acephate-d 6 19&149 5 DIMP-d 14 195&99 7 5 Methamidophos-d 6 148&97 7 1 Oxydemeton-methyl-d 6 253&175 7 1 Quinoline-d 7 137&81 11 35 Table 4. Transitions, Fragmentation Energies, and Collision Energies Used for Each of the 11 Standards for EPA Method 538 Collision Compound name Precursor ion Product ion Dwell Fragmentor (V) energy (V) Polarity Acephate 26 165 1 9 5 Positive Acephate 184 143 1 5 Positive Aldicarb 213 116 1 9 5 Positive Aldicarb 213 89 1 9 15 Positive Aldicarb-sulfoxide 229 166 1 7 5 Positive Aldicarb-sulfoxide 229 19 1 7 1 Positive Dicrotophos 238 193 1 7 Positive Dicrotophos 238 112 1 7 5 Positive DIMP 181 139 1 7 Positive DIMP 181 97 1 7 5 Positive Fenamiphos-sulfone 336 38 1 11 1 Positive Fenamiphos-sulfone 336 266 1 11 15 Positive Fenamiphos-sulfoxide 32 292 1 11 1 Positive Fenamiphos-sulfoxide 32 233 1 11 2 Positive Methamidophos 142 125 1 7 1 Positive Methamidophos 142 94 1 7 1 Positive Oxydemeton-methyl 269 191 1 11 5 Positive Oxydemeton-methyl 247 169 1 7 1 Positive Quinoline 13 13 1 11 25 Positive Quinoline 13 77 1 11 35 Positive Thiofanox 241 184 1 9 5 Positive Thiofanox 241 57 1 9 15 Positive 4

The extracted ion chromatogram (EIC) for the 11 compounds of EPA Method 538 is shown in Figure 1, using a 1-minute rapid gradient with UHPLC (Table 1). The 11 compounds elute in approximately 6 minutes. The more polar compounds, such as methamidophos, acephate, and aldicarb sulfoxide, elute in the first minute of the chromatogram. The more hydrophobic compounds, such as diisopropyl methylphosphonate (DIMP), aldicarb, fenamiphos sulfoxide, and sulfone, along with thiofanox, elute at the end of the chromatographic run. Good peak shape, which improves sensitivity and increases the limit of detection, was accomplished with this gradient. The limits of detection (LODs) for the 11 analytes varied from 1 ng/l for aldicarb sulfoxide, which was the most sensitive compound, to 5 ng/l for acephate, which was the least sensitive compound (Table 6). The wide variation in LODs reflects the ability of each analyte to form ions in electrospray. The most polar analytes such as acephate and methamidophos were the least sensitive, while fenamiphos sulfone, and thiofanox were some of the most sensitive compounds and also the most hydrophobic. The LODs for 9 of the 11 compounds were lower than those posted in Table 5 of Method 538, and the MRLs for the same nine compounds were also equal to or lower than those listed in Table 5. Quinoline in particular is much more sensitive using the Agilent 646 Triple Quadrupole LC/MS System with Jet Stream Technology because it is a stable compound (PNA) with a nitrogen heteroatom. Thus, this adaptation of Method 538 meets the criteria for a sensitive method for organophosphate pesticides in drinking water. The extra MRM transition used in this adaptation of Method 538 is an important component of a valid method for water quality analysis of pesticides in water samples. The European Union (EU) specifications for unequivocal identification by mass spectrometry require two transitions, and this procedure has become an unofficial standard worldwide. Table 6. Limits of Detection for EPA Method 538 Fortified conc. LOD MRL Compound (ng/l) a (ng/l) b (ng/l) c Acephate 5 5 1 Aldicarb 5 2 5 Aldicarb sulfoxide 5 1 2 DIMP 1 1 2 Dicrotophos 1 1 2 Fenamiphos sulfone 5 5 1 Fenamiphos sulfoxide 5 5 1 Methamidophos 5 5 1 Oxydemeton-methyl 5 5 1 Quinoline 1 1 2 Thiofanox 5 2 5 a. Spiking concentration used to determine LOD b. Limit of Detection (determined as three times signal-to-noise) c. Method Reporting Limit (determined as six times signal-to-noise with two transitions per compound taken into account) Counts 1 5 3. 2.8 2.6 2.4 2.2 2. 1.8 1.6 1.4 1.2 1..8.6.4.2 Methamidophos Acephate Aldicarb sulfoxide Quinoline Oxydemeton-methyl Dicrotophos DIMP Aldicarb Fenamiphos sulfoxide Fenamiphos sulfone.2.6 1. 1.4 1.8 2.2 2.6 3. 3.4 3.8 4.2 4.6 5. 5.4 5.8 6.2 6.6 7. 7.4 7.8 8.2 8.6 9. 9.4 9.8 1.2 Acquisition time (min) Thiofanox Figure 1. UHPLC extracted ion chromatogram (EIC) with the Agilent 129 Infinity LC System, for the 11 analytes of EPA Method 538. 5

Figure 2 shows the excellent linearity that was achieved with the direct injection method for two of the analytes, quinoline and fenamiphos sulfone. In fact, the R 2 values are.9999 for all compounds in this method. Responses Responses 1 5 7. 6.5 6. 5.5 5. 4.5 4. 3.5 3. 2.5 2. 1.5 1..5 -.5 1 5 2.8 2.6 2.4 2.2 2. 1.8 1.6 1.4 1.2 1..8.6.4.2 -.2 Quinoline - 8 levels, 8 levels used, 8 points, 8 points used, QCs y = 13867.611595x + 884.428417 R 2 =.99995441-4 -2 2 4 6 8 1 12 14 16 18 2 22 24 26 28 3 32 34 36 38 4 42 44 46 48 5 52 54 Concentration (µg/l) Fenamiphos sulfone - 8 levels, 8 levels used, 8 points, 8 points used, QCs y = 5555.56481x + 42.547499 R 2 =.9999771-4 -2 2 4 6 8 1 12 14 16 18 2 22 24 26 28 3 32 34 36 38 4 42 44 46 48 5 52 54 Concentration (µg/l) Figure 2. Calibration curves for quinoline and fenamiphos sulfone. 6

Testing of Drinking Water Samples EPA Method 538 was tested on several samples from river, reservoir and drinking water sources. The method detected only DIMP in one of the samples taken from a reservoir prior to drinking water treatment (Figure 3). The treated drinking water contained no detectable organophosphate pesticides. Thus, the method was found to be reliable and useful for the analysis of drinking water contaminants, as well as rapid and sensitive. A. Reservoir water B. Drinking water C. Internal standard Counts 1 2 6 4 2 181. & 97., 181. & 139. Ratio = 52.6 (125.9%) DIMP (181&97) 3.5 4. 4.5 5. Acquisition time (min) Counts 1 2 2.5 2. 1.5 1. 181. & 97., 181. & 139. Ratio = 89.9 (215.1%) 3.5 4. 4.5 5. Acquisition time (min) No confirmatory ion (89.9) Counts +MRM (195. & 99.) Drinking water s 1 4 1.75 1.5 1.25 1..75.5.25 4.153 min DIMP d-14 3.5 4. 4.5 5. Acquisition time (min) Figure 3. Analysis of the reservoir water prior to treatment (A.) and treated water (B.) for the pesticide DIMP using the modified Method 538. DIMP is detected using the 181 97 transition as the quantifier ion, and the 181 139 transition as the qualifier ion. In the case of the drinking water, the qualifier (confirmatory) ion is not present, resulting in a quantifier to qualifier ion ratio that is much too high, indicating the absence of DIMP in the drinking water. The deuterated DIMP internal standard is shown in C. Conclusions Running EPA Method 538 on the Agilent 129 Infinity LC System and the Agilent 646 Triple Quadrupole LC/MS System with Jet Stream Technology shortens time-to-results by almost a factor of three, and increases reliability of the method by adding a second transition. In addition, the detection limits and adaptations conform to the requirements of this method [1]. Reference 1. J.A. Shoemaker, 29, EPA Method 538: Determination of selected organic constituents in drinking water by direct aqueous injection-liquid chromatography/tandem mass spectrometry, EPA/6/R-9/149, 4p. For More Information These data represent typical results. For more information on our products and services, visit our Web site at www.agilent.com/chem. 7

www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., 212 Printed in the USA August 13, 212 599-967EN