Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

Similar documents
Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

America s Wire Company

SECTION INSULATED WIRE AND CABLE

*** Supercedes: BECO E and COM , , & ***

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION GROUNDING AND BONDING

U.V resistance UL Sunlight Resistance. Flame retardant IEC

Welding Accessories

Evaluation of Aluminum Cable Presentation for IEEE OCS September 14, 2011 Breck Booker, Southwire

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU

welding Coleman Cable Inc. is a worldwide leader in the

This section applies to the design and installation relating to wire and cable systems and terminations. 16G Figure 1 16G Figure 2

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics

Una e mpre sa Vi akab l e GLOSSARY.

Engineering Data for Copper and Aluminum Conductor Electrical Cables

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less)

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)

BASIC CONCEPTS IN ELECTRICAL DESIGN. Prepared by Engr. John Paul Timola

Armoured Instrumentation Cables to BS7917

FP30112WHITE100 Heat Shrink TW Tubing 100' Spool

Electrical Insulating Tapes

Profile No.: 4 NIC Code: ELECTRICAL CABLES (SINGLE AND MULTICORE)

Article 300: Wiring Methods And Materials

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Electrical Conductors

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC Van Dam Street Long Island City, NY ELECTRIC METER SHOP DEPARTMENT

catalog Copper Wires

3M Cold Shrink Silicone Rubber Connector Insulators 8440 Series

Industrial LSZH Loose Tube, Gel-Free, Double-Jacket Cable

ANSI/NEMA WC 71 ICEA S Nonshielded Cables Rated V for Use in the Distribution of Electric Energy

MESH FLOOR HEATING SYSTEMS INSTALLATION INSTRUCTIONS

Heritage Quality Performance

3.0) TRANSMISSION LINES MINIMUM REQUIRED STANDARDS LINES

History of Cable Systems HISTORICAL OVERVIEW OF MEDIUM & HIGH VOLTAGE CABLES. Nigel Hampton

Construction guideline

Technical Specification for Single Core 38/66kV TR-XLPE Insulated Underground Cable

Bare Hard Density Pigs Used for drying and mild cleaning. Fully Coated Hard Density Pigs Withstands 5% presence of H 2

PT. KABELINDO MURNI Tbk SHIPBOARD CABLE WIRE AND CABLE MANUFACTURER. No. EMS No. OSH No. QCS 00152

Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

AGENDA. NEC Code-Making Panel 6. Report on Comment Meeting. December 6 December 8, Redondo Beach, CA

Cables for Railway Signalling Applications General Requirements

Effective June, Eaton-Durham Model # UTRS223ACH. Siemens, Model # SUAS877-PG. (or Landis & Gyr # UAS877-PG) Milbank. Model # U1980-O.

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

INTERNATIONAL STANDARD

3M Electrical, Electronic and EMI Shielding Tapes Selection Guide

ELECTRICAL CODE TRADE REFERENCE

Serv. Low-Voltage Cable Insulated Conductors for Overhead and Underground Distribution

Small Terminals. TEST CURRENT (Amps) Fig 1. Tensile strength of YAD HYLUG after axial rotation stresses. TENSILE STRENGTH IN POUNDS

FLEXIBLE CONDUITS AND CONNECTORS

WHITE PAPER Flex Life vs Flexibility

SECTION CHAIN-LINK FENCES AND GATES 02821/1

Technical Bulletin #27 Wiring for Architectural Applications

3M Round, Shielded/Jacketed, Flat Cable.050" 28 AWG Stranded, Mass Terminatable, PVC/PVC 3659 Series

WIRING METHODS CHAPTER 38

MGO INSULATED THERMOCOUPLES INDEX

Single-Jacketed Tubing

INTERNATIONAL STANDARD

Article 324: Flat Conductor Cable (FCC) 1.! Type FCC (flat conductor cable) cable wiring system is designed for installations under.

2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

A. Product Data shall be provided for each type of product indicated.

Technical Data. Excerpt from PRYSMIAN S WIRE AND CABLE ENGINEERING GUIDE

(Condensed from National Electric Code)

colonial electric supply

Type FLX Freezer Floor Frost Heave Protection DESIGN GUIDE

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

Service Entrance Cable Fittings

EMI Conductive Elastomer CSM Series

INDUSTRIAL ATTACK 800

CONDUITS AND FITTINGS

The Company by Peter Bröckskes sen. an independent, middle sized company

Cables for Drag Chains

B. Provide a complete conduit system with associated couplings, connectors, and fittings.

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Revisions for the 2011 National Electrical Code - Part 2

Technical Specification for LV ABC Fuse Switch Disconnectors

Cable solutions for Automation & Drives

Shrink-Kon Thin Wall Heat Shrinkable Tubing

FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES - PROJECT PACKING

Pair Count Minimum Bend Radius Design Type Maximum Pulling Tension

ACT. Summary. 1 Introduction. 2 Synoptic. 3 Technical characteristics. 4 Part-numbering system. 5 Arrangements. 6 Receptacles. 7 Plug / Panel seal

N-pump, Standard Motor

The University of Texas at Austin September 30, 2011

Introduction. Cable Assembly Solutions

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code

S OZ. WOVEN POLYETHYLENE F. R. S-3 KLEAR SPAN FR S-6 18 OZ. VINYL COATED POLYESTER (VCP) INNOVATIVE SOLUTIONS PRECISION RELIABILITY

CHAPTER 11 CONDUITS AND FITTINGS

THERMOCOUPLES and THERMORESISTANCES - Temperature measurement sensors for industrial use Figure 1: Standard Thermocouples

DETAIL SPECIFICATION CABLE, POWER, ELECTRICAL AND CABLE SPECIAL PURPOSE, ELECTRICAL SHIELDED AND UNSHIELDED, GENERAL SPECIFICATION FOR

B. Insulated Conductors: Stranded copper wire, green or green with yellow stripe insulation, insulated for 600 V, and complying with UL 83.

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

Flygt 3171, 50Hz. Technical Specification

Extended-Frequency SMA Connectors

Heatshrink & Cable Repair Solutions

SECTION 2: PROBES. Page 2-1

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

Transcription:

37-105VFD MMV-VFD Power Cable Three : kv - 15kV 133% Level Rated 90 C s (3) Soft annealed flexible stranded tinned copper per IEEE 150 Table 11. Extruded thermosetting 90 C Ethylene Propylene Rubber (EPR), meeting UL 1309 (Type E), IEEE 150 (Type E) and UL 1072. Shield Composite shield consisting of 0.012" tinned copper braided with nylon providing 0% copper Shielded coverage meeting UL 1309, IEEE Std. 150, and UL 1072. The nylon is colored for easy phase identification (three conductor = black, blue, red) without the need to remove the shield to find an underlying colored tape. Low smoke halogen-free jacket available. Contact your AmerCable rep. Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 150 and UL1072. Shield Semi-conducting layer meeting UL 1309, IEEE 150 and UL 1072. Symmetrical Insulated Grounding s (3) Soft annealed flexible stranded tinned copper conductor per IEEE 150 Table 11. Gexol sized per Table 23.2 of UL1072. Color: Green A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309/ CSA 25, IEEE 150, and UL 1072. This jacket allows for isolation between the insulation shields and overall shield. Shields can then be terminated on opposite ends to minimize circulating currents. Armor/EMI Shield Overall tinned copper braid plus aluminum/ polyester tape provides 100% coverage. This braid serves as both an armor and EMI shield meeting both IEEE 150 and UL 1307/CSA 25. Sheath (optional) A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309/CSA 25, IEEE 150, and UL 1072. Colored jackets for signifying different voltage levels are also available on special request (orange = kv and red = 15kV). n UL Listed as Marine Shipboard Cable (E1111) n American Bureau of Shipping (ABS) n Det Norske Veritas (DNV) Pending n Lloyd s Register of Shipping (LRS) Pending n 90 C Temperature Rating n Voltage Rating kv to 15kV (25kV available on request) s A flexible, braid and foil shielded, power cable specifically engineered for use in medium voltage variable frequency AC drive (VFD) applications. n Flexible stranded conductors and braided shields. Suitable for applications involving repeated flexing and high vibration. n Small minimum bending radius (x OD) for easy installation. n has a very low dielectric constant. This allows for longer output cable distances and minimizes common mode current. n Overall braid plus foil shield is engineered with 100% coverage and a surface transfer impedance <50 milliohms at 10MHz to contain EMI. n Symmetrical insulated ground conductors reduce induced voltage imbalances and carry common mode noise back to the drive. n High strand count conductors and braid shield design is much more flexible, easier to install and more resistant to vibration than Type MC cable. n Severe cold durability: exceeds CSA cold bend/cold impact (-0 C/-35 C). n Flame retardant: IEC 332-3 Category A and IEEE 1202. n Suitable for use in Class I, Division 1, and Zone 1 environments. 1 Manufactured by Nexans AmerCable (70) 2-919 (00) 3-151 Fax (70) 2-913

Three Type MMV-VFD Medium Voltage kv 133% Level Single Inductive Voltage Green Insulated In Free Banked DC Resistance AC Resistance Reactance Drop Grounding (Lbs./ Air in Trays at 25 C at 90 C, 0Hz (ohms/ (Volts per amp (3x) mm2 37-105 (inches) 1000 Ft.) (amps) (amps) (ohms/1000 Ft.) (ohms/1000 Ft.) 1000 Ft.) per 1000 Ft.) (AWG) 2 1 1/0 2/0 3/0 /0 22 313 373 535 12.5 21 3 3 5 70 109 132 159 19 227 273-332TSVFD -333TSVFD -33TSVFD -335TSVFD -33TSVFD -337TSVFD -33TSVFD -339TSVFD -30TSVFD -31TSVFD -32TSVFD -33TSVFD -3TSVFD 1.7 1. 2.071 2.11 2.22 2.31 2.9 2.31 3.57 3.030 3.1 3.319 3.92 13 207 225 3022 3373 32 11 5093 5993 7 710 55 9905 11 152 175 201 232 2 30 3 3 29 55 52 75 99 129 19 171 197 22 20 29 32 35 37 9 Cable diameters are subject to a +/- 5% manufacturing tolerance Three Type MMV-VFD Medium Voltage 15kV 133% Level 0.5 0.300 0.1 0.17 0.117 0.093 0.07 0.05 0.0 0.00 0.03 0.02 0.02 Single Inductive Voltage Green Insulated In Free Banked DC Resistance AC Resistance Reactance Drop Grounding (Lbs./ Air in Trays at 25 C at 90 C, 0Hz (ohms/ (Volts per amp (3x) mm2 37-105 (inches) 1000 Ft.) (amps) (amps) (ohms/1000 Ft.) (ohms/1000 Ft.) 1000 Ft.) per 1000 Ft.) (AWG) 0.55 0.37 0.230 0.1 0.17 0.117 0.09 0.075 0.03 0.053 0.05 0.039 0.033 0.0 0.03 0.00 0.03 0.037 0.03 0.035 0.033 0.032 0.032 0.031 0.030 0.030 0.20 0.5 0.359 0.29 0.22 0.199 0.1 0.139 0.121 0.10 0.09 0.05 0.07 10 10 10 2 1 1/0 2/0 3/0 /0 22 313 373 3 3 5 70 109 132 159 19 227-357TSVFD -35TSVFD -359TSVFD -30TSVFD -31TSVFD -32TSVFD -33TSVFD -3TSVFD -35TSVFD -3TSVFD 2.03 2. 2.59 2.71 2.75 3.02 3.20 3.33 3.500 3.52 3231 2959 090 15 530 131 707 777 703 9912 15 17 205 23 29 309 352 39 32 5 133 151 17 199 229 23 299 331 37 3 0.1 0.17 0.117 0.093 0.07 0.05 0.0 0.00 0.03 0.02 0.230 0.1 0.17 0.117 0.09 0.075 0.03 0.053 0.05 0.039 0.00.030.01 0.0390.03 0.037 0.035 0.03 0.03 0.033 0.3 0.299 0.2 0.203 0.170 0.12 0.12 0.109 0.097 0.00 10 Cable diameters are subject to a +/- 5% manufacturing tolerance in Free Air: Based on 105 C conductor temperature and 0 C ambient temperature per 200 NEC Table 310.71 in Conduit Air: Based on 105 C conductor temperature and 0 C ambient temperature per 200 NEC Table 310.75 www.nexansamercable.com e-mail: industrial@nexansamercable.com 19

37-9-5020PNAV Enhanced THOF Ship-to-Shore Power Cable 90 C 00 Volts Flexible Type I EPR rated for 90 C in wet or dry locations. Meets requirements of UL RHH, RHW-2 Color coded white red black Reinforced, flame retardant extra heavy duty black thermoset CPE specially formulated to resist the abrasive nature of the application s 500 tin coated copper. ASTM B-33, ASTM B-172 Separator 2 mil non-hygroscopic opaque polyester A flexible 00V cable used for ship-to-shore power. Replaces former MIL-C 915 design for most applications. n Complies with OPNAVINST 11310.3B n Integral filled inner jacket for enhanced toughness and crush resistance n Water migration minimized n Mold cured reinforced jacket for enhanced abrasion and tear resistance n Pigment colored jacketed singles for phase identification n Tinned copper conductors for reduced corrosion n Indent printed for long term identification n Functional testing to ensure flexibility in both summer and winter conditions n ICEA S 75-31: Portable and Power Feeder Cables for Use in Mines and Similar s Product Enhanced THOF 37-9-502OPNAV 500 2.75 753 Cable diameters and weights are subject to +/- 5% manufacturing tolerance Consult factory for availability of other conductor sizes MIL-C 915 cable is also available. Consult factory for details. 20 Manufactured by Nexans AmerCable (70) 2-919 (00) 3-151 Fax (70) 2-913

37-9-5030PNAV Enhanced PLUS THOF Ship-to-Shore Power Cable 90 C 00 Volts Flexible EPR per ICEA S-75-31 Meets requirements of UL RHH, RHW-2 Enhanced Plus Only. CPE Composite meets requirements of UL RHH, RHW-2. Pigment colored red, white and black. Class I, 500 tin coated copper. ASTM B-33, ASTM B-172 Extra-Heavy duty reinforced, flame retardant black thermoset CPE per ICEA S-75-31. Specially formulated to resist the abrasive nature of the application. A tough flexible 3/C 00V ungrounded power cable specifically designed for naval shore-to-ship and other pier side power applications. Enhanced Plus THOF is specially designed for additional sunlight and weather resistance. n Complies with OPNAVINST 11310.3B n Integral filled inner jacket for enhanced toughness and crush resistance n Water migration minimized n Mold cured reinforced jacket for enhanced abrasion and tear resistance n ed singles (Enhanced Plus) for increased resistance to sunlight and weather n Pigment colored jacketed singles for phase identification n Tinned copper conductors for reduced corrosion n Indent printed for long term identification n Functional testing to ensure flexibility in both summer and winter conditions n ICEA S-75-31: Portable and Power Feeder Cables for Use in Mines and Similar s Product Enhanced Plus THOF 37-9-503OPNAV 500 3.003 75 Cable diameters and weights are subject to +/- 5% manufacturing tolerance Consult factory for availability of other conductor sizes MIL-C 915 cable is also available. Consult factory for details. www.nexansamercable.com e-mail: industrial@nexansamercable.com 21

37-003 Flexible Grounding Cable Clear Yellow Other Colors Transparent thermoplastic for ease of installation and flexible use at temperatures ranging from -25 C to 90 C. This material meets Type II requirements of ASTM F 55. Material meeting a -50 C cold bend is available on a special order basis. Bunched strands of bare copper annealed dead soft in accordance with ASTM B-3. Other strand is available upon request. Identification A marker tape printed AMERCABLE-SIZE- GROUNDING CABLE is readily visible under the transparent jacket. Flexible jacketed cable used for grounding jumpers installed temporarily for protective grounding of de-energized circuits. n Transparent jacket provides easy confirmation of continuity and ease of trouble shooting n Extremely flexible stranding for ease of bending and installation n Transparent thermoplastic jacket for installation and flexible use at temperatures ranging from -25 C to 90 C n material meets Type II requirements of ASTM F-55 n material meeting Type I (-50 C) requirements of ASTM F-55 available upon request 37-003- 002 2 5 0.100 0.530 293 010 1/0 1050 0.100 0.50 5 020 2/0 1323 0.105 0.700 557 00 /0 2107 0.110 0.50 57 Cable diameters and weights are subject to +/- 5% manufacturing tolerance Other ground jacketing materials and colors available. Consult factory for details. n ASTM B-3: Standard Specification for Soft or Annealed Copper Wire n ASTM F-55: Standard Specifications for Temporary Protective Grounds to Be Used on De-energized Electric Power Lines and Equipment Order Your Grounding Cables with Factory Installed Connectors SAVE TIME SAVE MONEY 22 Manufactured by Nexans AmerCable (70) 2-919 (00) 3-151 Fax (70) 2-913

37-09 Lead Covered Grounding Cable Uncoated annealed copper meeting the requirements of ASTM B-3 A grounding conductor for use in power distribution systems where a lead sheath is required over the copper conductor to provide additional protection against corrosion. Also suitable for use in lightening protection applications. n Lead sheath offers rugged, durable construction n ASTM B-3: Standard Specification for Soft or Annealed Copper Wire Lead Sheath An extruded layer of lead for enhanced performance n ASTM B-: Standard Specification for Concentric-Lay-Stranded Copper s, Hard, Medium-Hard or Soft 37-09- Lead Sheath 00 7 0.05 0.319 3 005 2 7 0.05 0.377 50 3 1/0 19 0.05 0.97 3 020 2/0 19 0.05 0.52 9 30 3/0 19 0.05 0.00 1202 15 /0 19 0.05 0. 120 250 250 37 0.05 0.9 152 351 350 37 0.05 0.797 195 17 00 37 0.05 0.2 27 31 500 37 0.05 0.931 2 Cable diameters and weights are subject to +/- 5% manufacturing tolerance www.nexansamercable.com e-mail: industrial@nexansamercable.com 23

37-221 Red Jumper Cable Flexible 5000/15000 Volts 90 C s Flexible-stranded, tinned, annealed coated copper per ASTM B-33 Shield Combination semiconducting tape and/or extruded semiconductive thermosetting material. The semiconductive tape prevents any penetration of the extruded conductor shield into the inner layers of the flexible conductor. Thermosetting bright red jacket, 90 C rated Heat resisting 90 C Ethylene-Propylene rubber (EPR), meeting ASTM D-202. It has excellent dielectric properties and is highly resistant to heat, moisture, and ozone. Identification Cable is surface printed showing manufacturer s name, size, voltage rating, and temperature rating Portable dual rated 5000/15000 volt jumper cables can be used as temporary jumper leads for portable or mobile substations, or for temporarily by-passing damaged or faulted sections of power cable. The finely stranded conductor provides an exceptionally flexible cable that can be easily trained and connected in confined areas such as transformer vaults and switch gear enclosures. n Extremely flexible stranding n Bright red thermosetting jacket n The conductor shield is bonded to the insulation providing easy, clean stripping n The 90 C insulation has excellent dielectric properties and is highly resistant to heat, moisture and ozone. n ASTM B-33: Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes n ASTM D202: Standard Specification for Ozone- Resistant Ethylene-Alkene Polymer for Wire and Cable Note Jumper cables should NOT be used in place of normal high voltage cables. They should be isolated in areas where contact with people is limited. Because jumper cables cannot be protected against prolonged contact with other conductors or grounds by shielding, these cables must be positioned away from contact with grounds, transformer cases, cross-arms, etc., to avoid possible high stress and capacitance leakage. Cables should be installed with at least one cable diameter of separation between adjacent conductors and between conductors and all metallic and/or electrically grounded parts. These cables are not intended for permanent service. 2 Manufactured by Nexans AmerCable (70) 2-919 (00) 3-151 Fax (70) 2-913

37-221 Red Jumper Cable 5000/15000 Volts 37-221- 00 133 0.210 0.05 0.777 310 3/NA* 00 133 0.210 0.05 0.1 30 110/110 00 259 0.210 0.05 0.75 9 15/150 003 3 259 0.210 0.05 0.903 95 170/170 002 2 259 0.210 0.05 0.9 53 190/195 001 1 259 0.210 0.05 0.91 35 225/225 010 1/0 2 0.210 0.05 1.00 72 20/20 020 2/0 323 0.210 0.05 1.090 9 300/300 030 3/0 1 0.210 0.05 1.133 97 35/35 00 /0 532 0.210 0.05 1.215 111 00/00 250 250 27 0.210 0.05 1.21 121 5/5 350 350 0.210 0.05 1.327 192 550/550 500 500 1221 0.210 0.05 1.5 2192 95/5 AWG Jumper recommended only for use at 5kv Cable diameters and weights are subject to +/- 5% manufacturing tolerance is calculated with a 90 C conductor temperature and 0 C ambient air, per 200 NEC, Table 310.9 90 C at 5kV/15 kv SAVE TIME Order Your Red Jumper Cable with Factory Installed Connectors SAVE MONEY www.nexansamercable.com e-mail: industrial@nexansamercable.com 25

37-550 Mobile Substation Power Cable Type SH Single 5000 to 35000 Volts 90 C Flexible tin-coated soft annealed bunch stranded copper meeting ASTM B-33 Shield Tin-coated copper braid applied over a semiconductive tape (5-15kV). Extruded semi-conductive thermosetting material (25-35kV) CPE meeting ICEA S-75-31/NEMA WC5. Consult factory for availability of other jacket materials. Shield Combination semi-conducting tape and/or extruded semiconductive thermosetting material Heat, moisture and ozone resisting 90 C Ethylene- Propylene rubber (EPR) meeting ICEA S-75-31/NEMA WC5 Identification Cable shall be surface printed showing manufacturer, size, voltage rating, type and temperature rating These single conductor portable power cables are extremely flexible and specifically designed for use on mobile substation equipment. The Type SH cable is often necessary for supplying power while replacing damaged utility poles or during routine maintenance of substations. n Extremely flexible stranding for ease of bending n The conductor shield is bonded to the insulation providing easy, clean stripping n is heat, oil, flame and chemical resistant n Continuous conductor temperature 90 C n s available in voltage colors, yellow (5 & kv), orange (15kV), red (25 & 35kV). Consult factory for availability of other colors. n ASTM B-33: Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes n ICEA S-75-31/NEMA WC-5: Portable and Power Feeder Cables for Use in Mines and Similar s n UL 1072 Medium Voltage Cable MV-105 (pending) CSA approval available by special order 2 Manufactured by Nexans AmerCable (70) 2-919 (00) 3-151 Fax (70) 2-913

5kV Single Portable Power Cable Type SH 37-550- 90 C 002 2 259.110.125 0.975 7 190 00 1/0 2.110.10 1.05 25 20 005 2/0 323.110.10 1.170 1039 300 007 /0 532.110.155 1.300 1393 00 00 250 27.120.155 1.330 177 5 022 350.120.170 1. 192 550 010 500 1221.120.190 1.700 22 95 15kV Single Portable Power Cable Type SH 37-550- 90 C 01 2 259.210.155 1.203 1 195 017 1/0 2.210.155 1.320 117 20 01 2/0 323.210.155 1.350 122 300 020 /0 532.210.170 1.97 159 00 021 250 27.210.170 1.57 175 5 009 350.210.190 1.75 23 550 02 500 1221.210.190 1.900 2937 5 25kV Single Portable Power Cable Type SH 37-550- 90 C 030 1/0 2.295.170 1.500 1350 20 031 2/0 323.295.170 1.555 1507 300 033 /0 532.295.190 1.713 1909 395 03 250 27.295.190 1.73 205 0 035 350.295.190 1. 2517 55 037 500 1221.295.205 2.0 31 0 Order Your Type SH Cables Connectorized! Factory installed assemblies from AmerCable help lower your overall connectivity costs. n Lugs n Elbows n Stress Cones 35kV Single Portable Power Cable Type SH 37-550- 050 1/0 2.30.170 1.175 132 20 051 2/0 32.30.205 1.0 19 300 053 /0 532.30.205 1.915 2235 395 05 250 27.30.205 1.975 2509 0 055 350.30.205 2.100 2901 55 057 500 1221.30.205 2.20 339 0 Cable diameters and weights are subject to +/- 5% manufacturing tolerance is calculated with a 90 C conductor temperature and 0 C ambient air, per 200 NEC, Table 310.9 90 C www.nexansamercable.com e-mail: industrial@nexansamercable.com 27