On-Line. User s Guide SPE CARTRIDGES. for Rapid Cleanup and Extraction of Analytes

Similar documents
* Strata-X is patented by Phenomenex, Inc. Oasis is a registered trademark of Waters Corporation. Phenomenex is not affiliated with Waters

MassPREP On-Line Desalting Cartridge

Clarity BioSolutions For Synthetic DNA/RNA Advance Your. Oligonucleotide Work. From Sample Preparation to Analysis and Purification

EtG / EtS Analysis UCT INNOVATION THROUGH CHEMISTRY FORENSICS

Protein-Pak Hi Res HIC Column and HIC Protein Standard

Guide to Trap Cartridge Care and Use

Bivalirudin Purification:

Improved SPE for UPLC/MS Determination of Diquat and Paraquat in Environmental

EASY-Spray Columns. Guidance for column set up and installation Tips to maximize column lifetime

Econo-Pac High Capacity Ion Exchange Cartridges, 5 ml Instruction Manual. Catalog Numbers , ,

Determination of Monocrotophos, Diazinon, Malathion, EPN, and Methamidaphos from Aqueous Samples Using Atlantic HLB SPE Disks

Converting a Liquid-Liquid Extraction Method for Vitamin D to a 96-Well Plate Supported Liquid Extraction Format

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

Application Note. Author. Abstract. Environmental. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

BÜCHI Labortechnik AG

New Core-Shell Technology

Agilent MetaCarb Ca PLUS Carbohydrate Column Ca ++ Form User Manual Part No. A5205

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

A Modular Preparative HPLC System for the Isolation of Puerarin from Kudzu Root Extracts

Scaling from Analytical to Preparative Chiral Chromatography While Balancing Purity, Yield, and Throughput under HPLC and SFC Conditions

R R Innovation Way P/N SECKIT-7830 Newark, DE 19711, USA Tel: Fax: Website: Published in November 2013

ENHANCED MS WITH THE TURN OF A KEY

Empore. Solid Phase Extraction Cartridges. Technical Information. Product Description. Product Characteristics. Sorbents Available

Fast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover

Instructions for Capillary Electrophoresis Peptide Analysis Kit

Physical Stability of a Silica- Based Size Exclusion Column for Antibody Analysis

B r i n g i n g e x p e r t s t o g e t h e r TELOS neo Polymeric Solid Phase Extraction Columns Simple and Effective SPE

Development of a Clinical Research Method for the Measurement of Testosterone. Dihydrotestosterone

Preparative HPLC is still the

Accucore. Ultimate Core Performance LC Column Technology to Maximize Your Investment. Dave Jarzinski. October 2011

Genotoxicity is the property of a compound

Tyler Trent, Applications Sales Specialist; Teledyne Tekmar Page 1

Let s Clear the Air...

CAMAG TLC-MS INTERFACE 2

Sample Prep - Solid Phase Extraction

Concentration of Human Hormones in Drinking Water Using Solid Phase Extraction and Analysis by High Performance Liquid Chromatography

Thermo Scientific TSQ Quantum Access MAX

MS Certified Vials. Pre-cleaned and certified vials for mass spectrometry

ph Flexibility Expands Robustness and Reproducibility

Extraction and Analysis of Neonicotinoid Pesticides using QuEChERS Approach

Analysis of Glyphosate and AMPA in Environmental Water Samples by Ion Chromatography and On-Line Mass Spectrometry with Minimal Sample Preparation

ZORBAX StableBond HPLC Columns

Ultrahydrogel Columns

Determination of Oxalate and Other Anions in Bayer Liquor Using Ion Chromatography

ACQUITY UPC 2 BEH, CSH, and HSS Columns

Automated Online SPE for LC/MS/MS Analysis of Trace Organic Contaminants in Water Using the Agilent 1290 Infinity Flexible Cube Module

Automated Solid Phase Extraction of PAH Compounds Utilizing the SPE-DEX 5000

Automated Real-Time Determination of Bromate in Drinking Water Using LC-ICP-MS and EPA Method Application

TechnicalNOTE METABOLYNX EXACT MASS DEFECT FILTER: RAPIDLY DISCRIMINATE BETWEEN TRUE METABOLITES AND FALSE POSITIVES INTRODUCTION

CHROMATOGRAPHY/MASS SPECTROMETRY

Analysis of 16 Pesticide Residues in Broccoli Using CarbonX dspe QuEChERS AOAC Kits Using GC/MS

RAM Direct Injection. (Restricted Access Media) A Tool for the Separation of Small Molecules in the Presence of Large Biomolecules

Development of a Fast and Cost-Effective Multi-Residue Method to Determine Pesticides in Tobacco by LC/MS/MS

Improved Peptide Maps Using Core-Shell Media: Explaining Better Biopharmaceutical Applications With Kinetex C18 Columns

SFC Säulen für analytische und preparative Anwendungen

An Automated System for At-Line Process Analysis of Biopharmaceutical Fermentation Reactions

Performance. Reliability. Productivity. Consumables

Preparative HPLC: Factors and Parameters that Directly Affect Recovery of Collected Fractions

Two-Dimensional LC Protein Separation on Monolithic Columns in a Fully Automated Workflow

PRODUCT MANUAL FOR THE. ELECTROLYTIC ph MODIFIER (EPM) EPM, P/N

Fast Preparative Column Liquid Chromatography (PCLC)

DETERMINATION OF PROTEIN BINDING BY UPLC/MS/MS

Application Note. Author. Abstract. Biotherapeutics and Biologics. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany

Phenyl Sepharose High Performance

Method Translation in Liquid Chromatography

BioSep- SEC-S. Tired of paying high prices? Irritated with slow delivery times? Frustrated by irreproducible results?

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

Flexibility with. Preparative HPLC

AppNote 5/2006 ABSTRACT

Investigation of Solid Phase Microextraction as an Alternative to Dried Blood Spot

A Fast and Robust Linear ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge Variant Analysis

A Unique LC-MS Assay for Host Cell Proteins(HCPs) ) in Biologics

Fundamentals and Techniques of Preparative HPLC. Parto Zist Behboud Tel: 42108

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

Optimization of Volatile Petroleum Hydrocarbons Analysis by Automated Headspace Using Method Development Tools

Gas Chromatography Assignment Chem 543/443

Sepax Technologies, Inc.

Reversed Phase Solutions for the Analysis of Proteins, Peptides, and Oligonucleotides

G Sep Size Exclusion Columns

Method Development Considerations for Reversed-Phase Protein Separations

INTERNATIONAL JOURNAL OF PHARMACEUTICAL RESEARCH AND BIO-SCIENCE

Thermo Scientific EASY-nLC 1200 System. Leading in simplicity. and performance

Dionex Eluent Generator Cartridges

BabyBio S BabyBio Q BabyBio DEAE

Generating Automated and Efficient LC/MS Peptide Mapping Results with the Biopharmaceutical Platform Solution with UNIFI

Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions

Low-level Detection of Ethanol, 1,4-Dioxane, and Other Oxygenates Using the Eclipse Purge-and-Trap Sample Concentrator

Application Note: Multi-Residue Pesticides in Fruit and Vegetables (9/16/08)

Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns

Key Words Q Exactive Focus, SIEVE Software, Biomarker, Discovery, Metabolomics

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Supplementary Material

Simultaneous in vivo Quantification and Metabolite Identification of Plasma Samples Using High Resolution QTof and Routine MS E Data Analysis

Martin Gilar Waters Corporation, Milford, MA, U.S. Origins of synthetic oligonucleotides impurities. Lab-scale isolation options

Phenyl Sepharose CL-4B

THE EFFECTS OF HEME FROM HEMOLYZED MATRIX ON THE STABILITY OF OCTREOTIDE IN K2 EDTA PLASMA. William Arthur Altizer

HiTrap Heparin HP, 1 ml and 5 ml

Transcription:

On-Line SPE CARTRIDGES for Rapid Cleanup and Extraction of Analytes User s Guide

What is the strata-x on-line SPE cartridge? The strata-x on-line cartridge combines the revolutionary benefits of the patent pending SPE sorbent strata-x: Strong π π retention mechanism for high recoveries of aromatic analytes Deconditioning resistant sorbent bed that can run dry without losing extraction ability Multiple retention mechanism gives enhanced selectivity for polar compounds Particle Size 25µm Pore Size 85Å Surface Area 800m 2 /g ph stability 1-14 Recommended Flow Rates 1-4mL/min Maximum Pressure 4000 psi With the benefits of on-line SPE: Simple to use cartridge that eliminates the dry down and reconstitution steps associated with conventional off-line SPE Easy to use format that allows for complete automation of the sample preparation process Reusable hardware that can be used in tandem with an LC column or in a stand alone format for fast sample cleanup 2

What should you expect from strata-x on-line cartridges? Extremely Rapid Method Development strata-x has π π, hydrophobic, and H-bonding retention mechanisms and can be used to extract acidic, basic and neutral compounds. The multiple retention mechanisms of strata-x combined with the ability to handle fast gradients equates to rapid SPE method development that provides high recoveries for a wide spectrum of analytes. Elimination of Storage Solvents strata-x is deconditioning resistant and will not lose extraction ability even if the sorbent runs dry. This unique feature means that the strata-x cartridge does not need to be stored in solvent after use. Reduced Sample Preparation Time The on-line format is easily automated, thus reducing the number of steps that are involved with traditional sample preparation. Samples are pretreated and then directly injected onto the strata-x cartridge for extraction. The typical analysis time for extraction can range from 1 to 3 minutes. Longer Column Lifetimes strata-x sorbent is extremely robust, resulting in long column lifetimes. This unique feature allows for the development of extremely rugged methods. In fact, strata-x can handle greater than 200 injections per cartridge. Phenomenex 3

Easy to Use Hardware The strata-x on-line hardware is a reusable stainless steel holder designed to accommodate 20mm x 2.0mm cartridges. This revolutionary holder is easy to use and can be quickly installed by the following steps: 1 2 Insert the cartridge in the male end of holder. Remember to note flow direction-the beige frit cap is the inlet end, and the black frit cap is the outlet end. Thread the female end onto the male end and hand tighten. Tighten the holder NO MORE THAN 1 /8 to 1 /4 turn with a standard 1 /2 and 1 /4 inch wrench. 3 4 Repeat this process to change a cartridge. Please make sure pressure DOES NOT EXCEED 4000psi and flow rate DOES NOT EXCEED 4mL/min. Inlet End (Beige) FLOW Outlet End (Black) 4

1 2 3 Additional Considerations To ensure efficient and reproducible extractions, it is advised that the user: Minimize tubing lengths Use 0.007 ID tubing or smaller Minimize the use of unions and other connectors Phenomenex 5

General Set Up On-line cartridges can be used in a stand alone fashion or in tandem with an analytical column. Both tandem and stand alone methods may employ very fast gradients. For methods that require MS detection, a 10:1 split is recommended so only 300-400µL/min enters the mass spectrometer. The extraction set up should include two pumps, cartridge column and analytical column (for tandem analysis), a detector such as a mass spectrometer, and a switching valve (general set up is illustrated below.) Schematic of On-line Set Up Load Position Pump 1 Elution Position Pump 1 Waste SPE Waste SPE Mass Spectrometer Pump 2 Column Mass Spectrometer Pump 2 Column 6

Recommended Starting Parameters for strata-x On-line Time Extraction Conditions Pump 1 (3mL/min) Pump 2 (1mL/min) Valve position 0 95% A : 5% B 95% A : 5% B Load position 0.5 95% A : 5% B Switch position Load to Elute 2.8 15% A : 85% B Switch position Elute to Load 3 95% A : 5% B 95% A : 5% B Load position Mobile Phase: A: 0.1% formic acid/water B: 0.1% formic acid/acetonitrile Injection: 50µL of diluted porcine plasma (1:1) Detection: Bruker Esquire 2000 Ion-Trap MS analyzer Source: ESI-Positive mode Scan Range: m/z 100-500 Run Time: 3 minutes (with analytical column) Run Time: 1.2 minutes (without analytical column) (1 minute gradient) Phenomenex 7

Extraction of Polar and Non-polar Compounds Ephedrine and Quinine x10 4 5 4 3 2 1 0 x10 5 1.0 0.8 0.6 0.4 Intensity Intensity EIC 0.0 0.5 1.0 1.5 2.0 2.5 min EIC Ephedrine 600pg on column Quinine 600pg on column O HN H HO OH H Lyophilized porcine plasma samples diluted 1:1 with water were spiked with the appropriate concentration of analyte. The strata-x on-line extraction method was used. Compound Log P Polarity Ephedrine 1.13 Polar Quinine 3.44 Non-Polar N N 0.2 0.0 0.0 0.5 1.0 1.5 2.0 2.5 min N 8

Rapid Cleanuup Extraction of Acyclovir x10 4 x10 5 Intensity Intensity On-line SPE Conditions Cartridge: strata-x 20 x 2.0mm cartridge plus holder Order No: 00M-S033-B0-CB Mobile Phase: A = water B = acetonitrile Flow Rate: Pump 1 3mL/min, cartridge Pump 2 1mL/min, analytical column Load: Pump 1 100% A (cartridge) Elution: Pump 2 80% B : 20% A (analytical column) HPLC Column: Luna 3µm NH 2 50 x 3.0mm Order No: 00B-4377-Y0 Mobile Phase: 80% B : 20% A Flow Rate: 1mL/min MS: Bruker Esquire 2000 Ion-Trap MS analyzer Source: ESI-Negative mode Scan Range: m/z 100-400 Sample % Recovery %RSD Note: NO buffers are Acyclovir 40ng/mL 92.4 4.4 used in this Acyclovir 20ng/mL 97.9 2.3 method Phenomenex 9

strata-x Ordering Information Traditional Screening strata-x Tubes 1mL (100/box) 3mL (50/box) 6mL (30/box) 30mg 60mg 200mg 500mg 100mg 200mg 500mg 8B-S100-TAK 8B-S100-UBJ 8B-S100-FBJ 8B-S100-HBJ 8B-S100-ECH 8B-S100-FCH 8B-S100-HCH Note: tube sizes not proportional nor actual size. High-throughput Screening 96-Well Plates (2/box) 5mg 10mg 30mg 60mg 8E-S100-NGB 8E-S100-AGB 8E-S100-TGB 8E-S100-UGB Rapid Screening On-line Extraction Cartridges (1/box) Order No. 00M-S033-B0-CB CH0-5845 Dimensions strata-x on-line extraction cartridge, 25µm, 20 x 20mm Cartridge holder, 20mm 10

Technical Notes Available Extraction of Acyclovir from Plasma using a strata-x On-line Cartridge (TN-009) Contact Phenomenex to Request a FREE Technical Note Today Extraction of Phenols from Water using strata-x (TN-001) Extraction of Nitroanilines from Water using strata-x (TN-003) Extraction of Acidic, Basic, and Neutral Compounds using strata-x (TN-004) Extraction of TCA s from Serum using strata-x (TN-006) Phenomenex 11

FREE Help is Available Phenomenex technical consultants are available to help with your SPE method development. Please feel free to contact us for SPE: Troubleshooting Converting Liquid/Liquid Extraction to SPE Technical Solutions Method Optimization strata-x products are available worldwide. strata-x products are patent pending products from Phenomenex. For the distributor in your country, contact Phenomenex USA, International Department. mail: tel.: fax: USA 411 Madrid Ave. Torrance, CA 90501-1430 USA (310) 212-0555 (310) 328-7768 info@phenomenex.com Puerto Rico 273 Sierra Morena, Suite #104 San Juan, Puerto Rico 00926 (800) 541-HPLC (310) 328-7768 info@phenomenex.com Canada 411 Madrid Ave. Torrance, CA 90501-1430 USA (800) 543-3681 (310) 328-7768 info@phenomenex.com United Kingdom Queens Avenue, Hurdsfi eld Ind. Est., Macclesfi eld, Cheshire SK10 2BN, England 01625-501367 01625-501796 ukinfo@phenomenex.com Germany Zeppelinstr. 5 63741 Aschaffenburg Deutschland 06021-58830-0 06021-58830-11 anfrage@phenomenex.com New Zealand P.O. Box 31-601 Milford Auckland New Zealand 09-4780951 09-4780952 info@phenomenex.co.nz Australia P.O. Box 264 Pennant Hills NSW 1715 Australia 1800-553-929 1800-553-923 info@phenomenex.com.au 2651_L