SECTION COLUMN COVERS

Similar documents
SECTION METAL COMPOSITE MATERIAL WALL PANELS

Page 1 of 5

Guideline Specifications


SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

VITRABOND Aluminum Composite Panel Façade System Specification Template

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

Alply CLASSIC WALL Architectural Insulated Panel Wall System

Specifications for FL-100 Soffit Panel

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

SECTION EXPANSION CONTROL

A. Access doors and frames are part of an access door and frame allowance.

SPECIFICATIONS: Architectural Aluminum Railings

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

SL150 Guide Specification

1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

by Rollfab Metal Products

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

SECTION IMPACT RESISTANT WALL PROTECTION

SECTION METAL BUILDING SYSTEMS

SECTION ACOUSTICAL PANEL CEILINGS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

SECTION TURBINE VENTILATORS

SECTION MANUFACTURED ROOF EXPANSION JOINTS

DBI-SALA Uni 8 Overhead Horizontal Lifeline Cable System SECTION HORIZONTAL FALL PROTECTION - OVERHEAD CABLE

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

CENTRIA FORMABOND II Metal Composite Wall System

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

Corium Brick Rainscreen System Specifications

CENTRIA EcoScreen Perforated Screen Wall Panels

SECTION DIRECTORIES

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System

ESR ICC Evaluation Service, Inc. Issued November 1, 2003 This report is subject to re-examination in one year.

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

SECTION SECTIONAL OVERHEAD DOORS

VITRABOND Metal Composite Material Façade System Specification Template

EVO ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

SECTION DECORATIVE METAL AND GLASS RAILING

BEARING METAL STUD FRAMING

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

Specification for larson by Alucoil PE Core Aluminum Composite Material (ACM)

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

PRODUCT SPECIFICATIONS

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall

SECTION RESILIENT SHEET FLOORING

Architectural Specifications, Section Phenolic Lockers

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers)

SPECIFICATION SECTION PART 1 GENERAL

SECTION GUTTERS AND DOWNSPOUTS

PROJECT LOCATION SECTION TEXTURED METAL PLATE WALL PANELS

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

REYNOBOND FR DURAGLOSS 5000 ECOCLEAN

A. This Section includes automatic entrance door systems operating as follows: 1. Swinging operation.

A. ASTM C190 - Test Method for Tensile Strength of Hydraulic Cement Mortars

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

GUIDE SPECIFICATIONS CURA ADJUSTABLE REROOF FRAMING SYSTEMS SECTION REROOFING ADJUSTABLE FRAMING SYSTEM

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

Valspar InspireME Coil and Extrusion Product Guide Specification Section Shop-Applied Coatings for Metal

ACOUSTICAL WALL TREATMENT SECTION 09840

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC.

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels.

SECTION ALUMINUM COMPOSITE WALL PANEL SYSTEM

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders

SECTION 9810 ACOUSTICAL SPACE UNITS BAFFLES AND CLOUDS

RSX4 ALUMINUM COMPOSITE RAIN SCREEN PANEL SYSTEM

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

PROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System

SPECIFICATION GUIDELINE

1.1 SECTION INCLUDES A. Insulated Metal and FRP Wall and Ceiling Panels and Related Accessories.

A. Pre-engineered, pre-finished extruded aluminum Pavilions.

SECTION GYPSUM BOARD ASSEMBLIES

A. This Section includes ceilings consisting of acoustical panels and exposed suspension systems.

PH6000. Key Features

TMS 114 XT TECHNICAL MANUAL

TMS 152 / 152T / 152XT TECHNICAL MANUAL

Westgate Entrematic, Parking Security Gates Section OVERHEAD SECURITY GATE Prepared by: Digicon Information Inc. Page 1

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

Metal Roof Panels

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

March 26, 2017 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

(Specifier Note: Aristech Surfaces LLC is the manufacturer of the Avonite brand

SECTION PIPE AND TUBE RAILINGS PART 1- GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY 1.3 PERFORMANCE REQUIREMENTS

G. UNDERWRITERS LABORATORY, INC.: 1. UL 325: Electrical Door, Drapery, Gate, Louver, and Window Operators and Systems

Transcription:

SECTION 05 75 30 COLUMN COVERS USE THIS SECTION WHEN SPECIFYING C.R. LAURENCE ARCHITECTURAL COLUMN COVERS. COLUMN COVERS ARE AVAILABLE IN THREE (3) SYSTEMS; STANDARD WET SYSTEM, DELUXE FULL FRAMED WET SYSTEM, AND PREMIER DRY SYSTEM. COLUMN COVERS ARE AVAILABLE IN TWO (2) PANEL, THREE (3) PANEL, AND FOUR (4) PANEL CONFIGURATIONS, IN ROUND, SQUARE, AND ELLIPTICAL SHAPES, DEPENDING ON DESIGN CRITERIA. COLUMN COVERS ARE AVAILABLE IN ALUMINUM COMPOSITE MATERIAL (ACM), METAL COMPOSITE MATERIAL (MCM), AND SOLID METAL MATERIAL, IN A VARIETY OF COLORS AND FINISHES. THIS SPECIFICATION SECTION IS A MANUFACTURER SPECIFIC PRODUCT SPECIFICATION USING THE PROPRIETARY METHOD OF SPECIFYING APPLICABLE TO PROJECT SPECIFICATIONS AND MASTER GUIDE SPECIFICATIONS. THIS SPECIFICATION SECTION SHOULD BE EDITED TO MEET SPECIFIC PROJECT DESIGN CRITERIA BY A KNOWLEDGEABLE CONSTRUCTION SPECIFIER. OPTIONS ARE SHOWN IN BRACKETS [ ]. CHOOSE OPTIONS THAT MEET DESIGN CRITERIA, AND REMOVE BRACKETS AND UNUSED OPTIONS BEFORE PRINTING. PART 1 GENERAL 1.01 SECTION INCLUDES A. Manufactured architectural column covers. 1.02 RELATED REQUIREMENTS A. Section 05 40 00 - Cold-Formed Metal Framing: Steel angles for attachment to structural column. B. Section 07 90 05 - Joint Sealers. 1.03 REFERENCE STANDARDS A. AAMA 609 & 610-02 - Cleaning and Maintenance Guide for Architecturally Finished Aluminum. B. AAMA 2605 - High Performance Organic Coatings on Architectural Extrusions and Panels. C. ASTM A 36 - Carbon Structural Steel; 2005. D. ASTM A 123 - Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products; 2002. E. ASTM A 153- Zinc Coating (Hot-Dip) on Iron and Steel Hardware; 2005. F. ASTM A 276 - Stainless Steel Bars and Shapes; 2006. G. ASTM A 240 - Stainless Steel Sheet and Plate; 2007. H. ASTM A 480 - General Requirements for Flat-Rolled Stainless and Heat-Resisting Steel Plate, Sheet, and Strip; 2006b. I. ASTM A 666 - Annealed or Cold-Worked Austenitic Stainless Steel Sheet, Strip, Plate, and Flat Bar; 2003. J. ASTM B117 - Standard Practice for Operating Salt Spray (Fog) Apparatus. K. ASTM B 209 - Aluminum and Aluminum-Alloy Sheet and Plate. 10-20-08_CRL / CRL_Column Covers 05 75 30-1 COLUMN COVERS

L. ASTM B 221 - Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes; 2006. M. ASTM C 297 - Standard Test Method for Flatwise Tensile Strength of Sandwich Construction. N. ASTM D 1781 - Standard Test Method for Climbing Drum Peel for Adhesives. O. ASTM D 4145 - Standard Test Method for Coating Flexibility of Prepainted Sheet; 1983 (Reapproved 2002). P. ASTM D 4214 - Standard Test Methods for Evaluating the Degree of Chalking of Exterior Paint Films; 2007. Q. ASTM E 84 - Standard Test Methods for Surface Burning Characteristics of Building Materials; 2008. R. ASTM E 108 - Standard Test Methods for Fire Tests of Roof Coverings. SPECIFIER'S NOTE: ARTICLE BELOW INCLUDES SUBMITTAL OF RELEVANT DATA TO BE FURNISHED BY CONTRACTOR BEFORE, DURING AND AFTER CONSTRUCTION. COORDINATE THIS ARTICLE WITH ARCHITECT'S AND CONTRACTOR'S DUTIES AND RESPONSIBILITIES IN CONDITIONS OF THE CONTRACT AND DIVISION 1 SUBMITTAL PROCEDURES SECTION. 1.04 SUBMITTALS A. Column cover manufacturer qualifications. B. Product Data: Column cover manufacturer's data sheets on each product to be used, including thickness, physical characteristics, and finish, and: 1. Finish manufacturer's data sheet showing physical and performance characteristics. 2. Storage and handling requirements and recommendations. 3. Fabrication instructions and recommendations. 4. Specimen warranty for finish, as specified herein. C. Shop Drawings: Show layout and elevations, dimensions and thickness of column cover material, finishes and textures, connections, details and location of joints, sealants and gaskets, method of anchorage, number of anchors, supports, reinforcements, and accessories. 1. Indicate column cover numbering system if applicable. 2. Differentiate between shop and field fabrication. 3. Indicate substrates and adjacent work with which the column covers must be coordinated. D. Samples: Submit [ ] selection and verification samples of column cover, [ ] inch by [ ] inch in size illustrating finish color, sheen, and texture. E. Installer s Qualifications: Include a minimum of three (3) projects with similar types of exterior [interior] [exterior and interior] column covers, with facility contact information. F. Certificate: Certify that the work results of this section meet or exceed specified requirements. G. Manufacturer's installation instructions. H. Manufacturer's Field Reports: Provide within 48 hours of field review. State what was observed and what changes, if any, were requested or required. I. Maintenance Data: Care of finishes and warranty requirements. J. Executed Warranty: Submit warranty and ensure that forms have been completed in Owner's name and registered with manufacturer. 10-20-08_CRL / CRL_Column Covers 05 75 30-2 COLUMN COVERS

Specifier's note: Article below to include qualifications, prerequisites, standards, limitations, and criteria to establish the requirements for the level of quality for products and workmanship for the work of this section. Coordinate Article with Division 1 Quality Assurance Section. 1.05 QUALITY ASSURANCE A. Field Measurements: Verify actual dimensions by field measurement before fabrication; show recorded measurements on shop drawings. B. Column cover manufacturer qualifications: Company specializing in manufacturing products specified in this section. 1. Approved by ACM [MCM] sheet manufacturer. C. Installer Qualifications: Experienced in performing work of the type specified in this section. 1. With minimum 3 years of documented experience in installation of metal column cover similar to the work of this section. 2. Approved by column cover manufacturer. Specifier's note: Retain paragraph below if mock-up assemblies; erected either on-site, or off-site, are required. Mock-ups can be used to establish standards of quality for workmanship, review of construction sequence/operation, and coordination of work of related sections. Coordinate with Division 1 Quality Control Section; Mock-up requirements. D. Mock-Up: Provide a mock-up for evaluation of fabrication workmanship. 1. Locate on project site [at an off-site location]. 2. Provide panels finished as specified. 3. Mock-up may remain as part of the Work. 1.06 DELIVERY, STORAGE, AND HANDLING A. Deliver products in manufacturer's original, unopened, undamaged containers with identification labels intact. 1. Protect finishes by applying heavy duty removable plastic film during production. 2. Package for protection against transportation damage. 3. Provide markings to identify components consistently with drawings. 4. Exercise care in unloading, storing and installing column covers to prevent bending, warping, twisting and surface damage. B. Store products protected from exposure to harmful weather conditions and at temperature conditions recommended by manufacturer. 1.07 WARRANTY A. See Section 01 78 00 - Closeout Submittals, for additional warranty requirements. B. See manufacturer for additional information on extended warranty periods for high performance coatings. PART 2 PRODUCTS 2.01 MANUFACTURERS A. C.R. Laurence Co,, Inc., P.O. Box 58923, Los Angeles, CA 90058-0923; Tel: (800) 421-6144 or (323) 588-1281 Ext. 7770; Fax: (866) 921-0532 or (323) 584-5226; Email: archmetals@crlaurence.com. 10-20-08_CRL / CRL_Column Covers 05 75 30-3 COLUMN COVERS

B. Substitutions: No substitutions are permitted. 2.02 MANUFACTURED COLUMN COVERS A. Column cover: Standard Wet System [Deluxe Full Framed Wet System] [Premier Dry System] preformed and prefinished architectural column cover; round [square] [elliptical], two panel opposing [three panel staggered] [four panel opposing] [four panel staggered], aluminum composite [metal composite] [solid metal] material, size as indicated on drawings. Specifier's note: Fill in length of column covers in paragraph below. Column covers can be fabricated up to 156 inches in length, after that intermediate seams are required. 16 ga. Stainless Steel: Up to 120 inches in length. 14 ga. Stainless Steel: Up to 144 inches in length. 1/8 inch aluminum: Up to 144 inches in length. 1. Length of column covers [ ] inches. 2. Length of column covers as indicated on Drawings.] Specifier's note: Fill in dimensions of round column covers in paragraph below. Round column covers in 2 panels opposing configuration have a minimum diameter of 14 inches and a maximum diameter of 38 inches; 4 panel opposing configuration have a minimum diameter of 36 inches and a maximum diameter of 78 inches; 3 panel staggered configuration have a minimum diameter of 14 inches and a maximum diameter 58 inches. 3. Size of round column covers [ ] inches. 4. Size of round column covers as indicated on Drawings. Specifier's note: Fill in dimensions of square column covers in paragraph below. Square column covers in 2 panels opposing configuration have a minimum 8 x 8 inches and maximum 30 x 30 inches; 4 panel opposing configuration have a minimum 24 x 24 inches and a maximum 60 x 60 inches; 4 panel staggered have a minimum 24 x 24 inches and a maximum 48 x 48 inches. 5. Size of square column covers [ ] inches. 6. Size of square column covers as indicated on Drawings. Specifier's note: Fill in dimensions of elliptical column covers in paragraph below. Elliptical in 2 panels opposing configuration have a minimum 20 x 10 inches and maximum of 48 x 24 inches; 4 panel opposing configuration have a minimum of 30 x 48 inches and a maximum 96 x 48 inches; 4 panel staggered have a minimum 30 x 48 inches and a maximum 78 x 39 inches. 7. Size of elliptical column cover [ ] inches. 8. Size of elliptical column covers as indicated on Drawings. Specifier's note: Select materials from paragraphs below suited for design requirements. Delete materials that are not used. 2.03 MATERIALS 10-20-08_CRL / CRL_Column Covers 05 75 30-4 COLUMN COVERS

A. Precoated Aluminum Sheet: ASTM B 209, 5052-H32 smooth surface texture; continuous-coil-coated on exposed surfaces with specified finish coating and on panel back with specified panel back coating. 1. Thickness: 1/8 [ ] inch thick. 2. Finish: a. Satin anodized. b. Dark bronze anodized. c. High Performance PVDF coating. Duranar contains 70% Kynar 500 or Hylar 5000 fluoropolymer resin; exceeds the performance requirements of AAMA 2605. d. High performance powder coating. Spraylat Newlar thermosetting powder coating; exceeds the performance requirements of AAMA 2605. Corrosion protection: Meets 4000 hr. salt spray when tested in accordance with ASTM B117. e. Powder coated aluminum. B. Stainless steel 1. 16 ga [ 14 ga] thick cold rolled stainless steel sheet; ASTM A240, type 304 [316]. 2. Finish: a. Hairline finish b. Polished # 8 finish c. Non-directional finish C. Aluminum-faced Composite Material (ACM) [Metal Composite Material (MCM)] Sheet: Two sheets of aluminum [stainless steel] [copper] [titanium with stainless steel backer sheet] sandwiching a solid core of extruded [fire resistive Alpolic/fr] thermoplastic material formed in a continuous process with no glues or adhesives between dissimilar materials; core material free of voids and spaces; no foamed insulation material content. 1. Overall Sheet Thickness: 4 mm [ 3mm thickness available upon request]. 2. Face Sheet: Aluminum alloy 3105 H14, 0.020 inches, minimum [Titanium 0.3 mm and 0.3 mm stainless steel backer sheet]. 3. Panel size: As indicated on Drawings; 4 ft by x 15 ft maximum panel size. 4. Bond strength: 1500 psi (10.3 MPa) minimum when tested in accordance with ASTM C297. 5. Peel Strength: No adhesive failure of the bond between the core and the skin nor cohesive failure of the core itself below 22.4 inch-pound/inch with no degradation in bond performance, when tested in accordance with ASTM D 1781, simulating resistance to panel delamination, after 8 hours of submersion in boiling water and after 21 days of immersion in water at 70 degrees F. 6. Fire performance: Flame spread; 0, maximum; smoke developed;10 maximum; when tested in accordance with ASTM E 84. [Fire resistive Alpolic/fr core has higher flash point and ignition temperature than standard core, and has been tested to UBC 26-9 Intermediate Scale Multi Story Apparatus Test - Passed (4 and 6 mm thickness), and UBC 26-3 Room Corner Test - Passed (4 mm thickness.] 7. Surface flammability (Modified ASTM E108): Passed. 8. Factory Finish: One coat fluoropolymer resin coating, approved by the coating manufacturer for the length of warranty specified for the project, and applied by coil manufacturing facility that specializes in coil applied finishes. Meets or exceeds values expressed in AAMA 2605 for coil coatings. a. Basis of Design: fluoropolymer resin coating as manufactured by. b. Coating Flexibility: Pass ASTM D 4145 minimum 1T-bend, at time of manufacturing. c. Long-Term Performance: Not less than that specified under WARRANTY in PART 1. 9. Color/Texture: As selected from manufacturer's standard color selections below. Custom colors available upon request. a. Aluminum Series: 1) EWS100CBW Composite - Bone White 2) EWS100CCM Composite - Champagne Metallic 3) EWS100CMP Composite - Mica Platinum 4) EWS100CSM Composite - Silver Metallic 10-20-08_CRL / CRL_Column Covers 05 75 30-5 COLUMN COVERS

5) Custom colors available upon request] b. Stone Series: 1) EWS100CBG Composite - Black Granite 2) EWS100CWM Composite - White Marble Exotic c. Metals Series: 1) EWS100CCP Composite - Copper 2) EWS100CBS Composite - Stainless Steel 3) EWS100CT Composite - Titanium 10. ACM [MCM] sheet production tolerances: a. Width: plus or minus 0.04 inch in 3 feet (1mm in 1m). b. Length: plus or minus 0.04 inch in 3 feet (1mm in 1 m). c. Thickness (4 mm sheet): plus or minus 0.008 inch (0.2 mm). d. Bow: Maximum 0.5% length or width. e. Squareness: Maximum 0.2 inch (5.1mm). f. Edges of sheet shall be square and trimmed with no displacement of aluminum sheets or protrusion of core material. Specifier's note: Select from the three (3) paragraphs below for metal framing members based on standard wet seal, deluxe wet seal, or premier dry seal system. For standard wet seal system select the following paragraph. Steel angles for mounting to structural column can be provided by CRL upon request. D. Metal Framing Members: Angles, channels, z-clips, hat-shaped and furring channels, provided under Section 05 40 00 - Cold-Formed Metal Framing. [11 gage galv. steel angles, continuous length full height of column. Select size of angle best suited to size of structural column, and diameter of column cover.] E. Attachment clips: Aluminum extrusions: ASTM B 221, 6063-T6 alloy, with mill finish as recommended by manufacturer. 1. Provide material strength, dimensions, configuration as required to meet the applied loads applied and in compliance with applicable building code. F. Anchors, Clips and Accessories: 1. Stainless steel complying with ASTM A 480/A480M, ASTM A 276 or ASTM A 666. 2. Steel complying with ASTM A 36/A 36M and hot-dipped galvanized to ASTM A153/A153M. G. Fasteners: Self-drilling stainless steel screws as recommended by manufacturer. For deluxe wet seal system select the following paragraph. Steel angles for mounting to structural column can be provided by CRL upon request. H. Metal Framing Members: Angles, channels, z-clips, hat-shaped and furring channels, provided under Section 05 40 00 - Cold-Formed Metal Framing. [11 gage galv. steel angles, continuous length full height of column. Select size of angle best suited to size of structural column, and diameter of column cover.] I. Attachment channel: Aluminum extrusions: ASTM B 221, 6063-T6 alloy, with mill finish as recommended by manufacturer. Full length aluminum extrusion. 1. Provide material strength, dimensions, configuration as required to meet the applied loads 10-20-08_CRL / CRL_Column Covers 05 75 30-6 COLUMN COVERS

applied and in compliance with applicable building code. J. Anchors, Clips and Accessories: 1. Stainless steel complying with ASTM A 480/A480M, ASTM A 276 or ASTM A 666. 2. Steel complying with ASTM A 36/A 36M and hot-dipped galvanized to ASTM A153/A153M. 3. Steel complying with ASTM A 36/A 36M and hot-dipped galvanized to ASTM A123/A123M Coating Grade 10. K. Fasteners: Self-drilling stainless steel screws as recommended by manufacturer. For premier dry seal system select the following paragraph. Steel angles for mounting to structural column can be provided by CRL upon request. L. Metal Framing Members: Angles, channels, z-clips, hat-shaped and furring channels, provided under Section 05 40 00 - Cold-Formed Metal Framing. [11 gage galv. steel angles, continuous length full height of column. Select size of angle best suited to size of structural column, and diameter of column cover.] M. Anchors, Clips and Accessories: As recommended by manufacturer. N. Fasteners: Self-drilling stainless steel screws as recommended by manufacturer. Delete sealants from ACCESSORIES article below when specifying the premier dry seal system 2.04 ACCESSORIES A. Sealants: Specified in Section 07 90 05. Single component, low modulus, neutral cure silicone. Manufacturer's standard type suitable for use with installation of system; non-staining; color as selected. B. Field Touch-up Paint: As recommended by column cover manufacturer. 2.05 FABRICATION A. Form column cover sections true to shape, accurate in size, square, and free from distortion or defects. B. Form pieces in longest practicable lengths. C. Stiffeners are fabricated from same material as column cover. D. Return seams on column covers are bent using press brake machine. E. Curve forming of column covers is by plate roller. F. Form returns at vertical joints to provide uniform reveal as indicated on shop drawings. G. Fabricate column covers to allow for thermal movement without sealant failure, buckling, or other deformation of column cover appearance. Use following paragraph when specifying premier dry seal system only. Delete following paragraph when specifying other other systems. H. Premier dry system: Form seam at vertical joints with keyhole slot and stainless steel shoulder screw attachment to provide a tight (no reveal) dry joint as indicated on shop drawings. 10-20-08_CRL / CRL_Column Covers 05 75 30-7 COLUMN COVERS

PART 3 EXECUTION 3.01 EXAMINATION A. Verify dimensions, tolerances, and interfaces with other work are acceptable for column covers installation. B. Verify substrate on-site to determine that conditions are acceptable for column cover installation in accordance with manufacturers written instructions. C. Notify Architect [Owner] in writing of conditions detrimental to proper and timely completion of work. Do not proceed with erection until unsatisfactory conditions have been corrected. D. Verify that metal framing members specified under related Sections including; angles, channels, attachment clips, or other attachments to structure are installed in accordance with Drawings, shop drawings, and in accordance with column cover manufacturer's installation instructions. 3.02 PREPARATION A. Protect adjacent work areas and finish surfaces from damage during installation. 3.03 INSTALLATION A. Do not install products that are defective, including warped, bowed, dented, and broken members, and members with damaged finishes. B. Comply with instructions and recommendations of column cover manufacturer, as well as with approved shop drawings. C. Fasten column covers to metal framing members; aligned, level, and plumb. D. Use concealed fasteners unless otherwise approved by manufacturer. E. Do not cut, trim, weld, braze, rout, bend, or otherwise form column covers during erection in a manner that would result in damage to finish, decrease structural integrity of column cover, or result in visual imperfections. Return damaged components to manufacturer's fabrication site. F. Separate dissimilar metals; use gasket fasteners, isolation shims, or isolation tape where needed to eliminate possibility of electrolytic action between metals. G. Where joints are designed for field applied sealant, seal joints completely with specified sealant. H. Install square, plumb, straight, and true, accurately fitted, with tight joints and intersections. I. Replace damaged products. 3.04 TOLERANCES A. Maximum Offset From True Alignment Between Adjacent Members Butting or In Line: 1/16 inch. B. Maximum Variation from Plane or Location Indicated on Drawings: 1/8 inch. 3.05 CLEANING A. Remove site cuttings from finish surfaces. B. Clean and wash prefinished surfaces with mild soap and water; rinse with clean water. C. Clean aluminum surfaces in accordance with recommendations found in AAMA 609 and 610. Do not use agressive alkaline, TSP, acid cleaners, or abrasive cleaners on aluminum surfaces. D. Clean stainless steel surfaces with non-abrasive detergents, soap, ammonia and warm water; rinse with clean water. 10-20-08_CRL / CRL_Column Covers 05 75 30-8 COLUMN COVERS

END OF SECTION 10-20-08_CRL / CRL_Column Covers 05 75 30-9 COLUMN COVERS