Cable kit (TPP) Installation Instructions

Similar documents
WARRANTY INSTALLATION MANUAL. Ultra thin cable. Easy to install. Fully compliant to latest regulations CE approved INSTALLATION MANUAL

UNDERFLOOR HEATING SYSTEM INSTALLATION MANUAL LIFETIME WARRANTY INSTALLATION MANUAL. Ideal for large areas. Easy to install

Warmup helpline:

NATURE INTERNATIONAL NEW ZEALAND LTD.

Installation Manual. ThermMAT ThermCABLE FME. Technical Helpline:

Undertile Heating Mat Installation Manual

Installation Manual 150W/m²

Installation Manual Loose Cable Heating

MESH FLOOR HEATING SYSTEMS INSTALLATION INSTRUCTIONS

Nuheat Mat FLOOR HEATING SYSTEM. Installation Guide TILE, STONE & MARBLE LAMINATE & ENGINEERED WOOD

Technical Helpline. Installation Manual. Warmup DCM-PRO. Electric Heating System

Veria Quickmat 1C 100/150W/m²

RADIANT PANEL SYSTEM PLANNING & INSTALLATION. Roth Radiant Heating Systems

Installation Guide. Floor heating. Vodoley CO

TempZone Custom Mat Electric Radiant Floor Heating System Installation Manual

ELECTRIC CABLE GUIDE

Nuheat Mat Installation Manual Nuheat Electric Floor Heating System

TILING SPECIFICATIONS

Mat PRE-BUILT ELECTRIC FLOOR HEATING MAT INSTALLATION GUIDE

Robust, 17 th Edition and Part L Compliant

HYBRID. Pre-Laying Checks

EverWarm FAQ - What is EverWarm? EverWarm How does EverWarm work?

UNDERFLOOR HEATING SYSTEMS ESTIMATE NOTES AND DETAILS

Type FLX Freezer Floor Frost Heave Protection DESIGN GUIDE

Installation Guide Details correct as of December 2013

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification

Installation Manual. Snowmelt Cable 25W/m (W25SM) TECHNICAL HELPLINE

Commercial Resilient Sheet Flooring

DURABASE CI 1/5. Underlay mats for decoupling and waterproofing tiled flooring APPLICATIONS AND FUNCTION.

REV:6-30/09/30. Liquid Rubber Timber Specification

MILLIMATTM - Underfloor heating mat

TECHNICAL BULLETIN TB147 THE INSTALLATION OF ARDEX DS40 SOUND REDUCTION MATTING IN INTERNAL INSTALLATIONS

SECTION LATEX-MODIFIED MEDIUM BED MORTAR

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

Installation Manual for your TempZone Electric Radiant Floor Heating System (Twin Conductor)

Elegant design with the high performance heating technology of tomorrow - today. Electric Combination Radiator Systems

Nuheat Cable FLOOR HEATING SYSTEM. Installation Guide TILE, STONE & MARBLE LAMINATE & ENGINEERED WOOD

1.3 Work shall include all reinforcement and accessories necessary to complete installation.

Cable ELECTRIC FLOOR HEATING SYSTEMS INSTALLATION GUIDE

Geometric and Quarry Floor Tiling Installation Guide

Freedom One-Piece Barrier Free Showers Installation Instructions

INSTALLATION MANUAL

Caparol System PRO Data sheet

AQUATITE. Also designed as: Crack/gap filler for masonry and unglazed ceramics Sealants against leaks Repairer for roof cracks and gutters

Schlüter -DITRA-HEAT-E Under tile and stone heating with Schlüter -DITRA technology Installation Manual

GLUE-DOWN INSTALLATION VIRTUO 30 / 55

RMF Intercell. NBS Specification 2013 K41

Fiber Reinforced Tile and Stone Mortar

DURABASE CI. Underlay mats for decoupling and sealing tiled flooring 1/5 A P P L I C A T I ONS AND FUNCTION.

3000 FLEX-WARM DIV 9 ANSI A118.12

Floors Walls Roofs. Jabfloor Premium board Jablite Premium board Jabfloor board Jablite board. APPLICATION: Basements PRODUCTS: Vencel Resil Limited

Ground Terraces. bal-adhesives.com. Part B: Installation Guide

C&G 2382 BS7671: th Edition IEE Wiring Regulations. 25 Questions

Kolorines Glass Mosaic Tiles Project Specification

USA USA USA PURE CLICK

Application Guidelines

ECO OUTDOOR INSTALLATION TIPS FLOORING TORINO MELBOURNE SYDNEY BRISBANE ADELAIDE PERTH T ECOOUTDOOR.COM.AU

TempZone Electric Radiant Floor Heating System (Twin Conductor) Installation Manual

1. Division 09 Section "Rough Carpentry."

Slate Floor Tiling Installation Guide

COMPOSITE (WPC) ENGINEERED VINYL FLOORING INSTALLATION

Geometric and Quarry Floor Tiling Installation Guide

Specialists in Acoustic Flooring and House to Flat Conversions

FOR TILES AND NATURAL

The following instructions should be reviewed prior to installation. Shaw Industries will not be responsible for improper installation.

Channel Drain Shower Base. Aqua Line pro. Installation Instructions

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

UNDER TILE HEATING INSTALLATION MANUAL FEBRUARY 2016

Radon Vent Pipe System. Labeling Performance Indicators

HYDRATHANE INTERIOR WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 959 [2017] Appraisal No. 959 (2017) BRANZ Appraisals

RAUPEX SPEED SYSTEM Installation Guide

Mapei systems for radiating floor heating with high thermal efficiency

Installation Instructions for CushionBac Renew Tiles

ITEM 458 WATERPROOFING FOR STRUCTURES

SILASEC DESCRIPTION FEATURES AND BENEFITS SURFACE PREPARATION

Highly Chemical Resistant Laminate System. Sika Asplit VEL is 2 part, glass fabric reinforced, vinyl-ester based coating and lining system.

Application Instructions for Keystone Kool Deck on Existing Concrete

LAMINATE FLOORING. 10 Year BUYING GUIDE. IKEA Lock Locking System. Easy Connect Locking System

Suggested Specification for Tri-Patch Versatile Concrete Patching Compound

ITALIAN CREATIVITY IN THE SERVICE OF DESIGN. Ginevra

Drying of Concrete TDS 183

WOOD FLOORING WOOD FLOORING

TILE TILE

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

SECTION HYDRAULIC CEMENT UNDERLAYMENT

SNOW-MELT Heating Cables Snow & Ice Melting Applications (Outdoor)

REF : WEBSITE08. Monday, 12 December 2011

VINYL COMPOSITION TILE

VINYL TILE, SHEET & LAMINATED FLOORING TRADE SPECIFICATION

FLOORING FOR FLOOD-PRONE AREAS. Vinyl Flooring. Pros of Vinyl Flooring for Flood-Prone Areas

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

When I started tiling, we didn t do our own shower pans that BATHS

Contura Floating Floor Underfloor Heating Installation Manual

Subfloor heating and cooling instructions for Hakwood flooring products Duoplank 20mm (¾ ) and Duoplank 15mm (⅝ )

Elegant design with the high performance heating technology of tomorrow - today. Electric Combination Radiator Systems

Construction. Pulastic Coating-221 W. 2 Component Polyurethane

PPC Cement TUTORIAL. how to screed a floor

INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS

SpaVault TM Installation Guide for Bullfrog Spas (7-10 x 7-10 x 38 )

TOUCH FOIL INSTALLATION GUIDE

Transcription:

Cable kit (TPP) Installation Instructions

Cables (BLUE) ambi-heat brand manufactured by Thermopads Before you begin installing please read through these instructions carefully & check that you have all the components required. The system is designed for installation below tiles, stone or marble flooring, it may also be installed below vinyl, laminate & thin carpets but in these cases must first be covered with a suitable fibre reinforced levelling compound. Contents of heating kit: 3mm twin-core, earth screened heating cable on drum(s) Smart tack spray adhesives Double sided edge tapes High adhesion fixing tapes Digital thermostat with 2 x floor temperature sensors Guarantee Certificate (page 10 of this booklet) Installation Notes 2 The system requires a mains voltage 230/240v & must be connected by a suitably qualified person in accordance with part P building regulations. All wiring must conform to current IEE wiring regulations. The system is intended for heating tiled or stone floors, typical recommended outputs are: 130watts per sqm, achieved by spacing the cable at around 7.0cms between the loops. 150watts per sqm, achieved by spacing the cable at around 6.5cms between the loops. 165watts per sqm, achieved by spacing the cable at around 6.0cms between the loops. See supplementary instructions when calculating your actual cable spacing. The cable is double insulated & inside the first outer sheath (coloured black) there is an earth screen (the copper coloured braid). The cable also contains a built in return meaning that the cable only has to be connected to the thermostat from one end. Within the cable core there are 2 wires - one brown, one blue - these are the live & neutral. For larger areas, if two or more cables are supplied, these can usually be connected together at the thermostat or by using a small blank fronted connection box. Cables must be connected in parallel. The system is suitable for installing on any sub-floor which is sound and suitable for tiling, in general this will be concrete, plywood or cement faced tile-backer boards some water resistant composite boards may also be suitable, but it is not recommended to tile directly onto hardboard MDF or standard grade chipboard as these substances absorb moisture & subsequent swelling could cause tiles to crack or dislodge.

Note - if installing on a newly finished concrete screed the required minimum drying out or curing period should be followed before installing your heating. The electrical & electromagnetic fields generated are negligible & well within all recommended European & International guidelines. The Blue heater cable MUST NOT be cut, shortened or joined at any point. Electrical Provision Before starting the installation you should make provision for the electrical connections, for smaller areas this may be possible by means of a switched fused spur with an appropriately sized fuse or a combined RCD spur from an existing circuit - see above. However for larger areas a dedicated circuit from the consumer unit will be required you should always consult with your electrician concerning your specific requirements. Note - if installing in a bathroom or other wet room the thermostat must be located OUTSIDE of the room, for example in a bedroom or hallway/ landing. Preparation Ensure that the sub-floor is solid & suitable for tiling, free from dust & debris. Wood flooring with more than 30cms between the joists should ideally be reinforced to prevent flexing & the possibility of tiles dislodging. Wood flooring can be reinforced using WBP plywood or a reinforced cement coated tile-backer board. Insulation The insulation levels of a floor will affect both the performance & running costs of an underfloor heating system & adequate insulation is recommended wherever possible. It would not generally be considered necessary to insulate small areas where the requirement is simply to take the chill off the floor, however in cases where the heating is being installed over large areas, particularly as the primary heating source in a ground floor room or conservatory, insulation boards will greatly reduce warm-up times & running costs. Always use a reinforced cement coated insulation board where possible. Important Notes: The system MUST incorporate a 30ma RCD protection either at the distribution board or by replacing the fused spur with a combined fused spur/rcd. The blue heater cable MUST NOT be cut or joined at any point only the black cold cable & floor probe can be cut or lengthened. The joint between the blue heater cable & the black cold cable MUST be located under the floor, do not bend this connection. For larger areas a separate circuit will be required always consult your electrician concerning your specific requirements. The thermostat has a rating of 16amps loads in excess of 16 amps (3.6kw approx) will need to be connected via a suitable switched contactor consult your electrician on this. The thermostat MUST NOT be located in a bathroom. 3

Installation First prepare the sub-fl oor ensuring that it is clean & free from grease, dirt or debris. Note - if installing on a bitumen base, this must either be removed or covered with a suitable insulation board (Marmox) before proceeding. The most suitable sub-fl oors are: concrete, tile-backer boards, existing tiles, water-resistant timber e.g. WBP Ply. Supplementary instructions for Pro-installer cable packs (TPP) and (SC) Pro-installer pack contents. Heavy duty double sided tape, Smart tack spray adhesive, strapping tapes and additional (back up) fl oor temperature probe. Prior to installation of your heating cable system please ensure that correct size heating system has been ordered. Cable spacing - Measure the physical fl oor area to be heated (m²) and divide by total length(s) of cable to determine spacing between cable loops. Target Range 60mm 70mm (6.0cm 7.0cm). Do not attempt to lay cables if calculated spacing is below 50mm. 1. Vacuum the fl oor area thoroughly to remove dust and debris. 2. Apply smart tack spray adhesive as shown below, it is generally best to run heating cables at 90º to te thermostate wall. 3. Double sided adhesive tapes are bonded to spray adhesive coating after a few minutes drying time. Tapes are fi xed in twin parallel lines starting approximately 6cm out from the adjacent wall. 4 4. Cables are run between the taped lines at the pre-calculate intervals, loops are positions on the double sided tape and then secured with strapping tape, ensure that cables are pulled taught to keep them as fl at as possible to the fl oor.

5. Once cables are laid out and held securely in place across the loop ends additional strapping tapes are applied across the heating cables to run along the spray adhesive trails applied in step 1. 6. Primary and secondary floor probes are sited adjacent to each other between cable loops approx 300mm in the heated area. Spray adhesive and double sided tapes are used to hold probes securely in place. Only the primary probe is connected to the thermostat, the secondary or reserve probe is left disconnected and coiled up behind the thermostat. In the unlikely event of probe failure the secondary unit can be connected in place of the faulty unit. 5

Step 5 Calculate the cable spacing, this is a very important step & MUst be done correctly to ensure all the cable is used up & avoid extra work later. First measure the area to be heated in m² (do not include the area taken up by fi xed objects such as baths/showers & kitchen units), then divide this area by the length of the cable shown on the drum. The cable is 10 watts per linear metre so for example a 350 watt kit contains 35 metres of heating cable. The spacing is calculated by dividing the total m² of the area actual to be heated by the cable length in metres (cable length on side of packaging). Step 6 Once the spacing has been determined, leaving a perimeter of 5cms around the edge of the room, mark out the fl oor at the calculated intervals. This will usually be between 6 & 8cms if your calculated spacing is less than 5cms stop & do not install the kit size is too large for the room. A spacing of 8cms will in many cases will only take the chill off the fl oor to use as a heating source in most domestic situations the spacing would be between 6-7cms (this is always dependent on insulation levels & type of construction). Step 7 Once marked out, position one roll of tape in each corner of the room (Fig 3) & then begin to loop out the cable as shown (Fig 4). At this stage only use a single line of tape at each edge in case you have to adjust the spacing slightly later. You must ensure that the cable is only installed in the free fl oor area & is not routed below any fi xed objects or drains. Note the joint between the black cold cable & the Blue heater cable MUST be located under the fl oor tiles. Do not BenD the CoLD tail ConneCtion. Step 8 Adjust the spacing if necessary to ensure all the cable is used up & the fl oor has an even covering then tape over the cable at regular intervals, ensuring that it is well secured to the fl oor. Step 9 Position the sensor between two runs of cable & tape into position within a conduit. The conduit housing will need to be channelled in to your subfl oor to remain fl ush with the heating cable. The sensor wire can be shortened or lengthened, but if you need to cut it only cut the end containing the wires. Do not cut the end which contains the plastic sensor. 6 The connections to the thermostat can now be made but Do not turn the system on until it has been tiled. (See separate instructions with thermostat).

Step 10 Test the cables resistance again using a multi-meter. If you do not have access to a multi-meter, you may fi t a fused plug & plug the system into a socket for a few minutes to ensure that the cable starts to heat up. Do not leave the cable plugged in for more than 5 minutes & UnDeR no CiRCUMstanCes should you plug the system in when the cable is still on the drum or partly coiled up. Step 11 If desirable, cover the cables with a thin layer of latex based levelling screed (4-5mm), this will help protect the cables when tiling. There are many suitable products available. Details of manufacturers can be found later on. If you do not wish to use a latex levelling screed, you may tile directly over the cables in a single operation, however, extra care must be taken not to damage or dislodge the cables. If you are using a suitable vinyl or thin carpet as the fi nal fl ooring, we recommend a minimum 8mm (5+3) screed over the cables to ensure even heat distribution. Step 12 Tile the fl oor using a fl exible tile adhesive & grout as per industry standards & the manufacturer s instructions. Entire heating cable must be fully embedded. Finally wait at least one Week before turning the heating system on to allow time to dry. note The heating may be slow to react at fi rst, especially if installed on a new screed fl oor or in a new building start by setting the fl oor temperature at around 20-22º C and build up by 2 degrees per day until your desired temperature is reached (usually 25-28º C). Please see separate instructions for connection & operation of the digital thermostat. 7

Testing your Cables All Ambient / Thermopads heating cables and mats are tested prior to leaving the factory, however, it is important to carry out the resistance checks detailed on the guarantee card to ensure correct operation of the heating system and to ensure full compliance with the guarantee. Test the cables resistance again using a multi-meter. If you do not have access to a multi-meter, you may fi t a fused plug & plug the system into a socket for a few minutes to ensure that the cable starts to heat up. Do not leave the cable plugged in for more than 5 minutes & UnDeR no CiRCUMstanCes should you plug the system in when the cable is still on the drum or partly coiled up. The connections to the thermostat can now be made but Do not turn the system on until it has been tiled. (See separate instructions with thermostat). Do s & Dont s Do Fully embed the Heating cable Read through these instructions carefully before beginning work Use fl exible adhesives & grouts Test the cable BefoRe and after tiling Be careful not to damage or dislodge the cable during tiling Ensure the cable is spaced no closer than 50mm between loops Try to protect the cable with cardboard or carpet during tiling Wait at least 7 days before turning on the system Read the separate installation & operating instructions for the thermostat Ensure that the joint between the black & blue cable is fully embedded beneath the tiles Don t Attempt to cut the blue heater cable at any point Allow the wires to cross or touch Allow foot traffi c over the wire before tiling Cut tiles directly over the cable Place tools or stacks of tiles on top of the cable Do Ring your supplier for advice if in doubt regarding any aspects of your heating installation. technical support: 01799 524730 8

Resistance Tables 3mm Twin Wire Cables Watts (power) UnDeR tile CaBLes BY thermopads Length (Meters) Resistance (ohms) 115 11.5 460 140 14 378 170 17 311 225 22.5 235 290 29 182 350 35 151 400 40 132 480 48 110 560 56 95 640 64 83 700 70 76 760 76 70 820 82 65 920 92 57 1040 104 51 1140 114 46 1250 125 42 1450 145 36 1600 160 33 1800 180 29 Resistance readings tolerance = +10 / -6% All cables are resistance tested post production, a specifi c reading for each cable will be shown on the side of the cable box. Insulation resistance L+N to Earth should be greater than 500mΩ Technical Support Tel: 01799 524730 Email: info@ambient-ufh.co.uk floor temperature PRoBe Resistance (ohms) 15k @ 15 C - to - 12k @ 20 C 9

Guarantee Certificate Ambient Electrical Ltd. Under tile Cables, Mats, in screed systems & thermolam This guarantee is only valid if installed by a qualifi ed electrician/electrical contractor. This installation must conform to Part P of the building regulations 2005 and be carried out in accordance with current IEE wiring regulations. In order to validate the guarantee the resistance values & signature of the installer must be completed. A currently calibrated piece of test equipment must be used. The guarantee covers reported manufacturing defects within the heating cable for the life time of your fl oor fi nish or 15 years whichever is the sooner; programmable thermostats and fl oor sensors are covered for a period of two years from date of original invoice. Faulty components covered by this guarantee are repaired or replaced at our discretion, where repair or replacement is not practical a refund of original purchase price may be offered. Other costs such as replacement or repair of fl ooring materials are not covered by this guarantee. The guarantee is invalid if faults are caused by damage attributable to incorrect installation, misuse or mechanical damage such as drilling or puncturing the fl oor. Please retain this guarantee along with your original purchase invoice. test Report PRoDUCt Wattage ResistanCe BefoRe fitting ResistanCe after fitting insulation ResistanCe 500v Pn-e Mat / Cable 1. Mat / Cable 2. Mat / Cable 3. Mat / Cable 4. Mat / Cable 5. Mat / Cable 6. Customer Name: Customer Address: Electrical installation by: Serial number of calibrated test equipment: Underfl oor Heating installation by: Date Signature 10

Professional Cable Kits (TPP) All TPP kits include: twin wire earth screened Thermopads heating cable, programmable digital thermostat with 2 x floor temp probe, adhesive strapping tapes, smart tack spray adhesive and double sided edge tapes. Part Number (W) Cable length(s) Coverage (M²) System Used (Please Tick) Invoice Number TPP115 11.5m 0.7-0.9 TPP140 14m 0.8-1.1 TPP170 17m 1.0-1.3 TPP225 22.5m 1.4-1.7 TPP290 29m 1.7-2.2 TPP350 35m 2.1-2.7 TPP400 40m 2.4-3.1 TPP480 48m 2.9-3.7 TPP560 56m 3.4-4.3 TPP640 64m 3.9-5.0 TPP700 70m 4.3-5.4 TPP760 76m 4.6-5.8 TPP820 82m 4.9-6.3 TPP920 92m 5.4-6.9 TPP1040 104m 6.3-8.0 TPP1140 114m 6.9-8.8 TPP1250 125m 7.6-9.6 TPP1450 145m 8.8-11.2 TPP1600 160m 9.7-12.3 TPP1800 180m 10.9-13.8 TPP2080 104m+104m 12.6-16.0 TPP2280 114m+114m 13.9-17.6 TPP2500 125m+125m 15.2-19.3 TPP2700 145m+125m 16.4-20.8 TPP2900 145m+145m 17.5-22.3 TPP3050 160m+145m 18.2-23.1 TPP3200 160m+160m 19.5-24.5 TPP3400 180m+160m 20.0-25.4 TPP3600 180m+180m 21.8-27.7 TPP3950 125+125+145 24.0-30.0 TPP4350 145+145+145 26.0 33.0 TPP4800 160+160+160 29.0 36.0 11

Ambient Electrical Ltd 01799 524730 info@ambient-elec.co.uk www.ambient-elec.co.uk