RSIC-1EXT04 SOUND ISOLATION CLIP RSIC-1EXT04 INSTALLATION GUIDE

Similar documents
RSIC-1. RSIC-1, the Low Cost, High Performance, Noise control Solution. RSIC-1 specifications:

RESILIENT SOUND ISOLATION CLIPS

Installation Guide and Safety Manual

PinkWood Ltd. Revised September 29, 2017

Installation Guide April 2017

REPORT HOLDER: KINETICS NOISE CONTROL 6300 IRELAN PLACE DUBLIN, OHIO EVALUATION SUBJECT: KINETICS NOISE CONTROL WAVE HANGER

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

SECTION GYPSUM BOARD

SECTION GYPSUM BOARD ASSEMBLIES

Container Installation Guide

Endotherme Mat ES-5A-12

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: PAC INTERNATIONAL, LLC

Temporary Construction Loads Over I-Joist Roofs And Floors

Insulated Fire-Rated Access Door Model(s): BIT/BIW/BIP

Container Installation Guide

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.

PS-31 (SUS304, 300 mm) PS-31 (SUS304, 1,000 mm)

Fire Barrier Duct Wrap 615+

Technical Data for. Headers. and Beams

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

Floor Insulation Underlayment Section Sound Control Matting

3M Fire Barrier Moldable Putty Pads MPP+ Product Data Sheet

FOR: CEMCO - California Expanded Metal Products Co. Sound Transmission Loss Test

WHY I SHOULD SPECIFY AND USE FAS TRACK 1000?

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: HOMASOTE COMPANY

Clarifying the Fenestration Energy Performance requirement in the Ontario Building Code Supplementary Standard SB12

Albi DriClad FIREPROOFING APPLICATION MANUAL & FIELD GUIDE. Albi Manufacturing Division of StanChem, Inc. 401 Berlin Street East Berlin, CT USA

Drag Chain Conveyor Installation and Operation Manual

Appendix D. -Weyerhaeuser Fire Rated Assembly Listings-

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

ENKASONIC FLOOR UNDERLAYMENT 9110

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

92831 TEL: (714) FAX:

AND ACCESSORIES FOR DRYWALL CONSTRUCTION

STEEL PIPE NIPPLES SEAMLESS Price Sheet PNS-9.16C Effective: September 5, 2016 Cancels Price Sheet PNS-10.15C of October 5, 2015

KS SERIES - VERTICAL INSTALLATION

This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated by these symbols.

Carbon Forged Steel Fittings

Free 17'x6' Chicken Run Plan. Designed for up to 11 chickens

I-STUD Shaftwall System

A new method for protecting construction joints and through-penetrations from fire, water, smoke and sound.

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Fig. 1 - Standard Clevis Hanger

Dura Rack Family Of Products. 237,000 sq. ft. manufacturing facility

RACK HAT / STRIP DOOR

Infinity Perimeter Trim

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS REPORT HOLDER: WORTHINGTON ARMSTRONG VENTURE (WAVE)

where high efficiency is the standard

Shaftwall & Stairwell Systems Fire protection & sound isolation for shafts & stairwells

Backer Box INSTALLATION

Se incluyen las instrucciones en español

HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction.

SECTION GYPSUM WALLBOARD SYSTEMS. A. Gypsum board at new wall partitions or where indicated on drawings. B. ASTM C442 - Gypsum Backing Board

The GlasRoc Shaftliner Type X advantage...

SHOWER & TUB/SHOWER INSTALLATION

Pittsburgh Corning ProVantage Glass Block Installation System Assembly Instructions

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN

RapidPort EZ Port Applier DIRECTIONS FOR USE (DFU)

SLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017]

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

3M Electrically Conductive Adhesive Transfer Tape 9707

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: ECORE INTERNATIONAL, INC.

Berliss Companies 644 Route 10 P.O. Box 45 Livingston, NJ Phone: (973) Fax: (973)

Gold Bond brand /NGC. High Strength LITETM. Family of Products

PIP STF05511 Fixed Industrial Stairs

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued October 1, Legacy report on the 1997 Uniform Building Code

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: CITADEL ARCHITECTURAL PRODUCTS, INC.

Suspension Systems for Acoustical Lay-in Ceilings Seismic Design Categories D, E & F

VHB Tapes. Design Guide for Sign Assembly. Proven worldwide. Now even more versatile for more sign applications, more surfaces.

SHAFTWALL C-H STUD FIRE RATING ENGINEERING CATALOG

Finestone Stucco System

3M Fast Tack Water Based Adhesive 1000NF

DRYWALL DOLLY 900 LB. CAPACITY

Design, Testing and Utilization of Welded-Wire Rack Decking

ATI Evaluation Service A Division of Architectural Testing Certification Services

3M Abrasive Systems Division. Sanding made simple.

GLASS WALL SPECIFICATIONS

Wabo Modular STM and D Series Large movement expansion joint system

Fire Protection Products

General Guidelines. Tools Required. Instructions for Part # SC500-AF. Safety

CI/SfB (35) Xy [ Between us, ideas become reality. ] September 2005 FLAT. DrywallGridSystem. Technical Guide CURVED

Shaftwall and Area Separation Wall Systems.

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

TOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations

Product Specifications MRI Trench Duct

PITTSBURGH CORNING ASSEMBLY INSTRUCTIONS. KWiK N EZ Rigid Track Silicone System for Thinline Series Glass Block

Z5028 E3/Ci80 Horizontal bracket Mounting instructions

Maximum thermal performance ISOLEREN INSULATED METAL PANELS INSTALLATION GUIDE

Tiny TIMBERS Limited Warranty Solid Wood Plank Flooring

DECKING INSTALLATION GUIDE

BROADCAST: M BLOCKS, PLUGS, PLANKS NEW PRODUCT LAUNCH Date: June 16, 2016 Issued by: George Yoshida, Ted Colwell

PHOTO 1: View from Inside the Structure. Note the Rotation of the WSP, Failure at the Lower Leading Edge and Deformation of the Top Plate

SIMEILINGS TORSION SPRING CEILING SYSTEM SPECIFICATION

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT:

REPORT HOLDER: STEEL STUD MANUFACTURERS ASSOCIATION (SSMA) 35 EAST WACKER DRIVE, SUITE 850 CHICAGO, ILLINOIS EVALUATION SUBJECT:

Owner s Manual Shelf Lip Accessory

A. Submit the following in addition to the standard requirements.

Installation Instructions

Stacker Parts List. For printer model: TG3 Series PN: (A)

GLASS WALL SPECIFICATIONS

Transcription:

RSIC-1EXT04 SOUND ISOLATION CLIP RSIC-1EXT04 INSTALLATION GUIDE PAC International, Inc. Tel: (866) 774-2100 Technical: (866) 649-2710 Web Site: www.pac-intl.com

Furring Channel: Minimum requirements: 25 gauge, hemmed edge detail required on all 25 gauge furring channel. Meets or exceeds SSMA min. requirements. Optional: 22 Gauge (no hemmed edge required with 22 gauge) Depth: 7/8 inch Width Bottom: 2-12 inch wide minimum. Width Top: 1-1/4 inch wide Splice drywall furring channel (hat track) with 6 inch overlap in mid span (between two clip) secure with 18 Ga tie wire, or two 7/16 framing screws. Resilient Sound Isolation Clip (RSIC-1 EXT04) Spacing: maximum 48 inches on center Maximum acoustical design load: 36 lbs Fasteners: 1-1/2 1 RSIC-1 EXT04 to wood: #8 x 1-1/2 inch minimum size coarse thread screw. (Recommended #12 or #10 x 2-1/2inch hex head) RSIC-1 EXT04 to Steel: # 8 x 1inch minimum size fine thread screw. (Recommended #12 or #10 x 1-5/8 inch hex head) DO NOT fasten Resilient Sound Isolation Clips (RSIC-1) to framing members with nails. Use only approved screws. 5-1/4 RSIC-1 EXT04 dimensions: RSIC-1 EXT04 clip 3 wide RSIC-1 EXT04 and Drywall Furring Channel 5-5/8 deep RSIC-1 EXT04 clip 1-1/4 deep 1-1/4 Average Labor Rates: RSIC-1 EXT04: 60 clips per man hour Drywall Furring Channel: 550LF per man hour Labor rates provided to PAC International, Inc by independent contracting firm 3

Ceilings: One and Two layer 5/8 gypsum Resilient Sound Isolation Clip (RSIC-1 EXT04) shall be 48 inches (1219mm) on center maximum. (Perpendicular to Joist/Truss) Fasten the Resilient Sound Isolation Clip (RSIC-1 EXT04) to the side of the structural members with approved fasteners Ensure the metal L bracket is tight to the framing member. Locate the first row RSIC-1 EXT04 clips is within 8 inches of the wall at each end of a run. Snap in the drywall furring channel (hat track) into the RSIC-1 clip at right angles (perpendicular or parallel) to the framing members. General Information: Resilient Sound Isolation Clip (RSIC-1 EXT04), Furring Channel (hat track) and Gypsum board shall not carry heavy loads such as cabinets or bookshelves Splice furring channel (hat track) with 6 inch overlap in mid span, secure with 18 Ga. Tie wire or with two framing screws (7/16 ) Seal all potential air leaks with non-hardening acoustical caulking to achieve best noise control results. Use fire rated sealant where required. Adjustable up to 4 Adjustable up to 4

RSIC-1EXT04 SOUND ISOLATION CLIP Members of the International Code Council WARRANTY DISCLAIMER AND LIABILITY LIMITATION LANGUAGE NO EXPRESS OR IMPLIED WARRANTIES THERE IS NO WARRANTY, REPRESENTATION OR CONDITION OF ANY KIND; AND ANY WARRANTY, EXPRESS OR IMPLIED, IS EXCLUDED AND DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow limitations on implied warranties, so the above limitation may not apply to you. LIABILITY LIMITED TO RETURN OF PURCHASE PRICE IT IS AGREED THAT SELLER S LIABILITY AND PURCHASER S SOLE REMEDY, WHETHER IN CONTRACT, UNDER ANY WARRANTY, IN TORT (INCLUDING NEGLIGENCE), IN STRICT LIABILITY OR OTHERWISE, SHALL NOT EXCEED THE RETURN OF THE AMOUNT OF THE PURCHASE PRICE PAID BY PURCHASER, AND UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, PERSONAL INJURY, PROPERTY DAMAGE, DAMAGE TO OR LOSS OF EQUIPMENT, LOST PROFITS OR REVENUE, COSTS OF RENTING REPLACEMENTS AND OTHER ADDITIONAL EXPENSES, EVEN IF SELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE PRICE STATED FOR THE EQUIPMENT IS A CONSIDERATION IN LIMITING SELLER S LIABILITY AND PURCHASER S REMEDY. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. SELLER NOT LIABLE FOR PURCHASER S NEGLIGENCE SELLER WILL NOT BE LIABLE FOR ANY DAMAGES, LOSSES OR EXPENSES AS A RESULT OF PURCHASER S NEGLIGENCE, WHETHER DEEMED ACTIVE OR PASSIVE AND WHETHER OR NOT ANY SUCH NEGLIGENCE IS THE SOLE CAUSE OF ANY SUCH DAMAGE, LOSS OR EXPENSE. MODEL FOR DEMONSTRATION PURPOSES ONLY THE MODEL OR SAMPLE SHOWN BY SELLER TO BUYER IS USED FOR DEMONSTRATION PURPOSES ONLY. THERE IS NO WARRANTY THAT THE GOODS AS DELIVERED SHALL CONFORM TO THE MODEL OR SAMPLE, AND CONFORMITY OF THE GOODS TO THE MODEL OR SAMPLE IS NOT PART OF THE BASIS OF THE BARGAIN BETWEEN SELLER AND BUYER. NO WARRANTY OR COMPLIANCE WITH SAFETY CODE OR REGULATION SELLER DOES NOT WARRANT THAT ANY OF THE GOODS SOLD WILL MEET OR COMPLY WITH THE REQUIREMENTS OF ANY SAFETY CODE, BUILDING OR DWELLING CODE, OR REGULATION OF ANY STATE, MUNICIPALITY OR OTHER JURISDICTION. NEVADA LAW APPLIES SELLER AND BUYER AGREE THAT ALL ASPECTS OF THIS TRANSACTION INCLUDING THE APPLICABLE STATUTE OF LIMITATIONS SHALL BE GOVERNED BY THE INTERNAL LAW OF THE STATE OR NEVADA, AND NOT THE LAWS OF CONFLICTS. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.