AccuSEQ v2.1 Real-Time PCR Detection and Analysis Software

Similar documents
quantitate host cell DNA with high sensitivity and throughput resdnaseq Host Cell DNA Quantitation Systems: CHO, E.

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

ICP Expert software. Technical Overview. Introduction

Data Analysis on the ABI PRISM 7700 Sequence Detection System: Setting Baselines and Thresholds. Overview. Data Analysis Tutorial

Thermo Scientific SkanIt software for microplate readers. Simplified data acquisition and analysis

Applied Biosystems 7500 Fast, 7500 and 7300 Real-Time PCR Systems

Software manual. Thermo Scientific PathoProof Norden Lab Studio Instructions for use

QUANLYNX APPLICATION MANAGER

TaqPath ProAmp Master Mixes

Touchscreen (standalone capabilities, PIN-protected user accounts, and dye calibration/rnasep functionality)

QuantStudio 3D Digital PCR System

Plexor HY System for the Applied Biosystems 7500 and 7500 FAST Real-Time PCR Systems

APE SOFTWARE TOOLS FOR MANAGEMENT SYSTEMS. Calibration Control. Calibration Management Software

User s Manual. esims Web. Synthes Information Management Suite.

Applied Biosystems TaqMan Array Microfluidic Cards

PCR Array FAQ s. PCR Arrays: Placing an order

QuantStudio Dx Real-Time PCR Instrument

PERFORMANCE MADE EASY REAL-TIME PCR

Software manual. Thermo Scientific PathoProof Norden Lab Mastitis Studio Software Instructions for use

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

Relative Quantification (Mono-Color) Unknown samples (purified total RNA, mrna or cdna or genomic DNA)

Procedure for DNA Quantitation with Quantifiler Duo

Proficiency Testing Program User Guide

Administrator Quick Reference Virtual TimeClock 18 Pro Edition

Custom dye calibration for StepOne and StepOnePlus Real-Time PCR Systems

ProteinSEQ Protein A Quantification Kit


Administrator Quick Reference Virtual TimeClock 15 Network Edition

RT 2 Profiler PCR Array: Web-based data analysis tutorial

High Cross-Platform Genotyping Concordance of Axiom High-Density Microarrays and Eureka Low-Density Targeted NGS Assays

Ion S5 and Ion S5 XL Systems

I.QC (quality control of your qpcr)

Minimise risk. Maximise competitive edge.

Lytec Features Evolution Matrix

MyiQ Single-Color Real-Time PCR Detection System

For Demonstrations: Automatic Data Collection So Simple The Graphs Just Appear

OpenLAB CDS ChemStation Edition C Tips and Tricks for GC Users

User Manual. NGS Library qpcr Quantification Kit (Illumina compatible)

SeqStudio Genetic Analyzer

QIAGEN Supplementary Protocol

Applied Biosystems Real-Time PCR Rapid Assay Development Guidelines

TaqMan Advanced mirna Assays

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

Introducing a new generation of affordable choices from the leader in real-time PCR. Applied Biosystems 7500 Fast Real-Time PCR System

Procedure for GeneMapper ID-X for Casework

Software. Version Code TP700/TP760. Quick Reference TAKARA BIO INC.

General Business Accounting System

TC10. Piecework for Payroll & TimeCard TC-1010

Solutions Implementation Guide

QUANTITATIVE RT-PCR PROTOCOL (SYBR Green I) (Last Revised: April, 2007)

HYPERION SYSTEM 9 PLANNING

Thermo Scientific Qtegra Intelligent Scientific Data Solution. Delivering quality. Driving productivity

Same TaqMan Assay quality, new format

Risk Management User Guide

User Bulletin. Veriti 96-Well Thermal Cycler AmpFlSTR Kit Validation. Overview

Efficient qpcr Setup Without Cross Contamination Using the epmotion Family of Automated Liquid Handling Systems

Create a Planned Run. Using the Ion AmpliSeq Pharmacogenomics Research Panel Plugin USER BULLETIN. Publication Number MAN Revision A.

Copy number standard curve. for absolute quantification by real-time PCR

Authenticating human cell lines using the Identifiler kits and capillary electrophoresis platforms

SeCore SBT Sequence Based Typing

UNIFI: The user environment Ken Eglinton Nordic User Training, September 2013

Zebra s Repair Order Portal for Partners COURSE CODE: RPE01

Applied Biosystems 7900HT Fast Real-Time PCR System. Performing Fast Gene Quantitation with 384-Well Plates DRAFT

Application Note Detecting low copy numbers. Introduction. Methods A08-005B

INTRODUCTION... 1 DCAA REQUIREMENTS... 2 COMPLIANCE SETUP...

Troubleshooting of Real Time PCR Ameer Effat M. Elfarash

Type-2 Study. Measurement system analysis in destra, version 11

New Features in Primavera Portfolio Management 15.1

NetSuite OpenAir/NetSuite Connector Guide April

M. tuberculosis_mpb64/is611. genesig Advanced Kit. 150 tests. Primerdesign Ltd. For general laboratory and research use only

SCUtils WorkItem Scheduler Guide Solution for Microsoft System Center 2012 Service Manager

TaqMan SNP Genotyping Assays

myturf Fleet Management System Fleet Management Maintain your Equipment Maintain your Budget

FLEETMATE. Overview. Work Order Features. CUSTOMER GUIDE: Work Orders

How to view Results with Scaffold. Proteomics Shared Resource

Featuring Analyst software under Windows NT for enhanced performance and ease of use. API 150EX. LC/MS System

Best practice PDM Anders Bank Petersen

Omnia Assay Setup Guide on the Thermo Scientific Varioskan Flash Multimode Reader

See what s really in your sample

STAFF ATTENDANCE MADE EASY Workforce Management Solutions

Editing an Existing Account on an Invoice Payment Creating a New Account on an Invoice Payment... 47

NovoCyte Flow Cytometer

Contents OVERVIEW... 3

Absolute Human Telomere Length Quantification qpcr Assay Kit (AHTLQ) Catalog # reactions

Guide to using the Bio Rad CFX96 Real Time PCR Machine

GeXP Quantitative Analysis Method. A Tutorial

Sus scrofa Pig genesig Speciation Kit

, Pacific Timesheet. Timesheet Help.

Agilent s Mx3000P and Mx3005P

TECHNICAL MANUAL. ProNex DNA QC Assay. for Use on the Bio-Rad CFX96 Touch Real-Time. PCR Detection System

Useful P6 EPPM Terms Security Configuration Process in P6 EPPM Defining Global Security Profiles in P6 EPPM... 19

Mycobacterium Tuberculosis

AppExchange Packaging Guide

This Company features:

Inventory Item Unit Cost by Line in Order Entry SO-1381

Invoice Manager Admin Guide Basware P2P 17.3

Gadus morhua Cod speciation kit. genesig Easy Kit. for use on the genesig q reactions. Primerdesign Ltd

Bacteriophage MS2. genesig Standard Kit. Phage MS2 genome. 150 tests. Primerdesign Ltd. For general laboratory and research use only

AmoyDx TM JAK2 V617F Mutation Detection Kit

Product selection guide Ion S5 and Ion S5 XL Systems

Transcription:

DATA SHEET AccuSEQ Real-Time PCR Detection and Analysis Software AccuSEQ v2.1 Real-Time PCR Detection and Analysis Software Introduction Automated presence or absence calls for Applied Biosystems MycoSEQ Mycoplasma Detection Kit Automated volume calculations and optimized plate layout for the MycoSEQ system Accurate quantitation with Applied Biosystems resdnaseq Host Cell DNA Quantitation System Nonlinear fitting for Applied Biosystems ProteinSEQ CHO Host Cell Protein Quantification Kit and Protein Quantitation Systems Built-in calculator for dilution adjustment Built-in calculator for efficiency and recovery Quality flags Windows 7 64-bit supported Applied Biosystems AccuSEQ v2.1 Real-Time PCR Detection and Analysis Software is a full-featured software package that supports both routine qpcr assays and the unique needs of analytical testing for contaminants and impurities. AccuSEQ Real-Time PCR Detection and Analysis Software is the software component of an integrated workflow for the SEQ family of impurity and contaminant tests, including the MycoSEQ system, the resdnaseq system, and the ProteinSEQ protein quantitation systems. Automated analysis tools enable one-click processing of MycoSEQ Mycoplasma Detection assay data, capable of delivering a presence or absence call within seconds of data collection being completed. Nonlinear curve fitting enables rapid and easy analysis of ProteinSEQ protein quantitation systems data without the hassle of multiple exporting steps and reliance on third-party software. Next-generation algorithms help deliver accurate quantitation data for the resdnaseq Host Cell DNA Quantitation System. Designed to work Figure 1. Summary of results using the MycoSEQ Mycoplasma Detection assay. The plate contains wells with present, absent, and inconclusive calls, as well as a summary of results. with the Applied Biosystems 7500 Fast Real-Time PCR instrument, the software includes security, audit, and electronic signature capabilities. Automated presence or absence calls for mycoplasma detection Advanced algorithms built in to the AccuSEQ Real-Time PCR Software automate the analysis of presence or absence calls for the MycoSEQ Mycoplasma Detection assay. Developed in tandem with the MycoSEQ Mycoplasma Detection assay, AccuSEQ software generates calls based on the T m, derivative value, and the C t values of the test sample and inhibition control (Figure 1). Factory defaults provide robust data analysis parameters for the MycoSEQ Mycoplasma Detection assay. With the appropriate permissions, call settings may also be modified to meet the specifications of individual laboratories.

For in-depth data review, the AccuSEQ Real-Time PCR Detection and Analysis Software offers easy-to-use manual review tools, including a complete table of all T m, derivative value, and C t values, as well as amplification, multicomponent, and raw data plots. The AccuSEQ mycoplasma SEQ experiment workflow provides a suggested plate layout, a reaction setup worksheet and plate layout diagram, a set of preloaded thermal cycling settings, and a summary of results and detailed reports that can be printed and saved as *.pdf, *.html, *.ppt, and *.xls files. Residual DNA quantitation Using its custom experiment mode, AccuSEQ Real- Time PCR Software supports experimental setup, data collection, and data analysis for the Applied Biosystems resdnaseq CHO, human, E. coli, Vero, Pichia pastoris, NS0, and MDCK kits. The custom mode guides the user through the experiment and plate setup, and provides easy-to-use tools for defining and setting up standards, controls, and unknowns. The user enters the number of concentrations for the standard curve, replicates, starting quantity, and serial dilution factor, allowing the software to automatically set up the standard curve. Figure 2. Standard curve and back-calculated values for a resdna SEQ experiment. The plot includes a linear fit of the standards (red), the R 2 value, and the efficiency value. The tables display back-calculated values for both the individual data points and the mean of the replicate group. Values for dilution factors of unknowns are entered during setup and then used to auto-calculate the dilutionadjusted result for each unknown. Together with the R 2 parameter and back-calculation of %CV values, the results help evaluate the quality of each point on the standard curve (Figure 2). A customized template for the family of resdnaseq Host Cell DNA Quantitation assays loads default values for assay setup and PCR. After the run is complete, the values for quantity, quantity mean, dilution adjusted quantity, standard deviation, and %CV are provided in a table format that can be exported in *.pdf, *.xls, and *.txt formats. Integration with the ProteinSEQ Protein Quantitation Systems Using its custom experiment mode, AccuSEQ Real- Time PCR Software provides integration features for the ProteinSEQ protein quantitation systems. The custom mode guides the user through the experiment and plate setup, and provides easy-to-use tools for defining and setting up standards, controls, and unknowns. The user enters the number of concentrations for the standard curve, replicates, starting quantity, and serial dilution factor allowing the software to automatically set up the Figure 3. Summary of results using the ProteinSEQ CHO Host Cell Protein Quantitation assay. The left panel shows a nonlinear standard curve generated using serial dilutions of CHO host cell protein standard (red squares); blue squares represent unknown samples. The right panel shows the plate map of standards and unknowns. standard curve. Values for dilution factors of unknowns are entered during setup and then used to auto-calculate the dilution-adjusted quantitation result during analysis. For spike recovery and efficiency assays, the user can enter the spike input concentration and reference information during setup, which enables auto-calculation of both the reference-corrected concentration and the final percent recovery or efficiency. Nonlinear curve fitting (4PL and 5PL) with weighting functions allow analysis of sigmoidal standard curves directly within AccuSEQ Real-Time PCR Software, removing the need to perform multiple import or export tasks or purchase and validate third-party software (Figure 3). Back-calculation values and %CV values are automatically calculated for each point on the standard curve to help assess fit quality.

A customized template for the ProteinSEQ Host Cell Protein Quantitation and ProteinSEQ protein quantitation systems loads default values for assay setup and PCR. After the run is complete, values for the quantity, quantity mean, standard deviation, %CV, dilution adjusted quantity, reference adjusted quantity, and percent spike recovery are calculated with one mouse click, and displayed in a table format that can be exported in *.pdf, *.xls, and *.txt formats. Feature comparison Feature v1.0 v1.0.1 v2.0 v.2.1 High resolution melting (HRM) analysis (optional) Gene expression analysis SNP genotyping Quantitation relative Presence or absence Quantitation standard curve Melt curve SAE (basic) SAE (advanced) Automated MycoSEQ mycoplasma assay calls Quality summary Accurate resdnaseq Host Cell DNA assay analysis Instrument maintenance manager Editable MycoSEQ assay call settings Nonlinear curve fitting (4PL/5PL) In-table commenting Editable high background threshold Weighting functions for nonlinear fitting Auto-calculate replicate mean Auto-calculate replicate %CV Auto-calculate back-calculation values Simplified MycoSEQ call structure Editable number of inhibition controls for mycoplasma assays Editable peak threshold for mycoplasma assays Report DV values in all tables Control of quality check flags Result table filters Dedicated settings for MycoSEQ discriminatory positive control Windows 764-bit support Prevent file overwriting (security) Operation in Windows environment lacking deletion privileges (security) Automatic creation of backup file (security) Auto-calculate dilution adjustment Auto-calculate spike recovery Administrator/lab defaults for MycoSEQ call settings Four decimal places for all table values <1 = Feature = Key feature

Security, audit, and signature capabilities The AccuSEQ Real-Time PCR Software security, audit, and electronic signature (SAE) manager (Figure 4) includes options that let you easily manage your security settings. These include: Security user name and password restrictions, as well as security policies such as password expiration and user account suspension. Audit selection of an audit mode (prompt or silent), management of audit reasons, and sorting and printing of audit records at the experiment and system levels. Electronic signature selection of an electronic signature mode (enable or disable), on-demand electronic signature, electronic signature settings, number of electronic signatures required, and electronic signature actions (review, approve, or sign off) (Figure 5). Figure 4. AccuSEQ software audit view. Features Number of decimal places reported the number of decimal places reported in the results table have been extended, increasing your ability to assess small values in the results table. Values less than one are reported to the ten thousandths (4 decimal places). Values greater than one are reported to the hundreds (two decimal places). No file overwrite file overwrite is not permitted, enhancing the security of your data. File A can be edited and saved as File A where changes are recorded in the electronic record. File B, however, is not allowed to overwrite File A. Figure 5. AccuSEQ software electronic signature actions. Compatible with Windows No Deletion permission operation is compatible with a Windows environment in which the user lacks deletion privileges, providing increased data security. Quality summary in rare cases where there may be inconclusive or unexpected results, AccuSEQ software generates a quality summary view that provides detailed call assessments and troubleshooting suggestions (Figure 6). Figure 6. AccuSEQ software quality summary.

Backup file copy at the end of each run, a backup copy of the result file is saved in the unlikely case of accidental data loss. The file is stored in the folder C:\Applied Biosystems\AccuSEQ\experiments_temp. This backup copy is completely independent of the user copy and is therefore left unchanged when the user copy is edited. Administrator MycoSEQ call defaults AccuSEQ Real-Time PCR Detection and Analysis Software includes robust factory default values for making automated calls using C t, derivative value, and T m data for the MycoSEQ Mycoplasma Detection Kit. The administrator can now save Administrator Analysis Settings as the default analysis parameters for all users. The factory default call settings are always stored and can be recalled using the same menu. Because Administrator Defaults have priority over Factory Defaults, an administrator can easily set defaults for the entire lab. Users can access this feature under MycoSEQ Module > Analysis (top menu) > Analysis Settings. Percent recovery calculator calculation of percent recovery during spiking experiments involves several different values: the spike concentration, the measured concentration, the reference concentration, and the reference-corrected concentration. AccuSEQ Real-Time PCR Detection and Analysis Software now accepts all spike information during the experimental setup and, with one click, delivers the final percent recovery value in the results table providing a fast and easy analysis without error-prone export and/or copy-paste steps (percent recovery = 100 x [spike input/reference adjusted], where reference adjusted = quantity mean reference mean). Report organized by topic the report has been reorganized into distinct sections for easier readability. Sections include: Experiment summary Results summary Plate layout Amplification plot Standard curves Results table (by well) Results table standards Results table unknowns Results table spikes QC summary Windows 7 64-bit AccuSEQ Real-Time PCR Detection and Analysis Software now supports the Windows 7 64- bit operating system. Dilution-adjusted calculator many protein samples are diluted during preparation and this dilution factor is multiplied by the measured quantity to determine the analyte concentration in the starting sample. AccuSEQ Real-Time PCR Detection and Analysis Software now accepts the dilution factor as input during setup and automatically delivers the dilution-adjusted quantity in the results table, removing the need to copy, paste, or export data (dilution adjusted = quantity mean x dilution factor).

Ordering information Description Cat. No. AccuSEQ Real-Time PCR Detection Software v2.0 4443420 Includes AccuSEQ v2.1 software as a downloadable update AccuSEQ Real-Time PCR Detection Software v2.1 30-day demo 4444868 Includes AccuSEQ v2.1 software as a downloadable update 7500 Fast Real-Time PCR System (with laptop computer) 4365464 Find out more at thermofisher.com/accuseq For Research Use Only. Not for use in diagnostic procedures. 2016 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. Windows is a trademark of Microsoft Corporation. COL11420 0616