Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

Similar documents
ProSEC 300S. Protein Characterization columns

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

Choosing the Right Calibration for the Agilent Bio SEC-3 Column

R R Innovation Way P/N SECKIT-7830 Newark, DE 19711, USA Tel: Fax: Website: Published in November 2013

Lifetime stability of size exclusion chromatography columns for protein aggregate analysis

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS

Analysis of biomolecules by SEC and Ion-Exchange UPLC

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

A universal chromatography method for aggregate analysis of monoclonal antibodies

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides

Peptide Mapping: A Quality by Design (QbD) Approach

Analysis of Intact and C-terminal Digested IgG1 on an Agilent Bio MAb 5 µm Column

Protein-Pak Hi Res HIC Column and HIC Protein Standard

Physical Stability of a Silica- Based Size Exclusion Column for Antibody Analysis

Bio-Monolith Protein G Column - More Options for mab Titer Determination

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

Size-Exclusion Chromatography (SEC) Optimization Guide

HIC as a Complementary, Confirmatory Tool to SEC for the Analysis of mab Aggregates

mab Titer Analysis with the Agilent Bio-Monolith Protein A Column

Sepax Technologies, Inc.

Fraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction. chromatography. Agilent 1260 Infinity II Bio-Inert System

'Tips and Tricks' for Biopharmaceutical Characterization using SEC

Fast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover

Analysis and Purification of Polypeptides by Reversed-Phase HPLC

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

Agilent BioHPLC Columns PROTEIN IDENTIFICATION AND IMPURITY PROFILING USING REVERSED-PHASE HPLC/UHPLC

ACQUITY UPLC Protein BEH SEC Columns and Standards

Application Note. Author. Abstract. Biotherapeutics and Biologics. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany

Protein Quantitation using various Modes of High Performance Liquid Chromatography

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Method Translation in Liquid Chromatography

MAbPac SCX-10 Columns

Superdex 200 Increase columns

AZURA Bio LC. 2 FPLC and Purification Solutions

mabs and ADCs analysis by RP

Cell Clone Selection Using the Agilent Bio-Monolith Protein A Column and LC/MS

EASY-Spray Columns. Guidance for column set up and installation Tips to maximize column lifetime

Preparative HPLC is still the

Flexibility with. Preparative HPLC

A Fast and Robust Linear ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge Variant Analysis

Why filter your samples before analysis? Benefits of Using Chromfilter Syringe Filters Daily: Designed for your application:

Development of Ultra-fast ph-gradient Ion Exchange Chromatography for the Separation of Monoclonal Antibody Charge Variants

Promix TM. Enter a New Era in Biomolecule Analysis with. Columns. Unsurpassed Selectivity and Peak Capacity for Peptides and Proteins

Instructions for Capillary Electrophoresis Peptide Analysis Kit

Agilent 1220 Infinity II LC GET ON THE FAST TRACK TO HIGHEST EFFICIENCY AT A PRICE YOU CAN AFFORD

Application Note. Author. Abstract. Small Molecule Pharmaceuticals. Sonja Krieger Agilent Technologies, Inc. Waldbronn, Germany

High Resolution Analysis of Heparin and Heparin-like Impurities on Glycomix TM an Anion Exchange Column

BÜCHI Labortechnik AG

Fundamentals and Techniques of Preparative HPLC. Parto Zist Behboud Tel: 42108

A comparison of automated and manual buffer exchange methods

3. Close the bottom end of the column and apply the packing device on top. Pump water through the upper adaptor to remove air.

An effective platform for purification of IgM monoclonal antibodies using Hydroxyapatite

Thermo Scientific Peptide Mapping Workflows. Upgrade Your Maps. Fast, confident and more reliable peptide mapping.

Size Exclusion Chromatography

Econo-Pac High Capacity Ion Exchange Cartridges, 5 ml Instruction Manual. Catalog Numbers , ,

Improving Resolution and Column Loading Systematically in Preparative Liquid Chromatography for Isolating a Minor Component from Peppermint Extract

Improved Peptide Maps Using Core-Shell Media: Explaining Better Biopharmaceutical Applications With Kinetex C18 Columns

Protein stability assessment after automated buffer exchange

Accucore. Ultimate Core Performance LC Column Technology to Maximize Your Investment. Dave Jarzinski. October 2011

Thermo Scientific LC Columns for Biomolecules

Optimization of cief to Resolve Challenging MAb Samples of Clinical Immunodiagnostic Relevance

Method Development Considerations for Reversed-Phase Protein Separations

Peptide Mapping of Glycoprotein Erythropoietin by HILIC LC/MS and RP-LC/MS

Preparative, Pilot & Process Columns

1. Connect the column to the chromatography system, syringe or pump.

ZORBAX StableBond HPLC Columns

New Core-Shell Technology

IgG Purity/Heterogeneity and SDS-MW Assays with High- Speed Separation Method and High Throughput Tray Setup

Capillary Electrophoresis of Proteins

Ultrahydrogel Columns

Zwitterion Chromatography ZIC

INTERNATIONAL PHARMACOPOEIA MONOGRAPH ON ARTEMETHER AND LUMEFANTRINE CAPSULES REVISED DRAFT FOR DISCUSSION

Bivalirudin Purification:

Thermo Scientific Technical Resources Document 1.5. LC Columns and Accessories. for Biomolecules

Molecules are separated by size. Small molecules enter pores of stationary phase (b), large molecules do not (a) Larger molecules elute first

Combining High Temperature and Small Particles: The Advantages of Zirconia

The Theory of HPLC Gradient HPLC

Size exclusion chromatography (SEC) with superficially porous (core-shell) particles

SCION GC Series. The Gas Chromatographers Choice for Separations

Using the Sartobind pico

Vectors for Gene Cloning: Plasmids and Bacteriophages

Next Generation Zirconia-Based Antibody Purification Media

Agilent MetaCarb Ca PLUS Carbohydrate Column Ca ++ Form User Manual Part No. A5205

Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns

Thermo Scientific BioLC Columns. Monoclonal antibody. characterization

ACQUITY UPLC H-Class Bio System

A Modular Preparative HPLC System for the Isolation of Puerarin from Kudzu Root Extracts

Technical Overview. Authors. Abstract. Verified for Agilent 1260 Infinity II LC Bio-inert System

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

C196-E067A. Prominence UFLCXR. Shimadzu Ultra Fast Liquid Chromatograph

Userguide: SepFast Gel Filtration columns

HPLC to UPLC Method Migration: An Overview of Key Considerations and Available Tools

Characterize Fab and Fc Fragments by Cation-Exchange Chromatography

An Automated System for At-Line Process Analysis of Biopharmaceutical Fermentation Reactions

Transcription:

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility Technical Overview Introduction Agilent AdvanceBio SEC columns are a new family of size exclusion chromatography (SEC) columns packed with.7 µm particles of a unique, low binding, polymer coated silica stationary phase. This technology provides imal nonspecific interactions, and gives improved peak shape for the analysis of biotherapeutic molecules such as monoclonal antibodies (mabs) and antibody drug conjugates (ADCs). While it is recommended to use an Agilent 16 Infinity Bio-Inert LC System with AdvanceBio SEC columns, the highly uniform.7 µm particles provide excellent column efficiency providing maximum protein recovery with operating pressures that allow operation on any HPLC system. This includes 4 bar legacy instruments through to 1, bar UHPLC instrumentation. AdvanceBio SEC 3Å has been designed specifically for monoclonal antibody aggregate analysis providing optimum performance where it matters, monomer and dimer resolution. AdvanceBio SEC 13Å has a similar high pore volume but covers smaller proteins and polypeptides. The wide selection of column dimensions covers all application needs: conventional 7.8 mm id to 4.6 mm id for higher sensitivity or where sample availability is restricted. Column lengths are 3 cm for traditional high-resolution separations, and 15 cm for higher speed where increased sample throughput is required. Five-centimeter guard columns are also available.

Instrument type Agilent 11 HPLC instrument, (4 bar) Agilent 16 Infinity Quaternary Bio-inert (6 bar) Agilent 19 Infinity Binary LC (1, bar) Example chromatogram Norm. 1 15 1 1 5 Norm. 1 15 1 1 5 Norm. 1 15 1 1 5 4 6 8 1 1 14 4 6 8 1 1 14 4 6 8 1 1 14 Figure 1. Illustrative examples of protein separations using different HPLC instruments (blue trace: BioRad protein standard mixture; red trace: γ-globulin). Note: These were different batches of proteins used in different laboratories. Conditions Parameter Value Eluent 15 mm Sodium phosphate buffer, ph 7. Flow rate Temperature Sample Instrument Wavelength 1. ml/ (7.8-mm columns) or.35 ml/ (4.6-mm columns) Ambient 1 mg/ml protein concentration Agilent 11 HPLC instrument (legacy, 4 bar) Agilent 16 Infinity Quaternary Bio-inert (6 bar) Agilent 19 Infinity Binary LC with G1315D DAD and Bio-inert flow cell (1, bar) nm

Choosing the Right Column Diameter Operating columns of different internal diameters requires adjustments in flow rate (to maintain the same linear velocity) and sample volume. The normal operating flow rate for 7.8 mm columns is 1. ml/, therefore, the correct flow rate to use for 4.6 mm columns is.35 ml/. The injection volume should be reduced by a similar amount to obtain comparable detector response, therefore, a 6 µl injection on a 7.8 mm column is reduced to µl for a 4.6 mm column. There may be slight differences in retention time observed due to extra-column volume in the instrument. Similarly, the observed backpressure from an instrument operated at 1. ml/ will be somewhat higher than the backpressure observed if the same instrument is operated at.35 ml/, particularly where low dead volume capillaries have been used. Figure shows the same batch of stationary phase packed into 3-cm columns in 7.8 mm and 4.6 mm dimensions, and tested on the same Agilent 16 Infinity Quaternary Bio-inert instrument. This clearly illustrates how similar in performance the columns are. The ability to use smaller injection volumes for 4.6 mm columns is ideal when sample availability is limited, and is better suited to modern low dead volume instrumentation. For applications requiring the use of less sensitive 1 15 1 1 5 1 15 1 1 5 A Agilent AdvanceBio SEC 3Å 7.8 3 mm 1. ml/ 1 3 4 5 detectors, including light scattering detectors, refractive index detectors, or longer UV detector wavelengths (when using mobile phase eluents that have a high background at lower wavelengths for example), the 7.8 mm column offers the capability to inject much larger sample volumes. 6 4 6 8 1 1 14 7 1. Thyroglobulin aggregates. Thyroglobulin monomer 3. γ-globulin dimer 4. γ-globulin monomer 5. Ovalbu dimer 6. Ovalbu 7. Myoglobin 8. Vita B1 4 6 8 1 1 14 B Agilent AdvanceBio SEC 3Å 4.6 3 mm.35 ml/ 8 Figure. Comparison of protein standard separation on 7.8 mm and 4.6 mm columns. 3

The strong buffer compositions used for analysis means there is a risk of precipitation or corrosion (if chloride ions are present in the mobile phase). There is also the possibility of bacterial growth in aqueous buffers that do not contain preservative. Regular preventative maintenance and always flushing instruments so that they are not left stored in buffer is essential. Freshly prepared buffer that has been filtered through a. µm membrane filter is a prerequisite for dependable operation. For these reasons, the instrument of choice is the Agilent 16 Infinity Quaternary Bio-inert system. Ensuring Ongoing Reliability Monitoring column performance is an important part of robust size exclusion chromatography. Phosphate buffers are known to cause deterioration of silica based stationary phases. AdvanceBio SEC columns have a proprietary hydrophilic polymeric layer to help imize nonspecific interactions. They are routinely tested to demonstrate robust column lifetime even in concentrated sodium phosphate buffers (Figures 3 and 4). Column lifetime may be diished if operated at higher temperatures or faster flow rates. Monomer area % 7 6 5 4 3 1 1 95 9 85 8 7 65 Injection Rs 1.16 (after days) 4.16 (after 4 days) 8. (after 8 days) 1,.19 (after 1 days) Figure 3. Lifetime experiment on an Agilent AdvanceBio SEC 3Å 7.8 3 mm column carried out with 1, injections during 1 days operation. Sample changed Injection 1 4 6 8 1 1 14 16 Monomer % Aggs % Dimer % Injection 1, Injection 8 Injection 4 3 15 1 5 Aggs and dimer area % 6 4 6 8 1, 1, Injection number Figure 4. Minimal change in monomer/dimer area% during lifetime experiment on an Agilent AdvanceBio SEC 3Å 7.8 3 mm column during 1 days operation. 4

Ensuring consistent results from instrument to instrument and laboratory to laboratory is essential for effective method transfer. Only by regularly using a protein standard mixture is it possible to detere if factors other than the column need to be optimized. Figure 5 shows the excellent reproducibility shown from closely matched instruments that are operating correctly. Agilent 13A AdvanceBio SEC protein standards A protein mix consisting of five carefully selected proteins (Ovalbu, Myoglobin, Aprotinin, Neurotensin, and Angiotensin II) designed to calibrate Agilent s 13Å AdvanceBio size exclusion columns. This standard can be used regularly to calibrate the column and ensure ideal system performance in various applications involving protein purification and analysis. Agilent 3A AdvanceBio SEC protein standards A protein mix consisting of five carefully selected proteins (Thyroglobulin, γ-globulin, Ovalbu, Myoglobin, and Angiotensin II) designed to calibrate Agilent s 3Å AdvanceBio size exclusion columns. This standard can be used regularly to calibrate the column and ensure ideal system performance in various applications involving protein purification and analysis. Response 4 6 7 A 1 Agilent 11 Series HPLC 15 8 1 1 1 5 3 5 4 6 8 1 1 14 1 15 1 1 5 B Agilent 16 Infinity Quaternary Bio 4 6 8 1 1 14 Figure 5. Comparison of a Protein Standard Mixture run on Agilent AdvanceBio SEC 3Å 7.8 3 mm columns using an Agilent 11 Series HPLC instrument and an Agilent 16 Infinity Quaternary Bio-inert instrument. Agilent AdvanceBio SEC protein standards Description Size Part no. 13Å 1.5 ml vial 519-9416 3Å 1.5 ml vial 519-9417 5

With an isocratic separation mechanism, the most likely explanations for differences in retention time are either flow rate inaccuracy (perhaps resulting from poor pump maintenance or general wear and tear), or differences in extra column dead volume (changes in capillary length or diameter, or sample loop size). This is particularly important when transferring methods to LC instruments from other vendors (Figures 6 and 7). AU.3...15.1.5 AU.5.4.3..1 A B 1 1 3 4 5 6 Agilent AdvanceBio SEC 3Å 4.6 15 mm on Waters H-Class System (.35 ml/) No. Time Area% 1.84 1. 3.3 87.8 Agilent AdvanceBio SEC 3Å 7.8 3 mm on Waters Alliance System (1. ml/) No. Time Area% 1 6.39 1.5 7.63 87.5 4 6 8 1 1 14 Figure 6. Comparison of γ-globulin separation using different column dimensions and different instruments. AU.7 3.6.5 1. Aggregates. Dimer 3. Monomer (Area% = 86.6 %) 4. Low MW fragment 5. Preservative.4.3..1 5 1 4 4 6 8 1 1 14 Figure 7. Four replicate injections of γ-globulin on a Waters Alliance HPLC system. 6

Control of Temperature A factor often overlooked when detering method robustness is the separation temperature. Very often separations are performed at ambient temperature; however, the normal temperature in a particular environment may depend on time of day and seasonal variations as well as the influence of heating or air conditioning. With aqueous separations, backpressure will vary noticeably with changing temperature, however some proteins are also affected. An improvement in resolution may be expected with increasing temperature; however, there may also be a change in the level of aggregation too (Figures 8 and 9). For this reason, it is highly recommended that separations are performed with the column contained in a thermostatically-controlled oven, and that the samples are maintained in a temperature-controlled environment. Conclusions Agilent AdvanceBio SEC columns have been developed to provide optimum performance regardless of the instrument used. This Technical Overview highlights some of the areas that need consideration to obtain comparable results on older 4 bar instruments through to modern UHPLC-capable instrumentation regardless of location or operator. 1 15 1 1 5 4. 4.5 5. 5.5 6. 6.5 7. 7.5 8. 8.5 Figure 8. Effect of analysis temperature of γ-globulin. Monomer area % 85 83 81 79 77 73 71 69 67 65 15 C 167.5 bar Rs 1.8 Monomer area% = 74.8 % C 14.6 bar Rs 1.8 Monomer area% = 73.9 % Monomer% Aggs% Dimer% 15 C C C 3 C 35 C 4 C 45 C 5 C 55 C Injection number Figure 9. Effect of analysis temperature of on monomer/dimer/aggregate content of γ-globulin. 18 16 14 1 1 8 6 4 Aggs and dimer area % 7

www.agilent.com/chem For Research Use Only. Not for use in diagnostic procedures. This information is subject to change without notice. Agilent Technologies, Inc., 16, 17 Published in the USA, November, 17 5991-63EN