ELVORON LU/LA ELEVATOR

Similar documents
Introduction. Disclaimer. Table of contents

Residential Elevator Design Guide

SPECIFICATIONS. Part 1- General

Beautifully Crafted, Expertly Engineered, Thoughtfully Constructed

SECTION HYDRAULIC DRIVE MACHINE ROOM (MR) RESIDENTIAL ELEVATORS

Savaria Eclipse Home Elevator

Planning Guide (Imperial)

Revision 1 RAM ELEVATORS. Elevator Electrical Planning Guide. RAM Manufacturing Ltd

You dream it. We build it. ELEVATORS

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

2. Cab, interior finishes, control panel and facings including cab doors. 3. Fire rated hoistway doors, sills, and frames.

Elevating your standard of living

Series - 1

PART 2. PRODUCTS 2.01 Traction Elevators A. Traction elevators shall be Hollister - Whitney Elevator Company equipment.

Freight Elevator Series GFM-T

ELEVATORS, LULAS AND PLATFORM LIFTS

Machine-roomless holeless hydraulic elevator

Telecommunication Spaces

3M Intelligent Return Plus and Sorter System SL. Architect/Contractor's Package

design and planning guide

INCLINATOR ELEVETTE HOME ELEVATOR. America s most customizable brand

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

V1504 Planning Guide Dec. 2006

Communications Page 1 of 9

Cavity Design and U-Channel Relationship

Typical Finished Basement Details

SECTION SECTIONAL OVERHEAD DOORS

A. Product Data shall be provided for each type of product indicated.

UNIVERSITY OF ALASKA FAIRBANKS DIVISION 14 - CONVEYING EQUIPMENT DESIGN STANDARDS SECTION

PHYSICAL FACILITIES Consultant s Handbook Division 27 COMMUNICATIONS 0000 COMMUNICATIONS

SECTION SECTIONAL OVERHEAD DOORS


Electric Service Standards

UNIFIED FACILITIES CRITERIA (UFC) ELEVATORS

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

Training Certification Categories

SECTION HYDRAULIC ELEVATORS

The Canadian Electrical Code (Saskatchewan Amendments) Regulations, 1999

Design Guidelines Technology

A/E Design Deliverable Checklist

SST-II HYDRAULIC BI-FOLD SPECIFICATIONS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

PURCHASE CONTRACT FLA15-

DESIGN AND CONSTRUCTION STANDARDS. Section 2: Standards for Specific Categories of Work. Laboratory Standards

Three-sided barrier compliant to DIN EN ISO Depending on location, design also as wind protection. Clear height (DH) Three-sided barrier

Westgate Entrematic, Parking Security Gates Section OVERHEAD SECURITY GATE Prepared by: Digicon Information Inc. Page 1

HERMIT S REST GRAND CANYON NATIONAL PARK BUILDING CODE REVIEW

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

1. American Architectural Manufacturers Association (AAMA): 2. American Society of Mechanical Engineers (ASME):

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

FOUR FOLD DOORS-WITH SINGLE OVERHEAD MTD OPERATOR

Fairfax County, Virginia

FREIGHT ELEVATOR. Safe and reliable control system. Variable Voltage Variable Frequency (VVVF) traction machine. Wide door opening

SUGGESTED SPECIFICATION SECTION ENTRANCE FLOOR MATS AND FRAMES

INDUSTRIAL GUARDRAIL SYSTEMS

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

Vertical Transportation Planning Retail/Mixed-Use

2007 Title 24 Accessibility Code Updates and ADA Issues

Building Regulations; Construction 11

MACHINE ROOM-LESS PERFORMANCE IN A HYDRAULIC ELEVATOR HOISTWAY. KONE EcoSpace

STREET LIGHTING. Springville City Power standard street lights will be installed in accordance with Springville City Power's Line Extension Policy.

Elevator Technology AGILE. Destination Controls

BRADDOCK ROAD YOUTH CLUB

SECTION IMPACT RESISTANT WALL PROTECTION

A/E Design Deliverable Checklist

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

SECTION COOLING TOWER

BASEMENT FINISH CONSTRUCTION PLANS REFERENCE: 2015 INTERNATIONAL RESIDENTIAL CODE. PERMITS

Priority 2 Access to Goods & Services

MINIMUM SPECIFICATIONS

Wine Storage Models 427G and 427RG Design Guide

800 Series Aluminum Overhead Doors, by Northwest Door Section ALUMINUM SECTIONAL DOORS Digicon Information Inc.

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

GLASS WALL SPECIFICATIONS

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

HD-Slide Series 2001 Heavy Duty Aluminum Sliding Door System with Electric Belt Drive Operator

KONE Talo 610 KONE Talo 710

CONSTRUCTION TRADES LABORATORY September 30, 2010

Universal Design Standards

THOMAS JEFFERSON UNIVERSITY HOSPITAL STANDARD OPERATING PROCEDURE FOR THE BUILD OUT OF TELECOMMUNICATIONS ROOMS AND ASSOCIATED SPACES

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

Power Zone Center. Your solution for power distribution and control systems

Effective June, Eaton-Durham Model # UTRS223ACH. Siemens, Model # SUAS877-PG. (or Landis & Gyr # UAS877-PG) Milbank. Model # U1980-O.

adaptable 2014 CONCEPT MODULAR PREFAB - MODULI ABITATIVI PREFABBRICATI

Geberit Duofix. Need a frame for every application? There s a Geberit for it.

DIVISION 14 CONVEYING SYSTEMS

A. Access doors and frames are part of an access door and frame allowance.

A. Submit the following in addition to the standard requirements.

Acousti-Seal Encore Paired Panel (10650) Operable Partitions

2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

SPECIFICATION FOR THE DEVELOPMENT OF LPA CLEAN ROOM INFRASTRUCTURE Description of work

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.

Machine Roomless Systems

Full-Cab A18.1/B355 Lifts An Alternative to LU/LA Elevators

SECTION CHAIN-LINK FENCES AND GATES 02821/1

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Transcription:

Creating An Accessible World ELVORON LU/LA ELEVATOR DESIGN AND PLANNING GUIDE www.garaventalift.com

Please note: Dimensions provided in this Guide are for REFERENCE ONLY and should not be used for site preparation or construction.

Table of Contents What is a LU/LA Elevator?... 4 Design Assistance... 4 Finishes... 4 How It Works... 5 Hoistway... 6 Construction of Pit... 7 Overhead Clearance (Refuge Space)... 7 Pit Lighting... 7 Loading Diagram... 8 Car Sizes & Configurations... 9 Layouts & Clearances... 10 Operating Controls... 16 Car Operating Panel (COP)... 16 Hall Stations... 16 Car Direction Lantern... 16 Doors - Entrance and Car Doors... 17 Door Details Masonry Walls... 18 Door Details Wood and Drywall Walls... 19 Technical Information... 20 Machine Room Requirements... 21 Machine Room Layouts... 22 Mains Power Requirements... 23

What is a LU/LA Elevator? The Elvoron LU/LA (Limited Use Limited Application) elevator is a cost effective way to transport the public from one landing to another. A LU/LA elevator is a power passenger elevator in which the use and application is limited by size, capacity, speed and rise. The Elvoron LU/LA elevator provides a code compliant automatic elevator with a variety of platform configurations and can service up to 6 landings. The wide selection of cab finishes and options ensure that it will blend into any setting. What is Limited about a LU/LA elevator? Travel 25 feet (7.6 meters) (check the regulations for your jurisdiction) Speed 30 fpm (0.15 m/sec) nominal Maximum Platform Size 18 square feet (1.67 square meters) Maximum Capacity 1400 lbs (635 Kg) Why a LU/LA Elevator? Cost Effective - LU/LA elevators are much more cost effective than a regular passenger elevator. Application - The LU/LA elevator is intended to be used in low rise buildings with low occupancy, where a full passenger elevator is not required. Its application in buildings is self limiting due to the restricted travel, speed, capacity and size. Meets ADA Requirements (USA) - The Elvoron LU/LA elevator meets the requirements of the Americans with Disabilities Act and most other Accessibility Codes and Requirements. Design Assistance With over 40 years of experience, Garaventa Lift has the expertise to overcome almost any design challenge you face. Please call our Design Hotline. 1-800-663-6556 or 1-604-594-0422 Finishes Your Elvoron elevator will be a key feature in your building. Interior design and finish are important considerations. We offer a variety of attractive and durable wall and ceiling finishes. If you re looking for something a little different, our custom shop can design an elevator to fit your vision. All Elvoron cars are supplied with basic plywood floors ready for installation of your preferred flooring material, as supplied by others. Car Walls Car walls are covered in Laminate Panel Sections Fire rated, tough, easy to clean and offered in a choice of 8 standard colors. Custom laminates are also available. Car Wall Trim Car Wall Trim separates the car wall panels and adds the finishing touch to your elevator cab. The standard trim is available in black or white. Custom colors and stainless steel trims are optional. Entrance Door and Car Doors Like a commercial elevator, the Elvoron LU/LA is equipped with two-speed horizontal sliding landing entrances and car doors. The car doors are finished to match your car wall trim. The landing entrance doors are primed and ready to be painted to match your building décor. All doors can be supplied in brushed stainless steel. Ceiling and L.E.D. Lighting All Elvoron LU/LA s are equipped with four recessed low-voltage L.E.D. lamps that illuminate automatically when the doors open. Ceiling choices are white, black, stainless steel or custom. White lamps are fitted into white ceilings and black into all other options. Chrome lamps are optional. Custom Car Finishes Your car interior can be customized to whatever unique design best suits your building project. Our custom shop offers a wide variety of wall, ceiling and fixture alternatives. We can also create elegant stainless steel and glass cars (panoramic). Handrail All Elvoron cars are equipped with one brushed stainless steel handrail on the control wall. Additional handrails can be mounted on the other car walls. ELVORON LU/LA Design & Planning Guide 37161-O-DP -4-

How It Works -5- www.garaventalift.com

Hoistway The walls of the elevator hoistway can be constructed of wood, poured concrete or concrete block. The wall behind the cylinder and guide rails must be load bearing and able to withstand the loads imposed by the elevator. The cylinder and guide rails are mounted to the wall with steel brackets. These rail brackets are fastened to the load bearing wall at regular intervals. The rail bracket spacing is determined during the design phase. The rail brackets are generally every 4 apart, measured vertically, depending on the load capacity, size of cab and travel height. Please see final elevator shop drawings for actual locations. All the walls of the hoistway, especially the wall behind the rails and the entrance walls, need to be flush and plumb from floor to ceiling to within +/- 1/8. This is to allow for the required running clearances. No light is required at the top of the hoistway as the car top is equipped with a standard caged light fixture for use by the mechanic during his maintenance visits. A light is required in the pit (see Construction of Pit for details). Rail Brackets attached to wall - locations indicated on shop drawing ELVORON LU/LA Design & Planning Guide 37161-O-DP -6-

Construction of Pit The pit must be the same width and length as the hoistway. The majority of the weight of the lift is borne by the plunger (ram). Reactions are indicated on each project s shop drawings. A minimum 14 (355 mm) pit is required. Overhead Clearance (Refuge Space) 135 (3429mm) is required above the upper landing level finished floor to the ceiling above to meet the refuge space required by code. On existing construction, a car top prop can be used to reduce the overhead to 114 (2895 mm). A pit ladder is required only if the pit depth exceeds 35 (900mm). Consult your Garaventa Lift representative for details as changes to finished hoistway are required. Pit Lighting A pit light and GFI duplex receptacle, supplied by the General Contractor, are required in the pit of your Elvoron LU/LA for use by the mechanic during his maintenance visit. Consult Garaventa Lift dealer for location and routing of conduit. Habitable space below hoistway will require the pit to be increased in depth to a minimum 16 (406mm) to accommodate the required buffer springs. It is preferable to fill concrete blocks with concrete Typical construction shown: For alternate construction methods (wood or steel stud walls), refer to a structural engineer to ensure construction method will support the loads shown on the loading diagram, page 8. Dimensions shown are for REFERENCE ONLY and should not be used for site preparation or construction. -7- www.garaventalift.com

Loading Diagram REFER TO JOB- SPECIFIC DRAWINGS FOR RAIL BRACKET LOCATIONS ELVORON LU/LA Design & Planning Guide 37161-O-DP -8-

Car Sizes & Configurations The Elvoron LU/LA is available in 5 different configurations to suit your building. Each configuration has specific car sizes. Limited custom car sizes are available - please contact Garaventa Lift. Style 1R Style 1L Style 2 Style 3 Style 4 Style 1L & 1R Car sizes: 48 x 54 (1220 x 1372 mm) 42 x 60 (1067 x 1524 mm) Style 2 Car sizes: 48 x 54 (1220 x 1372 mm) 42 x 60 (1067 x 1524 mm) Style 3 & 4 Car sizes: 51 x 51 (1295 x 1295 mm) -9- www.garaventalift.com

Layouts & Clearances 48 x 54 Cab - Style 1L * *66 may be feasible. Consult with your local Garaventa Lift Representative. Style 1L shown - Dimensions apply to both Style 1L & 1R Dimensions shown are for REFERENCE ONLY and should not be used for site preparation or construction. ELVORON LU/LA Design & Planning Guide 37161-O-DP -10-

Layouts & Clearances 42 x 60 Cab - Style 1L * *66 may be feasible. Consult with your local Garaventa Lift Representative. Style 1L shown - Dimensions apply to both Style 1L & 1R Dimensions shown are for REFERENCE ONLY and should not be used for site preparation or construction. -11- www.garaventalift.com

Layouts & Clearances 48 x 54 Cab - Style 2 * *66 [1676] may be feasible. Consult with your local Garaventa Lift Representative. Dimensions shown are for REFERENCE ONLY and should not be used for site preparation or construction. ELVORON LU/LA Design & Planning Guide 37161-O-DP -12-

Layouts & Clearances 42 x 60 Cab - Style 2 * *66 [1676] may be feasible. Consult with your local Garaventa Lift Representative. Dimensions shown are for REFERENCE ONLY and should not be used for site preparation or construction. -13- www.garaventalift.com

Layouts & Clearances 51 x 51 Cab - Style 3 Dimensions shown are for REFERENCE ONLY and should not be used for site preparation or construction. ELVORON LU/LA Design & Planning Guide 37161-O-DP -14-

Layouts & Clearances 51 x 51 Cab - Style 4 Dimensions shown are for REFERENCE ONLY and should not be used for site preparation or construction. -15- www.garaventalift.com

Operating Controls The controls of the Elvoron LU/LA are the same as would be found on a commercial elevator. Operation is fully automatic. Braille Markings for the COP, Hall Stations and Hall landings are included as standard equipment. Car Operating Panel (COP) The Elvoron LU/LA COP is equipped with a digital floor indicator, illuminated floor buttons, alarm button, door open and door close buttons and a keyed emergency stop switch. An optional integrated hands free phone is available. Hall Stations The Hall Station buttons illuminate when pushed. The push button itself is always made of stainless steel for maximum durability. For increased safety and security, an optional key switch allows the entire elevator to be deactivated. Car Direction Lantern Mounted in the car to the car slam post opposite the COP, the Car Direction Lantern is an audio and visual signaling device that indicates direction of travel and arrival at the floor. Hall Stations Car Operating Panel (COP) Car Direction Lantern ELVORON LU/LA Design & Planning Guide 37161-O-DP -16-

Doors - Entrance and Car Doors The Elvoron LU/LA uses commercial elevator entrance and car doors. When open the doors provide a 36 (915mm) x 80 (2032mm) clear opening. They are two-speed horizontal doors and are equipped with full height photo-electric presence/obstruction sensors. The doors have an hour and a half fire rating. The car doors are finished to match your car wall trim and the entrance doors are primed and ready to be painted to match your building décor. All doors can be supplied in brushed stainless steel. -17- www.garaventalift.com

Door Details - Masonry Walls Garaventa Lift recommends that the walls on the entrance side of the hoistway be left open until the door frames are set. Or a rough opening can be left to accommodate for the doors to be placed. This allows the doors to be aligned with the centerline of the car. Contact your local authorized Garaventa Lift representative for further details. See Layouts & Clearances for door centerlines ELVORON LU/LA Design & Planning Guide 37161-O-DP -18-

Door Details - Wood and Drywall Walls Garaventa Lift recommends that the walls on the entrance side of the hoistway be left open until the door frames are set. This allows the doors to be aligned with the centerline of the car. Contact your local authorized Garaventa Lift representative for further details. See Layouts & Clearances for door centerlines -19- www.garaventalift.com

Technical Information Car Sizes: 48 x 54 (1220 x 1372mm) Style 1 + 2 only 42 x 60 (1067 x 1524mm) Style 1 + 2 only 51 x 51 (1295 x 1295mm) Style 3 + 4 only Rated Load: Standard: 1400 lbs (635 kg) Speed: Standard: 30 fpm (0.15 m/s) nominal speed Optional*: 40 fpm (0.2 m/s) Travel Range: Standard: 25 ft (7.6 meters) Optional*: 30 ft (9.1 meters) Stops: Up to 6 stops Pit Depth: Recommended pit depth of 14 (355 mm), Pit Prop standard equipment with elevator. 16 if Buffer Springs are required. Overhead Clearance (Refuge Space): 135 (3429mm) min. standard overhead *114 (2895mm) min. overhead in existing construction with the use of a Car Top Prop Safety Features: Uninterruptible Power Supply (UPS) emergency backup power lowering system, emergency manual lowering valve, safety brake system, 2 speed door operators with integral gate switch, automatic bidirectional floor leveling, emergency alarm button in car, emergency keyed stop switch in car, overspeed valve, final limit switch and low oil protection timer circuit Unique Standard Features: Braille markings, car direction lantern comes with audio and visual signals, full height photo-electric presence/obstruction sensors, automatic home park feature Code Compliance ASME A17.1, Section 5.2 LU/LA Elevators CSA B-44, Section 5.2 LU/LA Elevators ADA (Americans with Disabilities Act) Popular Options: Integrated hands free telephone, custom car finishes, additional handrails, Fireman service (Phase 1), car top prop, buffer springs (increases your pit depth), keyed hoistway access. Drive System: 1:2 Cable Hydraulic, Heavy Duty car sling with roller guide shoes running on 8 lb. per foot steel T-rails, Quiet submersed pump and motor, Factory pre-set and tested 2-speed valve for smooth start and stop. Power Supply: Elevator: Standard: 208 VAC three phase Optional: 230 VAC single phase Lighting: 110 VAC single phase, 15 amps Controls: Fully automatic push button operation, PLC Controller, integrated self-diagnostics. Digital floor indicator in car, automatic car lighting upon entry, illuminated push buttons, car arrival lanterns in car door jamb. Doors: 36 x 80 (914 x 2032mm) two-speed horizontal sliding hoistway and car doors with 1.5 hour fire rating *Contact Garaventa Lift ELVORON LU/LA Design & Planning Guide 37161-O-DP -20-

Machine Room Requirements In order to meet the code requirements, the hydraulic pump unit, GFI duplex receptacle and fused disconnect switches (elevator lighting) must be located in a dedicated machine room with a minimum overhead of 7 (2134 mm). Adequate working space in the machine room includes, clearance in front of the pump unit and the proper location of the light switch and disconnect switches. Please refer to your job specific shop drawings or contact your local authorized Garaventa Lift representative for further details. The optimum location for your machine room is at the lowest level of the building, adjacent to the hoistway, preferably on the same side as the guide rails. The dimensions of the pump unit are 30 wide x 19 ½ deep x 66 ¼ high (762 x 495 x 1683 mm). The controller pump assembly can be located up to 25 (7.6 m) from the hydraulic jack. The controller and pump tank can be separated from each other by a maximum of 10. Please contact your Local Garaventa Lift representative for specific Machine Room Code Requirements. -21- www.garaventalift.com

Design Hot Line: 1-800-663-6556 or +1-604-594-0422 Machine Room Layouts CANADIAN MACHINE ROOM PLAN LIGHT SW. & DUPLEX GFCI RECEPTACLE 59.13 (1500) 39.38 (1000) 39.38 (1000) 30 (762) 230V-1PH 60Hz 40Amp DISCONNECT FUSED 30A (NOM.) clw AUXILLIARY CONTACT. 120 1PH 60Hz DISCONNECT FUSED15A POWER AND OIL LINE SLEEVES TO HOISTWAY 19.5 (495) 43.25 (1100) MACHINE ROOM HEIGHT IS MIN. 79" OR 2m CLEAR ABOVE FINISHED FLOOR USA MACHINE ROOM PLAN LIGHT SW. & DUPLEX GFCI RECEPTACLE 55.5 (1410) 36 (914) 36 (914) 30 (762) 230V-1PH 60Hz 40Amp DISCONNECT FUSED 30A (NOM.) clw AUXILLIARY CONTACT. 120 1PH 60Hz DISCONNECT FUSED15A POWER AND OIL LINE SLEEVES TO HOISTWAY 19.5 (495) 40 (1017) MACHINE ROOM HEIGHT IS MIN. 79" OR 2m CLEAR ABOVE FINISHED FLOOR Please contact your Local Garaventa Lift representative for specific Machine Room Code Requirements. ELVORON LU/LA Design & Planning Guide 37161-O-DP -22-

Machine Room Layouts (Continued) Two dedicated PVC sleeves, at least 3 (76 mm) in diameter, will be required between the hoistway and the machine room, one sleeve for the hydraulic hose and one for the electrical conduit. This is to enable the installers to make the connection between the cylinder and the pumping unit. The sleeves should enter the hoistway at either corner of the support wall. Contact your local authorized Garaventa Lift representative for code specific requirements and further details. Lighting: The machine room must be provided with at least 100 lx lighting over the pumping unit and disconnect switches. The fused disconnect switch rating and fuse rating for the lift will be shown on the shop drawings for your project. At least one GFCI duplex receptacle connected to a 15 amp branch circuit shall be installed in the machine room. Ventilation Requirements: No special requirements. The elevator drive unit will generate approximately 3200 BTU per hour under normal operating conditions. Recommended temperature for elevator equipment is 50º 90º F (15º 32º C) and 5% 90% non-condensing. Mains Power Requirements The standard motor on the pump can be ordered to suit either three phase or single phase power. Standard: 208 VAC Three phase 30 amps Optional: 230 VAC Single phase 40 amps Emergency Battery Lowering In case of a power outage the elevator is provided with a second power source that allows the car to be lowered to the lowest landing. While descending, the car can stop and the passenger can exit the car on any landing along the way. Electrical Disconnects: In the machine room you will need to provide two lockable fused disconnects one 15 amp for lighting and one 40 or 30 amp for the pump unit (depends upon site voltage). Disconnect switches should be located on the strike (lock) side of the machine room door. In accordance to the electrical code, you must provide a minimum of 36 (915mm) in the United States and 39 ⅜ (1000mm) in Canada of working space in front of each disconnect switch. The disconnect switch for the pump unit requires an auxiliary contact. -23- www.garaventalift.com

Creating An Accessible World Printed in Canada 37161-O-DP Garaventa Lift. As we are continuously improving our products, specifications outlined in this brochure are subject to change without notice. Authorized Garaventa Lift Representative www.garaventalift.com