Wall Louvers (10200)

Similar documents
SPECIFICATION SECTION PART 1 GENERAL

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

ELM6375DX DRAINABLE ADJUSTABLE LOUVER EXTRUDED ALUMINUM

6 Drainable Louver. Update to Louvers Catalog C-1.0. Catalogue Page 2 Page 7. Page LP-13. Submittals Drawing

ESD-635. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)

Corium Brick Rainscreen System Specifications

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

ESD-403. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

SED-501. Sightproof Louver Drainable Blade. Application and Design

EAD-635. Adjustable Louver Drainable Blades. Application and Design. Standard Construction. Options (at additional cost)

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

EME6325D WIND-DRIVEN RAIN RESISTANT STATIONARY LOUVER

EDD-601. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

SPECIFICATIONS: Architectural Aluminum Railings

A. Access doors and frames are part of an access door and frame allowance.

EDK-402. Stationary Louver K Blade. Application and Design. Standard Construction. Options (at additional cost)

ESJ-401RM. Stationary Louver J Blade. Application and Design. Standard Construction. Options (at additional cost)

by Rollfab Metal Products

SECTION EXPANSION CONTROL

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

Guideline Specifications

Specifications for FL-100 Soffit Panel

PROJECT LOCATION SECTION TEXTURED METAL PLATE WALL PANELS

A. This Section includes ceiling- and wall-mounted diffusers, registers, grilles and louvers.

Louvers Selection, Design Considerations and Details Written by Matt Trentham, R.L. Craig Company, Inc.

Page 1 of 5

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

SECTION DIRECTORIES

SECTION SECTIONAL OVERHEAD DOORS

PROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS


Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

A. Pre-engineered, pre-finished extruded aluminum Pavilions.

SECTION DECORATIVE METAL AND GLASS RAILING

Aluminum Component Pipe Railings

1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

VITRABOND Aluminum Composite Panel Façade System Specification Template

SECTION IMPACT RESISTANT WALL PROTECTION

A. This Section includes automatic entrance door systems operating as follows: 1. Swinging operation.

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

TMS 114 XT TECHNICAL MANUAL

T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD)

TMS 152 / 152T / 152XT TECHNICAL MANUAL

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION TURBINE VENTILATORS

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

SECTION MANUFACTURED ROOF EXPANSION JOINTS

Series - 1

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels.

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System

ESU-150. Thin-line Louver Thin-line Blade. Application and Design. Standard Construction. Options (at additional cost)

SECTION METAL BUILDING SYSTEMS

PIPE AND TUBE RAILINGS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

SECTION PIPE AND TUBE RAILINGS PART 1- GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY 1.3 PERFORMANCE REQUIREMENTS

Walkway Covers and Canopies. Architectural & Engineering Catalog. Version 2.0

WESTECK WINDOWS and DOORS

ESF-145. Thin-line Louver Flat Blade. Application and Design. Standard Construction. Options (at additional cost)

CENTRIA FORMABOND II Metal Composite Wall System

Alply CLASSIC WALL Architectural Insulated Panel Wall System

SECTION ALUMINUM RAILINGS

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

PRODUCT SPECIFICATION SERIES 9000 WINDOW WALL THERMALLY BROKEN ALUMINUM CASEMENT / AWNING / FIXED WINDOW

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove

BEARING METAL STUD FRAMING

PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

SECTION GUTTERS AND DOWNSPOUTS

City of Port Orange Adult Activity Center Remodeling SSA Project No Volusia County, Florida October 8, 2009

SECTION GLASS BALUSTRADE RAILING SYSTEMS

CENTRIA MetalWrap Insulated-Composite Backup Panel System with Integrated Windows and Louvers

TerraClad TM General Specifications

SPECIFICATIONS - DETAILED PROVISIONS Section Standards for Aluminum Work C O N T E N T S

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following:

CENTRIA EcoScreen Perforated Screen Wall Panels

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

METAL HANDRAILS AND RAILINGS. A. Properly identified manufacturer's literature, including shop and erection drawings before starting work.

LUX Specifications. Section S - Preformed Steel Siding

Stationary Louvers. Product Type Model Description EDD-401, 601 ESD-202, 403, 435, 603, 635 EDJ-202, 401, 430, 601 EDK-402, 430, 602 ESID-430

ESU-130S. Thin-line Louver Frameless. Application and Design. Standard Construction. Options (at additional cost)

DIVISION 8 OPENINGS SECTION ALUMINUM WINDOWS

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

SWING DOOR SPECIFICATION

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

Door hardware may be specified in whole or in part in this section or in Section Hardware; coordinate requirements.

C S I S E C T I O N STAINLESS STEEL DOORS AND FRAMES SPECIFICATIONS

Transcription:

Wall Louvers 08 90 00 (10200) PART 1 GENERAL SECTION INCLUDES A. Fixed, extruded-aluminum horizontal storm resistant louver RELATED SECTIONS A. Section 05120 - Structural Steel: Supports for penthouses. B. Section 07900 - Joint Sealers: Sealing around perimeter of louvers. C. Section 09900 - Paints and Coatings: Field painting. D. Section 15810 - Ducts: Ductwork attachment to louvers, and blank-off panels. E. Section 15820 - Duct Accessories: Fire/smoke dampers associated with exterior wall louvers. F. Section 15924 - Analog Control Equipment: Actuators for operable louvers. G. Section 15926 - Digital Control Equipment: Actuators for operable louvers. H. Section 15928 - Instruments and Control Equipment: Actuators for operable louvers. REFERENCES A. Air Movement and Control Association International, Inc. B. AMCA Standard 500-L-99 Laboratory Methods of Testing Louvers for Rating 10200-1

C. AMCA Publication 501 Application Manual for Louvers D. The Aluminum Association Incorporated E. Aluminum Standards and Data F. Specifications and Guidelines for Aluminum Structures G. American Society of Civil Engineers a. Minimum Design Loads for Buildings and Other Structures H. American Society for Testing and Materials a. ASTM B209 b. ASTM B211 c. ASTM B221 d. ASTM E90-90 I. Architectural Aluminum Manufacturers Association a. AAMA 800 Voluntary Specifications and Test Methods for Sealants b. AAMA 605.2 Voluntary Specifications for High Performance Organic Coatings on Aluminum Extrusions and Panels. c. AAMA TIR Metal Curtain Wall Fasteners d. AAMA 2605-98 Superior Performing Organic Coatings on Aluminum Extrusions Panel J. Canadian Standards Association a. CAN3-S157-M83 Strength Design in Aluminum b. S136 94 Cold Formed Steel Structural Members SUBMITTALS 10200-2

A. Product Data: a. For each type of product indicated, provide data describing design characteristics, Maximum recommended air velocity, design free area, materials and finishes, and manufacturer's data sheets on each product to be used, including: i. Preparation instructions and recommendations. ii. Storage and handling requirements and recommendations. iii. Installation methods b. For louvers specified to bear AMCA seal, include printed catalog pages showing specified models with appropriate AMCA Certified Ratings Seals. B. Shop Drawings: a. For louvers and accessories: Include plans, elevations, sections, specific details, and connections for all component parts. Show frame and blade profiles, angles, and spacing. C. Samples: For each type of metal finish required. D. Submittal: For louvers indicated to comply with structural performance requirements and design criteria indicated. E. Product Test Reports: Based on tests performed according to AMCA 500-L DELIVERY, STORAGE AND HANDLING A. Delivery: Materials should be delivered to site in manufacturer s original, closed containers sealed packaging, with labels clearly indicating the name of the manufacturer and the type of the material. B. Storage: Materials should be stored indoors in a dry place to be protected against any means of damage. If it was stored outside for any reason, the material must be covered with a weather proof flame resistant sheeting or tarpaulin. C. Handling: Materials should be handled over as recommended by the manufacturer to prevent them from being damaged. Lifting the louver by the heads, sills and blades 10200-3

will result in its damage. The louver sections should only be lifted and carried by the jambs. QUALITY ASSURANCE A. Source Limitations: Obtain louvers and vents from a single manufacturer where indicated to be of same type, design, or factory-applied color finish. B. Structural requirements: Design louvers, including comprehensive engineering analysis by a qualified engineer, using structural performance requirements and design criteria indicated. Provided louvers shall withstand the effects of gravity loads and the specified loads and stresses within limits and under conditions indicated without permanent deformation of louver components, noise or metal fatigue caused by louver blade rattle or flutter, or permanent damage to fasteners and anchors. C. Performance requirements: Provide louvers complying with requirements specified, as demonstrated by testing manufacturer's stock units identical to those provided, except for length and width according to AMCA 500-L. D. Warranty: Provide written warranty to the client ensuring that all products will be free of defective materials or workmanship for a period of two years from the date of delivery. Upon notification of such defects, within the warranty period, necessary repairs to be done at the convenience of the Employer. PART 2 PRODUCTS MANUFACTURERS A. Acceptable Manufacturer: McGill Architectural Products; 1050 Squires Beach Road, Pickering, Ontario, CA L1W 3N8. Tel: (905) 420-0485. Toll free Tel: (888) 624-4557,Fax: (905) 420-4564, Toll free Fax: (888) 624-4558.Website: www.mcgillarchitectural.com. E-mail: sales@mcgillarchitectural.com. MATERIALS A. Aluminum Extrusions: ASTM B 221M, Alloy 6063-T5, 6063-T6 or 6061-T6. 10200-4

B. Aluminum Sheet: ASTM B3209M, Alloy 1100, 3003 or 5005 with temper as required for forming. C. Fasteners: Use types and sizes to suit unit installation conditions. D. For fastening aluminum, use aluminum or 300 series stainless-steel fasteners. FABRICATION A. Fabricate frames, including integral sills, to fit in openings of sizes indicated, with allowances made for fabrication and installation tolerances, adjoining material tolerances, and perimeter sealant joints. B. Use stainless steel or aluminum mechanical fasteners for assembling louvers. C. Join frame members to each other and to fixed louver blades with threaded fasteners or concealed fillet welds as per the manufacturer s standards unless otherwise indicated. D. Provide louvers along with screens and any other accessories as indicated in the drawings which should include the items required for complete assembly such as structural supports, anchorage, etc. LOUVER MODEL DESCRIPTION A. Louvers General SPECS: Factory fabricated and assembled; AMCA tested under AMCA 500-L. B. Wind Load Resistance: Design to resist positive and negative wind load of psf ( kpa) without damage or permanent deformation. C. Blades: One piece extrusions with reinforcing bosses, supported and lined up with heavy-gage extruded aluminum blade braces, positively interlocked to each blade and mechanically secured to structure by aluminum and stainless steel fastenings. D. Mullions: Coordinated to match louvers. E. Screens: Provide insect screens/bird screens at intake louvers and bird screens at exhaust louvers. 10200-5

F. Where louver exceeds manufacturer's recommended unsupported width or height, concealed, provide back-of-louver structural supports consisting of minimum 2 inch by 2 inch by 1/4 inch (50 mm by 50 mm by 6 mm) aluminum angles, designed to resist specified wind loads; location of angles coordinated to suit penetrations of mechanical air systems. G. Exposed edges and ends of metal dressed smooth, free from sharp edges. H. Exposed connections and joints constructed to exclude water. I. For horizontal louver blades butt jointed with expansion allowance, provide concealed method of aligning blades of adjacent panels so that blades appear to be continuous without any face frame. J. For louvers immediately adjacent to existing louvers, match style of louver blades and line up blades with existing blades. K. Louvers Detailed SPECS: Fixed Extruded Aluminum Horizontal storm resistant Louver Basis-of-Design Product: McGill louvers; Model RSR-4H McGill Rain Storm Resistant series; extruded aluminum construction; frame with channel profile; corner joints mitered and mechanically fastened, with continuous recessed caulking channel each side; intermediate mullions matching frame; gutters to drain rain water to jamb and mullion downspouts; rated for an air performance and water penetration maintained effectiveness rate of 0.99 when tested in accordance with AMCA 500-L. a. Louver Depth: 4 inches (102 mm) b. Blade Profile: Horizontal Multi Drainable blade with front gutter for water diversion to jambs c. Frame and Blade Nominal Thickness: Not less than 0.081 inch (2 mm) for frames and 0.06 inch (1.52 mm) for blades. d. Louver Performance Ratings according to AMCA 500-L standards: i. Free Area: Not less than 7.53 sq. ft. (0.70 sq. m) for 48-inch- (1219.2- mm-) wide by 48-inch- (1219.2-mm-) high louver. ii. Water Penetration Effectiveness (Classification) with 29mph wind velocity @ 3in/hr rainfall rate: 99.2% (CLASS A) 10200-6

iii. iv. Maximum recommended intake core velocity: 387 fpm (2 m/s). Intake pressure drop at maximum intake core velocity: 42 pa. e. Air Performance: i. Discharge loss coefficient (Intake and Exhaust) C d= 0.24 ii. Discharge loss coefficient Classification Class 3 LOUVER FINISHES A. General: Comply with NAAMM s Metal Finishes Manual for Architectural and Metal Products for recommendations for applying and designating finishes. Pre-treat aluminum and apply primer and finish coats to exposed metal surfaces in strict accordance with the manufacturer s written instructions. Remove visible scratches and blemishes from exposed surfaces upon completing the finishing process. B. Powder Coating: 1.5 to 3 mil. thick full strength 100% resin Fluoropolymer coating with zero VOC s emission into the facility of application. This coating meets the requirements of AAMA 2605 specification Voluntary Specification for High Performance Organic Coatings on Architectural extrusions and Panels. The super durable powder coating is covered by 20 years limited warranty against failure or excessive fading of the Fluoropolymer Powder Coat finish from the date of material shipment. C. High-Performance Organic Finish: Two-coat fluoropolymer finish system complying with AAMA 2604 and containing not less than 70 percent PVDF resin by weight in color coat. A minimum of 1.4 mil (0.035mm) thickness of the resin has to be applied on the louver. The aluminum surface shall be cleaned, etched and given a chromate conversion pre-treatment before applying the coat in a continuous operation in the manufacturer s plant. The Kynar coating is covered by 20 years limited warranty against failure or excessive fading of the applied finish from the date of material shipment. D. High-Performance Organic Finish: Three-coat fluoropolymer finish system complying with AAMA 2604 and containing not less than 70 percent PVDF resin by weight in color coat. A minimum of 1.0 mil (0.025mm) thickness of the resin has to be applied on the louver. The aluminum surface shall be cleaned, etched and given a chromate conversion pre-treatment before applying the coat in a continuous operation in the manufacturer s plant. The Kynar coating is covered by 20 years limited warranty 10200-7

against failure or excessive fading of the applied finish from the date of material shipment. E. Anodize Finish (Clear or Bronze) One hour 215R1 Architectural Class I anodic coating has to be applied on the louver and tested in accordance with ASTM B244-68 standard. a. Class I Clear Anodized Finish (.0007 ) b. Class II Clear Anodized Finish (.0004 ) c. Clear Anodized Finish Two Stage Bronze Color- Light, Medium, Dark, Champagne. F. Primer: Zinc chromate, alkyd type; dry film thickness of 25 micrometers; field welds spot primed after roughness and irregularities removed by grinding and cleaning with wire brush. G. Color and Gloss: As selected by Architect from manufacturer s full range. LOUVER ACCESSORIES A. Bird Screens: Unless otherwise specified, louvers exteriors to be furnished with (18mm x 36mm) diamond cell flattened and expanded aluminum mesh secured by 1.4 mm thick extruded aluminum frame with mitered corners and corner locks. The screen frame has to be of same kind and form of metal as indicated for louver to which screens are attached. Screens to be provided with reinforced corners; removable, screw attached; installed on inside face of louver frame. B. Insect Screens: Unless otherwise specified, louvers exteriors to be furnished with stainless steel insect mesh having (1.4mm x 1.4mm) square cells of 0.23 mm thickness secured by 1.4 mm thick extruded aluminum frame with mitered corners and corner locks. The screen frame has to be of same kind and form of metal as indicated for louver to which screens are attached. Screens to be provided with reinforced corners; removable, screw attached; installed on inside face of louver frame. C. Blank off panels: 10200-8

2 inch (51 mm) thick insulated sandwich panel; 0.06 inch (1.5 mm) thick aluminum sheets with core of 4.0 pound per cu ft (64.0 kg per cubic m) density mineral fiber rigid insulation; provide in all non-active areas of louvers. a. Provide channel shaped aluminum closures to conceal core materials at cut-outs. b. Finish: To match louver. c. Panel perimeter to be mitered at the corners, and finished to match the louver. D. Blank-Off Sheets: Same material as louver, non-insulated sheets. E. Sills: To be minimum 0.06 inch (1.27 mm) thick aluminum. Formed back edge turned up at underside of louver sill sections. Louvers with Jambs Designed to Drain Water: Extend sill under entire frame section. Other Louvers: Locate turned up back edge under bottom frame member. F. Fasteners and Anchors: For Aluminum: Series 300 or 400 stainless steel. For Steel Exposed to Weather: Series 300 stainless steel. For Steel Not Exposed to Weather: Hot-dipped galvanized or cadmium plated. a. Flashings: Same material as louver frame, formed to required shape, single length in one piece per location. b. Sealant: As specified in Section 07900. PART 3 EXECUTION EXAMINATION A. Examine openings to receive the louvers. Notify the client of conditions that would adversely affect the installation or subsequent utilization of the louvers. Do not proceed with installation until any unsatisfactory conditions are corrected. INSTALLATION AND PROTECTION: A. Comply with manufacturer s written instructions. 10200-9

B. Install louvers level and plumb, true to dimensions, and free from distortion or defects detrimental to appearance and performance; plumb louvers within a tolerance of 1:175. C. Install flashings and align louver assembly to ensure moisture shed from flashings and diversion of moisture to exterior. D. Secure louver frames in openings with concealed fasteners. E. Provide adequate reinforcing and anchorage to ensure a rigid installation. F. Install perimeter sealant and backing rod in accordance with Section 07900; where sills are integral, set in two continuous beads of sealant. G. Do not install damaged components. H. Verify dimensions of supporting structure by taking accurate field measurements at the site so that the work will be accurately designed, fabricated and fitted to the structure. I. Erection Tolerances: Follow the manufacturer s installation guide and architectural drawings before anchoring louvers to the substructure. J. Use anchorage fasteners where possible. Provide brass or lead washers fitted to screws where required to protect metal surfaces and to make a weather-tight connection. K. Provide perimeter reveals and openings of uniform width for sealants and joint fillers, as indicated. L. Cut and trim component parts during erection only after getting the manufacturer s approval. M. Do not erect deformed or damaged members. Instead, repair any damaged finishes so no evidence remains of corrective work. Return items that cannot be refinished in the field to the factory and refinish entire unit or provide new units. N. Protect galvanized and nonferrous-metal surfaces that will be in contact with concrete, masonry, or dissimilar metals from corrosion and galvanic action by applying a protection tape as specified or by installing nonconductive spacers as recommended by the manufacturer. ADJUSTING AND CLEANING: 10200-10

A. Strip protective finish coverings. B. Fingerprints, trademarks, labels and dirt accumulated on the exposed surface of the louver during installation to be removed immediately with water and a mild soap and detergent that is not harmful to the material finish. Thoroughly, rinse surfaces then dry them. C. Repair and restore minor damaged surfaces as directed by the manufacturer so no evidence remains of corrective work. D. Install louver assembly in accordance with manufacturer's instructions. E. Install louvers level and plumb, true to dimensions, and free from distortion or defects detrimental to appearance and performance; plumb louvers within a tolerance of 1:175. F. Install flashings and align louver assembly to ensure moisture shed from flashings and diversion of moisture to exterior. G. Secure louver frames in openings with concealed fasteners. H. Provide adequate reinforcing and anchorage to ensure a rigid installation. I. Install perimeter sealant and backing rod in accordance with Section 07900; where sills are integral, set in two continuous beads of sealant. J. Coat all aluminum surfaces in contact with cement, concrete, masonry, or dissimilar metals with heavy coat of non-staining alkali resistant bituminous paint. END OF SECTION 10200-11