Sound Insulation for Glass and Panel

Similar documents
Important Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA

Important Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA

KINETICS NOISE CONTROL TEST REPORT #AT001067

KINETICS NOISE CONTROL TEST REPORT #AT001035

NYU Core: Post-EIS Façade Improvement Acoustical Assessment

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: THERMA-TRU CORPORATION

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: PAC INTERNATIONAL, LLC

This page was. intentionally. left blank

TL: Transmission Loss ASTM E-90

Enhancing Acoustic Performance through the use of Window Shade Fabric White Paper

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: THERMA-TRU DOORS. SERIES/MODEL: Slimline. TYPE: 8/0 Sliding Patio Door

LABORATORY MEASUREMENTS OF THE SOUND REDUCTION INDEX ROCKWOOL ABLATIVE COATED BATTS

Acoustics 08 Paris 3059

Acoustic Testing of CLT and Glulam Floor Assemblies Nordic Engineered Wood Report No. A August 2016 CONSTRUCTION

Office Soundproofing. Office Soundproofing & Soundproofing Solutions

slimlite Double Glazed Units BS EN 1279 Certificate Double Glazed Units

European Round Robin Test for sound insulation Measurements of lightweight partition.

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Edition October May (always refer to the latest manual as set out on

INNOVATIONS FOR LIVING

The effect of additional thermal lining on the acoustic performance of a wall

Evidence of Performance Joint sound reduction of filling material

Prediction of the acoustic performance of floor coverings on lightweight floors

movable walls Space Optimal Solutions

Optimizing Ceiling Systems and Lightweight Plenum Barriers

Evaluation VerteTek Coat of Silence

Design Standards Brief Section 13 Acoustics

Applied Noise Control. D. W. Herrin, Ph.D., P.E. University of Kentucky Department of Mechanical Engineering

June Residential Refurbishment Separating walls

Presented By: Jim O Neill. Acoustics

White Paper. A guide to the acoustic performance of Smarts Systems Products. Building Regulations Document E Resistance to the passage of sound

Analysis 4 Acoustical Analysis of Interior Partitions- Breadth

The uncertainty in sound insulation of an industrially prefabricated lightweight timber construction

A Measurement Technique for Evaluating Insertion Loss of Cavity Fillers

Kinetics Noise Control

ARCHITECTURAL AND STRUCTURAL NOISE CONTROL SOLUTIONS

Acoustic Design Criteria

NRC Publications Archive Archives des publications du CNRC

Testing Procedure: AS ISO

DETAILED ANALYSIS OF MEASUREMENT RESULTS OF FLANKING TRANSMISSION ACROSS A JUNCTION COM- POSED OF DOUBLE WALLS CARRIED OUT ON A HALF SCALED TEST BENCH

In order to solve the problems associated with sound, there. is a need to look at the acoustic component of the buildings. These

Guide for Sound Insulation in Wood Frame Construction

Achieving acoustical standards in the classroom Study of HVAC systems and classroom acoustics

Moduline. Acoustic Enclosure System. Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components

Wall and Floor/Ceiling Assemblies

Vinaflex Noise Reduction Materials Insulation Innovation

PROMATECT -H Timber Floor Protection Type 1

ABSORPTION PANELS FOR THE BEST POSSIBLE ACOUSTICS

Developing a component catalogue for determining airborne sound insulation as well as flanking sound insulation of curtain walling

IntelliPak Ton and IntelliPak II Ton Rooftops

Fabric detail available in any of these standard options. Timber finishes available in any of these standard species

INNOVATIVE AND SUSTAINABLE COATING SYSTEM: PRELIMINARY ACOUSTIC EVALUATION RESULTS

This classification report consists of five pages and may only be used or reproduced in its entirety.

INTERCOMPARISON OF LABORATORY MEASUREMENTS OF AIRBORNE SOUND INSULATION OF PARTITIONS. A. Farina (1), P. Fausti (2), R. Pompoli (2), F.

Frameless Glazing PLANET. Innovative design performance systems MONTAGE DESIGN. Frameless Glass. Uniclass L384:P314 EPIC C441:X342. CI/SfB 22.

TP LITE. Office Partitions. Technical guide

PIP INSA1000 Acoustic Insulation Systems Specification

APPLICATIONS HVAC Acoustics and Vibration

Movable Acoustic Walls for Flexible Space

Speech privacy in healthcare buildings: review of early studies and current procedures for analysis

DIVISION 13 - SPECIAL CONSTRUCTION SECTION ACOUSTICAL PANEL ENCLOSURE

URSA MINERAL WOOL URSA Acoustic Roll

Fire protection, soundproofing and thermal insulation

Trane Engineers Newsletter Live. Specifying Quality Sound Presenters: Dave Guckelberger, Brian Reynolds, Art Hallstrom

ARCHITECTURAL ACOUSTICAL WALL & CEILING PRODUCTS

MULTIPURPOSE ROOM INTERIOR NOISE CONTROL FOR OWNERS AND FACILITY MANAGERS CLARE ELIZABETH SEIP. B.S., Kansas State University, 2007 A REPORT

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

OFFICE. How to make the revolution happen. Turn efficiency up

DEKO MG. Preassembled Double Glazed Modules

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

STUDY OF SOUND INSULATION PROPERTIES OF CONCRETE HOLLOW BRICK WALL

TEST REPORT. Report Number : / Report Date : 27 / 07 / 2015

Analysis Joint sound insulation of filler materials

BLAST PERFORMANCE OF NON-CAPTURED STRUCTURALLY GLAZED INSULATED GLASS UNITS SAMUEL POND, P.E. + JAMES CASPER, S.E., P.E.

GIESSE OPEN SOURCE SYSTEM CASEMENT PROFILES SYSTEM FOR WINDOWS AND DOORS CASEMENT

-Letter - Tables 1 and 2 - Figure 1 - Exhibits 1 through 6

VALIDATION REPORT No

Effective Noise Barrier Design and Specification

Noise-Foil Acoustic Metal Panels Sound Absorption Systems for Industry & Commerce

N O I S E I N S U L A T I O N M A T E R I A L S

The Sound Insulation of Cavity Walls

ROXUL Blanket (and Batt) Insulation Section Master Guide Specification (AFB) Page 1 April 2015

3 Specification 3.1 Dimensions Lites of overall dimensions ( x ) inches / mm.

DEKO FG. Fully Glazed Partition - An Open Environment

RESILIENT SOUND ISOLATION CLIPS

Noise Control. Commercial, Industrial, and Environmental Products and Solutions.

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 492 AND ASTM E Rendered to REGUPOL AMERICA

POWER PRESSES. Vibration Control, Mounting and Levelling of: Power Presses APPLICATIONS. Presses come in various categories including:

The Optimization of a Wooden Floor Design Based on Validated Finite Element Models

1-3/4 Whisper Core Door Systems

Selecting partitions

Flooring and Acoustic Damping Sikafloor Marine

VIBRATION CONTROL FOR A 25 MW STEAM-TURBINE GENERATOR INSTALLATION NEAR ACADEMIC TEACHING AND RESEARCH LABORATORIES

CI/SfB. November Design Guide Concrete block masonry

CI/SfB V. Fellert Spray Applied Acoustic Plastering System. Highly absorbent plaster to improve sound surroundings

Reinventing construction

Acoustical characterization of the underground chapels of the new Holy Trinity church in the Fatima shrine, Portugal

Lexan* Thermoclear* Plus 9 wall Sheet

Transcription:

SEMINAR ON TESTING AND CERTIFICATION OF GREEN CONSTRUCTION MATERIALS Sound Insulation for Glass and Panel Ir Dr CHONG Fan

HIGHLIGHTS 1. Sound insulation of building construction 2. Sound insulation tests 3. Prediction models for sound insulation 4. Improvement of sound insulation

SOUND INSULATION OF BUILDING CONSTRUCTION What is sound insulation of building construction? It is a measure of the ratio of the sound energy striking the building component relative to the energy which is transmitted through the building component. Sound insulation / sound transmission loss (TL) is expressed in decibels as follows, TL = 10 log( W1 / W2) TL of a building component varies with frequency, usually increasing as the frequency increases

SOUND INSULATION OF BUILDING CONSTRUCTION Important to know the Sound Insulation Performance of Building elements To compare different constructions To calculate acoustic privacy between rooms To calculate noise levels from outdoor sources, such as road traffic To engineer optimum solutions to noise control problems

SOUND INSULATION OF BUILDING CONSTRUCTION Single-number rating of airborne sound insulation Sound Transmission Class (STC) -ASTM E90 Weighted sound reduction index (R w ) - BS EN ISO 140-3 R w and STC ratings are determined by laboratory test of a specimen. The higher the R w or STC rating, the better the sound insulation provided by a partition.

SOUND INSULATION TESTS Two adjacent reverberation rooms are arranged with an opening between them in which the test specimen is installed Omni-Power Sound Source Microphone Source Room Test partition Receiving Room

SOUND INSULATION TESTS Care is taken that the only significant sound transmission path between rooms is by way of the test specimen. An approximately diffuse sound field is produced in both rooms. Acoustic reflectors were installed in the reverberation chambers

SOUND INSULATION TESTS Sound incident on the test specimen causes it to vibrate and create a sound field in the second room, the receiving room. The space- and time-averaged sound pressure levels in the two rooms are determined. In addition, with the test specimen in place, the sound absorption in the receiving room is determined.

SOUND INSULATION TESTS Testing Procedure Background Measurement

SOUND INSULATION TESTS Testing Procedure Transmission Loss Measurement

SOUND INSULATION TESTS Testing Procedure Reverberation Time Measurement

SOUND INSULATION TESTS The sound pressure levels in the two rooms, the sound absorption in the receiving room and the area of the specimen are used to calculate sound transmission loss as shown in the following equation. For ASTM E90 and BS EN ISO 140-3: TL = L1 L2 + 10log( S / A) Because transmission loss is a function of frequency, measurements are made in a series of frequency bands.

SOUND INSULATION TESTS

SOUND INSULATION TESTS Sound reduction index, R (1/3 oct) Weighted sound reduction index Rw is 47dB 60 50 40 30 20 10 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 Sound reduction index, R, db Frequency, f, Hz Test Result Rw Standard Curve STC Standard Curve

SOUND INSULATION TESTS Transom (Vertical room to room)

SOUND INSULATION TESTS Transom (Vertical room to room)

SOUND INSULATION TESTS Mullion (Horizontal room to room)

SOUND INSULATION TESTS Mullion (Horizontal room to room)

PREDICTION MODELS FOR SOUND INSULATION Needs for Sound Insulation Prediction Laboratory measurements have been made for many different types of partitions. However, it is impractical to test every possible design To investigate the effects of changes to existing designs It is necessary to have reliable methods for predicting the sound transmission loss of typical building constructions.

PREDICTION MODELS FOR SOUND INSULATION Homogeneous Panels The most important property is the mass per unit area of the panel. The mass law gives a very simple prediction of the transmission loss TL TL = 20log(mf) However, for most practical building materials the static stiffness must be sufficiently high that coincidence between airborne and structure borne waves will occur within the frequency range of interest (50 5,000 Hz). The mass law is modified to include the change in transmission at the critical frequency and above 47 TL = c 20log( mf ) 10 log(2ηω / πω ) 47

PREDICTION MODELS FOR SOUND INSULATION Homogeneous Panels For most thin homogeneous materials used in building construction, above equation provides an excellent prediction of the transmission loss over most of the frequency range. However, one additional effect must be taken into account to obtain good accuracy at low frequencies. For typical test construction of 10 12 m 2, the radiation efficiency of forced waves must be taken into account for frequencies of less than 200Hz. Sewell gives the correction to the infinite area panel as ΔTL = 10 log[ln( ka 1 2 )] + 20 log[ 1 ( ω ω ) c 2 ]

PREDICTION MODELS FOR SOUND INSULATION Double Panels Many walls and floors are constructed of thin linings with an air space between, and these can, if correctly designed, give high sound transmission loss. For a partition consisting of two thin homogeneous panels, separated by an air gap containing an acoustically absorbing blanket, and with no interconnections between the two panels. Sharp has developed expressions for the transmission loss in 3 frequency ranges as follows: TL TL TL = 20 log[ f = TL 1 = TL 1 + TL + TL ( m 2 2 1 + m 2 )] 47 + 20 log( fd) 29 + 6 L f L f 0 L f < < > f f 1 0 f < f 1

PREDICTION MODELS FOR SOUND INSULATION Double Panels These expressions do not contain any parameters to describe the variation in performance due to different acoustic absorbers in the airspace and it is a practical problem of some interest to determine this effect. Fahy gives an alternative high frequency solution. TL = TL 8 L f > f 1 + TL2 +.6αd + 20 log( β / k) 1

PREDICTION MODELS FOR SOUND INSULATION Double Panels While some constructions can approach the ideal of double panels without interconnections, in practice most construction will have some type of solid or resilient connection between the panels. Sharp has developed relatively simple expressions for the transmission loss of double panels with either point or line interconnections. TL TL = = TL TL 1+ 2 1+ 2 + + 20 log( e 20 log( b f f c c ) + ) + 20 log[ m 1 20 log[ m 1 /( m 1 /( m 1 + m + m 2 2 )] 45 )] 18

INSUL SOUND INSULATION PREDICTION

INSUL SOUND INSULATION PREDICTION

INSUL SOUND INSULATION PREDICTION

INSUL SOUND INSULATION PREDICTION

INSUL SOUND INSULATION PREDICTION

INSUL SOUND INSULATION PREDICTION

INSUL SOUND INSULATION PREDICTION

TO ACHIEVE HIGH SOUND INSULATION Increase thickness of single panes (to increase mass). Use laminated glass to reduce the coincidence effect. Laminated glass can achieve STC rating 3 or more higher than monolithic glass of identical thickness. Use double-glass construction with at least 1/2-in-wide spacing between panes of different thickness (so panes will have different resonant frequencies). Ratio of thicknesses should be about 2:1. Replacing one pane of glass with equal thickness of laminated glass increases STC by 4.

TO ACHIEVE HIGH SOUND INSULATION Increase spacing between panes up to 6 in. TL increases by about 3 db per doubling of mean separation distance. Avoid using lightweight frames, and where especially high TL is required, use separate frames to reduce flanking of sound energy. Line interior perimeter of frame with sound-absorbing treatment (to improve TL by 2 to 5 db at high frequencies). Mount panes with soft neoprene edge gaskets, which provide higher TL than putty or caulking for the same thickness of glazing.

CONCLUSION Any prediction tools are not a substitute for actual test/measurement, Extensive comparisons with test data indicate that INSUL can reliably predict R w / STC values to within 3dB for most constructions. In practical, some building constructions are too complicated to predict. However, the sound insulation performance can be predicted with acceptable engineering accuracy over the frequency range 50-5,000 Hz using simple and readily available expressions.

END OF PRESENTATION Thank You! Q & A