Drinking Water Disinfection A History and Improved Monitoring Techniques. Randy Turner Technical Director, Chemist Swan Analytical USA

Similar documents
Drinking Water Treatment Optimization Tools

The Control of Microorganisms LC D R B R I A N B E A R D E N, M S, P E

A Method to Determine Biodegradable Dissolved Organic Nitrogen in Water ND 58108, USA

Treatment Processes for Potable Water

Chloramine Optimization through Proper Mixing and a Unique Chloramine Management System. John Kiernan

Nitrification Action Plans (NAPs)

Drinking Water Treatment: Filtration and Disinfection

Granular Activated Carbon System

Control of Trihalomethanes (THM s) In Wastewater. Philip S. Bober, Operations Superintendent, Wayne Township

VILLAGE OF GREENWICH STATE OF OHIO Administration Offices: 45 Main Street. Greenwich, Ohio (419)

FOOD PRODUCTION WATER SUPPLIES

Benefits of On-line Monitoring of Carbon, Nitrogen and Phosphorus

Water Based Critical Utilities. RO, WFI, and Steam

Should we use a residual in our drinking water distribution systems?

Water Quality Changes in the Distribution System. Module 6

FIFTH GRADE WATER 1 WEEK LESSON PLANS AND ACTIVITIES

WATER QUALITY REPORT

Annual Drinking Water Quality Report 2016 Ripley Water Works 108 South Street Ripley, WV PWSID# January 30, 2017

City of Paso Robles Uses Online Monitor to Detect Low-Level of THMs in Treated Wastewater

THM Removal by Water Spray Aeration- Tank Top Results. Thomas F. Clark, P.E. Production Engineer Monroe County Water Authority Rochester, New York

COMBITECH. A. Forslund P. Fogh, E.J. Jurgensen, A. Dalsgaard, H.C. Bruun Hansen

The Formation and Control of Iodinated Trihalomethanes in Drinking Water Treatment

Annual. Water. Quality. Report. Proudly Presented By: City of Moscow Water Department PWS ID#:

COOLING TECHNOLOGY INSTITUTE

Physical and Chemical Control of Microorganisms

The Water We Drink. Why is drinking water important to you? How much drinking water do we have? Where We Find the Earth's Water

Comparison of Water Quality Parameters

REAL WORLD APPLICATIONS OF USING DYNAMIC SIMULATION SOFTWARE TO OPTIMIZE WATER TREATMENT PLANT PROCESS OPERATIONS

WATER. Annual QUALITY REPORT. Reporting Year Presented By City of Plantation PWS ID#: FL

Module 1: General Overview

Wastewater Treatment Processes

INTRODUCTION: WHERE DOES OUR WATER COME FROM?

Annual Drinking Water Quality Report 2015 MINERAL WELLS PSD 53 Fox Run Dr. Mineral Wells WV, PWS# WV June 13, 2016

Unit Treatment Processes in Water and Wastewater Engineering

Water Project Team. Sanitation Overview

Another question is, does EPA have the legal authority to regulate TOC. The Senator's letter addresses that matter.

the blue pages The Practice of Chlorination: Application, Efficacy, Problems and Alternatives the IWSA information source on drinking water issues

Dover Water Company (PWSID#: NJ ) 100 Princeton Avenue, Dover, NJ Year 2017 Annual Water Quality Report

Evaluation of Second-Stage Contactor Media for Manganese Removal

ADVANCED SOFTENING MATERIAL FOR PROBLEM WATER

Old City, New Ideas: Peracetic Acid in Wastewater Disinfection at St. Augustine

Technical Discussion Paper on Proposed Ontario Drinking Water Quality Standards

Basic Steps in DW Treatment Process. Water Treatment. EPA and DBP s. Scottsdale Chaparral DW Plant

ADVANCED SOFTENING MATERIAL. for problem water. SIMPLE SOLUTION FOR 5 PROBLEMS hardness iron manganese natural organic matter ammonium

10 things you need to know about monitoring Total Residual Oxidants

ANALYSIS OF THE IMPACT OF CITRIC ACID CIP CARRYOVER ON DISINFECTION BY-PRODUCT FORMATION IN MEMBRANE TREATMENT FACILITIES.

NCEA Level 1 Chemistry (90933) 2012 page 1 of 5. Q Evidence Achievement Achievement with Merit Achievement with Excellence NØ N1 N2 A3 A4 M5 M6 E7 E8

Conditions for Making Sodium Hypochlorite (Bleach) for Water Treatment in a Developing Country While Avoiding Inorganic Disinfection By-Products

THMs Control in Wastewater Treatment Plant Effluent Jurek Patoczka 1, Peter Tyrrell 2 and Michael Wynne 2

Introduction and Water Resources Source Water Assessment Additional Health Information

Protect MORE than just your drinking water. Purify water for your entire home.

Raw Water Activities

Water Pollution. Objective: Name, describe, and cite examples of the eight major types of water pollution.

Fairfax County Water Authority

Module 1 General Overview Volume I

Optimization of an Advanced Water Treatment Plant: Bromate Control and Biofiltration Improvement

City of Bellevue Water Department Drinking Water Consumer Confidence Report

Water for Instrument Processing

Why Standards Matter For Drinking Water Filters

Online Methodology for Determining THM Formation Potential & Predicted Network TTHM Levels

LT1ESWTR Disinfection Profiling and Benchmarking

CITY OF ST. LOUIS Water Quality Report 2016

2016 Water Quality Report to Consumers

MONITORING PLAN FOR THE DISINFECTANTS/DISINFECTION BYPRODUCTS RULES

ATTACHMENT A TO THE AGREEMENT FOR ENGINEERING SERVICES. Project: Chloramine Replacement Alternative Evaluation

City of River Rouge, MI

How can liquid ozone be used in different industries?

MAINTAINING DRIP IRRIGATION SYSTEMS

TermoRens Offshore Service as

How Clean is Your Tap Water? Abigail Laskowski

Haiti Project MAP. SODIS, Pete. THM s, Daniele. Best Practices, Farzana. Chlorine Generation, Nadine

Chapter 7: Control of Microbial Growth

Important Terminology

WATER QUALITY. Santa Margarita Water District

2016 Annual Drinking Water Quality Report

Este reporte incluye información importante sobre el agua para tomar. Para asistencia en español, favor de llamar al telefono

Ultraviolet Sterilization Technology

East Maui Watershed Partnership Adapted from Utah State University and University of Wisconsin Ground Water Project Ages 7 th -Adult

ANNUAL DRINKING WATER QUALITY REPORT FOR 2016

2010 ANNUAL WATER QUALITY REPORT CLAUDE H. DYAL WATER TREATMENT PLANT 351 SHEARER BLVD., COCOA, FL PWS ID#: FL

37 th Annual Food Safety & Sanitation Workshop Don Jones. Basic Cleaning. Basic Cleaning

Drinking Water: A Half Century of Progress

2017 Water Quality Report

Reverse-osmosis membranes were

Introduction to Drinking Water Systems. Indiana Basics Course for Small Public Drinking Water Systems -1

ENVIRONMENTAL AND HEALTH ASPECTS OF WATER TREATMENT AND SUPPLY Design of Water Treatment Facilities - Katsuyoshi Tomono, Yasumoto Magara

Important Terminology (pg )

Removal of Manganese by Microfiltration in a Water Treatment Plant*

Potential of Advanced Oxidation Processes (AOP) for Simultaneous Disinfection and Polishing of Drinking Water

Beer Line Disinfection System

2014 Water Quality Report

Water Quality Report Annual. Cambridge Water System PWS ID: NY

CITY OF KENT. Division of Water

2016 Annual Drinking Water Quality Report Beau Chêne Water System Public Water Supply ID: LA June 14, 2017

AD26 Systems for Iron, Manganese, Sulfide and Arsenic Removal

Integrating Ozone and Ion Exchange into a 40 Year Old Lime Softening Plant

IDEAL FOR DRINKING WATER, POOLS, SPAS, ENVIRONMENTAL, FOOD & BEVERAGE WATER QUALITY TESTING

City of Bruceville-Eddy Water Supply

JACKSON TOWNSHIP MUNICIPAL UTILITIES AUTHORITY

Boiling point in C. Colour in aqueous solution. Fluorine 188 colourless. Chlorine 35 pale green. Bromine X orange.

Transcription:

Drinking Water Disinfection A History and Improved Monitoring Techniques By Randy Turner Technical Director, Chemist Swan Analytical USA History In many countries we take for granted the availability and reliability of safe drinking water. A recent trip outside of the US reminded me of this fact when I saw notices in the hotel rooms stating the drinking water met specific standards and was safe to drink however, my friends from the country emphatically warned me to not drink the water. The relationship between clean drinking water and health has been known for centuries. Clear water was considered to be clean water and swamp water was associated with fever and disease. Disinfection has been applied for centuries, two basic rules dating back to 2000 B.C. state that water must be exposed to sunlight and filtered with charcoal and that impure water must be purified by boiling the water and then dipping a piece of copper in the water seven times, before filtering the water. Records of ancient civilizations boiling water and storing water in silver jugs were found. Water purification was performed with copper, silver, and electrolysis. Disinfection has been performed for several decades however, the mechanism has been known for only one hundred years. The microscope was developed in 1680 however it took scientists another two hundred years before they started using the microscope to distinguish microorganisms and other pathogens. In 1685 Italian physician Lu Antonio Porzo developed the first multiple filter. The filter consisted of a settling unit and a sand filtration unit. In 1746 the first patent for a filter design consisting of wool, sponges and charcoal, which was applied in households by 1750, was issued in France. Humans have suffered from water-borne diseases such as cholera, typhoid, and the plague. In 1854 a cholera epidemic caused many deaths in the city of London. An English doctor, John Snow, discovered that the cholera epidemic was caused by a contaminated water pump. He prevented the spread of the epidemic by closing down the contaminated water pump. After that scientists have performed bacteriological studies to research the development, existence, and identification of microorganisms and the removal of microorganisms from drinking water. In the nineteenth century the effect of disinfectants, such as chlorine, was discovered. Since 1900 disinfectants have been largely applied by drinking water companies to prevent water-borne diseases and to improve water quality and reduce the incidence rate of water-borne diseases as shown in figure 1.

Figure 1: The effect of chlorination in reducing deaths by typhoid fever. Disinfection of Drinking Water Disinfection of drinking water can be accomplished in a number of ways using various disinfectants or combinations thereof. The following is a list of disinfectants employed however chlorine is the most common disinfectant employed. 1. Chlorine a. Gaseous b. Sodium hypochlorite (liquid bleach) 2. Chlorine dioxide 3. Ozone (Typically followed by chlorination to ensure residual in the distribution system) 4. Monochloramine 5. UV (Typically followed by chlorination to ensure residual in the distribution system) 6. Hydrogen Peroxide (Typically followed by chlorination to ensure residual in the distribution system) Chemistry of Chlorine How does chlorine actually carry out disinfection? Chlorine is a strong oxidizer. Depending on ph, the reaction of HOCl and water further yields equilibrium between hypochlorous acid and hypochlorite ion as shown in figure 2. Hypochlorous acid (HOCl) is approx. 70-90 times stronger oxidant then the hypochlorite ion OCl - which is predominant at higher ph s. Efficiency of disinfection with free chlorine decreases significantly with an increase in ph value.

Figure 2: ph dependent equilibrium of chlorine The further dissociation, along with the two types of hypos (mainly hypochlorous acid which is electrically neutral), can penetrate the cell walls of the organism and displace molecules needed to survive. The organism can no longer function or replicate and eventually dies as shown in figures 3 and 4. Figure 3: Example of bacteria. Figure 4: Illustration of how HOCl penetrates cell wall due to neutral charge. Free chlorine is a powerful oxidant and reacts rapidly with organic and inorganic matter. As a result, the strong disinfectant residual it initially provides may not persist as long as necessary within the distribution system. Free chlorine can readily react with organics to form unwanted disinfection byproducts (DPBs) such as trihalomethanes (THMs) and haloacetic acids (HAAs).

Safe Drinking Water Act of 1974 The Safe Drinking Water Act (SDWA), enacted in 1974, is the main federal law that ensures the quality of Americans' drinking water. Under SDWA, EPA sets standards for drinking water quality and oversees the states, localities, and water suppliers who implement those standards. The law was amended in 1986 & 1996 requiring many actions to protect drinking water and its sources: rivers, lakes, reservoirs, springs, and ground water wells. Amendments to the SDWA in 1996 require EPA to develop rules to balance the risks between microbial pathogens and disinfection byproducts (DBPs). The Stage 1 Disinfectants and Disinfection Byproducts Rule and Interim Enhanced Surface Water Treatment Rule, promulgated in December 1998, were the first phase in a rulemaking strategy required by Congress as part of the 1996 Amendments to the Safe Drinking Water Act. The Stage 2 Disinfectants and Disinfection Byproducts Rule (Stage 2 DBPR) builds upon the Stage 1 DBPR to address higher risk public water systems. This final rule strengthens public health protection by tightening compliance monitoring requirements for two groups of DBPs, trihalomethanes (TTHM) and haloacetic acids (HAA5). Stage 2 DBPR requires systems to perform a system evaluation to identify the locations with high DBP s which become the systems compliance sampling points. This has led many municipalities to employ chloramination to minimize formation of THM and HAA. Figure 5 illustrates a profile of water containing few impurities to react with chlorine to for disinfection byproducts (DBP s) as well as water containing greater levels of impurities resulting in more DBP formation. Figure 5: Illustration of DBP s formed in clean and not so clean water. Chloramination results in lower concentrations of THM and HAA. Proper control of the chloramination process yields lower concentrations of DBP s thereby providing high quality drinking water for the public. Figure 6 illustrates the chloramination process and control of the process by monitoring the free, monochloramine, and total chlorine.

Figure 6: Chloramination process and monitoring of the process. Disinfectant Residual Monitoring Federal and state regulatory agencies regulate the monitoring of disinfectant residuals as well as the concentration of the disinfectant employed. Therefore if a system is using chlorine as their disinfectant they must maintain the required concentration of free chlorine and monitor the chlorine residual in accordance with EPA Method 334.0. Therefore the organization must monitor the free chlorine. Most systems use continuous monitoring either Amperometric or DPD based measurement systems. However monitoring the free, monochloramine, total chlorine, and combined chlorine provides the operator with much more information regarding the water quality. As seen in figure 5, clean water contains few impurities thereby DBP production is minimized. If greater levels of impurities are present higher concentrations of DBP s are produced. This can be readily observed if comprehensive chlorine monitoring is performed. This can be accomplished as follows: Free Residual Chlorine Red color formation with DPD and buffer Reaction time of 3 5 sec According ISO 7393-2 / EPA 334.0 Total Chlorine 1 TC1 (Sum of free chlorine and monochloramine) Additional Potassium Iodide (KI) is added to the buffer. Red color formation with DPD Reaction time of 3-5 sec Monochloramine calculated by subtracting free chlorine determined in previous step from Total Chlorine 1 Total Chlorine 2 TC2 (Sum of all chlorine species) Red color formation with DPD, buffer and KI Reaction time of 120 seconds! Combined (di- and tri-chloramines determined by subtracting TC1 from TC2

This allows the operator to be aware of when the water supply is experiencing contamination such as by farming whereby fertilizer run-off can increase the ammonia concentration in surface waters or ground waters under the influence. An example is shown in figure 7. Chloramination Figure 7: Example of seasonal influence on water quality. For systems employing chloramination and analyzer that can monitor free, monochloramine, total chlorine, and combined chlorine provides sufficient data and control capability to properly control the chloramination process. Most systems maintain 0.05 ppm of free chlorine to ensure free ammonia is not present to reduce the risk of nitrification. Also, the free residual must be maintained at a low level to avoid formation of di and tri-chloramines. Figure 8 illustrates a desirable profile for chloramination. The monochloramine concentration is slightly less than the total chlorine concentration indicating there is very little dichloramine formed. The presence of 0.05 ppm free chlorine ensures there is no free ammonia present which reduces the risk of nitrification. Ana analyzer that can provide this level of monitoring is ideal for monitoring and controlling chloramination. Figure 9 is data from a water system employing chloramination. As illustrated the monochloramine concentration is slightly less than the total chlorine concentration. The free chlorine is consistently very low ( 0.05 ppm) much of the time, however at one point the free chlorine concentration increased resulting in increased dichloramine formation and reduce monochloramine concentration. The operator took corrective action to bring the process under control. The ammonia feed system also failed resulting in reduced monochloramine and total chlorine concentration until ammonia feed was resumed.

Figure 8: Chloramination monitoring profile. Figure 9: Municipality chloramination process monitoring data. Summary Clean, safe drinking water is essential for public health. Man has been aware of this and practiced various forms of disinfection for centuries. In the 1900 s disinfection of drinking water with chlorine became the standard practice which has greatly reduced water-borne disease incident rates where properly practiced. As concerns about the health effects of disinfection by-products grow the regulatory agencies place more stringent limits on those species of concern thereby impacting treatment and disinfection processes. Monitoring not only the free chlorine but the monochloramine, total chlorine, and combined chlorine provides the operator with much more data regarding water quality and allows the

operator to refine his treatment and disinfection processes to improve water quality. It alerts him/her of changes is raw water quality which impacts finished product quality allowing them to take action and if necessary install new processes for treatment and/or disinfection to provide the best quality drinking water. The Swan AMI Codes II CC reliably monitors: Free chlorine Monochloramine Combined chlorine (di- and tri-chloramine) Total chlorine. The operator is informed about measurement validity. The integrity of the analyzer can be verified within minutes. Reagent level is continuously monitored. Process ph monitoring is optional. To see more information on the Swan AMI Codes II CC click on the link below: Swan AMI Codes II CC Datasheet Figure 10: Swan AMI Codes II CC