SELECTION GUIDE Appearance Sensing distance Operation Mode Connector Shape example (M8) Outer diameter (Ferrous material only) Wiring Output Output no

Similar documents
SMAW. Shielded metal arc welding (SMAW) is commonly referred to as stick welding

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

Bonded Neo Magnetization Guide

Bulletin 800F Plastic and Metal Operators 22.5 mm mounting hole IP65/66, Type 4/4X/13 Internationally rated operators

Carbon film resistors

INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS

ARC STUD WELDING SYSTEMS

AHP WELDS USER MANUAL

Operate Manual. DA-1600i Stud Welding Machine. DA-2000i Stud Welding Machine. DA-2500i Stud Welding Machine

Over pressure Switching pressure difference (typical) Lower range Upper range

Extended-Frequency SMA Connectors

ACT. Summary. 1 Introduction. 2 Synoptic. 3 Technical characteristics. 4 Part-numbering system. 5 Arrangements. 6 Receptacles. 7 Plug / Panel seal

Welding Accessories

Multi-contact Compact Circular Connectors

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103

MGO INSULATED THERMOCOUPLES INDEX

SPECIFICATIONS: If your preferred product configuration is not shown, please contact our sales representative for custom design.

TOOL TECH WELDING & PACKAGING PRODUCTS 2017 RETAIL & WHOLESALE. Call : , (0422) SALES SERVICE SPARES

Amphenol RF- SMA Connector Series

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

AP5K-C Precision AC Double-Pulse Spot Welding Machine User s Manual Shenzhen Will-Best Electronics Co., Ltd

SURFACE TEMPERATURE SENSORS

Datasheet RS Pro RS Series Axial Carbon Resistor 1kΩ ±5% 2W ppm/ C RS Stock No:

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

ENGLISH Datasheet JIS Miniature Thermocouple Connector PCB Mounting Socket Types K, J, T, E, R/S & B (JIS Colour Code)

USER S MANUAL 400W and 600W

Introduction. Online course on Analysis and Modelling of Welding. G. Phanikumar Dept. of MME, IIT Madras

catalog Copper Wires

BM SERIES COMPACT GUIDE WAVE GUIDED WAVE RADAR LEVEL INSTRUMENTS

Multi-Purpose Mechanized Welding Carriage

Data Bus Connector and Terminator Requirements Document DB-1001-A. Revision C

INNOVATIVE LIFE-CYCLE CONCEPTS FOR MEDIUM-VOLTAGE SWITCHGEAR ON BROWN COAL SURFACE MINING DEVICES

RN Optical Termination Panel (RN OTP)

Fig. 1 - Standard Clevis Hanger

Construction guideline

Features SCL-DPDT SCL-DPDT-C1 SCL-DPDT-V SCL-DPDT-S SCL-D-DPDT SCL-D-DPDT-C1 SCL-D-DPDT-V SCL-D-DPDT-S

Superstrut. Metal Framing. Pipe Straps, Pipe Clamps and Hangers

Magnetic float switch For vertical installation Model FLS for nuclear power plants

SERIES MP320 & DERIVATIVES

2-finger angular gripper SGB 32-50

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories

2 Ohm Nominal Component Speaker System OWNER S MANUAL

Spring Pressure Connection Technology Vibration-Proof Fast Maintenance-Free

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

Bushing diameter 16 mm, 19 mm or 22 mm. Easy to clean metal surface. Very long life expectancy. Ring or dot illumination. ➀ One-piece bushing

Spark and spatter. Sparks and spatter cause risk of fire and damage. Cepro welding blankets and grinding curtains offer secure separation.

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

Schmidthammer. 06 High current carbon brushes. Elektrokohle GmbH. Transmission systems with linear adjustable telescope holders p.

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

SECTION 2: PROBES. Page 2-1

Knot Wheel Brushes WHEEL BRUSHES


WE01A GMA (MIG) Plug Weld

Small Terminals. TEST CURRENT (Amps) Fig 1. Tensile strength of YAD HYLUG after axial rotation stresses. TENSILE STRENGTH IN POUNDS

SIP Hi-TECH Range exclusive to SIP

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

Thermocouples and Accessories Product Catalog

Liquid level switch BW 17

Reference Only. Spec. No. JENF243D-0006K-01 P 1/ 8

ENGLISH Datasheet JIS Miniature Thermocouple Connector In-Line Plugs Types K, J, T, E, R/S & B (JIS Colour Code)

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

High Durability Cables Cordsets for use in extreme conditions in manufacturing

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-BIPV-SM-P125-36

EC medium pressure axial fans.

Alternating Current Potential Drop for Measuring the Case Depth of Hardened Steel

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P156-60

Features 1.34 In Width X 1.53 In Height X 1.13 Recp gang Stainless Steel/304 Stainless Steel

REV. 9/08. Mounting Structure PRE-INSTALLATION GUIDE for Ergon Skybooms

NTC thermistors for temperature measurement

D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Valves. MUELLER Tapping Sleeves and Crosses. MUELLER Stainless Steel Tapping Sleeves

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

CITOSTEP. MIG/MAG Step controlled range. A step forward into intuitive welding.

Welding Processes. Consumable Electrode. Non-Consumable Electrode. High Energy Beam. Fusion Welding Processes. SMAW Shielded Metal Arc Welding

U.V resistance UL Sunlight Resistance. Flame retardant IEC

I. Overview. General Considerations

SPRING LOADED THERMOCOUPLE CONFIGURATIONS

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

AC/DC MULTI-200P AC/DC MULTI-220P

TEMPERATURE SWITCHES AND THERMOSTATS

PNP Series Sealed Pushbutton Switch

YINGLI SOLAR PANDA BIFACIAL MODULES Installation and User Manual

Reference Only. Common Mode Impedance Rated (at 100MHz,Under Standard Voltage Testing Condition) V(DC) (Ω ) 67 ± 25 %

SPEEDTEC 180C & 200C

Fieldbus Systems. Fieldbus System: CC-Link

THERMOCOUPLES and THERMORESISTANCES - Temperature measurement sensors for industrial use Figure 1: Standard Thermocouples

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

SERIES MP320 & DERIVATIVES

Product Specification JUL 14 Rev. A1

MICRO-INVERTER PIGRID W MICRO GRID TIED INVERTER 208, 220, 230, 240VAC

GMAW (MIG) / FCAW / MCAW

Quick Installation Guide. MVC-PTZ-23X Indoor/Outdoor 23 PTZ Speed Dome Camera

Training Guide Electric Arc Welding (non code).

WE11S GMA (MIG) Fillet Weld

12.1 MUELLER TAPPING MATERIALS AND SPECIALTY VALVES. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves. MUELLER Stainless Steel Tapping

Cannon Trident Connector System

Notes Changed note Date. 1 (A) Changed template 09 / 07 / 2008

Galvanic and Stray Current Corrosion

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC Van Dam Street Long Island City, NY ELECTRIC METER SHOP DEPARTMENT

Transcription:

Stainless Steel Sensing Face Proximity Switch Model FL7S The FL7S is a proximity switch having a stainless steel sensing face and housing, and is specially designed for welding applications on the automobile manufacturing line. The sensing face is integrated into a stainless steel housing having high shock resistance and superior abrasion resistance Switches have a spatter and slag proof special coating An electromagnetic field noise elimination is built in The lineup includes M8, M2, M8 and M0 models * Connector-type cables are also available for the FL7S Series. PA5-ISXm FK-E (incombustible cable) Ex.: PA5-ISXm UK-E (flame-resistant cable) ADVANTAGES OF FL7S SWITCHES The sensing face is integrated into a single stainless steel housing. 0.7 mm Special spatter-resistant coating Highly resistant toelectromagnetic field noise from welding! Extra-tough filling material FL7S SERIES ENDURANCE TEST RESUCTS Two endurance tests were made in order to develop a switch that could meet the severe requirements demanded by users in the field. The FL7S Series has proven to have superior performance in both tests. strength tests TEST- With conventional switches, welding sparking leads to hard-to-remove spatter and slag.the big problem is the scratches caused by the abrasive metal brush used to remove the stuck spatter and slag. Azbil has solved this major problem by creating for the FL7S Series a stainless steel sensing face that resists abrasion. The Metal Brush Test shows that this switch has excellent endurance. Stationary The Metal Brush Test (measurement of abrasion resistance) FL7M-7J6HD FL7M-7J6HW FL7S-5W6W-CN0 Rotating Test condition Brush: Stainless steel brush Rotation speed: 0 cycles/min TEST-2 Survives 5 min of brushing Stationary Rotating Repetitive Shock Test (measurement of shock resistance) Housing survives 0 repetitions Resistance to electromagnetic field noise from welding! Welding current (A) (DC or AC) 0,000 20,000 0,000 2.7 60mT mt 70mT 25. 80mT 60mT 25mT well! Operation is normal even after 200 minutes! Repetitive shocks when welding parts hit the switch head result in a shortening of switch life. The FL7S Series' greatly strengthened stainless steel sensing face is the answer to this problem! The repetitive shock test has proven that this switch has robust shock resistance. FL7M-7J6HD Test condition Brush: Stainless steel brush Rotation speed: 0 cycles/min Survives 25 min of brushing orking Still w Usable range (for FL7S-2/5/8 Series) Distance between welding gun and switch (mm) 5 76 02 27 0mT 25mT 20mT 6mT 80mT 50mT 0mT 0mT 20mT 80mT 60mT 50mT FL7M-7J6HW FL7S-5W6W-CN0 Housing survives 5,000 repetitions 2 06 mt 25mT 0mT 7mT mt 20mT well! Operation is normal even after 200,000 repetitions! Distance between welding gun and switch Ex.: When the welding current is 0,000A, the switch operates without error even when it is installed as close as approx. 2.7 mm from the welding gun. orking Still w

SELECTION GUIDE Appearance Sensing distance Operation Mode Connector Shape example (M8) Outer diameter (Ferrous material only) Wiring Output Output non-polarity (Cable length: M8=80 cm, others=0 cm) - M8.5 mm - M8 M2 M8 M0.5 mm 2 mm 5 mm 8 mm - - - - - - -wire NPN -wire PNP FL7S-W6W-CN0 FL7S-W6W-CN0B FL7S-A6W-CN08 FL7S-D6W-CN08 FL7S-2W6W-CN0 FL7S-2W6W-CN0B FL7S-5W6W-CN0 FL7S-5W6W-CN0B FL7S-8W6W-CN0 FL7S-8W6W-CN0B Appearance Sensing distance Operation Mode Shape example (M8) Outer diameter (Ferrous material only) Wiring Output (Cable length: 5 m) M8 M2.5 mm 2 mm FL7S-W6W-L5 FL7S-2W6W-L5 M8 5 mm FL7S-5W6W-L5 M0 8 mm FL7S-8W6W-L5 Catalog listing SPECIFICATIONS Actuation method Rated sensing distance Standard target object Differential travel Rated supply voltage Operating voltage range Current consumption Voltage drop at ON Control output Leakage current Switching current Operating frequency Temperature characteristics Operating indicator Operating temperature range Storage temperature range Dielectric strength Vibration resistance Shock resistance Protection Electromagnetic field noise resistance thickness -CN Weight -L5 FL7S- 6W-CN08 FL7S-W6W-CN0(B) FL7S-2W6W-CN0(B) FL7S-5W6W-CN0(B) FL7S-8W6W-CN0(B) FL7S-W6W-L5 FL7S-2W6W-L5 FL7S-5W6W-L5 FL7S-8W6W-L5 High-frequency oscillation type.5±0. mm * 2±0.2 mm * 5±0.5 mm * 8±0.8 mm * Iron 8 x 8 mm, t= mm Iron 2 x 2 mm, t= mm Iron 8 x 8 mm, t= mm Iron 0 x 0 mm, t= mm Max. % of sensing distanc 2/2 Vdc 0 ma max. 2V max. 0 μa max. 00 ma max..8v max. (switching current 0 ma) 5.5V max. (switching current 0 ma) 0.8 ma max. ma to 00 ma 5 Hz Hz 5 Hz +% of sensing distance (25 C) ( +60 C) ±0% of sensing distance (25 C) ( +60 C) Lights (red) at output ON +60 C +60 C 500 Vac, 50/60 Hz between case and electrically live metals 55 Hz, mm peak-to-peak amplitude, 2 hours in X, Y and Z directions 29 m/s 2, 6 times in X, Y and Z directions *2 IP67 * 00mT * 250mT 0. mm 0.7 mm 0 g 50 g 50 g 70 g 0 g 90 g 200 g 220 g 280 g Circuit protection Reverse connection protection, output short- Electromagnetic field noise elimination Material Switch body Stainless steel 0 (with spatter and slag proof special coating) * : Does not detect non-ferrous metals. * 2: Avoid using this switch in an environment always subject to splashing water or oil. * : AC/DC magnetic field 85 ms or less 2

EXTERNAL DIMENSIONS (unit: mm) FL7S- 6W-CN08 (SUS0, t=0. Toothed washer (iron) M8x FL7S-2W6W-CN0(B) 25 5 Washer ( 6.5 dia. dia. (PVC) 800 min. () M2 x M2x FL7S-W6W-CN0(B) (Stainless steel, t=0. M8 x Washer (iron) 2 7.9 dia. 5.6 dia. FL7S-5W6W-CN0(B) Washer ( (SUS0, t=0.7 M2 x 500 min. Hexagonal nut (Brass, Case (Stainless steel,. dia. (PVC) with sleeving tube Inline Amplifier 0 0 Case (Stainless steel, Vinyl-insulated cord, TPE.8 dia., VW- (8.2) M2x M2x 7 M2x 2 26 0 TPE.8 dia. (8.2) 2 M8x.5 55 TPE.8 dia. (8.2) FL7S-8W6W-CN0(B) Washer ( M2x M0x.5 27.8 dia. 6.85 9.5 56 28 dia. Insulated cord, TPE.8 dia. (8.2) Note: When the switch is flush-mounted in metal, be sure to mount it so that the top of the sensing face projects 2 to mm from the metal surface. FL7S-W6W-L5 FL7S-2W6W-L5 (Stainless steel, t=0. Washer (iron) Case (Stainless steel,. dia. (PVC) with sleeving tube.8 dia. (PVC), VW-, 0. mm 2 Washer ( M8 x 2 7.9 dia. 5.6 dia. M2 x Inline Amplifier Conductor (Copper) 0 500 min. 0 7 M2 x 2 26 0 5 dia. (PVC), VW- Conductor (Copper) FL7S-5W6W-L5 Washer ( FL7S-8W6W-L5 Washer ( Insulated cord, 5 dia. (PVC), VW- 2 M8 x.5 55 5 dia. (PVC), VW- Conductor (Copper) 6 M0 x.5 27.8 dia..85 9.5 56 28 dia. Conductor (Copper) Note: When the switch is flush-mounted in metal, be sure to mount it so that the top of the sensing face projects 2 to mm from the metal surface.

OUTPUT CIRCUIT AND WIRING non-polarity type -CN0 -CN0B () () -wire type () The load can be connected to either of the power supplies. PNP () The load can be connected to either of the power supplies. NPN Brown (/Blue) Blue (/Brown) The load can be connected to either of the power supplies. CONNECTOR WITH CABLE Be sure to use a Model PA5 connector with cable when connecting a preleaded connector or connector-type switch. Model PA5 connector with cable Shape Power supply Cord properties Cord length Lead colors Model PA5 connector with cable Male DC Vinyl-insulated cord with high resistance to oil and vibration (UL/NFPA79 CM, CL) Female 2 m 5 m 2 m 5 m PA5-ISX2SK PA5-ISX5SK PA5-ILX2SK PA5-ILX5SK : brown, 2: white, : blue, : black : brown, 2: white, : blue, : black : brown, 2: white, : blue, : black : brown, 2: white, : blue, : black Tightening the connector Align the grooves and rotate the fastening nut on the PA5 connector by hand until it fits tightly with the connector on the switches side. Switches side PA5 connector side Switches side (male) Connector side (female)

PRECAUTIONS FOR USE. Influence of surrounding metal Metal other than the target object surrounding the switch may influence operating characteristics. Leave space between the switch and surrounding metal as shown below. A B C C 2. Mutual interference prevention When mounting proximity switches either parallel to or facing each other, mutual interference may cause the switch to malfunction. tain at least the distances indicated in the figures below. Parallel Facing each other A B Shaded areas indicate surrounding metal other than the target object. A: Distance from sensing face of proximity switch to mounting surface B: Distance from surface of iron plate to sensing face of proximity switch. Dimensions in parentheses apply if a hexagonal nut is attached to the front. C: Distance from surface of iron plate to center of proximity switch when A=0 FL7S- FL7S-2 FL7S-5 FL7S-8 A(mm) 6 2 6 60 B(mm) 20 0 50 00 FL7S- FL7S-2 FL7S-5 FL7S-8 A(mm) B(mm) C(mm) 0 0.5 6 2 8 2 6 2. Mounting FL7S- FL7S-2 FL7S-5 FL7S-8 Max tightening torque (N m) 8 0 60 5

[Notice] Advanced Automation Company Oct. 207-AZ