International Code Council

Similar documents
2012 IBC Assembly Means of Egress. Based on the 2012 International Building Code

PRESCRIPTIVE COMPLIANCE METHOD

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

PRESCRIPTIVE COMPLIANCE METHOD

STAIRWAYS, HANDRAILS, AND GUARDRAILS (RESIDENTIAL)

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

ICC CODE CORNER 2012 IFC Code & Commentary

SECTION ALUMINUM BLEACHER SYSTEM (NEW SCHOOLS/REPLACEMENT AT EXISTING SCHOOLS)

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

Section 1 OBC FADS /13 Access to Parking Areas

Chapter 4-16 SPECIAL DESIGN STANDARDS FOR TYPE V CONSTRUCTION

2009 IBC Section 1024 Approved Luminous Egress Path Markings

4188 East Andrew Johnson Highway Morristown, TN

Comparison of the life safety elements of the 1997 UBC and the IBC 2000.

BRADYGLO EMERGENCY EGRESS MARKING HANDBOOK

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

Access Ladders And Disappearing Stairways: Code Compliant Solutions

Accessible Means Of Egress

Florida Accessibility Code for Building Construction

2007 Title 24 Accessibility Code Updates and ADA Issues

Applying the Building Code During Design

Q. Do residential and historical buildings that are going to be protected with sprinklers need to conduct an LSE?

From the ADA and ABA Accessibility Guidelines for Buildings and Facilities

High Piled Combustible Storage Guideline

PIP STF05511 Fixed Industrial Stairs

UNIVERSITY OF ARIZONA CONSTRUCTION AND RENOVATION PERMITTING PROCEDURE ADOPTED: JULY 2011

HERMIT S REST GRAND CANYON NATIONAL PARK BUILDING CODE REVIEW

Accessibility for Ontarians with Disabilities Act (AODA), 2005

City of Tacoma Planning and Development Services

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104

Priority 2 Access to Goods & Services

780 CMR CHAPTER 34 EXISTING BUILDINGS STRUCTURES

Building Code 8 th Edition

Chapter 1: Application and Administration

RESIDENTIAL BUILDING REQUIREMENTS

Mobile Homes/Manufactured Homes

Excerpts from: International Residential Code 2009

ARTICLE VII - OFF-STREET PARKING AND LOADING Section 7-10

PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED

Code Requirement for Solar Photovoltaic (PV) Systems - General

Introduction. Products conforming with a European Council Directive. CE marked construction products. Other regulations

Individual Truss Marking Is it a Building Code Requirement?

CITY OF BRISTOL DECK CONSTRUCTION GUIDE ACCORDING TO THE 2012 IRC WITH THE 2016 CT AMMENDMENTS

Uniform Building Code For Head-of-Wall, Vertical Shaft Walls and Wall Backing Excerpts from the 1997 Uniform Building Code

Visual Interpretation Of The

June 7, 2012 PARTIES INTERESTED IN HVAC DUCT ENCLOSURE ASSEMBLIES

Effective Date: 14-March Table of Contents

2003 International Residential Building Code

WON-DOOR CORPORATION Won-Door FireGuard Applications

Rationale Behind the Provisions of ASTM F 2200 & Illustration Guidelines Based on the Provisions of ASTM F 2200

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

Joint Evaluation Report ICC-ES (800) (562)

2010 ADA Standard Access to Performance Areas

Neighborhood Suburban Single-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

The Building Codes A.R.E. Building Design and Construction Exam Prep

BUILDING CODE COMMISSION

Copyright Materials. Presented by: The Wagner Companies R & B Wagner, Inc. The myth of the Ladder Effect and other railing safety issues

Manual for design of Guardrails

EB15-13 RB EB (NEW), (NEW)

Short title. This chapter may be cited as the "Kern County Building Code."

FACT SHEET #2 DECK INFORMATION

Safety barrier to a deck located adjacent to a retaining wall at Oraka Beach Road, Mahia

CALIFORNIA BUILDING CODE

Following are the NMHC/NAA Recommendations for the ICC Online Consensus Voting which opens on February 8 th, 2016:

Scaffolding Procedures

2015 IBC Chapters 1 and 35

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

SIDEWALK & RAILING REPLACEMENT BOARD OF ED BUILDING

What is a Won-Door FireGuard Door?

ATI Evaluation Service A Division of Architectural Testing Certification Services

Minnesota Healthcare Engineers Association, Fall Conference. Bob Dehler, P.E. Engineering Program Manager September 14, 2017

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)

ACCESSIBILITY CHECKLIST

CONSTRUCTION TECHNOLOGY UPDATE

Brown Bag Series 2015 #6

PIP STF05520 Details for Pipe Railing for Walking and Working Surfaces

Approval Standard. for. Flammable and Combustible Liquid Storage Buildings

Live Load Considerations for Truss Bottom Chords

Administrative Changes

TENTS AND MEMBRANE STRUCTURES

Chapter UNIFORM CODES FOR CONSTRUCTION BUILDING CODE

Excavation Safety Program

TENTS AND OTHER MEMBRANE STRUCTURES

11.1.2* Adjacent Hazards or Design Methods. For buildings with two or more adjacent hazards or design methods, the following shall apply:

CITY OF CHICAGO DEPARTMENT OF BUILDINGS

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

2. Does not require, involve or include any additions to, or repair or modification of, the existing foundation.

Structural Engineering

February 1, SUBJECT: Proposed Revisions to the Acceptance Criteria for Staples, Subject AC R1 (EL/JF)

Walking-Working Surfaces

CITY OF ST. PETERSBURG PLANNING & ECONOMIC DEVELOPMENT DEPT

Snow load design using the 2003 International Building Code

AKF Group LLC. A. Vernon Woodworth FAIA

2012 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

2012 IRC Sections R303 R310 Building Planning II

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

SJI Updates Expanded Load Tables for Noncomposite Joists / Joist Girders and Development of New Composite Joist Series

STRUCTURAL DESIGN CHAPTER 16

Transcription:

Page 1 of 21 International Code Council ICC 300-2012 edition Committee Actions Report For Committee Actions taken at the November 24 th and December 14 th, 2010 meetings

Page 2 of 21 IS-BLE1-10/11 ICC 300 Section 202 (New term) Proponent: Greg Nelson, BR Bleachers, Co. Add new text as follows: SECTION 202 DEFINED TERMS QUALIFIED PERSON: A professional trained in the proper and safe use, operation and repair of bleachers, folding and telescopic seating and grandstands and is knowledgeable in the requirements of this standard. Reason: Gives understandable meaning to the Qualified Persons description in 501.2 Inspections Committee Action: Approved as Submitted Committee Reason: The definition will clarify who is qualified to perform inspections. This is consistent with INC Chapter 27 when inspections are required. IS-BLE 2-10/11 ICC 300 Table 303.2 Proponent: Greg Nelson, BR Bleachers, Co. Revise as follows: TABLE 303.2 DESIGN LOADS TIERED SEATING ELEMENT Seats (vertical) Horizontal sway loads Treads 120 pounds per linear foot. LOAD 24 pounds per linear foot parallel to the seats and 10 pounds per linear foot perpendicular to the seats. These loads need not be assumed to act concurrently and need not be applied simultaneously with other lateral forces such as wind or seismic loads. Stair treads and aisle stair treads shall be designed to resist a minimum concentrated load of 300 pounds on an area of 4 square inches.

Page 3 of 21 Handrails and guards, uniform load Handrails and guards, concentrated load Guards, infill components Handrail assemblies and guards shall be designed to resist a load of 50 pounds per linear foot (pound per foot) applied in any direction at the top. The supporting elements shall transfer this load to the structure. Handrail assemblies and guards shall be able to resist a single concentrated load of 200 pounds, applied in any direction at any point along the top. Attachment devices and supporting elements shall transfer this load to the structure. This load need not be assumed to act concurrently with the uniform load. Intermediate rails (all those except the handrail), balusters, and panel fillers (including flexible infill components) shall be designed to withstand a horizontally applied normal load of 50 pounds on an area equal to 1 square foot, including openings and space between rails. Reactions due to this loading are not required to be superimposed with the uniform loads or concentrated loads. Application of the loads shall not allow guard openings greater than that permitted by Sections 408.2 and 503.2. For SI: 1 square inch = 645.46 mm 2, 1 square foot = 0.0929 m 2, 1 pound = 4.448 N, 1 pound per linear foot = 14.594 N/m. Reason: This expanded description addresses numerous instances in which flexible components have been used to close gaps over 4. They open up under loads, such as a small child leaning against a fence. Chain link fence installations that cover the entire row end but do not have supporting rail rungs attached at the bottom push out. Children can fall through or becoming trapped. Similar conditions in which cables or small infill rungs are used can also flex out under pressure and entrap heads or limbs. Committee Action: Approved as Submitted Committee Reason: The added language clarified what openings are acceptable when flexible guard components are used. IS-BLE3-10/11 ICC 300 Section 303.2, 303.4 Proponent: Daniel Victor, Interkal, LLC 1. Revise as follows: 303.2 Live Loads. Bleachers, folding and telescopic seating, and grandstands shall be designed for a uniform live load of 100 psf (4788 Pa). Press boxes shall be designed for a uniform live load of 50 psf (2394 Pa). The components of the installation shall be designed to support the loads listed in Table 303.2. TABLE 303.2 DESIGN LOADS

Page 4 of 21 TIERED SEATING ELEMENT Seats (vertical) Horizontal sway loads Treads Handrails and guards, uniform load Handrails and guards, concentrated load Guards, infill components 120 pounds per linear foot. LOAD 24 pounds per linear foot parallel to the seats and 10 pounds per linear foot perpendicular to the seats. These loads need not be assumed to act concurrently and need not be applied simultaneously with other lateral forces such as wind or seismic loads. Stair treads and aisle stair treads shall be designed to resist a minimum concentrated load of 300 pounds on an area of 4 square inches. Handrail assemblies and guards shall be designed to resist a load of 50 pounds per linear foot (pound per foot) applied in any direction at the top. The supporting elements shall transfer this load to the structure. Handrail assemblies and guards shall be able to resist a single concentrated load of 200 pounds, applied in any direction at any point along the top. Attachment devices and supporting elements shall transfer this load to the structure. This load need not be assumed to act concurrently with the uniform load. Intermediate rails (all those except the handrail), balusters, and panel fillers shall be designed to withstand a horizontally applied normal load of 50 pounds on an area equal to 1 square foot, including openings and space between rails. Reactions due to this loading are not required to be superimposed with the uniform loads or concentrated loads. For SI: 1 square inch = 645.46 mm 2, 1 square foot = 0.0929 m 2, 1 pound = 4.448 N, 1 pound per linear foot = 14.594 N/m. 2. Delete and replace as follows: 303.4 Stress increases. Where Handrails and guards are designed in accordance with the provisions for allowable stress design (working stress design) exclusively for the loads specified in Section 303.2, allowable stress for the members and their attachments is permitted to be in creased by one-third. Stresses permitted in the design standards of the various materials shall be permitted to be in creased by one-third due to sway or wind loads or by a combination of sway or wind loads and vertical loads, provided that no such increases shall be allowed for stresses due to vertical loads alone. All other allowable stress increases relative to the design of the installation shall be in accordance with the building code.

Page 5 of 21 303.4 Horizontal Sway Loads. Bleachers, folding and telescopic seating and grandstands shall be designed to resist lateral forces produced by the sudden and concerted motion of spectators. 303.4.1 Sway Parallel to Seating. A horizontal load of 24 pounds per linear foot shall be applied parallel to seating at the footboard level of each row of seating. 303.4.2 Sway Perpendicular to Seating. A horizontal load of 10 pounds per linear foot shall be applied perpendicular to seating at the footboard level of each row of seating. 303.4.3 Load Cases including Horizontal Sway Loads. In addition to the load cases required to be considered for design in accordance with the building code, the additional load case in Section 303.4.4 or in Section 303.4.5 shall be considered. Parallel and perpendicular sway loads need not be considered simultaneously. 303.4.4 Load combination using strength design or load and resistance factor design. When using strength design or load and resistance factor the following additional load combination must be considered. 1.2D+1.0L+1.6Z (Equation 3-1) 303.4.5 Load combination using allowable stress design. When using allowable stress design the following additional load combination must be considered. D+0.75L+0.75Z (Equation 3-2) 303.4.6 Notations of terms in load case equations. The following notations shall, for the purpose of this chapter, have the meanings shown herein. D = dead load as defined by the building code L = live load as defined by Section 303.2 Z = horizontal sway loads as defined by Section 303.4.2 and Section 303.4.3 Reason: The proposed removes the stress increase provisions for handrail and guard design to match changes in the 2009 IBC where section 1607.7.1.3 of the 2006 IBC was deleted. The proposed defines sway loading more completely and provides load cases for both LRFD and ASD design methods. Traditionally sway loading was handled similar to wind and earthquake loading. Older codes generally provided for the ASD method only and allowed a 1/3 stress increase for all materials in all load combinations which included wind or earthquake loads. The proposed additional load cases represent 2009 IBC equations 16-4 and 16-13 with W being replaced by Z. Per the referenced document, Stadium and Grandstand Design AISC 1947, higher lateral forces were reported with fewer men on the test apparatus. Therefore, large dense crowds are not capable of producing full design lateral forces. The load combinations chosen reflect this fact and align well with older 1/3 stress increase philosophies. Because the live load must be present to produce the lateral sway loads, other IBC load combinations which do include wind without the inclusion of live load such as equations 16-6 and 16-14 have not been included in this proposal.

Page 6 of 21 Staff note: Code change S14-06/07 deleted Section 1607.7.1.3 because it was addressed in the unified ASD/LRFD material standard. The deleted section in IBC was 1607.7.1.3 Stress increase. Where handrails and guards are designed in accordance with the provisions for allowable stress design (working stress design) exclusively for the loads specified in Section 1607.7.1, the allowable stress for the members and their attachments are permitted to be increased by one-third. Code change S84-09/10 has revised the load factors for wind from 1.6 to 1.0. See the attached information for the relative portions of the code change and reason. Committee Action: Approve as Modified Replace proposal with the following: 1) Revise Table 303.2 as follows: TABLE 303.2 DESIGN LOADS TIERED SEATING ELEMENT LOAD TYPE LOAD Seats (vertical) L 120 pounds per linear foot. Horizontal sway loads 24 pounds per linear foot parallel to seats and 10 pounds per linear foot perpendicular to seats. These loads need not be assumed to act concurrently and need not be applied simultaneously with other lateral forces such as wind and seismic. Treads L Stair treads and aisle stair treads shall be designed to resist a minimum concentrated load of 300 pounds on an area of 4 square inches. Handrails and guards, uniform load Handrails and guards, concentrated load Guards, infill components R r R r R r Handrail assemblies and guards shall be designed to resist a load of 50 pounds per linear foot (pounds per foot) applied in any direction at the top. The supporting elements shall transfer this load to the structure. Handrail assemblies and guards shall be able to resist a single concentrated load of 200 pounds, applied in any direction at any point along the top. Attachment devices and supporting elements shall transfer this load to the structure. This load need not be assumed to act concurrently with the uniform load. Intermediate rails (all those except the handrail), balusters and panel fillers shall be designed to withstand a horizontally applied normal load of 50 pounds on an area equal to 1 square foot,

Page 7 of 21 including openings and space between rails. Reactions due to this loading are not required to be superimposed with the uniform loads or concentrated loads. 2) Delete and replace as follows: 303.4 Stress increases. Where Handrails and guards are designed in accordance with the provisions for allowable stress design (working stress design) exclusively for the loads specified in Section 303.2, allowable stress for the members and their attachments is permitted to be in creased by one-third. Stresses permitted in the design standards of the various materials shall be permitted to be in creased by one-third due to sway or wind loads or by a combination of sway or wind loads and vertical loads, provided that no such increases shall be allowed for stresses due to vertical loads alone. All other allowable stress increases relative to the design of the installation shall be in accordance with the building code. 303.4 Horizontal Sway Loads. Bleachers, folding and telescopic seating and grandstands shall be designed to resist lateral forces produced by the sudden and concerted motion of spectators. 303.4.1 Sway Parallel to Seating. A horizontal load of 24 pounds per linear foot shall be applied parallel to seating at the footboard level of each row of seating. 303.4.2 Sway Perpendicular to Seating. A horizontal load of 10 pounds per linear foot shall be applied perpendicular to seating at the footboard level of each row of seating. 303.5 Load Combinations. In addition to the load combinations required to be considered for design in accordance with the building code, the additional load combinations in Section 303.5.1 or in Section 303.5.2 shall be considered. Parallel and perpendicular sway loads need not be considered simultaneously. Also uniform, concentrated and infill loads need not be considered simultaneously. 303.5.1 Load combinations using strength design or load and resistance factor design. When using strength design or load and resistance factor the following additional load combination must be considered. 1.2D+1.0L+1.6Z (Equation 3-1) 1.2D+1.2 R r (Equation 3-2) 303.5.2 Load combinations using allowable stress design. When using allowable stress design the following additional load combination must be considered. D+0.75L+0.75Z (Equation 3-3) D+0.75R r (Equation 3-4)

Page 8 of 21 303.5.3 Notations of terms in load combination equations. The following notations shall, for the purpose of this chapter, have the meanings shown herein. D = dead load as defined by the building code L = live load as defined by Section 303.2 Z = horizontal sway loads as defined by Section 303.4.2 and Section 303.4.3 R r = guard or handrail loads as defined in Table 303.2 (Renumber subsequent sections) Committee Reason: The modification addresses the stress increase concerns for guards and handrails brought up during the 11/24/2010 teleconference. The proposal addresses the coordination with sway changes in ASCE 7. IS-BLE 4-10/11 ICC 300 Section 309.1 Proponent: Gene Boecker, Code Consultants, Inc. Revise as follows: 309.1 Fire Protection. Fire protection systems shall be provided where required by the building code. Exception: An emergency voice/alarm communications system is not required for outdoor bleachers and grandstands provided all of the following are met: 1. The bleacher/grandstand has an occupant load of less than 15,000; 2. An public address system is provided; 3. Enclosed space located under seating are less than 1,000 square feet aggregate; 4. Enclosed space immediately adjacent to seating and not under the seating are limited to less than 3,000 square feet aggregate; and 5. All portions of the means of egress in the seating area are essentially open to the outside. Reason: The requirement for a voice alarm system with emergency power is inappropriate for small open air venues such as high school grandstands. These facilities often have limited electrical power and no access to generators or other approved emergency power sources by virtue of their locations remote from the main school. Additionally, the regular use of a public address system is more than ample for notifying spectators of an emergency condition. The presence of an alarm system brings into question the means for activation. If there are no sprinklers in an open air grandstand, then the activation method must be by manual (pull) stations. Placement of manual stations in a grandstand invites mischief and vandalism.

Page 9 of 21 When the voice alarm provisions were included into the building codes, the provision was taken from the Uniform Fire Code (UFC) that had provisions for fire alarms for large occupant load facilities (Group A, Divisions, A, 2 and 2.1) but which delineated open air facilities as a separate division of assembly occupancies (Group A Division 4). Alarms were only required for the former and not the latter as late as the 1991 UFC. When the UFC was restructured from the 1991 edition to the 1994 edition, the information was moved to Chapter 10 of the UFC but still maintained the link between the when required (1007.2.2.1) and the system initiation (107.2.2.2) as well as the emergency power requirements (1007.2.2.3). This concept was continued with the 1997 UFC which introduced the 1000 occupant threshold for the voice alarm. The only intent was to introduce this threshold not to expand the application to other Group A occupancies. Those using the UFC understood this and possessed the corporate memory to understand the intent. When the provisions were adopted into the International codes, this linkage was lost and the corporate memory was lost to the new parts of the country. Thus, the fire alarm became required for all Group A (assembly) occupancies including the outdoor venues which had never had fire alarm requirements in the past. Since the introduction of the International Building Code (IBC) and International Fire Code (IFC) this has been an item that has been dealt with on a local level to varying degrees of success. Those jurisdictions with corporate memory acknowledge that the requirement makes little sense for small grandstands and bleacher arrangements. In the other two thirds of the country, this is applied without regard to history or rationale. It is in the code and therefore must be applied. Prior to the IBC and IFC coming into existence, only the Standard Fire Prevention Code and Standard Building Code required fire alarms for all Group A occupancies. However, the practical applications and intent of that provision allowed for exceptions to be made on a local basis for small venues. Thus, smaller, open air venues regularly were constructed without any fire alarm in all of the three legacy codes. The limitations included in the exception are intended to make sure that the smaller venues can be exempted from the voice alarm requirements while making sure that larger venues are provided with the necessary back-up to the public address system. The threshold of 15,000 was selected because is seems to be a number around which concourses below the grandstands begin to be used and relates to the threshold at which the aisle width used for outdoor facilities is provided with a different factor (Table 404.5(3)). Using a common factor reduces the likelihood of erroneous application of the standards provisions. Where individual enclosed areas exceed 1,000 square feet, sprinklers are required for those areas according to the building code. Thus, an activation method exists for fire alarm and voice alarm initiation. The limitation of 3,000 square feet for areas away from below seating allows for larger spaces but requires that they be located away from seating. The final item in the exception list assures that even if the circulation areas outside the grandstands are unconditioned, if they could limit the ability of smoke to dissipate by virtue of sides and roof, they cannot be used. A portion of the language was taken from that used to describe the free ventilation for pedestrian bridges; more restrictive than what is required for open parking garages. This exception sets a threshold for something that has been variously allowed to exist or strictly disapproved. The fact that the provision has been applied inconsistently is a clear indication that some adjustment must be made. The proposal sets reasonable limits on the voice alarm threshold. Staff note: See attachment with code changes E142-09/10 which added Section 1028.1.1 to the 2012 IBC. Most spaces under seating are now required to be separated. Committee Action: Approved as Modified Replace the proposal as follows: 309.1 Fire Protection. Fire protection systems shall be provided where required by the building code. Exception: An emergency voice/alarm communications system for outdoor bleachers and grandstands installed in accordance with NFPA 101 shall be permitted. Committee Reason: The proposal was modified because an emergency voice/alarm communication system is addressed in NFPA 101. Reliability and features are covered in a practical and efficient

Page 10 of 21 manner. Some facilities have allowed this alternative, but enforcement has been inconsistent. The new exception will allow these types of systems to be used and set a reasonable threshold on the system requirements. IS-BLE 5-10/11 ICC 300 Section 404.5, 404.5.1 (New), 405.5 Proponent: Daniel Victor, Interkal, LLC Revise as follows: 405.5 Uniform width. Those portions of aisles, where egress is possible in either of two directions, shall be uniform in required width and shall be measured in accordance with Section 404.5.1. 404.5 Required width. The clear width of aisles and other means of egress for indoor smoke-protected assembly seating shall not be less than the occupant load served by the egress elements multiplied by the appropriate factor in Table 404.5(1). The clear width of aisles and other means of egress for indoor assembly seating that is not smoke protected shall not be less than the occupant load served by the egress elements multiplied by the appropriate factor in Table 404.5(2). The clear width of aisles and other means of egress for outdoor smoke-protected assembly seating not be less than the occupant load served by the egress elements multiplied by the appropriate factor in Table 404.5(3). The total number of seats specified shall be those within the space exposed to the same environment. Aisles shall also comply with Section 405. 404.5.1 Measurement. The clear width of aisles and other means of egress shall be measured to walls, edges of seating and tread edges except for permitted projections. There shall be no obstructions in the required width of aisles except for handrails as provided in Section 409.7. Reason: The required width is normally considered to vary with the number of occupants passing a particular point along the aisle within the catchment area. I believe this clarifies the intent. Revisions to Section 404.5 will help narrow down the reference. Committee Action: Approved as submitted Committee Reason: This clarifies the intent of the aisle width provisions and how they should be measured. IS-BLE 6-10/11 ICC 300 Section 405.6 Proponent: Daniel Victor, Interkal, LLC

Page 11 of 21 Revise as follows: 405.6 Dead ends. The length of a dead-end aisle shall not exceed 16 rows in nonsmoke-protected assembly seating and 21 rows in smoke-protected assembly seating. Exceptions: Dead-end aisles terminating at a cross aisle or vomitory providing access to an exit at only one end and complying with any one of the following shall be permitted. 1. In nonsmoke-protected assembly seating, dead-end aisles exceeding 16 rows are permitted where seats beyond the 16 th row are no more than 24 seats from another aisle, measured along a row of seats having an aisle accessway with a minimum clear width of 12 inches (305 mm) plus 0.6 inch (15.2 mm) for every additional seat beyond seven where seats have backrests or beyond ten where seats are without backrests in the row. 2. For smoke-protected seating, dead-end aisles exceeding 21 rows are permitted where seats beyond the 21 st row are no more than 40 seats from another aisle, measured along a row of seats having an aisle accessway with a minimum clear width of 12 inches (305 mm) plus 0.3 inch (7.6 mm) for each additional seat beyond seven where seats have backrests or beyond ten where seats are without backrests in the row. Reason: I believe this proposal clarifies the intent. This will coordinate with the proposed revisions to Section 407. See the reason statements for those proposals. Committee Action: Approved as Submitted. Committee Reason: This is approved for consistency with the revisions to Table 407.5 and is consistent with the committee action for proposals 6, 8, 9 and 10. See the reason on IS-BLE-10-10/11. IS-BLE 7-10/11 ICC 300 Section 407.2 Proponent: Brian Boudreau, Hussey Seating Company Revise as follows: 407.2 Minimum width. Where seating rows have 14 or fewer seats, the minimum clear aisle accessway width shall not be less than 12 inches (305 mm) measured as the clear horizontal distance from the back of the row ahead and the nearest projection of the row behind. Where chairs have automatic or self-rising seats, the measurement shall be made with seats in the raised position. Where any seat in a row does not have an automatic or self-rising seat, the measurements shall be made with the seat in the down position. For seats with folding tablet arms, row spacing shall be determined with the tablet arm down in the use position.

Page 12 of 21 Exception: For seats with folding tablet arms, row spacing is permitted to be determined with the tablet arm in the stored position where the tablet arm when raised manually to a vertical position in one motion automatically returns to the stored position by force of gravity. Reason: Promote consistency in text between section 1028.10 in IBC 2009 and section 407.2 in ICC 300 2007. The term down for the position of the tablet arm lacks clarity. A tablet arm has two positions stored and use positions. The 2007 Supplement to IBC addressed this lack of clarity and removed the term down and replaced it with in the use position. The exception noted above was also added to the 2007 Supplement to provide additional clarity. Staff note: Section 1028.10 was revised by E158-06/07. See attachment for code change history Committee Action: Approved as Submitted. Committee Reason: This proposal clarifies what down means and is consistent with IBC 1028.10 and NFPA 101. IS-BLE 8-10/11 ICC 300 Section 407.3 Proponent: Daniel Victor, Interkal, LLC Revise as follows: 407.3 Dual access. For rows of seating served by aisles or doorways at both ends, there shall not be more than 100 seats per row. The minimum clear width of 12 inches (305 mm) between rows shall be increased by 0.3 inch (7.6 mm) for every additional seat beyond 14 where seats have backrests or beyond 21 where seats are without backrests.,but The minimum clear width is not required to exceed 22 inches (559 mm). Exceptions: 1. For smoke-protected assembly seating, the row length limits for a 12-inch-wide (305 mm) aisle accessway, beyond which the aisle accessway minimum clear width shall be increased in accordance with Section 407.5. 2. Where seats are with out backrests, 21 seats between aisles shall be permitted with a minimum clear width of 12 inches (305 mm). Reason: The question is dealing with Exception 1. Is the 21 maximum number of seats in a row without backrests or does 21 replace 14 (as shown in Table 407.5) to which additional seats can be added to the 21 seats by using the formula for additional seats when there is a wider aisle accessway beyond 12 inches? The same question is also for Section 407.4, Exception 2, only the numbers are 10 and 7. I believe that the intent of the exceptions for seats without backs is to allow the replacement of an increased number of seats before the access aisle is required to exceed 12 inches. Once the increased number is exceeded in a dual access or single access row, the calculation for the increased access aisle width would start at this point. Example of dual access: Seats with backs 30 seats; 30 14 = 16; 16 x 0.3 + 12 = 16.8 minimum access aisle width

Page 13 of 21 Seats without backs 30 seats; 30 21 = 7; 7 x 0.3 + 12 = 14.1 minimum access aisle width This is in recognition that when exiting, persons are not necessarily regulated to the access aisle they started in by the seat configuration. In bench style bleachers, people could travel across rows. While not specifically stated in Section 407.5, I do believe that it is the intent of the 14 seats and 7 seats in the row titled, Less than 4,000 seats to allow those numbers to be replaced with 21 and 10 when the seats do not have backs. This is in recognition of the increased exiting time allowed in outdoor or smokeprotected seating areas. If the seat numbers in the following rows should be increased at a greater rate than indicated is not information currently addressed in the ICC 300. A conservative approach would be to increase the access aisle width in the same increments as permitted in the table. Committee Action: Approved as Modified. Modify the proposal as follows: 407.3 Dual access. For rows of seating served by aisles or doorways at both ends, there shall not be more than 100 seats per row. The minimum clear width of 12 inches (305 mm) between rows shall be increased by 0.3 inch (7.6 mm) for every additional seat beyond 14 where seats have backrests or beyond 21 where seats are without backrests. The minimum clear width is not required to exceed 22 inches (559 mm). Exceptions: 1. For smoke-protected assembly seating, the row length limits for a 12-inch-wide (305 mm) aisle accessway, beyond which the aisle accessway minimum clear width shall be increased in accordance with Section 407.5. 2. Where seats are with out backrests, 21 seats between aisles shall be permitted with a minimum clear width of 12 inches (305 mm). Committee Reason: The modification to delete the exception was because the text has moved into the base paragraph so the exception is no longer needed. This is approved for consistency with the revisions to Table 407.5 and is consistent with the committee action for proposals 6, 8, 9 and 10. See the reason on IS-BLE-10-10/11. IS-BLE 9-10/11 ICC 300 Section 407.4 Proponent: Daniel Victor, Interkal, LLC Revise as follows: 407.4 Single access. For rows of seating served by aisles or doorways at only one end of the row, the minimum clear width of 12 inches (305 mm) between rows shall be increased by 0.6 inch (15.2 mm) for every additional seat beyond seven seats where seats have backrests or beyond ten where seats are without backrests.,but The minimum clear width is not required to exceed 22 inches (559 mm). The path of egress travel, how ever, shall not exceed 30 feet (9144 mm) from any seat to a point where a person has a choice of two paths of egress travel to two exits. Where one of the two paths of travel is across the aisle through a row of seats to another aisle, there shall not be more than 24 seats between the two aisles; and the minimum clear width between rows for the row between the two aisles shall be 12 inches (305 mm) plus 0.6 inch (15.2

Page 14 of 21 mm) for each additional seat above seven in the row between aisles. Exceptions: 1. For smoke-protected assembly seating, the row length limits for a 12-inch-wide (305 mm) aisle accessway, beyond which the aisle accessway minimum clear width shall be in creased, are in Table 407.5. 2. Where seats are with out backrests, a maximum of 10 seats to an aisle shall be permitted with a minimum clear width of 12 inches (305 mm). 3. In smoke-protected assembly seating, the path of egress travel shall not exceed 50 feet (15 240 mm) from any seat to a point where a person has a choice of two paths of egress travel to two exits. Reason: I believe this clarifies the intent. See the reason for the proposal to Section 407.3. Committee Action: Approved as Submitted. Committee Reason: This is approved for consistency with the revisions to Table 407.5 and is consistent with the committee action for proposals 6, 8, 9 and 10. See the reason on IS-BLE-10-10/11. IS-BLE 10-10/11 ICC 300 Table 407.5 Proponent: Daniel Victor, Interkal, LLC Revise as follows: 407.5 Smoke-protected aisle accessways. The design of smoke-protected aisle accessways shall comply with Table 407.5. TABLE 407.5 SMOKE-PROTECTED AISLE ACCESSWAYS TOTAL NUMBER OF SEATS IN THE SMOKE MAXIMUM NUMBER OF SEATS PER ROW PERMITTED TO HAVE A MINIMUM 12-INCH CLEAR WIDTH AISLE ACCESSWAY Aisle or doorway at one end of row PROTECTED Aisle or doorway at both ends of row only ASSEMBLY OCCUPANCY Seats with backrests Seats without backrests Seats with backrests Seats without backrests Less than 4,000 14 21 7 10 4,000 15 22 7 10 7,000 16 23 8 11 10,000 17 24 8 11 13,000 18 25 9 12 16,000 19 26 9 12 19,000 20 27 10 13 22,000 and greater 21 28 11 14 For SI: 1 inch = 25.4 mm.

Page 15 of 21 Reason: This proposal is an extension of the recognition of the fact that bench seating without backrests allows easier and quicker lateral movement along a bleacher row as compared with rows of seat which are provided with backrests (ref. ICC 300 Section 407.3 Exception 2.) Committee Action: Approved as Submitted. Committee Reason: This is consistent with the committee action for proposals 6, 8, 9 and 10. Allowances for aisle accessways for seats without backrests were already permitted in Sections 407.3 and 407.4. By including the allowance in the base paragraphs (instead of exceptions) and Table 407.5, the allowance is more clearly understood. IS-BLE 11-10/11 ICC 300 Section 409.5.1 Proponent: Daniel Victor, Interkal, LLC Revise as follows: 409.5.1 Mid-aisle handrail termination. Mid-aisle handrails shall not extend beyond the lowest riser and shall terminate within 30 inches (762mm) 18 inches (381mm) measured horizontally, from the face of the lowest riser. Exception: Mid-aisle handrails shall be permitted to extend beyond the lowest riser where the handrail extensions do not obstruct the required width of the cross aisle. Reason: In some instances, such as where there is no cross-aisle at the bottom of the aisle, it is desirable to extend the handrail beyond the first riser similar to requirements for stairways in buildings (ref. 2009 IBC 1012.6). The proposed revision allows, but does not require the extension. Assuming decent of the aisle, it is necessary to reach backward to keep a hand on the rail while stepping off the bleacher. Section 409.1.1 allows a maximum 36 inch gap between handrails. At the midpoint between, an occupant would be required to reach either forward or backward 18 inches. 30 inches is recognized as an allowable reach sideways, but may not be appropriate as a rearward reach limit. Committee Action: Approved as Modified. Modify the proposal as follows: 409.5.1 Mid-aisle handrail termination. Mid-aisle handrails shall not extend beyond the lowest riser and shall terminate within 18 inches (381mm) measured horizontally, from the face of the lowest riser. Handrail extensions are not required. Exception: Mid-aisle handrails shall be permitted to extend beyond the lowest riser where the handrail extensions do not obstruct the required width of the cross aisle. Committee Reason: The addition of the last sentence in the main paragraph is editorial. It is existing text that was inadvertently left out of the original proposal. The word required is struck so that a designer could choose to provide a wider cross aisle. Handrail extensions should not be an obstruction in any cross ails. This proposal will reduce falls by placing the handrail closer to the bottom of the aisle

Page 16 of 21 stairs without interfering with the cross aisle. The 30 inches previously indicated was from research for side reach for handrails. IS-BLE 12-10/11 ICC 300 Section 502.2.1(New) Proponent: Greg Nelson, BR Bleachers, Co. Add new text as follows: 502.2.1 Repairs required. Where occupancy or operation of the seating system is found to be unsafe, the seating shall not be used, (in whole or in part) or operated until complete repairs restoring safe use are completed. Reason: Specifies that owners may not use or operate any part of defective or damaged seating until proper repairs are made, regardless of when the last annual inspections were conducted. Facilities have used defective seating when severe damage has been reported. They instruct spectators to avoid the defective area and cite the fact that the annual inspections were recently completed, in defense of their instructions. This recommendation includes requirements that unsafe conditions are promptly reported. Committee Action: Approved as Modified Replace the proposal with the following: 502.2.1 Application. Bleachers, Folding and Telescopic Seating and Grandstand systems included in this standard must be maintained in good repair and structurally sound so not to pose a threat to the public health, safety or welfare. 502.2.2 Unsafe conditions. Seating shall comply with Chapter 5 and the applicable sections of the International Property Maintenance Code, Sections 304 and 305. In seating areas affected by damage, unsafe operation or defects that interfere with safe use shall not be used or operated until satisfactory repairs restoring safe use is completed. 502.2.3 Notification. Written or oral notice shall be provided to the owner or owner s representative of the unsafe condition upon discovering the defective conditions. Committee Reason: The revised proposal utilizes existing criteria for safety in the International Property Maintenance Code. This should address unsafe conditions that occur between inspections so that the public using the bleachers are safe. The proposal limits the portion of the bleacher not to be used to the damaged area. This would allow for someone to partition off a portion until repairs are made rather than closing the entire bleacher. IS-BLE 13-10/11 ICC 300 Section 503.1, 503.1.1(New)

Page 17 of 21 Proponent: Greg Nelson, BR Bleachers, Co. Revise as follows: 503.1 Required guards. Guards shall be provided in the following areas. 1. Along open-sided walking surfaces, cross aisles, stepped aisles, ramps and landings of tiered seating areas which are located more than 30 inches (762 mm) above the floor or grade below. Such guards shall be not less than 36 inches (914 mm) high, measured vertically above the leading edge of the tread, adjacent walking surface or center of adjacent bench seat. Exceptions: 1. Where the upper most seat is located less than or equal to 55 inches (1397 mm) above the floor or ground below. 2. Where located adjacent to a wall and the space between the wall and the tiered seating is less than 4 inches (102 mm). 2. Unless subject to the requirements of Item 3, a guard with a minimum height of 26 inches (660 mm) shall be provided where the floor or footboard elevation is more than 30 inches (762 mm) above the floor or grade below and the guard would otherwise interfere with the sightlines of immediately adjacent seating. 2.3.A guard shall be provided for the full width of the aisle where the foot of the aisle is more than 30 inches (762 mm) above the floor or ground below. The guard shall be a minimum of 36 inches (914 mm) high. 503.1.1 Guard height. Existing guards shall be a minimum of 36 inches (914 mm) high, measured vertically above the leading edge of the tread, adjacent walking surface or center of adjacent bench seat. Guards that are replaced shall not be less than 42 inches (1067 mm) high, measured vertically above the leading edge of the tread, adjacent walking surface or center of adjacent bench seat. Exception: Unless subject to Section 503.1, Item 2, a guard with a minimum height of 26 inches (660 mm) shall be provided where the guard would otherwise interfere with the sightlines of immediately adjacent seating. Reason: Adds replacement requirement to meet current new standards. This is a minor concession since most rail systems are designed to meet the 42 inch height and will improve safety on existing seating. Committee Action: Dissapproved Reason: This is already addressed in Section 501.4 under alterations. IS-BLE 14-10/11 ICC 300 Section 505 (New)

Page 18 of 21 Proponent: Greg Nelson, BR Bleachers, Co. Add new text as follows: SECTION 505 EGRESS 505.1 Egress. Existing tiered seating shall comply with the egress requirements in Sections 401 through 407 and 409. Exceptions: 1. Where the uppermost seat board is located 55 inches (1397mm) or less above the floor or ground below the bleacher is not required to comply with Sections 405, 406, 407 or 409; 2. Where a bleacher has an occupant load of 100 or less the bleacher is not required to comply with Sections 405, 406, 407 or 409; or 3. Where modifying an existing seating structure to meet the aisle stair requirements in Section 406 would be technically infeasible. Reason: Clarifies rules for egress on existing seating and follows the basic existing seating standards already established without requiring new replacement of existing seating when meeting this standard would be impractical. Provides small stand (100 or < seat capacity) owners with an exception. Currently numerous schools question what is required and by what standard. Committee Action: Disapproved Committee Reason: Forcing existing bleachers to comply with current means of egress requirements could have a significant financial impact. The safety concerns for falls through opening under the seats have already been addressed. There has been no similar information indicating the need for aisle steps to be added. IS-BLE 15-10/11 ICC 300 Section 505 (New) Proponent: Greg Nelson, BR Bleachers, Co. Add new text as follows: SECTION 505 SEATING RELOCATION Section 505.1 Relocating existing bleachers. Relocating existing bleachers to a new location shall be permitted provided the existing bleacher complies with Sections 303.6, 304, 306, 307, 308 and 310 and Chapter 5. Exception: Compliance with Section 310 is not required when technically infeasible.

Page 19 of 21 Reason: Allows the re-use or relocation (due to floor replacement or gym layout redesign) of an existing seating system that can meets the same requirements as a seating system currently in place. This makes the standards for reusing existing seating clearer. Many owners ask if this is allowed and by what rules. It is assumed that the bleacher was designed for compliant loading. Sections 305, 309 and 311 are addressed in Chapter 5. Section 310, Accessibility, is required when the alteration would require movement of major structural elements for the bleacher. Committee Action: Approved as Modified Modify proposal as follows: SECTION 505 SEATING RELOCATION Section 505.1 Relocating existing bleachers. Relocating existing bleachers to a new location shall be permitted provided the existing bleacher complies with Sections 303.6, 304, 306, 307, 308 and 310 and Chapter 5. Exception: Compliance with Section 310 is not required when technically infeasible. Where full compliance with Sections 310.1 and 501.4 is technically infeasible, the relocated existing bleachers shall provide access in compliance with the building code to the maximum extent technically feasible. Committee Reason: The proposed revised language is more consistent with the IBC Chapter 34, the International Existing Building Code and the new ADA requirements. This would allow for existing bleachers that are safe to stay as is if compliance would involve revising major structural elements. This exception would typically be applicable to small bleacher systems or pull-out bleacher systems. IS-BLE 16-10/11 ICC 300 Section 405.2 Revise text as follows: 405.2 Minimum aisle width. The minimum clear width of aisles shall be as follows. 1. Forty-eight inches (1219 mm) for aisle stairs having seating on each side. Exception: Thirty-six inches (914 mm) where the aisle serves less than 50 seats. 2. Thirty-six inches (914 mm) for aisle stairs having seating on only one side. Exception: Twenty-three inches (584 mm) between an aisle stair handrail and seating where an aisle does not serve more than five rows on one side. 3. Twenty-three inches (584 mm) between an aisle stair handrail or guard and seating where the aisle has a mid-aisle handrail. 4. Forty-two inches (1067 mm) for level or ramped aisles having seating on both sides. Exceptions: 1. Thirty-six inches (914 mm) where the aisle serves less than 50 seats. 2. Thirty inches (762 mm) where the aisle does not serve more than 14

Page 20 of 21 seats. 5. Thirty-six inches (914 mm) for level or ramped aisles having seating on only one side. Exceptions: 1. Thirty inches (762 mm) where the aisle does not serve more than 14 seats. 2. Twenty-three inches (584 mm) between an aisle stair handrail and seating where an aisle does not serve more than five rows on one side. Reason: The purpose for the movement of Item 5, Exception 2 to Item 2, Exception is coordinate with IBC Section 1028.9.1 and E143-09/10. Below is the text in the IBC. The reason for the movement of the exception as given in E143-09/10 was The aisle width requirements became less clear when item #6 in the 2003 IBC became into an exception to Item #5 in the 2006 IBC, which remains in the 2009 IBC. The width of an aisle stair should not be an exception to a level or ramped aisle. Either it should be a separate item as it was in the 2003 IBC or an exception to an aisle stair with seating on one side. This proposal relocates the current exception to the appropriate aisle stair provision to maintain the format changes that has occurred over the last several editions. 1028.9.1 Minimum aisle width. The minimum clear width for aisles shall be as shown: 1. Forty-eight inches (1219 mm) for aisle stairs having seating on each side. Exception: Thirty-six inches (914 mm) where the aisle serves less than 50 seats. 2. Thirty-six inches (914 mm) for aisle stairs having seating on only one side. Exception: Twenty-three inches (584 mm) between an aisle stair handrail and seating where an aisle does not serve more than five rows on one side. 3. Twenty-three inches (584 mm) between an aisle stair handrail or guard and seating where the aisle is subdivided by a handrail. 4. Forty-two inches (1067 mm) for level or ramped aisles having seating on both sides. Exceptions: 1. Thirty-six inches (914 mm) where the aisle serves less than 50 seats. 2. Thirty inches (762 mm) where the aisle does not serve more than 14 seats. 5. Thirty-six inches (914 mm) for level or ramped aisles having seating on only one side. Exception: Thirty inches (762 mm) where the aisle does not serve more than 14 seats. Committee Action: Approved as Submitted Committee Reason: The coordination with IBC is appropriate for bleachers. IS-BLE 17-10/11 ICC 300 Section 406.6.2 Revise text as follows: 406.6.2 Tread marking stripe. Where tread or riser nonuniformity exceeds 0.188 inch (4.8 mm), a distinctive marking stripe shall be provided on each tread adjacent to the non uniform tread or riser. The marking shall be provided on each tread at the nosing or leading edge such that the location of each tread is readily apparent when viewed in de scent. Such stripe shall be a minimum of 1 inch (25 mm) wide and a maximum of 32 inches (76 51 mm) wide. Exception: The contrasting marking stripe is permitted to be omitted where tread surfaces are such that the location of each tread is readily apparent when viewed in descent.

Page 21 of 21 Reason: The revision to the stripe width is for coordination with IBC 1028.11.3. 1028.11.3 Tread contrasting marking stripe. A contrasting marking stripe shall be provided on each tread at the nosing or leading edge such that the location of each tread is readily apparent when viewed in descent. Such stripe shall be a minimum of 1 inch (25 mm), and a maximum of 2 inches (51 mm), wide. Exception: The contrasting marking stripe is permitted to be omitted where tread surfaces are such that the location of each tread is readily apparent when viewed in descent. Committee Action: Approved as submitted Committee Reason: The consistency with IBC is practical and consistent with current practices. The ICC 300 committee did not have provisions for tread marking stripes to draw on at the time of development.