ClinScan. think forward. Small Animal MRI Solution for Molecular Imaging and Translational Research. Preclinical MRI

Similar documents
Simple, intuitive and accessible MRI solution for preclinical research. M-Series Compact MRI Systems

Vantage Titan 1.5T MR. The Intelligent Choice.

I-class. All together a better way to work. MAGNETOM Avanto.

New PET/CT from Siemens helps more patients benefit from premium technologies

Power-class. Expect more performance. MAGNETOM Symphony.

3-TESLA MAGNETIC RESONANCE SPECTROMETER SYSTEM Centre for Neuroscience, Indian Institute of Science, Bangalore

Ingenia MR-RT. MR Systems. The comprehensive MR-sim solution to fit your planning

MAGNETOM Skyra: The Mannheim Perspective

Magnetic Resonance Imaging (MRI) Safety for Boston Scientific Products. 1. WALLSTENT Iliac Endoprosthesis with Unistep Plus Delivery System

Recharge your MR experience.

Vevo The Ultimate Preclinical Imaging Experience

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment QTRAP 5500

making functional MRI easy Complete Products and Solutions for fmri

Brochure. Equator gauging systems

IR READY TO GO. Spectrum Two FT-IR Spectroscopy

Low Dose, Lightning Speed, Latest Applications

MRI in Clinical Practice

Reaction Monitoring: InsightMR

MAGNETIC RESONANCE IMAGING OF IN VIVO FLOW PHENOMENA

Delivering top performance. Outstanding value. Diagnostic scalability. ACUSON X150 Ultrasound System.

Clinical Translation of Tumor Acidosis Measurements with AcidoCEST MRI

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

TANGO. ANALYSIS TO GO. Innovation with Integrity. The next generation FT-NIR spectrometer. FT-NIR

MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE. LAMBDA 265 / 365 / 465 UV/Vis Solutions

Preclinical in vivo Imaging. Innovation with Integrity. Preclinical Imaging. Nine modalities - Unlimited research capabilities

Award Number: W81XWH TITLE: Magnetic Resonance Characterization of Axonal Response to Spinal Cord Injury

siemens.com/luminos-select Luminos Select don t compromise, be select.

Institute of Neurosciences and Medicine: Medical Imaging Physics

Chapter 2. Magnetic Resonance Safety. Andrew Simmons and Kristina Hakansson. Abstract. 1. Legislation, Guidance and Best Practice

Handzettel 1. CARE Right Computed Tomography, committed to the right dose Ivo Driesser Austin, July 22 nd 2014

Control Products & Systems OEM siemens.com/buildingtechnologies-oem

Sensortherm. Digital Pyrometer. Temperature Measurement and Control. com

MRI Systems Market to 2018

Featuring Analyst software under Windows NT for enhanced performance and ease of use. API 150EX. LC/MS System

Introducing a new take on efficient workflow: Deeply integrated clinical applications

Computed Tomography. Printed in Japan

MetaXpress High-Content Image Acquisition and Analysis Software

GENESIS Edition. Transforming CT

Artis Q and ArtisQ.zen

Publication for the Philips MRI Community Issue 40 May 2010

SICK Airport Innovations. Sensors and solutions

CO 2. and fiber laser product range. Laser Marking Solutions

Automated Breast Volumes. Simplified.

BIOMEDICAL SIGNAL AND IMAGE PROCESSING

Synergy On Nicolet EDX. Advancing electrodiagnostics and monitoring with the next generation system. Nicolet

GENESIS Edition Transforming CT

NUPECC PAPER. Nuclear Magnetic Resonance (NMR)

MetaXpress High-Content Image Acquisition and Analysis Software

Clinical Applications. ImagingRite. Neuro Intervention. 1 ImagingRite

rapiflex Innovation with Integrity Designed for Molecules that Matter. MALDI TOF/TOF


HIGHER IMPACT LC/MS DIAGNOSTICS AGILENT IN VITRO DIAGNOSTIC MEDICAL DEVICES FOR CLINICAL LABORATORIES

Motiva: a TV-based platform for remote patient management

For More Cost- Effective Production: Manufacturing Processes Based on Cavity Pressure

NIR Checkmaster Near-infrared spectroscopy On-line analysis of active ingredients during tablet production

GE Healthcare. Forge. SIGNA Architect fueled by SIGNA Works. Imagine what MR can be. Make the unimaginable the expected. Architect is CE-marked.

Introduction: what do we mean by Quantitative MRI?

Extending quality care to more people. Brivo CT315

SCION GC Series. The Gas Chromatographers Choice for Separations

Advances in arterial spin labelling MRI methods for measuring perfusion and collateral flow

QINEO Product overview

siemens.com/healthcare Multix Select DR First time. First choice.

Optimize efficiency with a universal system.

PinAAcle 500. Flame Atomic Absorption Spectrometer

QINEO PULSE. The versatile welding machine for industry

SMARTBRUSH ANGIO. Version 1.0. Software User Guide Revision 1.0. Copyright 2014, Brainlab AG Germany. All rights reserved.

7T MRI research in neurology: initial results and future research applications

Superconducting. magnets. The heart of NMR

Reinventing Leak Test

MasterView Software. Turn data into answers reliable data processing made easy ONE TOUCH PRODUCTIVITY

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

GRP System FX. The «all in one» railway surveying solution

The Potential for Electromagnetic Metal Forming for Plane (Car Body) Components

MEDICAL PHYSICS (MED PHYS)

DATALOGIC SCANNING.

MEDTECH. Motion systems. for challenging Diagnostics and Patient Care applications. from mind to motion

Surface Plasmon Resonance Systems

Spectroscopy Solutions for Pharmaceuticals:

T U R B O B L O W E R S

HPLC/FLASH Purification ADVANCE THE PACE OF YOUR DISCOVERY TO ACHIEVE THE RESULTS OF TOMORROW

Detecting Peripheral Nerves in the Elbow using Three-Dimensional Diffusion-Weighted PSIF Sequences: a Feasibility Pilot Study

ACUSON P500 Ultrasound System FROSK edition FROSK Edition

Integrated engineering with COMOS and SIMATIC PCS 7

Welch Allyn Connex Vital Signs Monitor 6000 Series and Accessory Cable Management Stand

Q-STRESS CARDIAC STRESS TESTING SYSTEM

ALD Vacuum Technologies High Tech is our Business. DualTherm. Double Chamber Vacuum Furnace for flexible heat treatment

Build With VICTUS. Build Your Patient Offerings. Build Your Premium Practice.

The Full Range for RFID

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

QIBA Profile: Diffusion-Weighted Magnetic Resonance Imaging (DWI)

MonTech RP 3000 Rapid Plastimeter for Polymers and Natural Rubber

TECHNOLOGY SPECIFIC REVIEW CRITERIA FOR EURO-BIOIMAGING NODES

Headquarters West Coast The company of µ

Nuclear Medicine Solutions

Transcription:

ClinScan Small Animal MRI Solution for Molecular Imaging and Translational Research think forward Preclinical MRI

Be Clinical from the Very Beginning With ClinScan you enter the field of translational research and molecular imaging The ClinScan, a 7 T animal MRI and MRS scanner is designed to further facilitate translational research from mice to men in the field of preclinical and molecular imaging. ClinScan is Bruker BioSpin s solution for an emerging market of research MRI systems that allows a direct and fast transfer of preclinical studies on animal models to clinical studies on humans. By virtue of the strategic alliance with Siemens Medical Solutions on human high-field MR systems, ClinScan uses the clinical user interface syngo MR. Its operation is identical to that of Siemens MAGNETOM TIM systems.

Product Description 7 T Bruker USR magnet (Ultra Shielded Refrigerated, bore size 20 cm or 30 cm) Bruker gradient and shim coil (gradient strength of 290 mt/m or 630 mt/m, slew rate of 1160 T/m/s or 6300 T/m/s) Bruker RF array coil technology in combination with numerous animal handling accessories Siemens MAGNETOM Avanto technology with up to 32 receive channels Clinical routine user interface syngo MR to enable efficient workflow and highly automated state-of-the-art MRI and MRS applications on small animals ClinScan systems are designed for translational molecular MRI and provide the clinical routine user interface syngo MR that facilitates straightforward transfer of protocols from bench top to bedside and vice-versa

Integrated MRI Solutions Magnets Technology Modern magnets are available with shielding of the external magnetic field. This is achieved by use of a second superconducting coil which compensates the magnetic field outside the magnet. Bruker s UltraShield technology drastically reduces the stray field to close to the magnet and thus strongly reduces the magnetic field to which the operator is exposed. All Bruker USR magnets include refrigeration technology for long helium hold time and minimum number of maintenance intervals. Gradients Technology We offer ClinScan with a water-cooled actively shielded gradient system that is optimized for high gradient strength, shortest rise time, and high gradient linearity. Our gradients have been constructed using streamline design technology which strongly reduces the amplitudes and decay times of any induced eddy currents. RF Coils Technology A body coil for transmission and reception covering a large FOV is permanently integrated in the system. In addition, a comprehensive line of dedicated receive-only surface coils is provided in order to support many individual applications. Bruker provides state-of-the-art multi-channel array coil technology for parallel imaging applications. Integrated preamplifiers guarantee an optimal signal-to-noise ratio over a large dynamic range from 3D fast imaging to single voxel spectroscopy. Standard proton RF coils do not require manual tuning or matching to enable automated and routine workflow. MRI CryoProbe TM This unique innovation delivers an increase in sensitivity by a factor of typically 2.5 compared to standard room temperature RF coils. This results in even higher spatial or temporal resolution and shorter scan times. Cold surface contact with the animal is eliminated by a special patented provision.

ClinScan features syngo MR, the graphical user interface optimized for clinically-oriented workflow. Clinical User Interface syngo MR Parallel working and one-click examinations are supported efficiently. Parallel scanning and reconstruction are standard. Images can be loaded and used for graphical slice planning during reconstruction. ipat (integrated Parallel Acquisition Techniques) further increase the acquisition speed. ipat is fully compatible with the optional phased array coils. Dynamic Analysis evaluation and Mean Curve software enable the calculation of functions and dynamic examinations. IDEA sequence development environment with research agreement. syngo syngo

Application Packages Application packages for animal MRI resemble the application packages you already know from clinical MRI. Sequences and protocols are optimized for the specific needs in animal MRI. Standard Imaging The application suite is a full set of programs and protocols optimized for a wide range of high field applications. Spin Echo (Single, double, multi echo) High resolution 3D T 1 -weighted imaging (MPRAGE) of rat brain (left) and (TIR) of mouse brain (right) 2D/3D FLASH 2D FLASH segmented Inversion recovery (IR) 2D/3D Turbo Spin Echo (TSE) Dark Fluid TSE 2D/3D PSIF 2D/3D TSE Restore (DEFT), with Gain Switching T 2 -weighted imaging (Turbo Spin Echo) and SE-EPI with 8 segments of a rat brain Hyperecho TSE for SAR reduction Variable flip angle 3D TSE 2D/3D Turbo FLASH 2D/3D Time-of-Flight (TOF) Angiography Single shot and segmented gradient and spin echo EPI Cartilage of rat knee (DESS) and rat brain, inner ear (CISS 3D) Parallel Imaging ipat (integrated parallel Imaging) techniques including GRAPPA & msense Integrated Auto-Calibration: no timeconsuming reference scan Higher speed and temporal resolution Increased image resolution Reduced image distortion ipat is integrated with all relevant imaging techniques Rat brain, TSE, GRAPPA ipat, TR: 2 s, TE eff : 45 ms, Resolution: 78 x 78 µm², ipat factor 1 (left), ipat factor 2 (right)

Diffusion imaging (DTI) Diffusion and Perfusion Imaging Echo Planar Imaging (EPI) Multi directional diffusion weighting Tensor calculation including tractography Perfusion applications including processing Chemical shift imaging with outer volume suppression Spectroscopic Imaging & Spectroscopy Spin Echo & STEAM, PRESS and CSI Fully automated adjustments including localized shimming and adjustment of water suppression pulses Hybrid CSI technique including volume selection and FoV encoding 2D & 3D acquisition k space weighted averaging Multi-nuclei option Cardiac Imaging Cardiac Imaging True FISP & 2D/3D FLASH segmented Magnetization prepared TrueFISP Prospective triggering & retrospective gating Retrospectively gated cine imaging Phase sensitive IR BOLD Imaging Single Shot EPI with PACE for BOLD-Imaging Mosaic images for efficient storage and transfer of large data sets Automatic image reconstruction as well as on-the-fly t-test calculation in real-time for variable paradigms Rat brain, BOLD fmri

ClinScan S -line The ClinScan S -line is Bruker s cost-efficient solution for clinically-oriented animal MR on small animals such as rats and mice. It consists of a 7 T magnet with 20 cm inner bore and is equipped with the water-cooled BGA-12S. The ClinScan S -line is equipped with an automatic positioning system for animal beds which also serves as the Faraday shield. Thanks to the compact size of the magnet, its minimum stray field and the included Faraday shield, very cost-efficient siting is assured. For rats and mice Cost-efficient siting Low stray field Low weight Small dimensions of magnet ClinScan S -line Magnet Diameter of clear bore Stray field (5 Gauss) Gradient Active shielding Integrated shim set up to 2nd order Outer / inner diameter Gradient amplitude Slew rate Linearity 7 T > 200 mm +/- 1.45 m axial, +/- 1.4 m radial Yes Yes (198 / 114) mm 630 mt/m 6300 T/m/s 80 / 50 mm dsv <± 4.5 % / <± 1 %

ClinScan The ClinScan is Bruker s animal MR system for clinical translational studies on animals from mice to small rabbits. Its 7 T magnet with 30 cm inner bore is ideal for combining MRI with other modalities like PET for molecular imaging. It is equipped with the water-cooled BGA-20S. For perfect homogeneous excitation a body coil with inner diameter of 154 mm is used. Large bore flexibility: from mice to rabbits Space for monitoring equipment Combination with other modalities (MRT/PET, MRT/opt, ) possible Larger field of view in z-direction Future gradient/shim upgrades offer flexibility Body coil for large homogenous excitation ClinScan, a high field MRI system for preclinical imaging with animal handling accessories for high throughput, animal welfare and monitoring ClinScan Magnet Diameter of clear bore Stray field (5 Gauss) Gradient Active shielding Integrated shim set up to 2nd order Outer / inner diameter Gradient amplitude Slew rate Linearity 7 T > 302 mm +/- 3 m axial, +/- 2 m radial Yes Yes (302 / 201) mm 290 mt/m 1160 T/m/s 130 / 100 mm dsv <± 3 % / <± 2 %

Positioning System For delivering high animal throughput with controlled animal welfare and monitoring, the integrated animal accessory system is a core component of every ClinScan. Positioning system A preparation table is attached to the magnet and holds a manual slider system or an automatic positioning system onto which the different animal beds are placed for fast and reproducible positioning of the animals. The concept enables several animals beds to be used in parallel e.g. one on the slider in the magnet for data acquisition, one for animal preparation and one is undergoing cleaning. Animal Beds & Cradles A variety of animal beds tailored for different animal species, applications and RF coils are available. Most of them are equipped with a nose-cone for gas anaesthesia, three point-fixation system (tooth-bar and ear-plugs), openings for throat access and body temperature stabilization. In addition, animal beds can be equipped with a temperature controlled warming blanket. Monitoring & Triggering Stand-alone animal monitoring and triggering unit Many MRI/MRS applications require triggered acquisition to avoid motion artefacts. In addition, animal care regulations require continuous monitoring of the status of the animal in the magnet. For this, Bruker offers a stand-alone unit that can trigger and gate on a variety of biological signals (ECG, respiration, temperature) and can record all those tracks for later correlation to an image time series. The ECG-sensors are equipped with special filters to suppress gradient/rf-interference and additional user-defined sensors can be incorporated.

Service & Support Bruker BioSpin s commitment to providing the highest quality service results in more productivity from your ClinScan system. From the initial site evaluation, through system installation, and throughout the life-time of your instrument, Bruker BioSpin s service program is dedicated to providing personalized support. By investing heavily in the training of our engineers and support staff, we ensure their up-to-date expertise in the latest MRI technologies. Whether through Bruker BioSpin s support centers, the application, service and software hotlines, or an on-site visit, you can be confident that your Bruker service representative is trained, experienced, and prepared to work diligently to quickly complete your support request. Site planning Proper site planning for your MRI scanner is the first step in ensuring optimum system performance. Bruker BioSpin engineers have considerable experience in siting large and small high-field systems, both in existing and new buildings. Thus, expert advice is available for solving virtually any complex siting problem. Contact Hotline Service: mri-hardware-support@bruker-biospin.de Hotline Application: mri-application-support@bruker-biospin.de For additional information please visit: www.bruker-biospin.com/mri Application Support Bruker BioSpin provides a worldwide network of senior application scientists to support your research programs. In addition to the training immediately after installation customers can join the Bruker BioSpin Application Continuity Program. Responsive Technical Support Should you ever have questions or require assistance with your ClinScan system, our service & support hotlines are your gateway to a solution. The support center engineers and scientists will quickly and efficiently gather key information and suggest relevant diagnostics. Worldwide support centers arrange for parts to be delivered to your laboratory for trouble-shooting and repair. Training courses Bruker BioSpin offers training courses from introductory classes to advanced operator and programming courses. The courses cover a wide range of applications and include hands-on lab sessions in our dedicated application support centers. For the training schedule and registration, please visit to www.bruker-biospin.com/mri-training. Application support center including training and demo facilities in Germany.

Bruker BioSpin Bruker BioSpin 08/10 T11800 DE info@bruker-biospin.com www.bruker-biospin.com