Optimizing Energy Use in a HealthCare Setting. Michael P. Della Barba Environmental Health & Engineering, Director of Commissioning

Similar documents
Existing Building Cx: Processes & Results A Cultural Journey. Barry Abramson Senior Vice President Servidyne

Low-Hanging Fruit Simple Steps Toward Energy Effective Building Operations

RETRO-COMMISSIONING: AN OWNER S LOOK AT THE TRUE COSTS AND RETURN ON INVESTMENT. Adam Renzi, PE

CHP Case Studies. Midwest CHP Application Center (MAC) .org (312) University of Illinois at Chicago Energy Resources Center UIC

Indiana University Glick Eye Institute. LEED Measurement & Verification Plan

No Cost/Low Cost Energy

Using EMIS to Streamline RCx Projects. Lia Webster, P.E.

George Bourassa, National Director, Commissioning Services Robert Bucey, Program Manager RETRO-COMMISSIONING

Opening a New Hospital: A Case Study Healthcare Commissioning and the Authority Having Jurisdiction

South Carolina Society for Hospital Engineers

Energy Reduction Strategy Through 2020

Low Cost Building Automation System for Small- and Medium- Sized Commercial Buildings

Marysville School District Resource Conservation Program. John Bingham Marysville S.D. Ray Burton Snohomish Co. P.U.D.

Retrocommissioning (RCx)

Fundamentals of Test & Balance for Engineers, Cx & Energy Providers Course Number: CXENERGY1619

City of Fort Collins Building Automation Systems Enhances Savings and Commissioning Efficiency Works Training

Condenser Water Heat Recovery"

For. Prepared For ANTHC DEHE

USGBC National Capital Region MasterClass Series: The Ins and Outs of Existing Building Commissioning Analysis Credit

Comprehensive Energy Audit For Kongiganak Health Clinic

The Energy Program Tricycle: Which Wheel Should You Put in Front?

ENERGY AND WATER CONSERVATION AND DEMAND MANAGEMENT PLAN

Example LEED-NC v2.1 Energy & Atmosphere Credit 1 Submittal

Benchmarking EPA Portfolio Manager and Energy Star Certification

Texas Hospital. Central Plant Redesign. Central Utility Plant SECOND PLACE HEALTH CARE FACILITIES, EXISTING 2013 ASHRAE TECHNOLOGY AWARD CASE STUDIES

LEED Commissioning and Actual Energy Use. John Kokko, P.Eng. LEED A.P. Vice President Enermodal Engineering

Hotels: Water and Energy

Energy Saving Calculations for Recommissioning and Design

ELIAS BOUDINOT ELEMENTARY SCHOOL Pearl and Ellis Street, Burlington NJ 08016

Energy Report - February 2008

Recreation Centers of Sun City West R.H. Johnson Campus

Klatt Elementary School

An Evaluation of ComEd s Retro- Commissioning Program

ENERGY AUDIT. 123 Main Street Mississauga, Ontario. January 1, Report To: Mr. John Smith Smith Printing Company.

MBCx: The Next Wave of Energy Savings in Utility Incentive Programs

Comprehensive Energy Audit For. Kiana Lift Station

Comprehensive Energy Audit For. Quinhagak Utility Building

Custom Application 2018 Retrofit Program

5/7/2012. Agenda. What is High Performance? Ensuring a Successful Transition to Sustainable, High-Performance Operations

Incorporating Uncertainty Analysis into a Building Retrofit Analysis Using OpenStudio and EnergyPlus

Energy Benchmarking Report for Mill Pond Elementary School Lanoka Harbor, NJ

Air Source Heat Pumps in the Commercial Market. Thursday, February 5, :00-10:30 a.m.

Full-Scope Commissioning for High-Quality Buildings

Ground-Coupled Heat Pump And Energy Storage

Case Study for Fortune 500 Telecom: Retrofitting Pneumatic Controls for Energy Efficiency

Mission Critical Commissioning for Healthcare Facilities

Application of Advanced Energy Technologies

Energy Efficient Buildings: Realizing Money and Energy- Saving Opportunities

Giuseppe Giordano Founder & CEO

Energy Benchmarking Report for LaMonte Elementary School Bound Brook, NJ

Premium Sample Reports

Smart Thermostats: Paving the Way for Smart EM&V

Net Zero Building Commissioning. Phillip Saieg, CEM, LEED AP O+M Josh Harwood

Comprehensive Energy Audit For Community Building

DCAS Energy Management. August 15, 2014 Ellen Ryan & Mike Dipple

Bryant University s Energy Guidelines for Sustainability

DIRECTIONAL-BORE GROUND SOURCE HEAT PUMP FIELD REPORT

Comprehensive Energy Audit For Kiana Water Treatment Plant

Conference For Catholic Facility Management. Track 8 Making Cents of Financing and Building in this Economy

Comprehensive Energy Audit For. Kake Water Treatment Plant and Water Dam

David H. Koch Institute for Integrative Cancer Research Senior Capstone Mechanical Option. Proposal

THE HOSPITAL FOR SICK CHILDREN ENERGY CONSERVATION AND DEMAND MANAGEMENT PLAN

Union College Combined Cooling, Heat and Power Project

For. Prepared For. June 11, 2012 ANTHC DEHE

The Mirenda Center for Sports, Spirituality, and Character Development

Integrated Energy Audit:

Waste Heat Recovery as an Alternative Energy Source

Ron Wilkinson October 12, 2016

Whole Building Assessment Initiative

Comprehensive Energy Audit For CMTRS Building

Plug Loads: Identifying opportunity in a quickly growing and oft neglected end-use. Phil Jordan PECI

ENERGY AUDIT FINAL REPORT CEG PROJECT NO. 9C08134

YWCA 1503 S. Denver Tulsa, Oklahoma 5/18/2010 Performed By

How to Reduce Energy Use in Your Labs by Up to 50%

Reducing Peak Energy Demand: The Hidden Benefit of Cool Roofs

Energy Management Plan

SEEK COMFORT ACHIEVE PERFORMANCE Z SMITH ESKEW+DUMEZ+RIPPLE

New Jersey Board of Public Utilities Clean Energy Incentive Program

Strategic Cost Management in Black Tea Processing

Sustaining Our Operation in a Changing World. Michael Younis October

CONCORD ENGINEERING GROUP 520 SOUTH BURNT MILL ROAD VOORHEES, NJ TELEPHONE: (856) FACSIMILE: (856)

Pumped hydro Storage Plants

Project Report: SunMaxx Commercial Case Studies

Harley-Davidson Museum Milwaukee, WI. Jonathan Rumbaugh, BAE/MAE Mechanical Option. Advisor: Dr. William Bahnfleth

Application of a cooling tower model for optimizing energy use

Steps to Making Existing Commercial Buildings Become High Performance. Jim Bochat

Advantages of Financing Continuous Commissioning As An Energy Conservation Retrofit Measure

DLR Group is ranked #1 by ARCHITECT, the official publication of the American Institute of Architects, in its 2012 ARCHITECT 50 ranking of U.S.

Centre for Addiction and Mental Health Queen Street Campus Energy Conservation and Demand Management Plan

Retro Commissioning Evaluation in Massachusetts NSTAR Perspectives. Erik C. Mellen, Senior Research Analyst Northeast Utilities

REPORT DOCUMENTATION PAGE

Financial Validation Assessment Report

Tools to Design, Implement and Monitor Energy Efficiency Measures

Value of Air Source Heat Pumps in Light of Variable Energy Prices. Jeff Haase. Energy Design Conference February 27, 2013

Building Trek: The Next Big Thing in Energy Performance Course Number: CXENERGY1623

Sample. Annual Energy Consumption Report. and. Monthly Energy Consumption Report. for. Zachry Engineering Center

ROUTINE MAINTENANCE EMERGENCY SERVICES EQUIPMENT REPAIR

GETTING TO EFFICIENT BUILDINGS

Cx at Penn State: A Program for Every Situation

Transcription:

Optimizing Energy Use in a HealthCare Setting Michael P. Della Barba Environmental Health & Engineering, Director of Commissioning

AIA Quality Assurance The Building Commissioning Association is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credit(s) earned on completion of this program will be reported to AIA/CES for AIA members. Certificates of the Completion for both AIA members and non-aia members are available upon request. This program is registered with AIA/CES for continuing professional education. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA of any material of construction or any method or manner of handling, using, distributing, or dealing in any material or product. Questions related to specific materials, methods, and services will be addressed at the conclusion of this presentation. 2

Session Learning Objectives At the end of this session participants will be able to: 1. Identify and use unique systems approaches when undertaking an energy optimization project 2. Leverage energy savings approaches specific to in healthcare EBCx 3. Apply the latest OR pressurization codes and standards for occupied and unoccupied modes 4. Test, commission and optimize pressure dependent spaces 3

Today s Objectives Healthcare Today Define Energy Optimization Outline the Optimization Process Applying the Process Expected Results

EH&E s Healthcare Experience Hands-on experience managing Joint Commission and EH&S programs Currently staffs the Department of Environmental Affairs at Brigham and Women s Hospital Longstanding EH&S partnering with numerous teaching and community hospitals Consulting relationship with 100+ hospitals nationwide Commissioning

Exemplary Healthcare Projects Children s Hospital Boston PCRA Support Brigham and Women s Hospital EHS/PCRA Support Dana-Farber Cancer Institute Construction Support St. Jude Children s Research Hospital OSHA Gap Analysis Beth Israel Deaconess Medical Center Construction and EH&S Children s Medical Center of Dallas Construction

Energy Consumption Comparison Source(s):EIA, 2003 Commercial Buildings Energy Consumption and Expenditures: Consumption and Expenditures Tables, Oct. 2006 Table C1a

Average Electricity end use profile for HealthCare Facilities Source(s):EIA, 2003 Commercial Buildings Energy Consumption and Expenditures: Consumption and Expenditures Tables, Oct. 2006 Table C1a

Average Natural Gas end use profile for HealthCare Facilities Source(s):EIA, 2003 Commercial Buildings Energy Consumption and Expenditures: Consumption and Expenditures Tables, Oct. 2006 Table C1a

Energy Consumption - Healthcare Energy use intensity (EUI) for Hospitals is approximately 250 kbtu/ft2 The EUI of Hospitals is nearly 3x that of typical commercial buildings US HealthCare facilities spend $8.8 billion/year on Energy Hospitals use an average of 600,000 MMBtu

Definitions Re-commissioning (Re- Cx) Extensive systemic review of previously commissioned building. Maintains the value that Cx originally provided.

Definitions Energy audit Equipment/system review focused on identifying capital equipment upgrades.

Definitions Performance optimization Measurement & verification to ensure mechanical system performance matched to demand

Audit vs. Optimization Monitoring equipment uncovers unintended use: Typical daily 100 HP CHW pump ramping up at 12 a.m. in December

Audit vs. Optimization Optimization Recommendation Example: Eliminate unintended motor use Audit Recommendation Example: Replace high-use motor with more efficient model ~20% savings of motor use >75% savings of motor use + extended life

Healthcare Today Optimization Potential energy to be used Energy needed to meet performance requirements Understand the real building/system load

Optimization Summary Focus on verified performance Optimize system performance Strategic data measurement and analysis Focus on ROI (typically < 12 months) Optimum energy consumption is natural byproduct

Why Optimization Works Typical New Building Commissioning Project (200K SF) 150 200 components reviewed ~ 200 300 deviations discovered 50% fail functional testing

If your building is not commissioned Systems are under performing Operational problems exist Energy is being wasted

Underlying Principle Strategic measurements & analysis determines optimal equipment use. 10% - 15% inefficiency is hidden in assumptions.

Optimization Process Benchmark Building Parameters (Load) Type/Use/Occupancy Systems Control strategy Utility Data Collect and analyze performance data from key building systems Compare actual to intended performance Identify Energy Efficiency Measures with cost/savings analysis

Yale University: Energy Yale s power plants provide utility services to over 11 million square feet of facilities, which include research laboratories, academic buildings, administrative buildings, residential buildings, dining facilities and athletic facilities.

MTCO 2 e / year (x1000) Yale University: Building Efficiency Energy initiative summary for 90 pre-2005 buildings 25 20 15 Matching energy use to need Increase efficiency of building systems 10 5 Increase building envelope performance 0 1 2 3 4 Simple payback (years)

2009 Article: Before Adding, Try Reducing Efficiency improvements, these sources add, are often an easy, cheap fix in the struggle to reduce CO 2 emissions.

Taking the Initiative Optimizing building performance is fundamental to your business a) Why do most buildings subperform? b) Where do you start? c) How can you estimate your ROI?

Where Do You Start? Request & review data Account for specialty areas Benchmark building * Higher scores = Better efficiency * EH&E offers building benchmarking as a free service.

Next: Performance Profile Review Verify Document What systems? How are these systems operating? When are these systems operating?

Performance Profile 1. Review of Building Systems & Operating Strategy 2. Utility Data Analysis 3. Operating Data Acquisition 4. Data Analysis and Deviations List 5. Report & Savings Estimate

Review of Building Systems 1. Identify Building Systems & Operating Strategy Review & Document Building drawings & As-built documentation Control system sequence of operation Control points list Interview facility operations staff Goal Create an operational & performance benchmark

Utility Data Analysis Account # ID Location Sq.Ft. Peak Off Peak Total kwh kwh/ Sq.Ft. 2637-015- 1008 2637-034- 1005 Meter 1 Pods D,E 160,545 1,476,179 2,204,901 3,681,080 22.93 Meter 2 Pods A, B, C 183,455 2,369,602 4,204,358 6,573,960 35.83 Total 344,000 3,845,781 6,409,259 10,255,040 29.81

Utility Data Analysis Location Sq.Ft. Avg. kw Hrs/Year Total kwh / Sq.Ft. Data Center 4,200 138.8 8760 1,215,888 289.50 Mail Center 3,200 8.995 8760 78,796 24.62 Call Center* 7,500 70 8760 613,200 81.76 Gas Skada* 3,200 80 8760 700,800 219.00 Cafeteria 15,000 21.06 8760 184,486 12.30 Total 33,100 2,793,170 84.39

Electrical Demand Data Analysis

Operating Data Acquisition RTU-2, SAT 120 100 80 Temp. / RH 60 65 deg. 48 deg OA Temp (F) OA RH (%) Supply Temp (F) 40 20 0 3/9/04 0:00 3/10/04 0:00 3/11/04 0:00 3/12/04 0:00 3/13/04 0:00 3/14/04 0:00 3/15/04 0:00 3/16/04 0:00 3/17/04 0:00 3/18/04 0:00 3/19/04 0:00 3/20/04 0:00 Date

Operating Data Acquisition Typical daily 100 HP CHW pump ramping up in the middle of the night in December! 12:00 AM

Operating Data Acquisition BEFORE Modifications - Classroom Dew Points June 2006 OA Dew Point ( F) 101 Dew Point ( F) 102 Dew Point ( F) 103 Dew Point ( F) 104 Dew Point ( F) 75 70 Dew Point Temperature ( F) 65 60 55 50 45 Occupied Occupied Occupied Occupied 40 6/15/06 0:00 6/15/06 8:00 6/15/06 16:00 6/16/06 0:00 6/16/06 8:00 6/16/06 16:00 6/17/06 0:00 6/17/06 8:00 6/17/06 16:00 6/18/06 0:00 6/18/06 8:00 6/18/06 16:00 6/19/06 0:00 6/19/06 8:00 Date and Time

Operating Data Acquisition AFTER Modifications - Classroom Dew Points September 2007 OA Dew Point ( F) 101 Dew Point ( F) 102 Dew Point ( F) 103 Dew Point ( F) 105 Dew Point ( F) 75 70 Dew Point Temperature ( F) 65 60 55 50 Occupied Occupied Occupied 45 40 9/25/07 12:00 9/25/07 20:00 9/26/07 4:00 9/26/07 12:00 9/26/07 20:00 9/27/07 4:00 9/27/07 12:00 9/27/07 20:00 9/28/07 4:00 9/28/07 12:00 9/28/07 20:00 9/29/07 4:00 Date and Time

Night Setback Example ~15,000 cfm reduction @ $5.00 per cfm savings = $75K/yr.

Case Study: Hospital Acute care hospital with labs + medical office building 337,550 square feet Energy consumption: 9,818,200 kwh (main building) 1,456,200 kwh (medical office building) 453,638 Therms (central plant) Energy costs: ~$1,900,000 / year Target = 10% Total Energy Savings

What makes optimization rise to the top compared to other energy-saving measures?

Client testimonial Targets low cost No client capital investment High ROI Right thing to do

Annual Electrical Use

Peak/Off Peak Data Table 5.1 Case Study Hospital Consumption Month Peak kw Peak kwh Off-Peak kwh Total kwh % Off-Peak kwh Jan-10 1,260 281,400 417,200 698,600 60% Feb-10 1,092 278,600 417,200 695,800 60% Mar-10 1,064 261,800 445,200 707,000 63% Apr-10 1,372 287,000 396,200 683,200 58% May-10 1,456 313,600 420,000 733,600 57% Jun-10 1,792 330,400 460,600 791,000 58% Jul-10 1,778 369,600 609,000 978,600 62% Aug-10 1,834 431,200 623,000 1,054,200 59% Sep-10 1,876 415,800 623,000 1,038,800 60% Oct-10 1,820 357,000 539,000 896,000 60% Nov-10 1,806 287,000 434,000 721,000 60% Dec-10 1,484 315,000 505,400 820,400 62% Annual Totals 18,634 3,928,400 5,889,800 9,818,200 60% kw kwh kilowatt kilowatt Hour

24 Hour Demand Profile

Electrical Use / Equipment 15% 8% 22% 32% Split AC 100% OA Units Mixed air units Exhaust/return fans Pumps 23% kwh Breakdown of Equipment Monitored

Natural Gas Usage

Gas Usage Breakdown 2,604 Therms / month: Domestic hot water supply to patient rooms 4,800 Therms / month: Sterilizers 4,800 Therms / month: HVAC base load during this month? 10,101 Therms unaccounted for

Data Acquisition 6 rounds of 1 week data acquisition Air handling units Chilled water system Steam/hot water system Compressors Patient rooms Non-patient rooms

Space Use / Hours of Operation Patient rooms/direct patient support: ~30% Indirect patient support / office / other

Key Finding / Opportunities Building schedule Air handling unit schedule Exhaust fan schedule Fan coil unit setback Air handling unit (AHU, AC, RTU) discharge air temperature control and simultaneous heating and cooling Hot water pump sequencing Equipment maintenance

Steam Valve Leakage

Constant VFD Operation

Fan Coil Unit Maintenance

Estimated Savings

Updated Savings Equipment Recommended Change kwh Savings AC-4, 5,10, 12, 13/16,14,15, Moakley, Cancer Center, 30, 31 Air Handling Unit Steam Valves Set the air handling units on an occupancy schedule (Fan Savings) Set the air handling unit on an occupancy schedule (Heating/Cooling Savings) Fix steam leakby on air handling unit reheat valves. Savings assume 15% leakby on AC-6, 8, 9, 10, 12, 14, 15, 13/16, 18, 19, 20, 21, 30, 31 Annual Electric Savings($) Gas Unit Savings (Therms) Annual Gas Savings($) Total Annual Savings($) Cost to Fix ($) Simple Payback 506,251 $ 60,750 - $ - $ 60,750 $ 7,600 0.13 120,327 $ 14,439 124,969 $ 124,969 $ 139,408 $ 7,600 0.05 189,624 $ 22,755 40,598 $ 40,598 $ 63,353 $ 23,000 0.36 Hot Water Pumps 1,2,3 Fan Coil Units Adjust operating schedule to run fewer pumps during the cooling season (Pump Savings) Set approximately 40% of fan coil units on a temperature setback plan Total 816,202 97,944 165,567 165,567 $ 263,511 38,200 0.14 < 2 month payback

Additional Opportunities Patient room FCU improvements Economizer mode optimization Chilled water distribution control Compressor improvements Process equipment scheduling Optimized schedule for ORs, radiology, labs, etc.

Health Care Campus Dashboard Hospital One

Results Hospital One Total Savings Electric Savings Gas Savings Total Savings Total Energy KwH ($) therms ($) kbtu ($) Savings (%) Performance Year 614,992 $73,799 105,779 $97,316 12,675,229 $171,115 14% Maintenance Year 1 908,653 $109,038 112,796 $103,772 14,378,313 $212,810 16% Hospital One Maintenance Year 2 464,347 $55,721 33,739 $31,039 4,957,226 $86,761 13% Electric Savings Gas Savings Total Savings Total Energy KwH ($) therms ($) kbtu ($) Savings (%) Hospital Two 74,146,213 kbtu Performance Year 614,992 Electric Savings $73,799 105,779 Gas Savings $97,316 12,675,229 Total Savings $171,115 Total 14% Energy KwH ($) therms ($) kbtu ($) Savings (%) Maintenance Year 1 908,653 $109,038 112,796 $103,772 14,378,313 $212,810 16% Performance Year 493,900 $59,268 75,095 $69,087 9,193,699 $128,355 12% Maintenance Year 2 464,347 $55,721 33,739 $31,039 4,957,226 $86,761 13% $1,048,217 Hospital Three Gas Savings Electric Savings Total Savings KwH ($) therms ($) kbtu ($) Performance Year 972,757 $116,730 52,622 $48,412 8,579,301 $165,143 11% Hospital Four Total Energy Savings (%) Electric Savings Gas Savings Total Savings Total Energy KwH ($) therms ($) kbtu ($) Savings (%) Performance Year 675,849 $81,101 220,578 $202,931 24,362,445 $284,033 19%

Analysis To Insights

What have the results been from optimization across the organization?

Client testimonial Extraordinary Exceeded savings targets (14% vs. 10%) Total system wide savings should be ~ $2 Million Facility Staff buy-in

Summary Improving performance is high-roi Requires strategic monitoring and inspection Focus is on using existing equipment efficiently (as intended) Improvement is predictable (>10%)

Summary Improving building performance can significantly improve business performance. Lower energy costs Reduce complaints/maintenance tickets Reduce premature equipment failures Better (funded) capital improvement plans Lower occupancy costs Higher employee productivity Successful facilities managers!

Questions

For More Information Contact: Michael Della Barba mdellabarba@eheinc.com (800) 825-5343 www.eheinc.com Company Name Website Email Address