VISCOSITY, INHERENT (One Point)

Similar documents
INTERNATIONAL OIML R 69 RECOMMENDATION. Glass capillary viscometers for the measurement of kinematic viscosity - Verification method

SINTERED GLASSWARE Porosity Grades and their General Use

Analysis of Calcium Carbonate Tablets

Gravimetric Analysis: Determination of % Sulfur in Fertilizer

TITANIUM DIOXIDE. SYNONYMS Titania; CI Pigment white 6; CI (1975) No ; INS No. 171 DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Standard Test Procedures Manual

Viscosity Measurement Series

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

METHOD #: Approved for NPDES (Issued 1971) Oxygen, Dissolved (Modified Winkler, Full-Bottle Technique) ANALYTE: CAS # O Oxygen

Oxygen Demand, Chemical

Preparation of copper(ii) sulfate from copper(ii) nitrate

Recrystallization with a Single Solvent

Standard Test Methods for Softening Point of Resins Derived from Naval Stores by Ring-and-Ball Apparatus 1

3. Add 0.4 ml of. 7. Use a TenSette

to the presentation Teaching Thermodynamics: Chemical Potential from the Beginning Regina Rüffler, Georg Job

Chapter 8. Gravimetric Analysis

hydrometer set operating instructions All it takes for environmental research

H N 2. Decolorizing carbon O. O Acetanilide

2. Crystallization. A. Background

» Talc is a native, hydrous magnesium silicate, sometimes containing a small proportion of aluminum silicate.

Recrystallization II 23

Oxygen Demand, Chemical

Mon. Tues. Wed. Thurs. Fri. AM or PM B

Method to 500 µg/l CH 2 O Powder Pillows

Ti-Pure TITANIUM DIOXIDE. CONCENTRATED ACID SOLUBILITY OF TiO 2 METHOD: T WP

PROCESSED EUCHEUMA SEAWEED

USEPA 1,2 Bicinchoninate Method 3 Method 8506 (CuVer 1) and Method 8026 (CuVer 2) 0.04 to 5.00 mg/l Cu Powder Pillows or AccuVac Ampuls

Fines content. SCAN-CM 66:05 Accepted Mechanical and chemical pulps

Polyvidone Polyvinylpyrrolidone H 2 C H C N

CONSERVATION OF MATTER AND CHEMICAL PROPERTIES

Metal Finishing Products and Service META-MATE ZINCATE 40 "A CONCENTRATED LIQUID ZINCATE FORMULATION FOR THE PRETREATMENT OF ALUMINUM AND ITS ALLOYS"

2023 Reduction of D-(+)-camphor with lithium aluminium hydride to an isomeric mixture of (+)-borneol and ( )-isoborneol

Application Notes for COD Analysis DETERMINATION OF CHEMICAL OXYGEN DEMAND (COD) IN WATER AND WASTE WATER.

Calcium and Magnesium; Chlorophosphonazo Rapid Liquid Method Method to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Pour-Thru Cell

2 ADAPTER MOUNTING & APPLICATION

Technical Process Bulletin

DRS 261 RWANDA STANDARD. Herbal petroleum jelly Specification. First edition 2017-mm-dd. Reference number DRS 261: 2017

Partner: Cathy 22 March Separation and Qualitative Determination of Cations and Anions

Lab #2 Wafer Cleaning (RCA cleaning)

TESTING THE WATERS HOW GOOD IS THAT BOTTLED WATER AND HOW EFFECTIVE IS YOUR WATER FILTER

Nitrogen, Simplified TKN (s-tkn ) DOC

COLIFORM FILTERS. All filters listed on this page are white with black grids, 47 mm diameter, sterile.

Purification of cytoplasmic RNA from animal cells using the RNeasy Mini Kit

An Oxidation-Reduction Titration: The Reaction of Fe 2+ and Ce 4+

crystallization melting individual molecules crystal lattice

Experiment 13: Determination of Molecular Weight by Freezing Point Depression

Experiment. Molar Mass of an Unknown Sulfate Salt by Gravimetric Techniques 1

EAST AFRICAN STANDARD

á660ñ CONTAINERS GLASS

Scope and application: For water, wastewater, seawater, brine solutions, produced waters and hydraulic fracturing waters.

Experiment 3: The Chromatography of Organic Compounds

DETERMINATION of the EMPIRICAL FORMULA

DRAFT EAST AFRICAN STANDARD

Standard Methods for the Examination of Water and Wastewater

Experiment 2: The Chromatography of Organic Compounds

The Sense of Smell - Practical work

POLYBUTADIENE, LINEAR, CARBOXYL TERMINATED

Testing of the Zinc Coating Itself on Galvanized Rigid Conduit per UL6

CHEM 1215 LAB NOTES EXPT #2: PHYSICAL AND CHEMICAL CHANGES 1

Methods for determination of mercury in LP gas

Method 108C - Determination of Arsenic Content in Ore Samples From Nonferrous Smelters (Molybdenum Blue Photometric Procedure)

GRAVIMETRIC DETERMINATION OF SULFATE IN AN UNKNOWN SOLUTION

ISO 3093 INTERNATIONAL STANDARD

PORTABLE ph METER PRICE CODE NUMBER MODEL 100

The Crystal Forest Favorite Holiday Demonstrations

Pre- Lab Questions: Synthesis and Crystallization of Alum

Standard Operating Procedure Title: Operation and Calibration of Sievers 820 TOC Analyser

EDICT ± OF GOVERNMENT

Approved for NPDES (Editorial Revision 1978) Silica, Dissolved (Colorimetric)

QIAfilter Plasmid Midi Kit (Cat #: 12243)

DNA Extraction DNA Extraction (small scale) using CTAB method

Luster-On Products. Technical Data Sheet LUSTER-FOS 2900 CALCIUM MODIFIED, FINE GRAINED ZINC PHOSPHATE

Salinity in Seawater

PVA polymer slime. PVA polymer slime

For simultaneous purification of genomic DNA and total RNA from the same animal cells or tissues

DOWNSTREAM DEFENDER TESTING USING MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION PROTOCOL UTILIZING OK-110 FEED SAND

Standard Specification for Pigments for Integrally Colored Concrete 1

* Current monograph name valid until May 1, 2017 ** New monograph name valid as of May 1, 2012, mandatory as of May 1, 2017

(Applicable to identification of Salmonella in all foods.)

Forensics with TI-Nspire Technology

Episode 608: Latent heat

Preparation thin blood films and Giemsa staining

Safety Precautions. Hydrochloric acid, nitric acid and gold salts are corrosive.

Method 5.2 Syrup and remelt: Brix, NIR pol and purity

NOTE Comments are solicited especially on clauses ; ; 6.1.5; and highlighted in document.

Skills in Science. Lab equipment. (Always draw 2D) Drawings below are NOT to scale. Beaker - A general purpose container with a pouring lip.

Standard Test Method for Effects of Heat and Air on Asphaltic Materials (Thin-Film Oven Test) 1

SurTec 717 Alkaline Zinc/Nickel Electroplating Process (Electrolyte based on Sodium)

C.o.S.H.H. Regulations (M.S.D.S)

Working with Hazardous Chemicals

EXPERIMENT 3: Identification of a Substance by Physical Properties

Laboratory 2 Hydrometer Analysis Atterberg Limits Sand Equivalent Test

Standard Specification for Chemical Admixtures for Concrete 1

TOTAL SULPHITE (SO 2 )

SILICA, CRYSTALLINE in coal mine dust, by IR 7603

GEL Hydrogeology (Groundwater) LAB 2: POROSITY & HYDRAULIC CONDUCTIVITY - Porosity Segment - Grade: /25

O 3, SIO 2. O, CAO, Al 2 AND MG IN ANT-HILL SOIL SAMPLES WITHIN ABRAKA TOWN IN NIGERIA

Method 6.1 Boiling house products: Brix, pol and purity

Transcription:

VISCO.02-1 VISCOSITY, INHERENT (One Point) PRINCIPLE SCOPE A weighed starch sample is dispersed in sodium hydroxide solution using a standard technique. Relative viscosity of the sample dispersion is determined by measuring the efflux times of the dispersion and of the solvent with a capillary viscometer. The inherent viscosity is calculated as the quotient: natural logarithm of relative viscosity divided by concentration. This method is applicable to unmodified, acid-modified and oxidized starches. SPECIAL APPARATUS 1. Viscometer: Use a Cannon-Ubbelohde viscometer, size 75, Catalog No. CUBU (Cannon Instrument Company, P. O. Box 16, State College, PA 16801). For convenience, the viscometer should be equipped with a Cannon Instrument Company Catalog No. N 120 NEOPRENE rubber holder. New viscometers should be scrupulously cleaned and dried before using. Fill the viscometer with chromic acid cleaning solution and let stand two hours at room temperature. Drain and rinse with a large volume of purified water to insure complete removal of acid. Attach viscometer to a vacuum source by means of rubber tubing, and draw clean air through unit until dry (10 mins. usually sufficient). 2. Constant Temperature Bath: A stirred water bath operating at a temperature of 25 C ± 0.1 C is necessary. It should be equipped to hold the special beaker used for sample preparation, and the viscometer. 3. Stirring Assembly: A constant-speed (shaft speed 750 rpm) motor equipped 5 with a self-centering chuck and a hoop-type stirrer attached to a 16 -in. 12-in. shaft is recommended. A resistance- or governor-controlled motor Analytical Methods of the Member Companies of the Corn Refiners Association, Inc.

VISCO.02-2 REAGENTS may be used alternatively. A 2-in. diameter, hoop-type propeller, Arthur H. Thomas Company, Catalog No. 9240-U, should be attached to the shaft. 4. Beaker: 400 ml tall-form beaker (e.g., Corning Catalog No. 1100, or Kimble Catalog Nos. 14020 or 14050) 5. Timer: A stopwatch or electric timer with a precision and accuracy of ± 0.1 sec. over a range of 10 mins. is essential. 6. Funnel: Buchner, 6.0 cm, coarse porosity fritted disc (e.g., Corning Catalog No. 36060-150C) 1. Sodium Hydroxide Solution: Carbonate-free a. Stock Solution, 50%: Cautiously add 1 L of purified water to 1000 g of sodium hydroxide pellets and stir until solution is complete. Allow to stand in a rubber-stoppered, borosilicate glass bottle until supernatant solution is free of carbonate haze (about 10 days), or filter through glass wool after the solution has cooled to room temperature. Reagent grade 50% sodium hydroxide solution may be purchased and used alternatively. b. Sodium Hydroxide Solution, 2.00 M: Standard. Dilute appropriate volume of stock solution with freshly-boiled purified water. Standardize with potassium acid phthalate using phenolphthalein indicator. By addition of stock solution or water, adjust concentration 2.00 M ± 0.02 M. c. Sodium Hydroxide Solution, 1.00 M: Standard. Transfer by pipet 100.0 ml of 2.00 M sodium hydroxide to a 200 ml volumetric flask. Dilute to volume with freshly-boiled purified water. Prepare fresh as

VISCO.02-3 SAFETY needed and whenever new 2.00 M standard solution is prepared for sample dispersion. Person(s) performing this method should wear appropriate protective equipment. Glassware should be carefully inspected for defects before use. Analysts should also review the Manufacturer s Safety Data Sheets (MSDS) for all of the chemicals required; however this review is not a substitute for adequate laboratory safety training. PROCEDURE If necessary, grind sample completely through a laboratory cutting mill to 20 mesh or finer. Determine dry substance by a standard procedure. Weigh a starch sample containing 1.000 g of dry substance and transfer quantitatively to the 400 ml tall-form beaker. Add 100.0 ml of purified water at 25 C, and fix beaker in constant temperature bath so that bath liquid will be above starch solution level after the addition of sodium hydroxide solution. Lower stirring assembly and fix in position so that hoop-type propeller is centrally located about 1/8 above beaker bottom. Start stirring motor and continue stirring until starch is dispersed (2 mins. stirring is usually adequate). Continue stirring and add, by pipet, 100.0 ml of 2.00 M standard sodium hydroxide solution at 25 C. During addition hold pipet against the inside of beaker so that standard sodium hydroxide solution is dispensed at a relatively slow rate; continue stirring for 30 mins. after addition is complete (Note 1). Remove stirring assembly and cover beaker with a watch glass to prevent evaporation. Filter by gravity through a 6.0- cm coarse porosity fritted glass funnel. Attach a short length of rubber tubing to the upper capillary of the clean and dry Ubberlohde viscometer. With the aid of the special rubber holder, fix the viscometer in a vertical position in the constant temperature bath so that the bath liquid is above the meniscus bulb. Transfer approximately 10 ml of the filtered starch solution to the charge bulb. Cover vent with finger, apply suction to rubber tubing attached to upper capillary, and draw starch solution into meniscus bulb (Note 2). Remove suction and finger and allow solution to drain through meniscus and efflux bulbs. Repeat operation of drawing solution into meniscus bulb and allowing to drain from meniscus and efflux bulbs.

VISCO.02-4 Again cover vent with finger and apply suction to draw solution into meniscus bulb. Remove suction and finger, allow solution to flow from meniscus and efflux bulbs, and determine accurately (within 0.1 sec.) the time (t) required for the solution meniscus to flow from the upper timing mark to the lower timing mark. Repeat this operation to obtain a series of three readings. Calculate the mean of these values (Note 3). Drain starch solution from the viscometer and rinse with purified water. Rinse with 1.00 M sodium hydroxide solution and again with a large volume of purified water, and dry. If evidence or doubt suggests that the viscometer may not be clean at this point, fill with cleaning solution (chromic acid or equivalent and let stand 2 hrs. at room temperature. Drain cleaning solution, rinse pipet with a large volume of purified water, and dry. Position viscometer in constant temperature bath as before, and transfer approximately 10 ml of 1.00 M sodium hydroxide solution into the charge bulb. Draw solution into meniscus bulb and determine flow time (solvent efflux time t o ) by procedure outlined in preceding paragraphs. CALCULATION The procedure provides efflux times for the solvent (t o ) and starch solution (t) at a dry substance concentration of 0.500 g/100 ml. Calculate relative viscosity (0 rel ): 0 rel = t/t o Inherent viscosity is defined as the natural logarithm of the relative viscosity divided by the concentration. Then, Inherent Viscosity (η ) i dl/g = 1n ( η ) 2.303 log ( η ) c rel = 0.5 rel

VISCO.02-5 NOTES AND PRECAUTIONS 1. At this point, the starch dispersion should appear uniform and free of lumps. The presence of incompletely dispersed starch lumps is a valid reason for rejecting a determination. 2. Differences in construction of pipets may cause some trouble by allowing bubbles to rise in the capillary when suction is applied, particularly when the arm rising from the base of the capillary is fastened close to the top of the bulb below the capillary. To prevent bubble entrapment, it is advisable to such some of the sample partially up the pressure adjustment arm before the dispersion is raised in the main capillary. 3. The viscosity of the starch dispersion decreases slightly during this period. The rate of decrease, however, appears to be uniform and the mean of three successive readings is a reproducible result. METHOD HISTORY Corn Starch (Unmodified), Viscosity, Inherent (One Point) (B-61), Date of Acceptance 5-20-1963, Revised 4-02-2003.