Flow Meter Calibration

Similar documents
EXPERIMENTAL AERODYNAMICS FLOW TROUGH AN ORIFICE LAB SHEET

HYDRAULIC DEMONSTRATION CHANNEL

VERIS Accelabar. Superior Flow Measurement Accuracy

Flow Test Data Book and Flow Handbook for 405 Compact Orifice Series and 1595 Conditioning Orifice Plate

DZR Commissioning Set. Flow Data and Installation Instructions

Hydraulics Laboratory Experiment Report

TVA Target Variable Area Flowmeter

Rosemount 405 Compact Orifice Primary Element

Utility Flow Metering for Steam and Heated/Chilled Water: A Tutorial. Richard Gruskos Flow Products Manager Kessler Ellis Products

CHAPTER 6 : GAS SAMPLING SYSTEMS

Field Accuracy of Temperature Measurements in TAB Work Andrew P. Nolfo, PE

Rosemount Annubar Flowmeter Series. The Value of Innovation, Realized

Thermal Mass Flow Meters Help Reduce Energy Costs and Enhance Emissions Monitoring Systems

February 5, 2013 Roy Ratcliffe, President RM Controls, Inc.

An Intercomparison Between NEL, NRLM, Delft Hydraulics, Alden Research Laboratories, CENAM and NIST Using a 200 mm Twin Orifice Plate Package in Water

FLOW MEASUREMENT Product Code 316 Instruction manual Contents

DETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS

Naturally Entraining Solid Particle Injector

Programme area 4. Fluid Mechanics

Water Measurement. Presentation by. L. Niel Allen Extension Irrigation Specialist Utah State University

ERT 318/4 UNIT OPERATIONS SEMESTER 1 (2013/2014)

This document is a preview generated by EVS

DIVA flowmeter. for saturated steam flow measurement

EPA Method 1 Field Procedures Example:

ASME PTC Flow Measurement

introduced before the end of World War II. 2 They are less the focus of new product development than new-technology

Venturi Tubes in Wet Gas Improved Models for the Over- Reading and the Pressure-Loss Ratio Method

World s first LNG research and calibration facility

Gilflo flowmeters. for steam, liquids and gases

Impact of Pitot tube calibration on the uncertainty of water flow rate measurement

Understanding. Hydraulics. palgrave macmillan. Les Hamill. University of Plymouth THIRD EDITION

ANALYSIS OF APPLICABILITY OF FLOW AVERAGING PITOT TUBES IN THE AREAS OF FLOW DISTURBANCE

A/E REVIEW CHECKLIST STEAM GENERATION

Product Overview. JSP Industrial Controls. Your supplier:

Vortex Mass Flowmeter

Permanent Pressure Loss Comparison Among Various Flowmeter Technologies

Contour K5 Technical Information

Lecture 20: Groundwater Introduction

Geothermal Power Plant

Transient and Succession-of-Steady-States Pipeline Flow Models

Like piezoresistive, piezoelectric,

Flow Characterization of a Piezo-Electric High Speed Valve

Glossary Irrigation Terminology

High Efficiency Liquid-Solid Separators

Selecting the correct device for measurement control

CUSTODY TRANSFER FLOW MEASUREMENT WITH NEW TECHNOLOGIES. Stephen A. Ifft McCrometer Inc. Hemet, California, USA

Proven Flow Measurement Solutions for the Oil and Gas Industry

Australian Water & Irrigation Solutions Pty Ltd DECHLORINATION

FLUXUS F601. Portable, quick and reliable. Clamp-on ultrasonic flow meter. Measure from outside what's flowing inside

CFD on Small Flow Injection of Advanced Accumulator in APWR

FPI Mag Flow Meter. Next Generation Mag Meter: Solving WTP s Tight Installation Dilemma. McCrometer, Inc. (800)

It can be reliably stated that experience in South African and international

The Technical Challenges of Dissolved Oxygen Enhancement

Basic Irrigation Design

HYDRAULICS OF CULVERTS

MID R 800 AMR READY N E W MID R=800 ULTRIMIS W DATA APPLICATION WATER MEASUREMENT

Honeywell Thermal Solutions. Engineering Guide

Southwest Clean Air Agency NE 99 th St, Suite 1294, Vancouver, WA 98682

Regulating valves REG 6-65, REG-SS 15-40

DS-4018 English Rev. FA. ProPlate Flowmeter Mass ProPlate Flowmeter Model 1195 Integral Orifice


ON-SITE PROVING OF GAS TURBINE METERS Edgar B. Bowles, Jr., Southwest Research Institute

Available online at ScienceDirect. Procedia Engineering 102 (2015 )

2011 Standard for Performance Rating Of Water-Chilling and Heat Pump Water-Heating Packages Using the Vapor Compression Cycle

Introduction To Computational Fluid Dynamics. Presented by Marc Laing CFD Team Manager

Micro Hydro Turbine Test Facility at the NERDC

FLOW BEHAVIOUR OF COARSE-GRAINED SETTLING SLURRIES

APlus-QMC LLC. Catalog 2017

Biogas Conference Kolding, DK, 04 April 2017 BINDER. Biogas Monitoring Why and How? Jan Talkenberger, Manager International Sales, Binder GmbH

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER

Compact, Integrated System for Coating Pipe and Tubing

MEASUREMENT OF THE SINGLE AND TWO PHASE FLOW USING A NEWLY DEVELOPED AVERAGE BIDIRECTIONAL FLOW TUBE

Steam Meters Selection and Installation

Best Value Drip Irrigation Products High Quality Yet Affordable

Agricultural Pumping Efficiency Program. Flow Meters. Helping California Agriculture...

Slurry sampling. Benefits. Outotec slurry sampling

OPERATIONAL EXPERIENCE WITH SMALL VOLUME PROVERS. Class #4110.1

OPTIMASS 7400 Technical Datasheet

Industrial Flowmeters

Sho-Rate TM "50" Model 1350E and Sho-Rate TM "150" Model 1355E

Models 1350G & 1355G. Low Flow Glass Tube Flowmeters. Ships in 5 days. Overview. Product Features. Variable Area

The Influence of Chemical Inhibitor Addition on Reverse-Jet Flame Stabilization

Fluidised bed for stripping sand casting process. Guido Belforte, Massimiliana Carello, Vladimir Viktorov

Field Evaluations of Irrigation Systems: Solid Set or Portable Sprinkler Systems 1

Variations in the evaporation rate of a cryogenic liquid on a water surface. Harri K. Kytömaa, Ph.D., P.E. Timothy L. Morse, Ph.D.

Accutube Averaging Pitot Tubes

EFFECTS OF SHEAR AND CAVITATION ON PARTICLE AGGLOMERATION DURING HANDLING OF CMP SLURRIES CONTAINING SILICA, ALUMINA, AND CERIA PARTICLES

Manual of Petroleum Measurement Standards Chapter 5 Metering

OVERALL EFFICIENCY CONSIDERATION OF PNEUMATIC SYSTEMS INCLUDING COMPRESSOR, DRYER, PIPE AND ACTUATOR

Network Analysis of Turbine and Feedwater Systems of the Fugen Nuclear Power Plant

BURNERS EXCESS AIR SINGLE TUNNEL COOL FLAME

Airflow Measurement for HVAC Systems Comparing Technologies June 11, 2003

nhc EARTH TECH CANADA INC. CITY OF WINNIPEG NORTH END WATER POLLUTION CONTROL CENTRE PUMP STATION MODEL TEST FINAL REPORT JANUARY 2005

The Integral Optimization Method of Oilfield Production System

289 Series Spring-Loaded Relief Valves

Theoretical and Experimental Analysis of Fluidisation Phenomena in a Rectangular Multiphase Bed

PROJECT DESIGN DOCUMENT FORM (CDM PDD)

Baumann 24000F Wafer Body Control Valve

Transcription:

fluid mechanics H4 A compact unit that compares and shows the accuracy, losses and use of fundamental flow meters Key Features Unique quick-change flow meter adaptors and pressure connections Four tube manometer to show flow meter and overall pressure changes Nozzle flow meter included. Optional flow meters available for comparison include: Venturi, orifice and Pitot tube Shows the boundary layer effect and the fluid velocity profile needs Pitot tube (H4a) Works with TecQuipment s Hydraulic Bench for easy installation Learning Outcomes Accuracy of flow meters Losses and k value Calculation of the coefficient of discharge Key Specifications Unique quick-change adaptors Four tube manometer Nozzle flow meter included Three optional flow meters Downstream flow control valve Page 1 of 5

H4 Description For use by all kinds of engineering students, the Flow Meter Calibration apparatus compares and shows the accuracy and use of fundamental flow meters. The nozzle flow meter (included) or any of the optional flow meters quickly and easily fit into place between the adaptors in the base unit of the apparatus. Four waterfilled manometers show the pressure differences at the flow meter and across the overall flow meter assembly. The manometers have a common manifold fitted with an air valve. Students use the hand-pump (included) to increase the air pressure in the manifold. This offsets the manometer measurement (adjusts the datum). The straight pipe (included) gives a comparison of the true pressure losses caused by the flow meters. The optional Pitot Tube Flow Meter (H4a) will also show the velocity profile in a pipe. This helps to explain the boundary layer and surface friction in pipes and flow channels. The works with TecQuipment s Digital Hydraulic Bench (H1F, available separately)* and stands on the hydraulic bench worktop. Water enters from the left of the product and leaves at the right through a flow-control valve that sets the flow rate. This valve is downstream, so it does not cause any upstream turbulence. Standard Features Supplied with a comprehensive user guide Five-year warranty Manufactured in accordance with the latest European Union directives ISO91 certified manufacturer Essential Base Unit Digital Hydraulic Bench (H1F)* *This product will also work with existing TecQuipment Gravimetric and Volumetric Hydraulic Benches (H1 and H1D) Hand pump 75 mm Flow Meter (H4a) Flow control valve 9 mm Page 2 of 5

H4 Available Experiment Modules Pitot Tube (H4a) Venturi Flowmeter (H4b) Orifice Flowmeter (H4c) Page 3 of 5

H4 Typical Work Assignments Accuracy, Coefficient of Discharge and Losses This experiment tests a flow meter against the flow measured by the hydraulic bench to find its accuracy and calculate its coefficient of discharge from the gradient of calculated results. It also measures the losses of a flow meter and compares with those from a straight pipe to give adjusted pressure drop. When plotted against velocity squared (v2) over 2g, these results produce linear charts of pressure drop, of which the gradient gives a k value for the flow meter. Measured flow rate (hydraulic bench) Nozzle Flow Meter Discharge Coefficient =.95 A 2 2g h 2 1-(A 2/A) 1 2 v /2g Adjusted Pressure Drop k Page 4 of 5

H4 Detailed Specifications TecQuipment is committed to a programme of continuous improvement; hence we reserve the right to alter the design and product specification without prior notice. Nett dimensions and weight: 75 mm high x 9 mm long x 3 mm front to back and 9 kg (including Nozzle Flow Meter) Approximate packed volume and weight:.4 m 3 and 16 kg Operating Conditions Operating environment: Laboratory Storage temperature range: 25 C to +55 C (when packed for transport) Operating temperature range: +5 C to +4 C Operating relative humidity range: 8% at temperatures < 31 C decreasing linearly to 5% at 4 C Page 5 of 5