SECTION EXTERIOR GRILLS AND SCREENS

Similar documents
SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

Guideline Specifications

Corium Brick Rainscreen System Specifications

Page 1 of 5

by Rollfab Metal Products

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS


Specifications for FL-100 Soffit Panel

EVO ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION

1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels.

PROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS

PROJECT LOCATION SECTION TEXTURED METAL PLATE WALL PANELS

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System

SPECIFICATIONS: Architectural Aluminum Railings

SECTION MANUFACTURED ROOF EXPANSION JOINTS

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION METAL COMPOSITE MATERIAL WALL PANELS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

CENTRIA FORMABOND II Metal Composite Wall System

SECTION DECORATIVE METAL AND GLASS RAILING

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

VITRABOND Aluminum Composite Panel Façade System Specification Template

SL150 Guide Specification

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

SECTION EXPANSION CONTROL

VITRABOND Metal Composite Material Façade System Specification Template

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

CENTRIA EcoScreen Perforated Screen Wall Panels

Prestige Series Guide Specifications

SECTION GYPSUM BOARD ASSEMBLIES

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

TMS 152 / 152T / 152XT TECHNICAL MANUAL

TerraClad TM General Specifications

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

March 26, 2017 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

SECTION TURBINE VENTILATORS

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System

SECTION GUTTERS AND DOWNSPOUTS

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall

SECTION ALUMINUM COMPOSITE WALL PANEL SYSTEM

TMS 114 XT TECHNICAL MANUAL

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

Repair Maintenance Hangar Phase II August 2010

CENTRIA FORMABOND. Aluminum Composite Wall System

A. This Section includes automatic entrance door systems operating as follows: 1. Swinging operation.

WESTECK WINDOWS and DOORS

SECTION GLASS BALUSTRADE RAILING SYSTEMS

BEARING METAL STUD FRAMING

A. ASTM C190 - Test Method for Tensile Strength of Hydraulic Cement Mortars

PIPE AND TUBE RAILINGS

A. Pre-engineered, pre-finished extruded aluminum Pavilions.

Alply CLASSIC WALL Architectural Insulated Panel Wall System

SECTION GYPSUM WALLBOARD SYSTEMS. A. Gypsum board at new wall partitions or where indicated on drawings. B. ASTM C442 - Gypsum Backing Board

Aluminum Component Pipe Railings

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers)

SECTION SECTIONAL OVERHEAD DOORS

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove

SECTION ACOUSTICAL PANEL CEILINGS

SECTION ALUMINUM RAILINGS

SWING DOOR SPECIFICATION

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

SPECIFICATION SECTION PART 1 GENERAL

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders

Section PERMANENT GLASS FLOOD BARRIERS

ARMSTRONG SHALL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF THE USE OF ANY OF ITS GUIDE SPECIFICATIONS. SECTION PERIMETER TRANSITION SYSTEM

SECTION DIRECTORIES

Specification for larson by Alucoil PE Core Aluminum Composite Material (ACM)

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

TILE TILE

American Metal Specialties, Inc.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

SECTION CLIMBING WALLS

EDGEWATER, FLORIDA JUNE 14, 2010

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION METAL WALL PANELS

GUIDE SPECIFICATIONS CURA ADJUSTABLE REROOF FRAMING SYSTEMS SECTION REROOFING ADJUSTABLE FRAMING SYSTEM

A. Product Data: For each type of deck, accessory, and product indicated.

SECTION SECTIONAL OVERHEAD DOORS

WOOD FLOORING WOOD FLOORING

PRODUCT SPECIFICATION SERIES 9000 WINDOW WALL THERMALLY BROKEN ALUMINUM CASEMENT / AWNING / FIXED WINDOW

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

SECTION METAL BUILDING SYSTEMS

Section Sliding Aluminum Framed Glass Doors (2500 Model Specifications)

1.1 SECTION INCLUDES A. Insulated Metal and FRP Wall and Ceiling Panels and Related Accessories.

Architectural Specifications, Section Phenolic Lockers

Attachment A-Flagpole(s) Specifications

Transcription:

SECTION 10 82 13 PART 1 GENERAL PART 1 1 SUMMARY A. Section Includes: 1. Exterior perforated aluminum screen wall system with Ombrae TM Optical Tile imaging technology. 2. Accessories including attachments, clips, sub girts, shims, and fasteners 3. Factory applied coating system. ***Edit related Sections to those referenced in body of specification section.** B. Related Sections: 1. Section 04220 - Concrete Masonry Units 2. Section 05400 Cold Formed Metal Framing 3. Section 07600 - Flashing and Sheet Metal 4. Section 07900 Joint Sealants 5. Section 08520 Aluminum Windows 6. Section 08911 - Glazed Aluminum Curtain Wall PART 1 2 REFERENCES A. American Architectural Manufacturers Association (AAMA): 1. AAMA 2605 - Voluntary Specification Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels. B. ASTM International (ASTM): 1. ASTM B 209 Aluminum and AluminumAlloy Sheet and Plate. PART 1 3 SYSTEM DESCRIPTION A. Modular perforated aluminum alloy sheet screen wall system with Ombrae Optical Tile imaging technology. B. Mounting system, clips and fasteners. PART 1 4 DESIGN REQUIREMENTS A. Wall Panel Deflection: L/40. B. Thermal Movement: Design system to accommodate vertical and horizontal thermal movement of components without causing buckling, failure of joint seals, and undue stress on fasteners when subject to seasonal temperature cycling. Systems that accommodate movement with enlarged/slotted attachment holes not accepted. C. Tolerance of Substructure: Design system to accommodate up to 1/4 inch in 10 foot variation out of plane. Accommodate tolerances of building structural framing. PART 1 5 PERFORMANCE REQUIREMENTS A. Structural Performance: No permanent deformation at 150 percent of design pressure exceeding L/60 for frame and L/40 for material. 10 82 13-1 of 5

PART 1 6 SUBMITTALS A. Submit under provisions of Section 01330. B. Shop Drawings: Show thickness and dimensions of panels, panel profile, Ombrae Optical Tile layout, fastening and anchoring methods, details, and locations of joints. C. Product Data: Manufacturer s panel profiles, dimensions, characteristics and structural properties. D. Design and Performance Data: Fabricator s system including standard drawings, details, and design. E. Panel Samples: Minimum 8 inch by 8 inch in specified thickness, including attachment extrusions, clips, subgirts, fasteners, closures, and other panel accessories F. Color Samples: Panel material finished to specified color and finish. G. Fabricator Instructions: 1. Include installation instructions, technical bulletins, and other product data. 2. Include instructions for substrate requirements, special handling criteria, installation sequence, perimeter conditions, cleaning procedures, and conditions requiring special attention. H. Sample Warranty: Meet or exceed provisions specified by this Section. PART 1 7 QUALITY ASSURANCE A. Single Source Responsibility: 1. Provide design and fabrication of wall panel system under responsibility of fabricator including perforated screen wall panel with Ombae Optical Tiles, attachments, clips, girts, fasteners, and other accessories. PART 1 8 QUALIFICATIONS A. Fabricator: 1. Company specializing in designing, engineering, and fabricating work of this Section. 2. Approved by panel manufacturer as qualified to perform work of this Section. B. Installer: 1. Company specializing in installing work of this Section. 2. Trained and authorized by perforated screen wall panel system fabricator as qualified to perform work of this Section. PART 1 9 MOCKUP A. Provide under provisions of Section 01450. B. Construct mock-up, including outside corner condition showing complete system assembly including joint sealant. C. Construct size and type and locate as directed by Architect at owners cost. D. Incorporate accepted mock-up into Work. PART 1 10 PRE-INSTALLATION CONFERENCE A. Arrange, in accordance with Section 01312. B. Attendance: GC/CM, installer, Owner, Architect, manufacturer s representative, and those requested to attend. 10 82 13-2 of 5

C. Meeting Time: Minimum 2 weeks prior to prior to beginning work of this Section and work of related Sections affecting work of this Section. D. Location: Project Site. PART 1 11 DELIVERY, STORAGE, AND HANDLING A. Conform to provisions of Section 01651 and manufacturer's instructions. B. Deliver in manufacturers protective packaging with identifying labels intact. C. Store in well ventilated space under cover, off ground, protected from direct sunlight, weather, moisture, soiling, and marring of surface. 1. Protect panels from temperatures exceeding 120 degrees F. 2. Slope stored panels for positive drainage of water and condensation. D. Handle to prevent twisting, bending, and abrasion. Prevent contact with materials which may cause discoloration or staining. PART 1 12 PROJECT CONDITIONS A. Field Measurements: Verify actual conditions prior to fabrication and show on Shop Drawings. PART 1 13 COORDINATION ***Edit sections to include coordination and sequencing as needed for completion of work *** A. Conform to Section 01311 for coordination with work of other Sections. B. Field dimensions, Shop Drawings, and fabrication with critical path of construction Progress Schedule as necessary to meet lead time and avoid delays. C. Section 05400 for backing and support for work of this Section. PART 1 14 WARRANTY A. Conform to Warranty provisions specified Section 01778. B. Finish Coating System: Standard 5 year materials Warranty against fading, crazing, and chalking of coating system. C. Panel Manufacturer: Standard 2 year materials Warranty against defective materials. D. Panel System Fabricator: 2 year fabrication Warranty for conformance to design and performance and requirements. E. Installer: 2 year workmanship Warranty for water tightness. PART 2 PRODUCTS PART 2 1 FABRICATOR A. Perforated Screen Wall System Fabricator: 1. Keith Panel Systems, Tel (604) 987-4499 Fax (604) 987-4742, Email: mail@keithpanel.com. Basis of Design for performance and appearance. KPS Perforated Screen Wall with Ombrae. 10 82 13-3 of 5

2. No equals or alternates will be accepted. PART 2 2 ALUMINUM SCREEN WALL PANEL MATERIALS A. Aluminum Sheet: 3003 H14 aluminum alloy per ASTM-B209 B. Thickness: 2mm PART 2 3 ACCESSORIES A. Attachments, Clips, and Girts: As instructed by manufacturer. B. Pop Rivets: Stainless steel or aluminum as determined by fabricator to prevent galvanic action. C. Screw Fasteners: Type S, self drilling, self tapping framing screws, stainless steel with carbide head, an as instructed by manufacturer to suit application. D. Shims: As instructed by manufacturer. E. Isolation Accessories: Isolation tape, pads, or coatings as necessary to prevent galvanic action between dissimilar metals. PART 2 4 FABRICATION A. Shop fabricate wall panels in sizes and joint configurations to according to shop drawings. B. Form panel lines, breaks, and angles free from warp and buckle, and with no displacement of aluminum sheet. C. Custom perforate sheet with Ombrae Optical Tiles according to shop drawings. D. Form sections true to shape, accurate in size, square, and free from distortion or defects. PART 2 5 FINISHES A. Exposed Aluminum: PPG Duranar, PVDF, minimum 70 percent Kynar 500, or Hylar 5000 resin content, factory applied bakedon finish, conforming to AAMA 2605. B. Uncoated exposed metal not accepted. Touch up uncoated metal for smooth, finished appearance matching color and gloss level of adjacent finish. C. Field Touchup Paint: PPG Coraflon ADS, air-dry system, fluorocarbon resin coating matching color and texture of finish coating. D. Wall Panel Color: PPG Duranar [Color Name]. E. Sheen: 30 percent. PART 3 EXECUTION PART 3 1 EXAMINATION A. Verify conditions ready to receive work of this Section before beginning installation. B. Verify substrate framing members suitable for installation ready to receive wall panel system. 10 82 13-4 of 5

PART 3 2 PREPARATION A. Shim metal framed framing members and supports as necessary to provide level and plumb substrate for fastening panels. PART 3 3 INSTALLATION A. Install in accordance with manufacturer's instructions and provisions of Contract Documents. B. Permanently fasten and anchor composite wall panel system to structural framing system or glazing system using manufacturers anchors, clips, and girts. C. Install wall panel aligned, level, and plumb, within specified tolerances. D. Use concealed fasteners and clip attachments. E. Isolate aluminum from dissimilar metal, as required to prevent galvanic action. PART 3 4 TOLERANCES A. Maximum Offset From Alignment Between Adjacent Wall Panels: 1/8 inch. B. Maximum Variation from Horizontal and Vertical Plane: ½ inch in 20 foot, non-accumulative. PART 3 5 FIELD QUALITY CONTROL A. Manufacturer s Field Service: 1. Make periodic visits and final inspection by manufacturer s authorized product representative as necessary to verify conformance to manufacturer s instructions and Warranty provisions. 2. Promptly notify Architect of non-conforming work. PART 3 6 ADJUSTING A. Make adjustments to wall panel installations not conforming to specified tolerances. B. Field touch-up damaged finishes to match color and finish of factory applied panel finish. C. Replace work which cannot be repaired so that repairs are not discernable at distance of 10 foot. PART 3 7 CLEANING A. Dry-wipe panels as work progresses. B. Leave installation clean, free from residue and debris resulting from work of this Section. END OF SECTION 10 82 13-5 of 5