R CODE CHANGE PROPOSAL FORM (See instructions on page 2)

Similar documents
Chapter 2 EARTHQUAKE-RESISTANCE REQUIREMENTS

R Code and Commentary for 2012 NC Residential Code final 03/06/13

130 MPH EXPOSURE B WFCM GUIDE. Guide to Wood Frame Construction in High Wind Areas for One- and Two-Family Dwellings 2015 EDITION

Administrative Changes

The following are details of the code requirements of the 2015 International Residential Code for single-story decks.

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

PRESENTATION OUTLINE MUBEC & IRC APPLICABILITY & ADMIN. 6/17/2015 RESIDENTIAL STRUCTURAL SYSTEMS. Carmen B. Bombeke, P.E.

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

SDPWS. Special Design Provisions for Wind & Seismic 2015 EDITION

Part III Building Planning and Construction

FACT SHEET #2 DECK INFORMATION

What is Conventional Construction?

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

2012 Wood Frame Construction Manual: Wind Load Distribution on Buildings Load Paths

Residential Wood Deck Design

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

SECTION PLATE CONNECTED WOOD TRUSSES

Lintel Tables Design Notes and Limitations

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

WIND & SEISMIC 2008 EDITION ASD/LRFD WITH COMMENTARY. American Forest & Paper Association. American Wood Council ANSI/AF&PA SDPWS-2008

2003 International Residential Building Code

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

Heel Blocking Requirements and Capacity Analysis. Overview Revised 3/22/2017

REINFORCING TABLES INSTALLATION MANUAL

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: LOUISIANA PACIFIC CORPORATION

INSPECTION GUIDELINES: STRUCTURAL INSULATED PANELS (SIPs)

MAT109: Introduction to the Wood Frame Construction Manual

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE

Originally Issued: 05/20/2013 Revised: 07/07/2017 Valid Through: 05/31/ Design

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

Guide to Attaching Exterior Wall Coverings through Foam Sheathing to Wood or Steel Wall Framing

LPI 56 Technical Guide

INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

CALCULATING WIND LOADS ON LOW-RISE STRUCTURES PER 2015 WFCM ENGINEERING PROVISIONS (STD342-1)

Copyright. magazine. CFS Load Bearing Construction

BEARING METAL STUD FRAMING

BUILDING BULLETIN One and Two Family Dwellings Decks and Residential Access Ramps

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

10/23/2011. Plan Examination. Plan ExaminationPurpose. Catch problems in advance of construction.

Individual Truss Marking Is it a Building Code Requirement?

Wood Frame Construction Manual for One- and Two-Family Dwellings 2015 EDITION WORKBOOK

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

PRESCRIPTIVE COMPLIANCE METHOD

AC R1 # Triangle Parkway Suite 100 Norcross, Ga Phone: Fax: AC R1. September 11, 2012

Sponsored by The Boston Association of Structural Engineers and the Structural Engineers Association of Massachusetts

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

Special Inspections for Wood Construction BCD710 Michelle Kam-Biron, PE, SE, SECB Senior Director, Education American Wood Council

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

ILLUSTRATED GUIDE. For Seismic Design of Houses. Lateral Bracing Requirements Part 9 BC Building Code 2012

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

PR-L274 Nordic Structures Revised April 16, 2017

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

Originally Issued: 12/18/2015 Revised: 04/14/2017 Valid Through: 12/31/2017

Structural Inspection

COVERED AND SCREENED PORCHES: WHAT YOU NEED TO KNOW

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015

4.2 Tier 2 Analysis General Analysis Procedures for LSP & LDP

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: AFM CORPORATION

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

RB Appendix R (New)

ESR-2269 Reissued November 1, 2008 This report is subject to re-examination in one year.

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

ATI Evaluation Service A Division of Architectural Testing Certification Services

Gold Bond BRAND Gypsum Sheathing

Prescriptive Design for Pole Barns Using the Larimer County Prescriptive Handout

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I-JOISTS REPORT HOLDER: PACIFIC WOODTECH CORPORATION

STRUCTURAL TESTS AND SPECIAL INSPECTIONS

Diaphragms 2. Design Process. Design Process. Diaphragms are the roofs and floors of the upper stories

CITY OF BRISTOL DECK CONSTRUCTION GUIDE ACCORDING TO THE 2012 IRC WITH THE 2016 CT AMMENDMENTS

Joint Evaluation Report ICC-ES (800) (562)

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

Structural Technical Report 1 Structural Concepts / Structural Existing Conditions Report

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

Building Design Data

The designer shall also submit additional information required by the University as described and underlined below.

LP OSB Sheathing & Structural 1 Sheathing

Table of Contents.2. Introduction...3 Gravity Loading and Deflections..4. Existing Structural System..8

Introducing TJ Insulated Structural Framing Components

Project Address: Name of Person Completing Form:

Structural Redesign Gravity System

Supplemental Concrete Tilt Up Retrofit Plan Check Correction Sheet (2014 LABC)

LVL Product Guide 2.0E LVL 1.5E LVL

Structural vs Nonstructural Members. Roger LaBoube, Ph.D., P.E. Wei-Wen Yu Center for Cold-Formed Steel Structures

Structural Comparison between Pan Joist Concrete and Steel Frame Systems for UMCP Student Housing Building B

APPENDIX R STRAWBALE CONSTRUCTION

Transcription:

CODE CHANGE PROPOSAL FORM (See instructions on page 2) Code: IRC 12/13 Sections 301.2.2.2.1 Proponent: Charles S. Bajnai, Chesterfield County, VA, ICC Building Code Action Committee 1. Delete as shown R301.2.2.2.5 Irregular buildings. The seismic provisions of this code shall not be used for irregular structures located in Seismic Design Categories C, D0, D1 and D2. Irregular portions of structures shall be designed in accordance with accepted engineering practice to the extent the irregular features affect the performance of the remaining structural system. When the forces associated with the irregularity are resisted by a structural system designed in accordance with accepted engineering practice, design of the remainder of the building shall be permitted using the provisions of this code. A building or portion of a building shall be considered to be irregular when one or more of the following conditions occur: 1. When exterior shear wall lines or braced wall panels are not in one plane vertically from the foundation to the uppermost story in which they are required. Exception: For wood light-frame construction, floors with cantilevers or setbacks not exceeding four times the nominal depth of the wood floor joists are permitted to support braced wall panels that are out of plane with braced wall panels below provided that: 1. Floor joists are nominal 2 inches by 10 inches (51 mm by 254 mm) or larger and spaced not more than 16 inches (406 mm) on center. 2. The ratio of the back span to the cantilever is at least 2 to 1. 3. Floor joists at ends of braced wall panels are doubled. 4. For wood-frame construction, a continuous rim joist is connected to ends of all cantilever joists. When spliced, the rim joists shall be spliced using a galvanized metal tie not less than 0.058 inch (1.5 mm) (16 gage) and 11/2 inches (38 mm) wide fastened with six 16d nails on each side of the splice or a block of the same size as the rim joist of sufficient length to fit securely between the joist space at which the splice occurs fastened with eight 16d nails on each side of the splice; and 5. Gravity loads carried at the end of cantilevered joists are limited to uniform wall and roof loads and the reactions from headers having a span of 8 feet (2438 mm) or less. 2. When a section of floor or roof is not laterally supported by shear walls or braced wall lines on all edges. Exception: Portions of floors that do not support shear walls or braced wall panels above, or roofs, shall be permitted to extend no more than 6 feet (1829 mm) beyond a shear wall or braced wall line. 3. When the end of a braced wall panel occurs over an opening in the wall below and ends at a horizontal distance greater than 1 foot (305 mm) from the edge of the opening. This provision is applicable to shear walls and braced wall panels offset in plane and to braced wall panels offset out of plane as permitted by the exception to Item 1 above.

Exception: For wood light-frame wall construction, one end of a braced wall panel shall be permitted to extend more than 1 foot (305 mm) over an opening not more than 8 feet (2438 mm) wide in the wall below provided that the opening includes a header in accordance with the following: 1. The building width, loading condition and framing member species limitations of Table R502.5(1) shall apply; and 2. Not less than one 2 12 or two 2 10 for an opening not more than 4 feet (1219 mm) wide; or 3. Not less than two 2 12 or three 2 10 for an opening not more than 6 feet (1829 mm) wide; or 4. Not less than three 2 12 or four 2 10 for an opening not more than 8 feet (2438 mm) wide; and 5. The entire length of the braced wall panel does not occur over an opening in the wall below. 4. When an opening in a floor or roof exceeds the lesser of 12 feet (3658 mm) or 50 percent of the least floor or roof dimension. 5. When portions of a floor level are vertically offset. Exceptions: 1. Framing supported directly by continuous foundations at the perimeter of the building. 2. For wood light-frame construction, floors shall be permitted to be vertically offset when the floor framing is lapped or tied together as required by Section R502.6.1. 6. When shear walls and braced wall lines do not occur in two perpendicular directions. 7. When stories above grade plane partially or completely braced by wood wall framing in accordance with Section R602 or steel wall framing in accordance with Section R603 include masonry or concrete construction. Exception: Fireplaces, chimneys and masonry veneer as permitted by this code. When this irregularity applies, the entire story shall be designed in accordance with accepted engineering practice. 2. Revise as follows: R301.2.2.1.2 Alternative determination of Seismic Design Category E. Buildings located in Seismic Design Category E in accordance with Figure R301.2(2) are permitted to be reclassified as being in Seismic Design Category D 2 provided one of the following is done: 2.3. The building and portions of the building is constructed in accordance to the requirements for structures assigned to Seismic Design Category D2 elsewhere in this code. is within all of the requirements of Section R301.2.2.2.5 for being considered as regular. (Items not shown remain unchanged) R502.2 Design and construction. Floors shall be designed and constructed in accordance with the provisions of this chapter, Figure R502.2 and Sections R317 and R318 or in accordance with AF&PA/NDS. R502.2.1 Framing at braced wall lines. A load path for lateral forces shall be provided between floor framing and braced wall panels located above or below a floor, as specified in Section R602.10.8.

R502.2.2 Vertically offset floor diaphragms in Seismic Design Category C, D0, D1 and D2. In structures or portions of structures in Seismic Design Category C, D0, D1 and D2, floor diaphragms or portions of floor diaphragms shall not be vertically offset. Exceptions: 1. Framing supported directly by continuous foundations at the perimeter of the building. 2. For wood light-frame construction, floors shall be permitted to be vertically offset when the floor framing is lapped or tied together as required by Section R502.6.1. R502.3.3 Floor cantilevers. Floor cantilever spans shall not exceed the nominal depth of the wood floor joist. Floor cantilevers constructed in accordance with Table R502.3.3(1) shall be permitted when supporting a light frame bearing wall and roof only. Floor cantilevers supporting an exterior balcony are permitted to be constructed in accordance with Table R502.3.3(2). R502.3.3.1 Floor cantilevers in Seismic Design Categories D0, D1 or D2. Floor cantilevers supporting braced wall panels in all structures assigned to Seismic Design Categories D0, D1 or D2 and in townhouses in Seismic Design Category C shall be constructed in accordance with Section R602.10.9. Change Table R502.3.3(1), footnote f reference as shown (No change to table) (Footnotes not shown remain unchanged) f. See Section R301.2.2.2.5, R602.10.9 Item 1, for additional limitations on cantilevered floor joists for detached one- and two-family all dwellings in Seismic Design Category D0, D1, or D2 and townhouses in Seismic Design Category C., D0, D1 or D2. R502.10 Framing of openings. Openings in floor framing shall be framed with a header and trimmer joists. When the header joist span does not exceed 4 feet (1219 mm), the header joist may be a single member the same size as the floor joist. Single trimmer joists may be used to carry a single header joist that is located within 3 feet (914 mm) of the trimmer joist bearing. When the header joist span exceeds 4 feet (1219 mm), the trimmer joists and the header joist shall be doubled and of sufficient cross section to support the floor joists framing into the header. Approved hangers shall be used for the header joist to trimmer joist connections when the header joist span exceeds 6 feet (1829 mm). Tail joists over 12 feet (3658 mm) long shall be supported at the header by framing anchors or on ledger strips not less than 2 inches by 2 inches (51 mm by 51 mm).

R502.10.1 Framing of openings in Seismic Design Categories C, D0, D1 and D2. In all structures in Seismic Design Category D0, D1 or D2 and in townhouses in Seismic Design Category C, where an opening in a floor exceeds the lesser of 12 feet (3658 mm) or 50 percent of the least floor dimension that portion of the structure shall be designed in accordance with accepted engineering practice to the extent the opening affects the performance of the remaining structural system. R602.10 Wall bracing. Buildings shall be braced in accordance with this section or, when applicable, Section R602.12. Where a building, or portion thereof, does not comply with one or more of the bracing requirements in this section, those portions shall be designed and constructed in accordance with Section R301.1. In all structures in Seismic Design Category D0, D1 or D2 and in townhouses in Seismic Design Category C, stories above grade plane partially or completely braced by wood wall framing in accordance with this Section shall not include masonry or concrete construction or the entire story shall be designed in accordance with accepted engineering practice. Exception: Fireplaces, chimneys and masonry veneer as permitted by this code. R603.1.1 Applicability limits. The provisions of this section shall control the construction of exterior cold-formed steel wall framing and interior load-bearing cold-formed steel wall framing for buildings not more than 60 feet (18 288 mm) long perpendicular to the joist or truss span, not more than 40 feet (12 192 mm) wide parallel to the joist or truss span, and less than or equal to three stories above grade plane. All exterior walls installed in accordance with the provisions of this section shall be considered as loadbearing walls. Cold-formed steel walls constructed in accordance with the provisions of this section shall be limited to sites subjected to a maximum design wind speed of 110 miles per hour (49 m/s) Exposure B or C and a maximum ground snow load of 70 pounds per square foot (3.35 kpa). In all structures in Seismic Design Category D0, D1 or D2 and in townhouses in Seismic Design Category C, stories above grade plane walls partially or completely braced by cold-formed wall framing in accordance with this Section shall not include masonry or concrete construction or the entire story shall be designed in accordance with accepted engineering practice. Exception: Fireplaces, chimneys and masonry veneer as permitted by this code. R602.10.9 Braced wall panel support. Braced wall panel support shall be provided as follows: 1. Cantilevered floor joists complying with Section R502.3.3 shall be permitted to support braced wall panels. In all structures in Seismic Design Category D0, D1 and D2 and in townhouses in Seismic Design Category C, cantilevered floor joists supporting braced wall panels shall also comply with all the following: 1. Floor joists shall be nominal 2 inches by 10 inches (51 mm by 254 mm) or larger and spaced not more than 16 inches (406 mm) on center. 2. The ratio of the back span to the cantilever shall be at least 2 to 1. 3. Floor joists at ends of braced wall panels shall be doubled. 4. For wood-frame construction, a continuous rim joist shall be connected to ends of all cantilever joists. When spliced, the rim joists shall be spliced using a galvanized metal tie not less than 0.058 inch (1.5 mm) (16 gage) in thickness and 11/2 inches (38 mm) in width fastened with six 16d nails on each side of the splice or a block of the same size as the rim joist of sufficient length to fit securely between the joist space at which the splice occurs fastened with eight 16d nails on each side of the splice; and

5. Gravity loads carried at the end of cantilevered joists shall be limited to uniform wall and roof loads and the reactions from headers having a span of 8 feet (2438 mm) or less. 2. Elevated post or pier foundations supporting braced wall panels shall be designed in accordance with accepted engineering practice. 3. Masonry stem walls with a length of 48 inches (1219 mm) or less supporting braced wall panels shall be reinforced in accordance with Figure R602.10.9. Masonry stem walls with a length greater than 48 inches (1219 mm) supporting braced wall panel s shall be constructed in accordance with Section R403.1 Methods ABW and PFH shall not be permitted to attach to masonry stem walls. 4. Concrete stem walls with a length of 48 inches (1219 mm) or less, greater than 12 inches (305 mm) tall and less than 6 inches (152 mm) thick shall have reinforcement sized and located in accordance with Figure R602.10.9. 5. In all structures in Seismic Design Category D0, D1 or D2 and in townhouses in Seismic Design Category C, the end of a braced wall panel over an opening in the wall below shall not extend a horizontal distance greater than 1 foot (305 mm) from the end of the panel to the edge of the opening. This provision is applicable to braced wall panels offset in plane and to braced wall panels offset out of plane as permitted by the exception to Item 1 above. Exception: For wood light-frame wall construction, one end of a braced wall panel shall be permitted to extend more than 1 foot (305 mm) over an opening not more than 8 feet (2438 mm) wide in the wall below provided that the opening includes a header in accordance with the following: 1. The building width, loading condition and framing member species limitations of Table R502.5(1) shall apply; and 2. Not less than one 2 12 or two 2 10 for an opening not more than 4 feet (1219 mm) wide; or 3. Not less than two 2 12 or three 2 10 for an opening not more than 6 feet (1829 mm) wide; or 4. Not less than three 2 12 or four 2 10 for an opening not more than 8 feet (2438 mm) wide; and 5. The entire length of the braced wall panel does not occur over an opening in the wall below. R802.9 Framing of openings. Openings in roof and ceiling framing shall be framed with header and trimmer joists. When the header joist span does not exceed 4 feet (1219 mm), the header joist may be a single member the same size as the ceiling joist or rafter. Single trimmer joists may be used to carry a single header joist that is located within 3 feet (914 mm) of the trimmer joist bearing. When the header joist span exceeds 4 feet (1219 mm), the trimmer joists and the header joist shall be doubled and of sufficient cross section to support the ceiling joists or rafter framing into the header. Approved hangers shall be used for the header joist to trimmer joist connections when the header joist span exceeds 6 feet (1829 mm). Tail joists over 12 feet (3658 mm) long shall be supported at the header by framing anchors or on ledger strips not less than 2 inches by 2 inches (51 mm by 51 mm). R802.9.1 Framing of openings in Seismic Design Categories C, D0, D1 and D2. In structures or portions of structures in Seismic Design Category C, D0, D1 or D2 when an opening in a roof exceeds the lesser of 12 feet (3658 mm) or 50 percent of the least roof dimension that portion of the structure shall be designed in accordance with accepted engineering practice to the extent the opening affects the performance of the remaining structural system. SECTION AJ104 EVALUATION OF AN EXISTING BUILDING

AJ104.1 General. The building official may require an existing building to be investigated and evaluated by a registered design professional in the case of proposed reconstruction of any portion of a building. The evaluation shall determine the existence of any potential non-conformities to these provisions, and shall provide a basis for determining the impact of the proposed changes on the performance of the building. The evaluation shall use the following sources of information, as applicable: 1. Available documentation of the existing building. 1.1. Field surveys. 1.2. Tests (nondestructive and destructive). 1.3. Laboratory analysis. Exception: Detached one- or two-family dwellings that comply with Section R102.7. are not irregular buildings under Section R301.2.2.2.5 and are not undergoing an extensive reconstruction shall not be required to be evaluated. Reason: This proposal is submitted by the ICC Building Code Action Committee (BCAC) The BCAC was established by the ICC Board of Directors to pursue opportunities to improve and enhance an assigned International Code or portion thereof. This includes both the technical aspects of the codes as well as the code content in terms of scope and application of referenced standards. Since its inception in July, 2011, the BCAC has held 6 open meetings and numerous workgroup calls which included members of the BCAC as well as any interested party to discuss and debate the proposed changes. Related documentation and reports are posted on the BCAC website at: http://www.iccsafe.org/cs/bcac/pages/default.aspx. This proposal is to remove the classifications of Irregular Structures from Section R301.2.2.2.5 and relocate the specific construction requirements into the applicable sections of the code where they are relevant. As currently written, the list of items defining Irregular Structures in high seismic categories is a laundry list of items that cause the structure to be outside of the scope of this code. Then, for most of the defined irregularities there is an exception including technical construction requirements that, when done, allow the structure to not be classified as Irregular. So, in essence, the current section of Irregular structures items are exceptions to the code. Then the exceptions to each item are exceptions to the exception. This makes poor code language. In addition, many code users are not aware of these requirements because they are located in Chapter 3. As an example, when a code user is looking to the code to determine how to construct cantilever floor joists, they would go to Chapter 5, Floor Framing. There is a section addressing cantilevers. However, in this section in Chapter 3 it says when a floor cantilevers and supports a wall above (not in the same vertical plane) it is irregular. Then the exception to the exception defines how to construct the floor so that it will not be considered irregular. The BCAC determined that it would be much better to actually include the cantilever construction requirements in the actual section in Chapter 5 that describes cantilevered floor construction. This proposal does not make any technical changes to the code. It merely moves the construction requirements and limitations therin to the applicable sections that already exist in Chapter 5, Floor framing, Chapter 6, Wall framing and Chapter 8 Roof framing. The limitations are still applicable and by relocating them they will be more noticeable and apparent. The current code already has language and provisions to cover construction that exceeds the limitations of this code. As shown below, R301.1 states that when, construction is in accordance with the provision of this code it is deemed to comply and the converse is true as well. When construction is NOT in accordance with the provisions it does not comply. Further, Section R301.1.3 it states that, elements exceeding the limits of Section R301 or otherwise not conforming to this code. shall require an engineered design. With the specific construction requirements now in the applicable code sections, those two provisions already exist and adequately address the cases when mandatory code requirements are exceeded. R301.1 Application. Buildings and structures, and all parts thereof, shall be constructed to safely support all loads, including dead loads, live loads, roof loads, flood loads, snow loads, wind loads and seismic loads as prescribed by this code. The construction of buildings and structures in accordance with the provisions of this code shall result in a system that provides a complete load path that meets all requirements for the transfer of all loads from their point of origin through the load-resisting elements to the foundation. Buildings and structures constructed as prescribed by this code are deemed to comply with the requirements of this section. R301.1.3 Engineered design. When a building of otherwise conventional construction contains structural elements exceeding the limits of Section R301 or otherwise not conforming to this code, these elements shall be designed in accordance with accepted engineering practice. The extent of such design need only demonstrate compliance of nonconventional elements with other applicable provisions and shall be compatible with the performance of the conventional framed system. Engineered design in accordance with the International Building Code is permitted for all buildings and structures, and parts thereof, included in the scope of this code.

The existing Section R301.2.2.2 defines limitations for the use and scope of this code for structures in Seismic Design Category C such as weights of materials, stone and masonry veneer, masonry and concrete construction. The existing Section R301.2.2.3 defines further limitations for Seismic Design Category D0, D1 and D2 in addition to the Seismic Design Category C limitations such as height limitations. These two sections remain as is and the current limitations apply. The net effect is the same and proposal makes the code much more user friendly and will prevent the oversight of the specific construction requirements and limitations that now exist in Chapter 3. Cost Impact: The code change does not change the existing requirements of the code and will not increase the cost of construction.