Zero Carbon Building Energy Modelling Guidelines. October 31, 2017

Similar documents
Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Is Your Envelope Effective? BCBEC Luncheon January 29, 2009

PART 1 BUILDING ENVELOPE THERMAL ANALYSIS (BETA) GUIDE

Thermal Bridging and Whole Building Energy Performance

Energy modeling in IDA ICE according to ASHRAE , app. G

Interpretation Variables and Common Areas of Confusion. Of the 2009 IECC

ENERGY EFFICIENT RETROFIT OF A HIGH-RISE MULTIFAMILY BUILDING

The Concept of Linear and Point Transmittance and its Value in Dealing with Thermal Bridges in Building Enclosures

Bullitt Center s Energy Performance

1) For the purpose of this Section, the term common space shall mean all spaces required to

Example LEED-NC v2.1 Energy & Atmosphere Credit 1 Submittal

IMPACT OF COLUMNS AND BEAMS ON THE THERMAL RESISTANCE OF THE BUILDING ENVELOPE

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

Zero Emissions Building Plan 7/12/2016

White Paper ENVELOPE-FIRST APPROACH TO NET-ZERO ENERGY BUILDINGS

Thermal Performance of Nvelope NV1 Clip System

New Hampshire Residential Energy Code

Florida HERO Program Residential Eligible Product List All Products

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

California HERO Program Residential Eligible Product List All Products

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

INTRODUCTION TO WUFI PASSIVE & PHIUS+ 2015

Retrofit of an historical building toward NZEB

NEW CITY OF VANCOUVER REZONING REQUIREMENTS

HERO Program Residential Eligible Product List California Residential Eligible Products... 2

Green Building Guideline of Jordan

Thermal Performance of Nvelope NV1 Clip System

Asset Energy Calculator Guidance

Green Building Guideline of Jordan

Clarifying the Fenestration Energy Performance requirement in the Ontario Building Code Supplementary Standard SB12

Plan Check & Field Inspection Guide

Boulder City NV Prepared by (Print Name) Signature Date

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

Compliance Certificate

C H A P T E R 3. Completing the Residential Analysis Worksheet STEP 1: WINDOWS AND OTHER GLASS AREAS

The mal B idging. Thermal Bridging Part L1A A Practical Guide

ASHRAE Standard 90.1 App G, PHI and PHIUS+

The Effects of Set-Points and Dead-Bands of the HVAC System on the Energy Consumption and Occupant Thermal Comfort

Selecting Energy Efficient New Windows in Tennessee

ASHRAE 90.2 Kuwait What Can be Learned From It?

Selecting Energy Efficient New Windows in Nevada

Administrative Changes

Selecting Energy Efficient New Windows in Illinois

Selecting Energy Efficient Replacement Windows in Arizona

Optimization of air tightness and night ventilation for Passive houses in Italian climates under Fanger and Adaptive comfort models

Energy-Efficient Passive House using thermal mass to achieve high thermal comfort

Promoting Building Energy Efficiency through Performancebased Standards: Is it a Challenge? By Priyantha Bandara

The Role of Control Layers in Building Enclosure Design

Least Cost Path to Achieving 50% Reduction in Residential Energy Use (in Heating Climates)

Fenestration Energy Performance:

Thermal Bridging in Residential Construction

Phase Two Change Proposal for the Next Edition of the Building Code: 2-CC-B POTENTIAL CHANGE TO ONTARIO S BUILDING CODE:

Errata Sheet. LEED for Schools Reference Guide First Edition for the document titled:

Energy Trigger (A Existing Building Upgrade Mechanism Model)

Solar Energy Technologies

Assessment of the energy demand in energy-saving office buildings from the viewpoint of variations of internal heat gains

Great Ocean Rd Ice Creamery

THE GEORGIA ENERGY CODE: 2009 IECC + AMENDMENTS

Green Remodeling Illustrations GREEN REMODELING ILLUSTRATIONS GREEN BUILDING GUIDELINES FOR HOME REMODELING

Project name RetroPHit 04 - Steel Frame Bungalow Project summary A steel framed, brick clad bungalow built off a concrete raft foundation

Solar Hot Air Collectors. Rob Taisey Assured Solar Energy

Modeling for LEED. Refer to Additional LEED credits on page 6 90 for a list of credits TRACE 700 may help to achieve.

Italcementi Center for Research and Innovation

Energy Simulation Tool Approval Technical Assistance Manual 2017 Florida Building Code, Energy Conservation

Project Description. Projected build start date 24 Dec 2004 Projected date of occupation. Energy target. Existing external wall construction

Computational and the real energy performance of a single-family residential building in Poland an attempt to compare: a case study

ASHRAE 62.2: What s New in 2016

EnerPHit. Criteria for Residential-Use Refurbished Buildings

Of Building Science: From Control Layers to High Performance Enclosures

APPROVED. Acceptable to the code official for compliance with the provisions of the applicable Code or referenced Standard.

2017 Metrics Research

National Calculation Methodology (NCM) modelling guide (for buildings other than dwellings in England*)

National Calculation Methodology (NCM) modelling guide (for buildings other than dwellings in England and Wales) 2010 Edition

Building Regulations Part L2 (2006) & Part F VE-SBEM User Guide <Virtual Environment> 6.0

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

CHAPTER 1: OVERVIEW OF ENERGY EFFICIENT CONSTRUCTION

Passive House in Canada: Case Studies on a Near EnerPHit Retrofit and Post-Occupancy Research

Airspace R-Values. Educational Overview. Revised 12/6/2016

LEED v4 Credit Guidance for Andersen Products LEED for Building Design and Construction: Homes and Multifamily Midrise

Chilled Beams. The new system of choice?

M 158 DEPOSITED. April 7, 2017 B.C.REG.

SOLAR XXI: A Portuguese Office Building towards Net Zero-Energy Building

Energy Code Basics for Residential Buildings. Presented by Newport Ventures NEWPORT VENTURES

Chapel House- Design Process- Envelope and Energy savings

Passive House 2.0 LESSONS LEARNED FROM THE FIRST GENERATION OF MULTI-UNIT PASSIVE HOUSE BUILDINGS IN B.C.

Understanding the National Energy Code of Canada for Buildings, 2011

2014 California Advanced Homes Program

2012 CLEAResult All rights reserved. Residential Energy Efficiency

Best Practice Recommendations for Wall Retrofit on the Two-Story Flexible Research Platform (FRP) at Oak Ridge National Laboratory (ORNL).

Building Envelope Commissioning and Building Diagnostic Test: Case Studies Course Number: CXENERGY1506

ISO INTERNATIONAL STANDARD. Energy performance of buildings Calculation of energy use for space heating and cooling

780 CMR: 9 th Edition Massachusetts State Building Code. Presented to: BSA Codes Committee. DATE: January 20, 2016

National Calculation Methodology (NCM) modelling guide (for buildings other than dwellings in Wales)

ENERGY AUDITOR STUDY GUIDE

Energy Efficiency Programs

ARCH 5901 A02 Office Building Program FALL 2015

2003 International Residential Building Code

Transcription:

Zero Carbon Building Energy Modelling Guidelines October 31, 2017

Contents 1. INTRODUCTION... 3 1.1 DEFINITIONS... 4 2. CALCULATING TEDI... 5 2.1 INTERNAL HEAT GAINS... 6 2.2 CALCULATING BUILDING ENVELOPE HEAT LOSS... 6 2.2.1 OPAQUE ASSEMBLIES... 7 2.2.2 FENESTRATION AND DOORS... 8 2.2.3 INFILTRATION... 8 3. ADDITIONAL CALCULATION GUIDANCE... 10 3.1 CALCULATING ENERGY USE INTENSITY... 10 3.2 CALCULATING PEAK DEMAND... 10 3.3 CALCULATING RENEWABLE ENERGY... 10 3.3.1 CALCULTING EXPORTED RENEWABLE ENERGY... 10 3.4 GENERAL MODELLING NOTES... 10 4. REPORTING GUIDANCE... 11 4.1 REPORTING TEDI... 11 4.2 REPORTING ENERGY USE INTENSITY... 11 4.3 REPORTING PEAK DEMAND... 11 4.4 REPORTING EXPORTED RENEWABLE ENERGY... 11 October 31, 2017 Page 2

1. INTRODUCTION This document has been created to provide clarity for energy modelling performed in support of Zero Carbon Building Design certification, primarily in regards to the determination of Thermal Energy Demand Intensity. It also provides additional information on how to account for eported, onsite renewable energy and peak demand. The epectation is that energy models used for compliance with the CaGBC s Zero Carbon Building Standard ( the standard ) will be developed to represent the actual anticipated operation of the facility for all energy uses on site. Stipulated conditions such as schedules, occupancy, receptacle loads, and DHW loads shall be based on actual intended operational conditions for the facility in question. It is epected that the energy modelling professional will communicate with the client and facility operations staff to understand building operations as best as possible so that hours of operation and equipment run times are understood rather than relying on arbitrary defaults from software or applicable code or standards. Software limitations shall not ecuse the limitation of accuracy of energy modelling to show compliance with the standard; consultants are epected to overcome any software limitations with appropriate engineering calculations. All other modelling inputs not discussed in these guidelines shall follow accepted industry best practice. As the standard relies heavily on Energy Star Portfolio Manager to calculate building energy and emissions performance, applicants to the standard should consult the technical guidelines on the Portfolio Manager access page for clarity on any other definitions and methodology. Clarity on all requirements of the Zero Carbon Building Standard can be found on the CaGBC website. October 31, 2017 Page 3

1.1 DEFINITIONS Clear Field An opaque wall or roof assembly with uniformly distributed thermal bridges, which are not practical to account for on an individual basis for U-value calculations. Eamples of thermal bridging included in the Clear Field are brick ties, girts supporting cladding, and studs. The heat loss associated with a Clear Field assembly is represented by a U-value (heat loss per unit area). Greenhouse Gas Intensity (GHGI) The total greenhouse gas emissions associated with all energy use on the building site. GHGI shall be reported in kg CO 2 e/m 2 /year. See the Portfolio Manager Technical Reference on GHG Emissions for more details on how to calculate building GHGI. Interface Details Thermal bridging related to the details at the intersection of building envelope assemblies and/or structural components. Interface details interrupt the uniformity of a clear field assembly and the additional heat loss associated with interface details can be accounted for by linear and point thermal transmittances (heat loss per unit length or heat loss per occurrence). Gross Floor Area (GFA) The total property floor area, measured between the outside surface of the eterior walls of the building(s). This includes all areas inside the building(s), including supporting areas. Peak Demand The building s highest electrical load requirement on the grid in a year, measured and reported in kw, reflecting any peak shaving impacts from demand management strategies including onsite power generation and energy storage. Thermal Energy Demand Intensity (TEDI) The annual heat loss from a building s envelope and ventilation, after accounting for all passive heat gains and losses. October 31, 2017 Page 4

2. CALCULATING TEDI TEDI is intended to represent the heat delivered to the building, including any etra heat that may be required due to the use of inefficient HVAC systems (e.g., reheat energy in VAV systems). It also includes any heat provided by waste heat sources (e.g., recovered heat from cooling systems, waste heat supply from cogeneration, etc.) as part of the heating requirement of the building. Only heat recovered by ehaust air is eempted. TEDI [ kwh kwh Space and Ventilation Heating Output [ m 2 year ] = year ] Modelled Floor Area [m 2 ] Understanding TEDI The use of a thermal energy metric requires building designers to optimize building characteristics related directly to heating. Orientation, solar access, building envelope performance, and other passive design measures must be addressed to ensure a low TEDI. The efficient delivery and waste heat recovery of ventilation air are also captured by the TEDI metric, and are measures that are best implemented in new construction and major renovations (rather than eisting buildings). Performance limits have been developed such that both architectural and ventilation measures must both be addressed to minimum levels of best practice. The methodology presented in Section 2 should be used in all cases to determine or calculate TEDI from energy models to ensure consistency, regardless of HVAC system type used. Note that in the event that building design involves situations that are not specifically accounted for in Section 2, the definition noted in Section 1.1 should be used to guide calculations and energy model inputs. When measured with modelling software, TEDI is the amount of heating energy delivered to the project that is outputted from any and all types of heating equipment, per unit of Modelled Floor Area. Heating equipment includes: Electric, gas, hot water, or DX heating coils of central air systems (e.g., make-up air units, air handling units, etc.); Terminal equipment (e.g., baseboards, fan coils, heat pumps, VRF terminals, reheat coils, etc.), and/or; Any other equipment used for the purposes of space conditioning and ventilation. The heating output of any heating equipment that uses a source of heat that is not directly provided by a utility (electricity, gas or district) must still be counted towards the TEDI. For eample, heating from heating coils of any type that use a heat source derived from waste heat (e.g., from a cooling system or process such as a heat pump or VRF terminal unit, cogeneration waste heat that serves a building hot water loop connected to those heating coils) or a renewable energy source (e.g., solar thermal hot water collectors) must still be counted towards the TEDI. While every type of software has different reporting features, TEDI can be calculated by summing up the heating output of all the heating coils in the building. October 31, 2017 Page 5

Specific eamples of heating energy that would not be included in the TEDI include but are not limited to: Maintaining swimming pool water temperatures Outdoor comfort heating (e.g., patio heaters, eterior fireplaces) Gas-fired appliances (stoves, dryers) Heat tracing 2.1 INTERNAL HEAT GAINS Incidental heat gains from lighting, receptacle loads, pumps, fans etc. shall be included in the energy model and reflect the design of the building. Operational schedules should reasonably reflect the epected operations of the building and should be developed in consultation with the building owner and/or operator. This effectively means that these internal heat gains become credits in the TEDI that will automatically be calculated by the energy modelling software. 2.2 CALCULATING BUILDING ENVELOPE HEAT LOSS The ZCB-Design standard requires buildings to achieve a specific performance limit in TEDI, which is primarily a representation of the annual heating load required to offset envelope heat loss and ventilation loads. Choosing TEDI as a target helps to encourage energy efficient building envelopes. However, building envelope heat loss has historically been simplified due to past difficulties in costeffectively providing more accuracy. This has generally led to overly optimistic assessments of building envelope performance by way of ignoring or underestimating the impact of thermal bridging. Building envelope thermal bridging elements that can have a significant impact on heat loss that have historically been underestimated or unaccounted for include: Assemblies with thermal bridging elements that are not quantified by codes or standards, such as those with various types of cladding attachments (girts, clips, etc.) and spandrel panels; Floor slab thermal bridges, including balcony slabs, window wall slab by-pass and connection details, shelf angles, etc.; Window to wall transitions; Parapets; Corners and interior wall intersection details; At-grade transition details; and Large structural penetrations. October 31, 2017 Page 6

With the recent addition of industry resources that support more efficient and accurate calculations of building envelope heat loss 1, assemblies and associated thermal bridging elements must be accurately quantified for the purposes of complying with the standard, according the requirements below. 2.2.1 OPAQUE ASSEMBLIES The overall thermal transmittance of opaque building assemblies shall account for the heat loss of both the Clear Field performance, as well as the heat loss from Interface Details. Additional heat loss from Interface details are to be incorporated in the modelled assembly U-values, according to the provisions below. Overall opaque assembly U-values can be determined using any of or a combination of the following hierarchy of approaches: a. Using the performance data for Clear Fields and Interface Details from the Building Envelope Thermal Bridging Guide (BETBG), and the calculation methodology as outlined in 3.4 of the BETBG. A detailed eample is provided in Section 5 of the BETBG and a supporting calculation spreadsheet is available from bchydro.com/construction, titled Enhanced thermal performance spreadsheet ; b. Using the performance data for Clear Field and Interface Details from other reliable resources such as ASHRAE 90.1-2010, Appendi A, ISO 14683 Thermal bridges in building construction Linear thermal transmittance Simplified Methods and default values, with the methodology described above in a; c. Calculations, carried out using the data and procedures described in the ASHRAE Handbook Fundamentals; d. Two or three dimensional thermal modelling, or; e. Laboratory tests performed in accordance with ASTM C 1363, Thermal Performance of Building materials and Envelope Assemblies by Means of a Hot Bo Apparatus, using an average temperature of 24±1 C and a temperature difference of 22±1 C. Ecept where it can be proven to be insignificant (see below), the calculation of the overall thermal transmittance of opaque building envelope assemblies shall include the following thermal bridging effect elements: Closely spaced repetitive structural members, such as studs and joists, and of ancillary members, such as lintels, sills and plates; Major structural penetrations, such as floor slabs, beams, girders, columns, curbs or structural penetrations on roofs and ornamentation or appendages that substantially or completely penetrate the insulation layer; The interface junctions between building envelope assembles such as: roof to wall junctions and glazing to wall or roof junctions; 1 See, for eample, the Building Envelope Thermal Bridging Guide (BETBG), Version 1.1. https://www.bchydro.com/content/dam/bchydro/customer-portal/documents/power-smart/buildersdevelopers/building-envelope-thermal-bridging-guide-1.1.pdf October 31, 2017 Page 7

Cladding structural attachments including shelf angles, girts, clips, fasteners and brick ties; and The edge of walls or floors that intersect the building enclosure that substantially or completely penetrate the insulation layer. The following items need not be taken into account in the calculation of the overall thermal transmittance of opaque building envelope assemblies: Mechanical penetrations, such as pipes, ducts, equipment with through-the-wall venting, packaged terminal air conditioners or heat pumps; The impact of remaining small unaccounted for thermal bridges where the epected cumulative heat transfer though these thermal bridges is so low that the effect does not change the overall thermal transmittance of the above grade opaque building envelope by more than 10%. 2.2.2 FENESTRATION AND DOORS The overall thermal transmittance of fenestration and doors shall be modelled according to their intended actual performance, including the impact of framing for the actual or anticipated window sizes used in the design. The general approach for determining performance shall be in accordance with NFRC 100, Determining Fenestration Product U-factors, with the following limitations: The thermal transmittance for fenestration shall be based on the actual area of the windows and not the standard NRFC 100 size for the applicable product type. It is acceptable to areaweight the modelled fenestration U-value based on the relative proportions of fied and operable windows and window sizes. It is also acceptable to simplify the calculations by assuming the worst case by using the highest window U-value for all fenestration specified on the project. If the fenestration or door product is not covered by NFRC 100, the overall thermal transmittance shall be based on calculations carried out using the procedures described in the ASHRAE Handbook Fundamentals, or Laboratory tests performed in accordance with ASTM C 1363, Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Bo Apparatus, using an indoor air temperature of 21±1 C and an outdoor air temperature of -18±1 C measured at the mid-height of the fenestration or door. 2.2.3 INFILTRATION Infiltration shall be modelled at 0.00025 m³/s/m² or 0.05 cfm/ft² of total (at 5 Pa), above grade gross wall area (i.e. walls and windows), unless air leakage testing will be conducted to verify alternate values. Air leakage testing values determined at 75 Pa can be approimately converted for use in the energy model using a constant value by multiplying the tested value at 75 Pa by 0.112 (as per formula below). For eample, a tested value of 0.0015 m³/s/m² at 75 Pa would October 31, 2017 Page 8

equate to 0.000168 m³/s/m², which can then be used in the energy model, instead of the 0.00025 m³/s/m² indicated. Other conversions are allowable using suitable engineering calculations. m 3 m 3 (Model Input Air Leakage @5 Pa [ s ] ) = (Measured Air Leakage @75 Pa [ s m2 m 2 ] ) ( 0.112 ) October 31, 2017 Page 9

3. ADDITIONAL CALCULATION GUIDANCE 3.1 CALCULATING ENERGY USE INTENSITY Applicants to the ZCB program shall report their Energy Use Intensity (EUI). EUI refers to the sum of all site (not source) energy consumed on site (e.g., electricity, natural gas, district heat), including all process energy, divided by the building gross floor area. This metric shall be a direct output of the energy model. 3.2 CALCULATING PEAK DEMAND Applicants to the ZCB program shall report their Peak Demand. This metric shall be a direct output of the energy model, averaged over a one hour time-step. For models that use sub-hourly time-steps, an average hourly value shall be used. 3.3 CALCULATING RENEWABLE ENERGY Renewable energy can be determined using one of the following methods: If the building simulation program is capable of modelling the on-site renewable energy then those systems can be modelled directly within the design building energy model. If the building simulation program is not capable of modelling the on-site renewable systems, or the modeller prefers to use different software, those systems can be modelled using a renewable energy system model that utilizes the same weather file as the design energy model. The energy displaced by these systems can be subtracted from the building energy model results. 3.3.1 CALCULTING EXPORTED RENEWABLE ENERGY Applicants must provide calculations for the avoided emissions from onsite renewable energy that is eported, using the marginal provincial CO2e factors. Eported renewable energy is defined as any renewable energy that is generated onsite in ecess of the buildings requirement at a given time-step (i.e., hourly or sub-hourly). The sum of the eported renewable energy over a year can only be calculated using an hourly or sub-hourly energy model that includes both the building energy consumption and renewable energy generation or separate hourly or sub-hourly energy models for the building and renewable energy system that utilize the same weather file as input. It is not sufficient to provide an annual balance of renewable energy generation since the emissions factors are different whether the site is using the onsite renewable energy (i.e., uses average emissions factors) or whether it is being eported to the grid (i.e, uses marginal emissions factors). 3.4 GENERAL MODELLING NOTES The epectation is that energy models used for compliance with the standard will be developed to represent the actual anticipated operation of the facility for all energy uses on site. This will require the modelling professional to communicate with the client and facility operations staff to understand the building rather than relying on arbitrary defaults from software, or applicable codes and standards. October 31, 2017 Page 10

4. REPORTING GUIDANCE 4.1 REPORTING TEDI The modelled TEDI performance of the building shall be reported in kwh/m2/year. 4.2 REPORTING ENERGY USE INTENSITY The modelled site EUI of the building shall be reported in kwh/m2/year, calculated based on the total predicted annual energy consumption from the whole building energy simulation divided by the gross floor area. 4.3 REPORTING PEAK DEMAND The modelled Peak Demand of the building must be reported in kw, including the date and time when the peak is modelled to occur. 4.4 REPORTING EXPORTED RENEWABLE ENERGY The modelled eported renewable energy for the building must be reported in kwh. October 31, 2017 Page 11