Timber in Bushfire Prone Areas

Similar documents
Building with Timber in Bushfire-prone Areas

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

Steel Floor Framing Solutions

2003 International Residential Building Code

A GUIDE TO WINDOW AND DOOR SELECTION

AS Residential timber-framed construction Part 2: Non-Cyclonic Areas

WOOD USE IN NONCOMBUSTIBLE BUILDINGS

ISO Types 1-6: Construction Code Descriptions

Administrative Changes

Building Design Data

CB04. Outback House. Case Study. Creative Spaces Australia. by Casey Brown Architecture

N1 to N3. DuraGalPlus Domestic Construction Manual. Volume 2: DuraGalPlus RHS as lintels (garage beams, window heads)

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

INTERIOR FINISHES CHAPTER 8

PRESCRIPTIVE COMPLIANCE METHOD

Building Codes and Ordinances ARC 227

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

CABONNE COUNCIL DEVELOPMENT CONTROL PLAN NO. 15 RELOCATABLE AND TRANSPORTABLE HOMES

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

GIB EzyBrace Help. Copyright 8/16 by Winstone Wallboards Ltd. All Rights Reserved.

Building Code requirements for house insulation

Refusal of a code compliance certificate for a building with a brick veneer and monolithic cladding system at 47 San Bernadino Drive, Henderson

EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire

For New Zealand Building Code Clause B2 Durability

Acoustic Design Criteria

Boulder City NV Prepared by (Print Name) Signature Date

The following are details of the code requirements of the 2015 International Residential Code for single-story decks.

Inspection details. Subfloor. Subfloor. Before You Buy property inspection

The great Aussie shed deserves great Australian insulation

CITY OF FRUITLAND DIVISION OF PLAN REVIEW & PERMITTING DECK GUIDE. This design guide assumes all lumber to be pressure-treated Southern Pine.

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

INTERIOR FINISHES CHAPTER 8

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

Determination regarding heart macrocarpa posts and decking to a house at 51 Wastney Terrace, Nelson

Certificate number: CM40087 Rev3

SOL UTIONS LIVING SOLUTIONS LIVING SOLUTIONS

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

Fully framed glass panels

11 FLAT ROOF CONSTRUCTION

Applying the Building Code During Design

Timber-framed Systems for External Noise

N1 to N3. DuraGalPlus Domestic Construction Manual. Volume 3: DuraGalPlus RHS as floor beams (bearers)

UNIFIED FACILITIES GUIDE SPECIFICATIONS ************************************************************************** SECTION TABLE OF CONTENTS

ASSESSMENT OF AFS STRUCTURAL WALL SYSTEM FOR CBPA NSW, FEBRUARY 2008

How to fill in your Timber Frame Order Form

FACT SHEET #2 DECK INFORMATION

DURAGROOVE TM FACADE SYSTEM

BUILDER USER GUIDE FOR CONSTRUCTION OF TIMBER-FRAMED HOUSING IN WA

Brick Veneer Walls. Insulation

INSPECT DIRECT. Web Page: THIS REPORT IS VALID FOR (6) MONTHS FROM THE DATE OF MOST RECENT INSPECTION.

Carpenter Level 2 Rev. September 2017

A-One Polar Ltd. Bhulta,Rupgonj,Narayangonj. ( , ) 27th April 2014

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition

TECHNICAL BULLETIN TB136

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

Australian Standard. Design and installation of sheet roof and wall cladding. Part 3: Plastic AS AS

Deck, balcony and window safety A guideline for the use, inspection and maintenance of decks, balconies and windows

FIRE AND SMOKE PROTECTION FEATURES

Technical Notes 43G - Brick Passive Solar Heating Systems - Part 7 - Details and Construction [Mar./Apr. 1981] (Reissued Sept.

INTERIOR FINISHES CHAPTER 8

Typical Finished Basement Details

Roof Systems. Span Tables & Thermal Ratings. Custom Roof Panel

One and Two Family Additions

HOT SPRINGS FIRE DEPARTMENT EVALUATION OF DOWNTOWN LEGACY STRUCTURES Savoy Hotel Thompson Building Dugan Stewart Building May 16, 2012

Is Your Envelope Effective? BCBEC Luncheon January 29, 2009

CONTENTS. Using Advanced CAD to Create 2D and 3D Objects in Chief Architect 1. Introduction..2

Thermablok Aerogel Insulation Blanket Thermablok Aerogel Blanket

Specialists in Acoustic Flooring and House to Flat Conversions

ABA Fashions Ltd. Plot #9, Block F, Tongi, Gazipur-1710 ( N, E) 08 MARCH 2014

A HOMEOWNER S GUIDE TO ACCESSORY DWELLING UNITS

GUIDANCE DOCUMENT IGNITION RESISTANT EAVE CONSTRUCTION

A. SYSTEM DETAILS A.1 Product Range

Insulwhite. Insulation WHITE-FACED THERMO REFLECTIVE INSULATION

Subject: Lucretia Mott School No. 3 Rehabilitation. Figure 1 Figure 2 Figure 3

GTEK TM SOUND GTEK TM IMPACT

APPROVED. Acceptable to the code official for compliance with the provisions of the applicable Code or referenced Standard.

TECHNICAL SPECIFICATIONS & PROFILES PIR INSULATED EXTERNAL WALL PANEL TECHNICAL GUIDE TO CONQUEROR TM PIR INSULATED EXTERNAL WALL PANEL

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Thermablok Aerogel Isolation Strips Thermablok Aerogel Isolation Strips

Stage 6 & 7 Design Guidelines

Houses and Low Rise Multi-Residential External Walls PowerPanel XL. Design and Installation Guide

External Applications

RAPID STRUCTURAL ASSESSMENT REPORT

CANNING WAREHOUSE CANNERY DISTRICT BOZEMAN, MT

C H A P T E R 3. Completing the Residential Analysis Worksheet STEP 1: WINDOWS AND OTHER GLASS AREAS

Acoustic Cradle Levelling System

Guarding to openable windows with low cill heights

The Passive Fire Protection Handbook. Chapter 3: Structural Steel

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

Loxo 50mm AAC External Wall Panel System

Basic Information for Obtaining Permits, Submitting Plans, Scheduling Inspections, etc.

Material Report - [Trade Contractors] for plan: [E:\SoftPlan14\Projects\Sample Drawings.spf\2-Storey sqft.spf] Page 1 of 5

Plywood in modern. Australian architectural design

Safety barrier to a deck located adjacent to a retaining wall at Oraka Beach Road, Mahia

2012 IRC Sections R303 R310 Building Planning II

Stage 10 Design & Building Guidelines

WALL CEILING FACADE ACCESSORIES ACCESS PANELS CONTACT CLICK TO START

Transcription:

In many parts of Australia, the construction of new buildings and additions to existing buildings will be assessed as being in a Bushfire-prone Area. The relevant Australian Standard AS 959 provides six different Bushfire Attack Levels for proposed construction: BAL LOW BAL 9 BAL.5 5 BAL 0 BAL 9 6 BAL FZ (Flame Zone) Each level is based on the assessed threat dependant on the relevant Fire Danger Index, the surrounding type of vegetation (e.g. forest, woodland, shrubland etc), the distance from the site to the vegetation and the effective slope under the vegetation. As the assessed threat increases, so do the restrictions on the building materials that may be used. Where there are restrictions on the building materials, timber is permitted in many applications as the tables on pages through 6 Simplified Bushfire Standard Complying Timber Construction in NSW show.

The type of timbers that are allowed are dependent on the Bushfire Attack Level of the site. These timber can be summarised as BAL.5 and 9 General Timber Timber with density of 750 kg/m or greater, are timbers density at percent moisture content. Suitable timbers are listed in AS 959 Table E. Joinery Timber (window and doors only) Timber with density of 650 kg/m or greater, are timbers density at percent moisture content. Suitable timbers are listed in AS 959 Table E. BAL9 Bushfire resisting timber Can be timber with an inherent resistance to fire or fire retardant treated. The following seven timber species have been tested and found to meet the required parameters without having to be subjected to fire retardant treatment: Blackbutt Merbau Red Ironbark River Red Gum Silvertop Ash Spotted Gum Turpentine It should be noted that AS 959 does not replace any other standards which might set out minimum requirements for construction in a particular area but rather AS 959 sets out requirements which are dependent upon the degree of assessed threat posed by the Bushfire Attack Level (BAL) and which are additional to the requirements of those other standards. Further Information The external use of building materials in houses built in declared bushfire prone areas is controlled under the Code of Australia (BCA) Parts P.. and.7.. Before the BCA requirements apply, the local authority must declare the area, in which a house is to be built, to be a bushfire-prone area. Compliance with Australian Standard AS 959 Construction of s in Bushfire Prone Areas is deemed to satisfy the BCA requirements for Class s along with the NSW Rural Fire Services Planning for Bush Fire Protection 006.

Simplified Bushfire Standard Complying Timber Construction in NSW In NSW building regulations vary from the requirements in the Acceptable Construction Manual within the Code of Australia (BCA) which is AS 959 Construction of s in Bushfire-prone Areas standard. The table below incorporates the requirements of both AS 959 Construction of s in Bushfire-prone Areas 009, as well as Planning for Bushfire Protection Addendum: Appendix, NSW Rural Fire Service Planning for Bush Fire Protection. Although every effort was taken to reflect regulations of AS 959 Construction of s in Bushfire-prone Areas standard it is recommended this information sheet is used in conjunction with AS 959, especially where in doubt. Stairs/Decks/Ramps Subfloor Space BAL.5 and BAL 9 BAL 9 BAL 0 BAL FZ Wall enclosing subfloor space Less than 00mm from the ground or an external horizontal surface use timber framing provided such as fibre cement, bushfire-resisting timber or timber with density of 750 kg/m or greater. 00 mm or more above the ground there are no construction requirement any timber can be used or bushfire-resisting timber non-combustible clad, i.e. masonry or min 9 mm fibre cement NSW building regulations do not recognise deemedto-satisfy construction solution within this BAL. designs will require an alternative solution Subfloor supports (posts, stumps, columns, stair stringers etc) Bushfire-resisting timber Metal Deck/ramp bearers and joists Bushfire-resisting timber Metal, concrete or brick Decking and stair treads Bushfire-resisting timber Tiled or concrete decks Balustrades and Handrails Less than 5 mm from any glazing or any combustible wall handrails and balustrades shall made from non combustible material or bushfire-resisting timber 5 mm or more from the building handrails and balustrades have no requirement any timber can be used Less than 5 mm from any glazing or any combustible wall handrails and balustrades shall made from

Elevated Floors/Subfloors Subfloor Space BAL.5 and BAL 9 BAL 9 BAL 0 BAL FZ Wall enclosing subfloor space Less than 00mm from the ground or an external horizontal surface use timber framing provided such as fibre cement, bushfire-resisting timbers or timber with density of 750 kg/m or greater. 00 mm or more above the ground there are no construction requirement any timber can be used or bushfire-resisting timber non-combustible clad, i.e. masonry or min 9 mm fibre cement NSW building regulations do not recognise deemedto-satisfy construction solution within this BAL. designs will require an alternative solution Subfloor supports (posts, stumps, columns etc) Bushfire-resisting timber Brick, steel or concrete stumps Bearers and joists Less than 00 mm above the ground use Bushfire-resisting timbers or line the underside of the floor framing with fibre cement or sheet metal (roofing) Any timber provided the underside of the lowest joist or bearer is protected with a 00 mm or more above the ground there are no construction requirement any timber can be used such as a metal roof sheet or fibre-cement sheeting Flooring Less than 00 mm from the ground provided the underside is lined with sarking or mineral wool or Bushfire-resisting timbers Any timber provided the underside of the lowest joist 00 mm or more above the ground there are no construction or bearer is protected with a requirement any timber can be used such as a metal roof sheet or fibre-cement sheeting

5 Walls BAL.5 and BAL 9 BAL 9 BAL 0 BAL FZ External wall surface Less than 00mm above the ground or an external horizontal surface, the cladding is to be timber with density of 750 kg/m or greater, bushfireresisting timbers or with non- combustible material 00 mm or more above the ground or an external horizontal surface there are no construction requirement: any timber can be used Bushfire-resisting timber and sarking required between cladding and framework Non-combustible clad, i.e. masonry or min 9 mm fibre cement NSW building regulations do not recognise deemedto-satisfy construction solution within this BAL. designs will require an alternative solution External wall framing Internal wall surface Internal wall framing External Mouldings/Internal Timbers BAL.5 and BAL 9 BAL 9 BAL 0 BAL FZ Internal wall framing Internal Timber (Doors, joinery, wall lining, ceiling linings, staircases, flooring over concrete slab etc) NSW building regulations do not recognise deemed-to-satisfy construction solution within this BAL. designs will require an alternative solution Roof Framing BAL.5 and BAL 9 BAL 9 BAL 0 BAL FZ Roof framing under compliant noncombustible roof covering 5 NSW building regulations do not recognise deemed-to-satisfy construction solution within this BAL. designs will require an alternative solution

6 Framing for Roofed Structures like Verandas, Garages, Carports BAL.5 and BAL 9 BAL 9 BAL 0 BAL FZ Where attached structure separated from the building by a fire rated FRL 60/60/60 wall that extends to the underside of a noncombustible roof covering 5 Where the roof of an attached structure is separated from the roof space of the main building by a masonry veneer wall, 90 mm thick NSW building regulations do not recognise deemed-to-satisfy construction solution within this BAL. designs will require an alternative solution NOTES An external horizontal surface or a ledge includes decks, carport roofs, awnings and similar elements or fittings having an angle less than 8 degrees to the horizontal and extending more than 0 mm in width from the wall or window or door. Bushfire-resisting timbers include Blackbutt, Merbau (Kwila) and Red Ironbark, River Red Gum, Spotted Gum, Silver top Ash and Turpentine. Timber with density of 750 kg/m or greater, are timbers density at percent moisture content. Suitable timbers are listed in AS959 Table E. Consideration such durability, strength and appearance need to be considered in addition to bushfire requirements. These issues are not dealt in this guide. 5 Complying roof systems include conventional non combustible roof and materials (tile, metal sheet) ensuring any gaps over mm are protected by ember guards. For further detail on sealants, skylights, etc refer to AS 959. 6 Wood Solutions Guide 0: with Timber in Bushfire-prone Areas is available for free on www.woodsolutions.com.au Disclaimer: Whilst every effort has been made to ensure that this publication is in accordance with current information, it is not intended as an exhaustive statement of all relevant data. All comments in this information sheet are written with timber framed construction in mind and may exclude other forms of construction. In addition, successful design and construction depends upon numerous factors outside the scope of this publication. The authors and publishers accept no responsibility for errors in, or omissions from this publication, nor for specifications or work done or omitted in reliance on this publication.