Meeting the challenges of medical device packaging

Similar documents
ISO Part 1 and Part 2 Compliance Requirements. Cathriona O Neill

ISO INTERNATIONAL STANDARD

ISO How to translate into action Sterile container systems

European Packaging Regulations What to expect from a notified body audit of your packaging

HEAD. 5. Materials and preformed sterile barrier systems Microbial barrier properties...10

AIOS ASSOCIAZIONE ITALIANA OPERATORI SANITARI ADDETTI ALLA STERILIZZAZIONE

Sterile Barrier System: Common Failure Modes & Design Recommendations

WHITE PAPER March 2015

Packaging Systems for Central Service Operations

ISO INTERNATIONAL STANDARD

PREVENTING WOUND INFECTION BEGINS BEFORE THE PATIENT

10 Things You Should Do Before You Validate Your Next Package

ISO INTERNATIONAL STANDARD

Sample Size Rationale For Medical Device Package Validation

Requirements of validation of packaging systems and sterility assurance

Packaging for terminally sterilized medical devices. Part 1: Requirements for materials, sterile barrier systems and packaging systems

POSITION PAPER Moving from the MDD to the MDR

PACKAGING REQUIREMENTS AND QUALITY ASSURANCE PROVISIONS FOR MIL-DTL-32541, PIZZA SLICE, SHELF STABLE, FOR OPERATIONAL RATIONS

Initiation of Validation

FlexAct BT (Bag Tester) Flexboy 2D November, 2015

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

GLOBAL QUALITY SOLUTIONS PACKAGE INTEGRITY SEAL INTEGRITY LEAK DETECTION

Air and Vapor Barrier 3015

PRODUCT CATALOGUE. for gke Steri-Record and gke Clean-Record Chemical indicators, PCDs and accessories for cleaning and sterilization

Thermoforming packaging machine R 145 with MULTIVAC Clean Design. Maximum process reliability and cleanroom suitability

Steam Sterilization Monitoring in the New CSA Standard (Z )

Efficient Validation Strategies and VMPs

Product Information. Polyester Felt Cured-In-Place Pipe (CIPP) Lining Tube

Medline Gemini Sterilization Wrap. Test Studies

Review Validation of aseptic processes for pharmaceuticals

CALIBRATION AND QUALIFICATION OF EQUIPMENTS IN THE PHARMACEUTICAL INDUSTRY: EMPHASIS ON RADIOPHARMACEUTICALS PRODUCTION

PQS performance specification

PDA: A Global. Association. Proposed Revisions to USP <1207> STERILE PRODUCT -

A. Source Limitations: Obtain each type of building insulation through one source.

Tetra Pak Aseptic Package Integrity. Mike Bolstridge Director Product Quality and Safety IFTPS March 2012

Customer Packaging Guidelines

Medical and Pharmaceutical Packaging Styles

gke Steri-Record Testsets and PCDs for validation, process and batch monitoring of sterilization processes

GUIDELINES FOR THE PACKAGING AND STORAGE OF PESTICIDES FOOD AND AGRICULTURE ORGANIZATION OF THE UNITED NATIONS

Your Sterile Processing Partner. Duraholder IPS

Packaging for Sterilization

Annex Draft Annex

GMP On Site Series. GMP Essentials

DUPONT TECHNICAL REFERENCE GUIDE FOR MEDICAL AND PHARMACEUTICAL PACKAGING

Doc No.: MHD 12(0333)/ISO :2006 TITLE: Sterilization of health care products Biological indicators Part 1: General requirements

ISO INTERNATIONAL STANDARD

Quick Reference Guide. Also contains. Key Selling Points Including Advantages vs. Competition

Guidelines for Process Validation of Pharmaceutical Dosage Forms

Performance Qualification Protocol Prepared March 2008

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

TUFF-TAC TM BRIDGE MEMBRANE INSTALLATION GUIDE

Abcite 585 EF. Technical Data and Application Guide. Product description. Typical applications. Product range. Product certifications.

Temperature mapping and autoclave validation specialists

ISO/TC 198. Secretariat: ANSI

QUALITY ASSURANCE IN AN MDRD

Equipment Qualification Ensure Fit for Intended Use. IVT Amsterdam Conference Mary Sexton. 19 Mar 2015

Validation of Sterilizing Grade Filters

A new method for protecting construction joints and through-penetrations from fire, water, smoke and sound.

Aseptic Process Validation

Construction. Tricosal Waterstops - Tricomer. Waterstops for joint sealing in watertight concrete construction according to DIN and DIN

ITEM 458 WATERPROOFING FOR STRUCTURES

Questar ThermWise Duct Technical Specifications

We ve built a STRONG CASE. for changing the way you sterilize. Reusable Sterilization Container System

Packaging Solutions For Small Parcel Shipping For Over 50 Years

Sarnavap 1000E is an unsupported vapour control layer based on PE-LD (Low Density Polyethylen).

Nothing Protects Better Than The Original

Annex A2. Guidance on Process Validation Scheme for Aseptically Processed Products

ACOUSTICAL WALL TREATMENT SECTION 09840

Speed Up Your Compliance Process With Help from DuPont Tyvek October 5, 2017

LEGAL REQUIREMENTS FOR STABILITY

KCC Path-Core Page 1 of 5

PERFORMANCE SPECIFICATION WRAPPING MATERIALS, VOLATILE CORROSION INHIBITOR TREATED, OPAQUE

1. Cast-in-place concrete is specified in Section

Table of Contents. Pipette Tips. Table of Contents

Application Guidelines

STERILIZATION VALIDATION IN THIS SECTION REPROCESSING VALIDATIONS FOR REUSABLE MEDICAL DEVICES. Radiation Sterilization Validation

INNOVATIVE PLASTIC CONTAINERS

MOULDED AIRBOSS CBRN LIGHTWEIGHT OVERBOOT -MALO-

Precision. Proficiency. Proximity.

Plastics collapsible containers for human blood and blood components. Part 1: Conventional containers

SECTION JOINT SEALANTS PART 1 - GENERAL 1.01 RELATED DOCUMENTS

SOLAR SHADING SYSTEMS - Manual Solar Shade SECTION ROLLER WINDOW SHADES

REUSABLE MEDICAL DEVICE VALIDATION

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION:

26 Visqueen 100% Recycled Ecomembrane 28 Visqueen DPM To Pifa Standard PROOF. membranes

Application of Avery Dennison SW 900 Series Films Instructional Bulletin #4.08 (Revision 2) Dated: 01/17/17

Specialty Testing of Steam Sterilizers

2016. All rights reserved.

Inspection Hot Topics

Guiding Principles for the implementation of fluid management technologies for modern single use aseptic processing

Visqueen Ultimate HC BLOK

Packaging solutions MultiFresh

Engineering Branch Assets Delivery Group

PALISADE PD 40 SECTION SOLAR CONTROL FILMS. A. Optically clear Titanium Nitride ceramic sputtered polyester film for solar control.

Avery Dennison Supreme Wrapping Film ColorFlow Series Easy Apply RS Long Term Removable - StaFlat Revision: 0EU Dated: 05/07/16

Hollow, porous, solid,? Testing of Steam Sterilizers

TEKTON Flashings and TEKTON Construction Tape

VAPROLIQUI-FLASH. Liquid Applied Waterproof Flashing Material INSTALLATION INSTRUCTIONS

Secure. Tested. Certified.

Transcription:

Meeting the challenges of medical device packaging Gisela Cristina Mendes Bastos Viegas, S.A. October 14, 2011

Agenda Evaluation and selection Validation Test methods Sterile Barrier Systems

EN 868 Parts 2 10 Vertical standards for certain applications (products) ISO 11607-1 & 2 Part 1: Materials, sterile barrier systems, and packaging systems requirements Standards Part 2: Packaging process validation The scopes of both of these standards apply to health care facilities and wherever medical devices are packaged and sterilized. The presentation will focus and provide guidance on interpreting the ISO 11607 to health care facilities. It is recognized that the medical device manufacturer follows additional requirements.

Definitions Sterile Barrier Systems (SBS) previously known as primary packaging, the minimum package that prevents the ingress of microorganisms and allows aseptic presentation of the product at the point of use Protective Packaging a configuration of materials designed to prevent damage to the SBS and its contents from time of assembly until point of use. Protective packaging is designed to provide additional protection against damage and outside elements, not to provide a microbiological barrier Packaging System combination of the sterile barrier system and protective packaging

Preformed sterile barrier system (PSBS) Common choices pouches and reels sheets of sterilization wrap rigid reusable container When sealed using a validated process, they become sterile barrier systems.

What are the criteria? Evaluation and selection -packaging system What are the considerations? Preformed sterile barrier system (PSBS) Compliance with ISO 11607 Appropriate to the method of sterilization Suitability for use in specific applications and conditions of use Compatible with the labeling system Appropriate for the device(s) under consideration Evaluation and selection

Evaluation and selection Packaging System Provide adequate protection of the medical device(s) during intended specific storage and transportation to the point of use; Maintain sterile barrier integrity until its time of use; Ensure aseptic presentation at the point of use; Provide an adequate barrier to microorganisms; Allow for ease of identification of contents; Additional protection from the effects of environmental conditions (e.g. direct sunlight)during storage; Evaluation and selection Purchasers should evaluate the performance of each packaging system and use this information to determine that conditions for sterilization, shelf life, transport, storage, and handling can be met.

Sealable pouches and reels The following aspects should be considered: The size of the pouch and the strength of the packaging materials should be based on the medical device which is going to be packaged. The preformed sterile barrier system should be filled up to a maximum of ¾ of space. When two pouches are used, the inner pouch should be able to move within the outer pouch. This allows penetration of the sterilant and prevents the pouches from sticking together. For combining two pouches made from film and paper it is important that film meets film and paper meets paper for identification of content and permeation of sterilant. Evaluation and selection

Sealable pouches and reels Heat sealing devices should be able to control and monitor critical process parameters (e.g. temperature, pressure, sealing time/speed) in accordance with its validation criteria (e.g. alarms, warning system or machine stop in the event of any critical process parameter deviation). The seals should be smooth, i.e. without folds, bubbles, or wrinkles. Evaluation and selection

Sealable pouches and reels Closures that compress the package or device should not be used, (e.g. ropes, string, elastic bands, paperclips, staples or similar items). The pouch should be loaded so that the enclosed device will be presented aseptically. The pouch should be opened according to the manufacturer instructions. A design should show which direction the packaging has to be open. Evaluation and selection

Sterilization wrap The following aspects should be considered: The grade of the sterilization wrap should be chosen according to the size, shape and weight of the package to be wrapped. The size of the sterilization wrap should be selected to achieve adequate coverage of the item being packaged. The sterilization wrap should be large enough to cover the medical device, but it should not be so big that it has to be wrapped several times around the medical device, as this may impede sterilant penetration. Sequential wrapping using two barrier-type wrappers provides a torturous pathway to impede microbial migration. Evaluation and selection

Sterilization wrap The sterilization wrap should be designed in a manner that the opened wrapper should drape away from the sterile field. The wrapped package should be designed in a manner so that all edges are folded in such a way that do not interfere with aseptic presentation into the sterile field. The assembly surface area for wrapping should be flat, smooth, of adequate size, well lit and clean. Indicator tape is the most common closure for wrapped packages. Closures that compress the package or device should not be used. Evaluation and selection

Performance testing Testing the performance of a packaging system is a key principle for a good choice. Performance testing should allow verification on how well the sterile barrier system or packaging system holds up to the rigors of anticipated conditions of handling, distribution and transportation, before and after sterilization: The sterile barrier system needs to maintain its integrity without any holes, tears or seal/closure rupture that may be caused by the imposed stresses. Evaluation and selection

Performance testing How to do it? Evaluate it through all the intended processes of sterilization (multiple exposures, different sterilization processes), handling, distribution and storage, up to the point of use. Evaluate it for expected worst case scenarios: Use the device(s) that apply the most stress Use the worst case sterile barrier system produced at the process limits of sealing Evaluation and selection

Validation for forming sealing and assembly processes -Guidance on conformance to ISO 11607-2 Aim Avoid failures and reduce risks Critical to demonstrate the efficacy and reproducibility of packaging process A separate validation plan should be used for each different combination of sterilization process and sterile barrier system / packaging system (manufacturer, type, etc.). Validation

Validation for forming sealing and assembly processes What are the requirements? Implementation of validation consisting of: Installation Qualification (IQ) Operational Qualification (OQ) Performance Qualification (PQ) Process control and routine monitoring Procedure for addressing failure and corrective action to be taken; Process/packaging changes and revalidation Validation

A validation report should include: Responsibilities (i.e. facility, location, name of person responsible for validation and operator); Description of sterile barrier system contents; Rationale for selection of the worst case. Sample size (based upon a statistical valid rationale); Description of the sterilization process e.g. Steam sterilization at 134 C and 121 C, Ethylene Oxide, Gas plasma, LTSF (low temperature steam formaldehyde), including the cycle parameters and loading procedure used; Validation

A validation report should include: Description of the sterile barrier systems used; Type, size, grade and LOT number Supplier Does the material comply with ISO 11607-1? Does the material comply with EN 868-5 (reel and pouch) / EN 868-2 (wrap)? Validation

A validation report should include: Description of the operating procedures; Processes: (heat) sealing of pouches/reels wrapping: folding and closing of sterilization wraps; container: filling/loading and closing of reusable containers. Description of the protective packaging, if used; Rationale for selection of the worst case. Description of transport, distribution and storage conditions; Validation

A validation report should include: Acceptance criteria; Determine what attributes(s) will be evaluated, the method of evaluation and the results that will be considered acceptable. Qualification steps (IQ, OQ and PQ); Validation approval; In-process control and routine monitoring; Process/packaging changes and revalidation; Validation

Sterile barrier system stability (shelf life) Loss of package integrity is regarded as event-related rather than time related. Loss of package integrity depends on the: Quality of the sterile barrier system or packaging system Storage (environmental) conditions, the conditions during transport and the amount of handling Validation

Sterile barrier system stability (shelf life) Storage environment considerations Prevent any damage Controlled environment Maintaining temperature and humidity controlled Limit exposure to dust and sunlight Keep protective packaging in place Minimizing handling Physical separation of clean and contaminated items etc Validation

Test methods Test selection ISO 11607 has 4 pages of suggested test methods Common Standard Packaging Tests Integrity test Dye Migration ASTM F1929 Visual Inspection ASTM F1886 Strength test Seal Peel ASTM F88 Burst ASTM F1140

Dye penetration test ASTM 1929

Seal Peel Test ASTM F88

Seal Peel Test ASTM F88

Seal Peel Test ASTM F88

Burst Test ASTM F2054

Seal Peel Test ASTM F88

Test Methods - Key Points Any test method used for assessing suitability/monitoring of packaging systems packaging materials packaging process needs to be validated. This includes in-house methods and standard methods. Precision and bias statements that can be found in the standards can help assess any variability found in validation results.

Sealing process pouch and reel Attribute Method for evaluating Acceptance criteria Seal integrity Dye penetration test Visual inspection Intact and continuous seal Meets specified width No channel No wrinkles, creases or bubbles Package integrity Dye penetration test No punctures, tears or breaks Visual inspection Seal strength Seal peel test 1,5 N / 15 mm (Reference value indicated by EN 868-5) Aseptic presentation Visual inspection Able to open without damage or contamination of the contents Peel ability Peelable without material rupture, delamination, separation or degradation Yes/No

Wrapping process Attribute Method for evaluating Acceptance criteria Closure integrity Visual inspection Continuous, no opening or (Dye penetration test) breaches/gaps, no channels Package integrity Visual inspection No punctures, tears, breaks (Dye penetration test) Aseptic presentation Visual inspection Able to open without damage or contamination of the contents Assembly (folds, etc.) according to documented procedure/assembly instructions Visual inspection The opened SBS conforms to the documented procedure/assembly instructions Packaging configuration processed in the defined cycle Data-loggers Chemical indicators Have all sterilization parameters for the defined packaging configuration been met?

Re-validation Re-validation Device Process Equipment Sterile Barrier System Changes to:

Security is the mother of danger and the grandmother of destruction. "A segurança é a mãe do perigo e a avó da destruição. Thomas Fuller Thank you!