HPCE-5 2. Realising the potential of Capillary Electrophoresis. Why is the HPCE-512 so much better?

Similar documents
Instructions for Capillary Electrophoresis Peptide Analysis Kit

Capillary Electrophoresis of Proteins

Optimization of cief to Resolve Challenging MAb Samples of Clinical Immunodiagnostic Relevance

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

IgG Purity/Heterogeneity and SDS-MW Assays with High- Speed Separation Method and High Throughput Tray Setup

LabChip GXII: Antibody Analysis

SYKAM Amino Acid Analyzer

Agilent CE and CE/MS Solutions FLEXIBILITY AND RELIABILITY TO AMPLIFY YOUR FINDINGS

Determination of Isoelectric Point (pi) By Whole-Column Detection cief

PA 800 plus Catalog. Systems/Software

CAPILLARY ELECTROPHORESIS SEPARATION OF SINGLE STRANDED DNA OLIGONUCLEOTIDES WITH AN UNCOATED BARE FUSED SILICA CAPILLARY. Corey J.

Electrophoresis and the Agilent Bioanalyzer. Advanced Biotechnology Lab I Florida Atlantic University January 23, 2008

Assay of IgG Purity and Heterogeneity using High-Resolution Sodium Dodecyl Sulfate Capillary Gel Electrophoresis

Explore the future. Automotive Test Systems Process & Environmental Medical Semiconductor Scientific

MOLEBIO LAB #3: Electrophoretic Separation of Proteins

Protein Techniques 1 APPENDIX TO CHAPTER 5

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

MBios 478: Mass Spectrometry Applications [Dr. Wyrick] Slide #1. Lecture 25: Mass Spectrometry Applications

Quantitative analysis of PCR fragments with the Agilent 2100 Bioanalyzer. Application Note. Odilo Mueller. Abstract

QUANTITATIVE DETERMINATION OF CYSTEINE AND CYSTINE IN PEPTIDES AND PROTEINS USING HYDRIODIC ACID

Sepax Technologies, Inc.

ELECTROPHORESIS a es

Analysis of biomolecules by SEC and Ion-Exchange UPLC

Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns

A universal chromatography method for aggregate analysis of monoclonal antibodies

The World Leader in SPR Technology. Jimmy Page, PhD, Biacore, Inc.

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

Purification: Step 1. Lecture 11 Protein and Peptide Chemistry. Cells: Break them open! Crude Extract

Purification: Step 1. Protein and Peptide Chemistry. Lecture 11. Big Problem: Crude extract is not the natural environment. Cells: Break them open!

Create a model to simulate the process by which a protein is produced, and how a mutation can impact a protein s function.

Capillary Electrophoresis: Principles and Practice

Structure formation and association of biomolecules. Prof. Dr. Martin Zacharias Lehrstuhl für Molekulardynamik (T38) Technische Universität München

Types of chromatography

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

ProSEC 300S. Protein Characterization columns

In the boxes below, draw the structure of the organic compounds formed by each reaction.

R R Innovation Way P/N SECKIT-7830 Newark, DE 19711, USA Tel: Fax: Website: Published in November 2013

TECHNICAL BULLETIN. in vitro Translation Labeling System. FluoroTect Green Lys. Instruc ons for Use of Product L5001. Revised 11/13 TB285

Capillary Electrophoresis in Quality Control PART II: CE-SDS: Method Development and Robustness

Notes to accompany the slidecast on theory of SDS PAGE and Western blotting

NPTEL VIDEO COURSE PROTEOMICS PROF. SANJEEVA SRIVASTAVA

PERFORMANCE MADE EASY REAL-TIME PCR

Capillary Electrophoresis Compendial Applications

A Complete Workflow Solution for Intact Monoclonal Antibody Characterization Using a New High-Performance Benchtop Quadrupole- Orbitrap LC-MS/MS

11 questions for a total of 120 points

Quantify protein stability with ΔG

Lifetime stability of size exclusion chromatography columns for protein aggregate analysis

electrophoresis tech Performance Comparison of the Experion Automated Electrophoresis System and SDS-PAGE for Protein Analysis

Chapter 10 Analytical Biotechnology and the Human Genome

nanodsf 2bind: Your service provider for biophysical characterization of proteins Precisely revealing protein folding and stability

Detecting Challenging Post Translational Modifications (PTMs) using CESI-MS

ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS

Method Development Considerations for Reversed-Phase Protein Separations

Roche Molecular Biochemicals Technical Note No. LC 10/2000

BÜCHI Labortechnik AG

Innovations To Meet Your Needs

Analysis and Purification of Polypeptides by Reversed-Phase HPLC

HiPer Real-Time PCR Teaching Kit

Characterize Fab and Fc Fragments by Cation-Exchange Chromatography

Quantum Dot applications in Fluorescence Imaging for Calibration and Molecular Imaging

Physical Stability of a Silica- Based Size Exclusion Column for Antibody Analysis

PROCEDURE FOR USE NICKEL NTA Magnetic Agarose Beads (5%)

UFFLC of the Proteome Ultra High Pressure and Ultra Fast Flow Liquid Chromatography: A New Approach To Proteomics

ExiProgen Protein Synthesis RNA/DNA Prep System Introducing the world's first automated protein synthesis and RNA/DNA purification system!

Case 7 A Storage Protein From Seeds of Brassica nigra is a Serine Protease Inhibitor Last modified 29 September 2005

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

Capillary Zone Electrophoresis in the Evaluation of Serum Protein Abnormalities

Absolutely RNA Microprep Kit

Non-Organic-Based Isolation of Mammalian microrna using Norgen s microrna Purification Kit

QImaging Camera Application Notes Multicolor Immunofluorescence Imaging

N-Glycan Profiling Analysis of a Monoclonal Antibody Using UHPLC/FLD/Q-TOF

E.Z.N.A. Yeast Plasmid Mini Kit. D preps D preps

MagSi Beads. Magnetic Silica Beads for Life Science and Biotechnology study

Sanger Sequencing: Troubleshooting Guide

Just one nucleotide! Exploring the effects of random single nucleotide mutations

LAB 6: Agarose Gel Electrophoresis of Restriction Digested Plasmid DNA

BIOLOGY LTF DIAGNOSTIC TEST DNA to PROTEIN & BIOTECHNOLOGY

Principles and Practice of Agarose Gel Electrophoresis

Proteomics. Proteomics is the study of all proteins within organism. Challenges

AGAROSE GEL ELECTROPHORESIS. Assiut University

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

Viscosizer & Archimedes, two new technologies from Malvern Instruments to characterize biomolecules and polymer particles

Code Description Molecular Weight Separation Range

Nucleic Acid Electrophoresis APPLICATION GUIDE

Rhinophase -AB, Zirconia-based Monoclonal Antibody Purification System

SMIBIO Case Study in Germany - Green Biorefineries in the Bavarian region of Straubing-Bogen (a case study in progress)

Cell Clone Selection Using the Agilent Bio-Monolith Protein A Column and LC/MS

ExiProgen Protein Synthesis RNA/DNA Prep System

determine optimum instrument settings for their own instruments and establish their own daily values.

Protein Quantitation using various Modes of High Performance Liquid Chromatography

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

HiPer Gel Extraction Teaching Kit (Column Based)

NRAS Codon 61 Mutation Analysis Reagents

Electrophoresis 101 Student Worksheet

Basics of Capillary Electrophoresis. Ronald E. Majors Hewlett-Packard Wilmington, DE

Peptide Mapping: A Quality by Design (QbD) Approach

2. Relay characteristics of proteins and protein electrophoresis / fractionation.

J. Sep. Sci. 2006, 29, F. Sang et al. 1275

Purification of (recombinant) proteins. Pekka Lappalainen, Institute of Biotechnology, University of Helsinki

Transcription:

HPCE-5 2 Realising the potential of Capillary Electrophoresis Why is the HPCE-512 so much better?

A Major Advance in Capillary Electrophoresis The HPCE-512 system based on multi-point detection overcomes the problems traditionally associated with conventional Capillary Electrophoresis (CE). Data of much higher quality is produced by the instrument compared to other CE systems in terms of quantification, resolution, sensitivity and repeatability. This significant advance in CE technology has been achieved by gathering much more data on the sample than competing systems, and then using proprietary signal processing algorithms to distinguish between signals relating to the analyte and those from background noise. With conventional CE systems data quality is often poor. Acceptable repeatability of analyses, even those of the same sample, can be difficult to achieve. Sensitivity is deemed inadequate without recourse to expensive, time-consuming labeling techniques that can adversely influence the nature of the analyte. The HPCE-512, however, is a label free system that both reduces the cost of analysis and solves the problems associated with conventional CE systems. 1 st protein crosses the detector Velocity of the proteins through the capillary is tracked across the multipixel detector The HPCE-512 images each analyte band across a 512 pixel photo diode array at ten to fifteen times per second so the transit of each band of molecules (in this case protein) is tracked in both time and distance. The resultant slope of the line tracking the particle s progress is dependent on characteristics of the molecules (e.g. molecular weight, charge / mass depending on the chosen mode of operation). The straightness of the line indicates the fidelity of the separation conditions. The tracks of all the various proteins lead back to a common injection point or vertex. Signals which are detected but which do not coincide with any of the vertex tracks (shown in red) may be identified and discarded as background noise. The result is an analysis of clearly defined peaks with very low background interference. This, in turn, leads to the realisation of high-resolution, quantifiable and repeatable analyses without the need to use labeling chemicals. Noise - thermal, electrical etc does not intercept the Vertex and is discarded

Better Data Quality Resolution, Repeatability & Quantification Accuracy The 512-pixel photo diode array detector used in the HPCE-512 system, allows very large datasets to be captured through each analysis. Powerful signal processing algorithms enable the background noise to be eliminated and individual components to be separated and quantified. Identification of each analyte peak can often be achieved from the molecular weight. arb 8m 7m 6m 5m 4m 1 2 4 6 7 10 11 13 17 1. O-Phospho-L-serine 2. L-Aspartic Acid 3. To be assigned 4. L-Glutamic Acid 5. L-Cystine 6. To be assigned 7. O-Phosphethanolamine 8. Cystathionine 9. L-Tyrosine 10. Glycine 11. Taurine 12. To be assigned 13. β-alanine & L-Alanine 14. L-Serine L-Sarcosine 15. L-α-Amino-n-butyric Acid, & D, L-β-Aminoisobutyric Acid & L- Asparagine 16. L-Threonine 17. L-Proline & Hydroxy-L-proline 18. L-Methionine 19. L-isdeucine & L-Leucine 20. L-Phenylalanine 21. L-Citrulline 19 3m 12 15 2m 1m 3 5 8 9 14 16 18 20 21 0 5 6 7 8 9 10 11 Time (mins) EVA processed data of amino acid standard solution (Sigma A6407) High Resolution Data Example - Ribonuclease B and its 5 glycoforms Peak 1 The image shows the Capillary Gel Electrophoresis of this glycoprotein with resolutions of <200Da (1 Mannose unit = 162Da), data quality that is comparable to some forms of Mass Spectroscopy. Peak 2 The powerful data processing algorithm resolves glycoproteins at resolutions under 200 Daltons

Example: E-Coli Cell Lysate Analysis with Conventional Capillary Electrophoresis (CE) The analysis of cell lysate samples is required in many biopharmaceutical areas:- - Expression of protein products - Purification of biological products such as Monoclonal Antibodies - Analysis of up and down-regulation of proteins in disease states The analysis of complex protein mixtures, such as cell lysates often require the use of fluorescent or chemical labels. The analysis of proteins with these expensive labels can cause changes in their characteristics leading to increased errors in the analysis process. Limitations inherent to single-point detection systems used in conventional CE instruments lead to poor resolution and repeatability (caused by the inability to adequately monitor capillary and buffer conditions). Single point CGE analysis of an E.coli cell lysate Analysis with High Performance Capillary Electrophoresis - HPCE-512 In the analysis shown below, E. coli lysate samples were analysed in standard running buffer containing ß-mercaptoethanol. After de-gassing, they were transferred to vials and loaded on the HPCE-512 carousel. The data were acquired in Capillary Gel Electrophoresis (CGE) mode. The increase in resolution is due to the multipixel technology used in deltadot s Label Free Intrinsic Imaging. Repeatability data show less than 1% RSD* in peak time (Molecular weight) and <5% RSD in peak area (quantification). Overlay of the processed data of nine consecutive E. coli lysate* runs all separated under the same conditions * Relative Standard Deviation over 9 runs

Self Diagnostics Continuous Monitoring of Capillary and Buffer Conditions ELECTROOSMOTIC / BULK FLOW +ve -ve DIFFUSE MOBILE LAYER COMPACT MOBILE LAYER STATIONARY LAYERS CGE ELECTROPHORETIC FLOW CZE ELECTROPHORETIC FLOW The Electroosmotic Flow issue The fused silica capillary contains surface silanol groups that become ionized in the presence of common electrophoretic media so it is negatively charged under most common ph conditions. This results in the formation of an electric double-layer which is immobile even under the application of an electric field and a mobile region with substantial cationic character. Beyond this compact layer is a diffuse layer that is a neutral bulk electrolyte solution. When a potential difference is applied to the capillary, the cations in the mobile layer migrate in the direction of the cathode. The ions are solvated in the electrolyte, thus the bulk electrolyte buffer is also mobilised in the direction of the cathode. This fluid flow is called electroosmotic flow (EOF) and if not monitored by multi-point detection and controlled by capillary conditioning will lead to poor data, especially with respect to repeatibility. The HPCE approach The multi-point detection allows space and distance based data sets to be generated in their signal processing algorithms as an Equiphase map. This can then be used to check each run to see if conditions in the capillary have affected the data. The EOF can be monitored for any specific separation by observing the behaviour of analyte bands or buffer components in the Equiphase map. This allows capillary conditioning and other parameters (such as ph, temperature, buffers etc.) to be optimised to generate significantly superior data in terms of repeatability, as well as resolution and quantification. Run 1 shows clear, well formed peaks Equiphase Map 1 Equiphase Map 11 Run 11 shows weak, indeterminate peaks The picture above would indicate that the product had degraded, but the Equiphase maps show that it is the separation conditions that have changed.

Application Areas RNA Specifications Physical Characteristics D 735 mm; W 680 mm, H 398 mm, Weight <70 kg PROTEIN 0.007 0.006 Light Chain ~25kDA 0.005 0.003 Sample handling: The system includes two carousels: - an input carousel and an output carousel. Analyses can be run either way. The number of tube positions is 24 per carousel. Sample injection can be electrokinetic or hydrodynamic. Temperature control is by Peltier cell cooling. 0.002 Heavy Chain ~50kDA 0.001 1.Non-glycosyated 2. Glycosylated 0 4000 6000 8000 10000 12000 14000 PEPTIDES Electrical Requirements: Maximum capillary voltage (bipolar) Filter wavelength range Voltage requirements Power requirements 28 kv (-14kV to +14kV) 200 300nm 85 to 264 VAC 50/60 Hz <750 Watts total VIRUS Operating Requirements: Temperature Humidity Optional Extras Sample Cooling 14 to 30 C 0 to 90% Non-condensing Between 10 C and 40 C DNA AMINO ACIDS CHEMICALS HORIBA UK Limited Sample Analysis and Application Support We are always willing to arrange for analysis of your samples to demonstrate the superior data produced by the HPCE-512. Please contact us for more information. 2 Dalston Gardens, Stanmore, Middlesex, HA7 1BQ United Kingdom Tel 020 8204 8142 Fax 020 8204 6142 E-Mail info-sci.uk@horiba.com www.horiba.com/uk/scientific withdeltadot Technology This document is not contractually binding under any circumstances - Printed in England - HORIBA UK Limited 2016