RSIC-1 RSIC-1 INSTALLATION GUIDE RSIC-1 SOUND ISOLATION CLIP CONCRETE CMU

Similar documents
RSIC-1. RSIC-1, the Low Cost, High Performance, Noise control Solution. RSIC-1 specifications:

RESILIENT SOUND ISOLATION CLIPS

Installation Guide and Safety Manual

Installation Guide April 2017

Fire Barrier Duct Wrap 615+

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: PAC INTERNATIONAL, LLC

SECTION GYPSUM BOARD ASSEMBLIES

SECTION GYPSUM BOARD

Insulated Fire-Rated Access Door Model(s): BIT/BIW/BIP

PinkWood Ltd. Revised September 29, 2017

Floor Insulation Underlayment Section Sound Control Matting

Container Installation Guide

Container Installation Guide

ENKASONIC FLOOR UNDERLAYMENT 9110

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

REPORT HOLDER: KINETICS NOISE CONTROL 6300 IRELAN PLACE DUBLIN, OHIO EVALUATION SUBJECT: KINETICS NOISE CONTROL WAVE HANGER

A new method for protecting construction joints and through-penetrations from fire, water, smoke and sound.

Drag Chain Conveyor Installation and Operation Manual

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

WHY I SHOULD SPECIFY AND USE FAS TRACK 1000?

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

I-STUD Shaftwall System

Endotherme Mat ES-5A-12

ON-FLOOR WIREWAY INSTALLATION GUIDE

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

FOR: CEMCO - California Expanded Metal Products Co. Sound Transmission Loss Test

Gold Bond brand /NGC. High Strength LITETM. Family of Products

Clarifying the Fenestration Energy Performance requirement in the Ontario Building Code Supplementary Standard SB12

3M Fire Barrier Moldable Putty Pads MPP+ Product Data Sheet

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

Se incluyen las instrucciones en español

ONE SCHOOL STREET SEPTEMBER 18, 2008 GOWANDA, NEW YORK ARCH PROJECT NO

Technical Data for. Headers. and Beams

Fire Protection Products

Albi DriClad FIREPROOFING APPLICATION MANUAL & FIELD GUIDE. Albi Manufacturing Division of StanChem, Inc. 401 Berlin Street East Berlin, CT USA

Appendix D. -Weyerhaeuser Fire Rated Assembly Listings-

Pittsburgh Corning ProVantage Glass Block Installation System Assembly Instructions

HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction.

Finestone Stucco System

3M Fire Barrier Duct Wrap 615+ Product Data Sheet and Installation Guide (Condensed Version)

BEARING METAL STUD FRAMING

The GlasRoc Shaftliner Type X advantage...

Shaftwall & Stairwell Systems Fire protection & sound isolation for shafts & stairwells

PS-31 (SUS304, 300 mm) PS-31 (SUS304, 1,000 mm)

Shaftwall and Area Separation Wall Systems.

BROADCAST: M BLOCKS, PLUGS, PLANKS NEW PRODUCT LAUNCH Date: June 16, 2016 Issued by: George Yoshida, Ted Colwell

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

where high efficiency is the standard

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: HOMASOTE COMPANY

SECTION GYPSUM WALLBOARD SYSTEMS. A. Gypsum board at new wall partitions or where indicated on drawings. B. ASTM C442 - Gypsum Backing Board

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

Document number CURTAIN FIRE DAMPERS

KNIGHT WALL SYSTEMS GUIDE DETAILS:

Infinity Perimeter Trim

Dura Rack Family Of Products. 237,000 sq. ft. manufacturing facility

Joint Systems. System No. FF-D-0044

RSIC-1 ACOUSTIC ASSEMBLY

Senturion TM III Wall System

Rev. 07 8/15 Please Read Disclaimers:

92831 TEL: (714) FAX:

CREATE YOUR OUTDOOR LIVING ROOM

Owner s Manual Shelf Lip Accessory

Document Number FD, DFD, SSFD, SSDFD, & KFD Models 11/2 and 3 Hour Curtain Fire Dampers Vertical and Horizontal Mount

Product Specifications MRI Trench Duct

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued October 1, Legacy report on the 1997 Uniform Building Code

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: ECORE INTERNATIONAL, INC.

138 H-STUD AREA SEPARATION WALL SYSTEM

SHOWER & TUB/SHOWER INSTALLATION

Free 17'x6' Chicken Run Plan. Designed for up to 11 chickens

A. Submit the following in addition to the standard requirements.

AND ACCESSORIES FOR DRYWALL CONSTRUCTION

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Expand your outdoor living space with TREX RainEscape Deck Drainage System

KS SERIES - VERTICAL INSTALLATION

Duracast Pressure Plate Installation Instructions

Fig. 1 - Standard Clevis Hanger

Wabo Modular STM and D Series Large movement expansion joint system

GLASS WALL SPECIFICATIONS

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

ALLMET CONTINENTAL INSTALLATION GUIDE

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

Lithonia Lighting Terms and Conditions of Sale

FireMaster FastWrap XL

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

VHB Tapes. Design Guide for Sign Assembly. Proven worldwide. Now even more versatile for more sign applications, more surfaces.

MS-2A LINER SPECIFICATIONS: for STRUCTURAL REPAIR and SEALING of MANHOLES

STEEL PIPE NIPPLES SEAMLESS Price Sheet PNS-9.16C Effective: September 5, 2016 Cancels Price Sheet PNS-10.15C of October 5, 2015

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

WheelTime Exchange Standard Terms and Conditions. ZF Services North America, LLC (ZFSNA) 9/1/2015 ZF SACHS Heavy Duty Clutch and Shocks

PERGO TimberCraft + WetProtect Limited Warranty for Floor Installations Only

Maximum thermal performance ISOLEREN INSULATED METAL PANELS INSTALLATION GUIDE

1. Interior gypsum wallboard. 2. Exterior gypsum board panels for ceilings and soffits. 3. Tile backing panels.

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.

Air and Vapor Barrier 3015

YOUR LITE-DECK SECTIONS

KNIGHT WALL SYSTEMS GUIDE DETAILS:

Pyroscat Duct Wrap XL

Transcription:

RSIC-1 INSTALLATION GUIDE RSIC-1 SOUND ISOLATION CLIP CONCRETE CMU RSIC-1

Drywall Furring Channel: Minimum Requirements: 25 gauge with hemmed edge required. Meets or exceeds SSMA requirements. Depth: 7/8 inch Width Bottom: 2-9/16 to 2-11/16 inch wide minimum. Width Top: 1-1/4 inch wide Splice drywall furring channel (hat track) with 6 inch overlap in mid span (between two clips) secure with 18 ga tie wire, or two 7/16 framing screws. Resilient Sound Isolation Clip (RSIC-1) Maximum Spacing: 48 inches on center Maximum Acoustical Design Load: 36 lbs Fasteners: RSIC-1 to Concrete or CMU: Min 1/4 x 2 drive spike, 1/4 x 2 tapcon, 2 shoot in pin with washer, or product with equal load capabilities (Minimum 120lbs Ultimate, Sheer and Pullout). Call for information on additional approved fasteners. RSIC-1 Dimensions: 3 RSIC-1 clip 3 tall RSIC-1 clip 1-1/4 deep RSIC-1 and drywall furring channel 1-5/8 deep Average Labor Rates: 1-1/4 1-5/8 RSIC-1: 60 clips per man hour Drywall Furring Channel: 550LF per man hour Labor rates provided to PAC International, Inc by an independent contracting firm.

Walls: Resilient Sound Isolation Clips (RSIC-1) shall be 48 inches (1219mm) on center maximum. (horizontal) Fasten the Resilient Sound Isolation Clip (RSIC-1) to the substrate with an approved fastener. Ensure the internal metal ferrell is tight to the substrate. Locate the first row of RSIC-1 clips within 3 inches from the floor and within 6 inches from the ceiling. Snap in the drywall furring channel (hat track) into the RSIC-1 clips (horizontal for walls). Place 1/8 min. shim on floor before installing the gypsum board. Install the gypsum board leaving a 1/4 min. gap around perimeter. Remove the shims after gypsum board is completely screwed to the drywall furring channel. Caulk around the entire perimeter of the gypsum board. Use fire rated sealant where required. Ceilings: Resilient Sound Isolation Clips (RSIC-1) shall be 48 inches (1219mm) on center maximum. Fasten the Resilient Sound Isolation Clip (RSIC-1) to the substrate with an approved fastener. Ensure the internal metal ferrell is tight to the substrate. Locate the first row of RSIC-1 clips within 8 inches of the wall at each end of a run. Snap in the drywall furring channel (hat track) into the RSIC-1 clips. Install the gypsum board leaving a 1/4 min. gap around the gypsum board. Caulk around entire perimeter of the gypsum board. Use fire rated sealant where required. General Information: Resilient Sound Isolation Clip (RSIC-1), furring channel (hat track) and gypsum board shall not carry heavy loads such as cabinets or book shelves Splice furring channel (hat track) with 6 inch overlap in mid span, secure with 18 ga. tie wire or with two framing screws (7/16 ) Seal all potential air leaks with non-hardening acoustical caulking to achieve best noise control results. Use fire rated sealant where required. Fire Test Information: Approved for use in over 150 different UL Fire Resistive Design Assemblies. Check our website for the latest updates of the fire testing approvals WWW.PAC-INTL.COM Check UL Fire Resistance Directory File # R16638 Check UL s web pages. www.ul.com/database Contact UL (877) UL HELPS

APPLICATION RECOMMENDATIONS FOR WALLS AND CEILINGS. CONCRETE OR CMU. INSTALLING RESILIENT SOUND ISOLATION CLIPS (RSIC-1) RSIC CLIPS AT 24 and 16 O.C. RSIC-1 clips at 24" x 48" o.c. 1 or 2 Layers of 5/8" Gypsum Board 7/8" Drywall Furring Channel RSIC-1 clips 24" x 48" o.c. Concrete or CMU 48 in. 48in. RSIC-1 clips at 16" x 48" o.c. 3 Layers of 5/8" Gypsum Board 7/8" Drywall Furring Channel RSIC-1 clips 16" x 48" o.c. Concrete or CMU 48in.

The RSIC-1 is the first and only product classified by UL for both fire and sound. Members of the International Code Council NO EXPRESS OR IMPLIED WARRANTIES WARRANTY DISCLAIMER AND LIABILITY LIMITATION LANGUAGE THERE IS NO WARRANTY, REPRESENTATION OR CONDITION OF ANY KIND; AND ANY WARRANTY, EXPRESS OR IMPLIED, IS EXCLUDED AND DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow limitations on implied warranties, so the above limitation may not apply to you. LIABILITY LIMITED TO RETURN OF PURCHASE PRICE IT IS AGREED THAT SELLER S LIABILITY AND PURCHASER S SOLE REMEDY, WHETHER IN CONTRACT, UNDER ANY WAR- RANTY, IN TORT (INCLUDING NEGLIGENCE), IN STRICT LIABILITY OR OTHERWISE, SHALL NOT EXCEED THE RETURN OF THE AMOUNT OF THE PURCHASE PRICE PAID BY PURCHASER, AND UNDER NO CIRCUMSTANCES SHALL SELLER BE LI- ABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, PERSONAL INJURY, PROPERTY DAMAGE, DAMAGE TO OR LOSS OF EQUIPMENT, LOST PROFITS OR REVENUE, COSTS OF RENTING REPLACEMENTS AND OTHER ADDITIONAL EXPENSES, EVEN IF SELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE PRICE STATED FOR THE EQUIPMENT IS A CONSIDERATION IN LIMITING SELLER S LIABILITY AND PURCHASER S REMEDY. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. SELLER NOT LIABLE FOR PURCHASER S NEGLIGENCE SELLER WILL NOT BE LIABLE FOR ANY DAMAGES, LOSSES OR EXPENSES AS A RESULT OF PURCHASER S NEGLIGENCE, WHETHER DEEMED ACTIVE OR PASSIVE AND WHETHER OR NOT ANY SUCH NEGLIGENCE IS THE SOLE CAUSE OF ANY SUCH DAMAGE, LOSS OR EXPENSE. MODEL FOR DEMONSTRATION PURPOSES ONLY THE MODEL OR SAMPLE SHOWN BY SELLER TO BUYER IS USED FOR DEMONSTRATION PURPOSES ONLY. THERE IS NO WARRANTY THAT THE GOODS AS DELIVERED SHALL CONFORM TO THE MODEL OR SAMPLE, AND CONFORMITY OF THE GOODS TO THE MODEL OR SAMPLE IS NOT PART OF THE BASIS OF THE BARGAIN BETWEEN SELLER AND BUYER. NO WARRANTY OR COMPLIANCE WITH SAFETY CODE OR REGULATION SELLER DOES NOT WARRANT THAT ANY OF THE GOODS SOLD WILL MEET OR COMPLY WITH THE REQUIREMENTS OF ANY SAFETY CODE, BUILDING OR DWELLING CODE, OR REGULATION OF ANY STATE, MUNICIPALITY OR OTHER JURIS- DICTION. NEVADA LAW APPLIES SELLER AND BUYER AGREE THAT ALL ASPECTS OF THIS TRANSACTION INCLUDING THE APPLICABLE STATUTE OF LIMI- TATIONS SHALL BE GOVERNED BY THE INTERNAL LAW OF THE STATE OR NEVADA, AND NOT THE LAWS OF CONFLICTS. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.