CONFINEMENT EFFECT OF FRP AND TRANSVERSE STEEL ON RETROFITTING SQUARE CONCRETE COLUMNS

Similar documents
Behaviour of FRP wrapped circular reinforced concrete columns

Behaviour of FRP wrapped circular concrete columns under eccentric loading

RESPONSE OF SUBSTANDARD REINFORCING DETAILS T CONNECTIONS UPGRADED WITH CONCRETE COVERS AND CFRP

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

P R O O F ONL Y. Columns under Axial Compression. Confinement Mechanism

RETROFITTING OF COLUMNS WITH RC JACKETTING AN EXPERIMENTAL BEHAVIOR

SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP)

Experimental Behavior of Concrete Cylinders Confined with CFRP Composites

EXPERIMENTAL STUDY ON RC COLUMNS RETROFITTED BY FRP AND SUBJECTED TO SEISMIC LOADING

Upgrading the shear strength of non-ductile reinforced concrete frame connections using FRP overlay systems

A Study on Hybrid FRP Wrapped Axially Loaded RC Capsule Column

Slenderness ratio effect on the behavior of steel and carbon-frp reinforced concrete-filled FRP tubes

Effect of Bar-cutoff and Bent-point Locations on Debonding Loads in RC Beams Strengthened with CFRP Plates

SEISMIC RETROFIT OF A TYPICAL REINFORCED CONCRETE BUILDING THROUGH FRP JACKETING OF EXTENDED RECTANGULAR COLUMNS

AXIAL TESTING OF CONCRETE COLUMNS CONFINED WITH CARBON FRP: EFFECT OF FIBER ORIENTATION. Abstract

AN INNOVATIVE DUCTILE COMPOSITE FABRIC FOR STRENGTHENING CONCRETE STRUCTURES. Abstract

Jagannathan Saravanan et al IJCSET January 2012 Vol 2, Issue 1,

Behaviour of Post-Installed GFRP Adhesive Anchors in Concrete

USE OF CFRP ANCHORS TO STRENGTHEN LAP SPLICES OF RECTANGULAR RC COLUMNS

Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

Moment curvature analysis of concrete flexural members confined with CFRP grids

Comparison of Prefabricated Cage System with Existing Reinforcement Methods in Concrete Columns

Experimental Evaluation of Noncircular Reinforced Concrete Columns Strengthened with CFRP

Investigation on Behaviour of Reinforced Concrete Beam Column Joints Retrofitted with FRP Wrapping

FLEXURAL IMPROVEMENT OF PLAIN CONCRETE BEAMS STRENGTHENED WITH HIGH PERFORMANCE FIBRE REINFORCED CONCRETE

Behaviour of perforated GFRP tubes under axial compression

GFRP retrofitted RC frames with columns subjected to high axial stresses

Experimental study on FRP tube reinforced concrete columns under different loading conditions

(FRP) ( CFRP

Dynamic Compressive Behavior of FRP-Confined Concrete Under Impact and a New Design-Oriented Strength Model

MECHANICAL CHARACTERIZATION OF SANDWICH STRUCTURE COMPRISED OF GLASS FIBER REINFORCED CORE: PART 1

Effects Of Slenderness Ratio In RC Slender Column Using GFRP And CFRP Confinement

ABSTRACT. KEY WORDS: Tubular piles; composite behavior; offshore structures; push-out strength; bond strength; slip.

In-plane testing of precast concrete wall panels with grouted sleeve

FE MODELING OF CFRP STRENGTHENED CONCRETE BEAM EXPOSED TO CYCLIC TEMPERATURE, HUMIDITY AND SUSTAINED LOADING

Performance based Displacement Limits for Reinforced Concrete Columns under Flexure

Performance of NSM FRP strengthened concrete slabs at low temperatures

THE PERFORMANCE OF CONCRETE GROUND FLOOR SLAB REINFORCEMENT TO CONTROL SHRINKAGE CRACKING. D H Chisholm 1

Tests on FRP-Concrete Bond Behaviour in the presence of Steel

PRELOADING EFFECT ON LOAD CAPACITY AND DUCTILITY OF RC BEAMS STRENGTHENED WITH PRESTRESSED CFRP STRIPS

Optimized FRP wrapping schemes for circular concrete columns under axial compression

IMPROVEMENT OF THE DEFORMATION CAPACITY BY THE USE OF FIBERS

POST-STRENGTHENING OF MASONRY COLUMNS BY USE OF FIBER-REINFORCED POLYMERS (FRP) Abstract

GFRP-STEEL HYBRID REINFORCED CONCRETE BRIDGE DECK SLABS IN QUEBEC, CANADA

CFRP STRENGTHENING OF CONCRETE BRIDGES WITH CURVED SOFFITS

INHERENT DUCTILITY OF REINFORCED CONCRETE SHEAR WALLS WITH NON-SEISMIC DETAILING

PERFORMANCE STUDY OF RETROFITTED GRAVITY LOAD DESIGNED WALL FRAME STRUCTURES (SC-140)

GFRP HOLLOW-CORE REBARS FOR CONCRETE BEAMS

Behavior of Concrete-Filled FRP Tubes Under Bending, Axial Loads, and Combined Loading. Amir Fam, Bart Flisak and Sami Rizkalla

SEISMIC TEST OF CONCRETE BLOCK INFILLED REINFORCED CONCRETE FRAMES

INNOVATIVE SEISMIC RETROFITTING OF OLD-TYPE RC COLUMNS THROUGH JACKETING: TEXTILE-REINFORCED MORTARS (TRM) VERSUS FIBER-REINFORCED POLYMERS (FRP)

EXTERNAL CONFINEMENT OF PLAIN AND REINFORCED CONCRETE COLUMNS USING PVC PIPES

EXPOSURE TEST AND LONG-TERM CHARACTERISTICS FOR CFRP STRUCTURAL MEMBERS

SEISMIC STRENGTHENING OF A PRECAST REINFORCED CONCRETE WALL PANEL USING NSM-CFRP

FIBER REINFORCED CEMENT BASED COMPOSITE SHEETS FOR STRUCTURAL RETROFIT

Strengthening Concrete Sections by FRP Materials

Rectangular Filament-Wound GFRP Tubes Filled with Concrete under Flexural. and Axial Loading: Experimental Investigation ABSTRACT

optimal design of frp retrofitting for seismic resistant rc frames C. Chisari 1, C. Bedon 2 1

406 A.R. Khaloo and A. Esmaili This method does not enhance column moment capacity and stiness signicantly. Therefore, additional earthquake forces in

7.1 Transmission of Prestress (Part I)

THE EFFECT OF FATIGUE LOADING ON BOND STRENGTH OF CFRP BONDED STEEL PLATE JOINTS

Beam Pull Out Tests of NSM FRP and Steel Bars in Concrete

Sustainable Shear Behaviour of 2-Span Continuous Reinforced Concrete T-Beams with CFRP Strips

SEISMIC RETROFIT OF BEAM-COLUMN JOINTS WITH FRP SHEETS

CYCLIC BEHAVIOR OF SLENDER R/C COLUMNS WITH INSUFFICIENT LAP SPLICE LENGTH

Strengthening of hollow core precast slabs using FRP composite materials procedure, testing and rating

Application of Tensioned CFRP Strip Method to an Existing Bridge

Modelling of RC moment resisting frames with precast-prestressed flooring system

Rotational capacity of railway prestressed concrete sleeper under static hogging moment

THE DESIGN OF EXTERNALLY BONDED REINFORCEMENT (EBR) FOR REINFORCED CONCRETE STRUCTURES BY MEANS OF FIBRE REINFORCED POLYMERS (FRP)

Bond performance of patching materials subjected to environmental effects

Structural Upgrade of Reinforced Concrete Column-Tie Beam Assembly using FRP Composites

Bond Characteristics of GFRP Sheet on Strengthened Concrete Beams due to Flexural Loading

Deformation Capacity of RC Structural Walls without Special Boundary Element Detailing

The Development of Strain Penetration in Lightly Reinforced Concrete Shear Walls

STRUCTURAL CHARACTERISTICS OF CONCRETE-FILLED GLASS FIBER REINFORCED COMPOSITE PILES. Abstract

Address for Correspondence

Deflection Assessment of an FRP-Reinforced Concrete Bridge. By Danielle K. Stone, Andrea Prota, and Antonio Nanni

Structural health monitoring of structures repaired with FRP

Hybrid Reinforced Concrete Frame Building with Pumice Brick Masonry Infill under Static Lateral Loading

DUCTILITY REQUIREMENTS FOR BUILDINGS

Behavior and Strength of Bearing Wall Strengthening by CFRP

Strengthening of Reinforced Concrete Beams using Near-Surface Mounted FRP Mohamed Husain 1, Khaled Fawzy 2, and Mahmoud Nasr 3

Site Director: Dr. Sami Rizkalla Associate Director: Dr. Rudi Seracino Date: February 1 st, 2011

Design of Rigid Pavements

EXPERIMENTAL ANALYSIS ON THE SHEAR BEHAVIOUR OF RC BEAMS STRENGTHENED WITH GFRP SHEETS

ALKALI AGGREGATE REACTIVE MORTAR CYLINDERS PARTLY RESTRAINED BY EXTERNAL CFRP FABRIC EXPANSION AND CONFINEMENT

STRENGTHENING STEEL-CONCRETE COMPOSITE BRIDGES WITH HIGH MODULUS CARBON FIBER REINFORCED POLYMER (CFRP) LAMINATES

Finite Element Modelling of RC Beams Retrofitted with CFRP Fabrics

Strengthening of infilled RC frames by CFRP

Hybrid FRP-Concrete Structural Member: Research and Development in Europe and Asia

Reinforced concrete edge beam column slab connections subjected to earthquake loading

CFRP Strengthening and Load Testing of the Concrete Deck of I-10 KCS Railroad Overpass Mohsen Shahawy, Ph.D, PE SDR Engineering Consultants, Inc.

REVIEW ON SHEAR SLIP OF SHEAR KEYS IN BRIDGES

A PRODUCT FROM KANTAFLEX (INDIA) PVT LIMITED

1.7 Prestressing Steel

USE OF 500 GRADE STEEL IN THE DESIGN OF REINFORCED CONCRETE SLAB. Prof. M. Shafiul Bari, Ph.D Department of Civil Engg., BUET

UHPC Connection of Precast Bridge Deck

FINITE ELEMENT ANALYSIS OF REINFORCED CONCRETE BRIDGE PIER COLUMNS SUBJECTED TO SEISMIS LOADING

Transcription:

Fourth Asia-Pacific Conference on FRP in Structures (APFIS 2013) 11-13 December 2013, Melbourne, Australia 2013 International Institute for FRP in Construction CONFINEMENT EFFECT OF FRP AND TRANSVERSE STEEL ON RETROFITTING SQUARE CONCRETE COLUMNS Le V. Doan, Xu Lei, Thong M. Pham and Muhammad N.S. Hadi * School of Civil, Mining & Environmental Engineering, University of Wollongong, Wollongong, NSW, Australia * Email: mhadi@uow.edu.au. ABSTRACT This study presents an experimental investigation into strain distribution of Fibre-Reinforced Polymer (FRP) in FRP-confined concrete columns with internal steel reinforcement under concentric and eccentric loading conditions. A total of nine reinforced concrete columns were cast and tested. Three of them were square in crosssection while the others were originally square but were shape-modified into circular columns with four pieces of segmental circular concrete covers and confined with three layers of CFRP. The nominal compressive strength of the segmental concrete covers was 40 MPa and 80 MPa. All columns were tested under concentric load, 25 mm or 50 mm eccentric load. Strain distribution was obtained by a number of strain gauges located symmetrically around the circumference of the columns. The CFRP strain distribution in the hoop direction and the hoop rupture strain of the shape-modified reinforced concrete columns under different load eccentricity was examined. Moreover, the load-carrying capacity and ductility were compared with columns with different volumetric ratio of transverse steel reinforcement from a previous study to discover the effect of transverse steel confinement on the ductility of FRP-confined columns under both concentric and eccentric load. Results showed that the hoop strain distribution for eccentrically loaded columns was not uniform with the maximum strain that occurred at the extreme compression fibre while the minimum strain occurred at the extreme tension fibre of the columns. The variation of the CFRP hoop strain increased when the eccentricity increased. In addition, columns with different volumetric ratio of transverse steel reinforcement had similar normalised stress and ductility, suggesting that transverse steel reinforcement is insignificant effect on the load-carrying capacity and ductility of FRP-confined columns. KEYWORDS Shape modification, eccentric loading, strain distribution, confinement. INTRODUCTION Fibre-Reinforced Polymer (FRP) provides passive confining pressure to restrain the lateral expansion of concrete columns under axial loading. Previous studies indicated that the compressive strength and the ultimate strain of FRP-confined concrete are closely related to the confining pressure provided by the FRP jacket when it ruptures (Lam and Teng 2003; Pessiki et al. 2001). However, the majority of these theoretical models focused on columns under concentric loading. It is apparent that columns under eccentric loading exhibit non-uniform expansion in the hoop direction and therefore the strain distribution in the FRP jacket would be non-uniform. To better understand the strain distribution in the FRP jacket of eccentrically loaded concrete columns, an experimental program is presented in this study evaluating the strain distribution in the FRP jackets for the columns under both concentric and eccentric loading conditions. A theoretical study by Pellegrino and Modena (2010) revealed that internal transverse steel reinforcement influences the behaviour of FRP-confined columns by contributing transverse confining pressure. Theoretical models which neglect the confining pressure may underestimate the stress-strain behaviour of the FRP-confined columns with internal reinforcement. The effect of internal transverse steel reinforcement is validated in the latter part of this study by comparing test results of FRP-confined columns with different volumetric ratio of internal transverse steel reinforcement.

EXPERIMENTAL PROGRAM Tests on nine columns were conducted in the High Bay of the Civil Engineering Laboratory of the University of Wollongong. Details of the experimental program are presented in this section. Design of Specimens The dimension of each square column was 150 mm in sides and 800 in height. All the columns were made of normal strength concrete (NSC) and the steel reinforcement of columns were designed in accordance with AS 3600 (2009) with a small amount of internal steel reinforcement. Longitudinal steel reinforcement consisted of four 12 mm (N12) deformed bars with a nominal tensile strength of 500 MPa tied inside by transverse steel reinforcement. The diameter of the transverse steel reinforcement was 6 mm (R6) with a nominal tensile strength of 250 MPa, which was placed at 60 mm spacing. The clearance between the steel reinforcement and the mould was maintained at 20 mm on each side, at the top and the bottom. Six of the test specimens were shape-modified by bonding four segmental circular plain concrete covers to each side. Segmental circular plain concrete covers were cast with NSC and high strength concrete (HSC), with a nominal compressive strength of 40 MPa and 80 MPa, respectively. The modified columns were then confined with three layers of CFRP. Figure 1 shows the design details of the specimens. (a) Square column (b) Shape-modified column (c) Cross section Figure 1. Design details of the specimens In total, nine RC columns were tested and subdivided equally into three groups. From each group, the columns were tested under concentric loading or eccentric loadings with 25 mm and 50 mm eccentricity. Details of the specimens are presented in Table 1. The labelling used for the specimens is composed of a combination of letters and numbers. The letters R and C denote the reference columns and the shaped-modified columns, respectively. The numbers 40 and 80 express the nominal compressive strength of the segmental circular concrete covers which were bonded to the existing square RC columns. The last number 0, 25 and 50 denote the eccentricity of the axial loading. For example, Specimen C80-50 is the shape-modified column with concrete covers of 80 MPa and tested under an eccentric loading of 50 mm. Table 1. Configuration of specimens Specimen Concrete strength at test time (MPa) Steel Number of Eccentricity Existing column Concrete cover reinforcement CFRP layers (mm) R-0 4N12 0 R-25 44 - and - 25 R-50 R6@60 mm 50 C40-0 4N12 0 C40-25 58 58 and 3 25 C40-50 R6@60 mm 50 C80-0 4N12 0 C80-25 59 98 and 3 25 C80-50 R6@60 mm 50

Construction of shaped modified specimens Two wooden formworks for casting existing square columns and segmental circular concrete covers in this experimental program were used as illustrated by Hadi et al. (2013). The wooden panels for casting the existing columns had internal cross-sections of 150 by 150 mm and 800 mm in height. The second formworks for casting the segmental circular concrete covers had internal cross-sections of 170 by 51 mm and 800 mm in height. Special forms were also used to fit inside the second formworks to prepare the segmental circular covers. The segmental circular concrete covers were taken out of the formworks after 28 days. The contact surfaces between the segmental covers and the existing columns were ground using a wire brush and an electric grinder in order to achieve a smooth surface. Four segmental circular concrete covers were then bonded to the existing square columns with an admixture, which was made from epoxy resin, slow hardener, and silica microsphere with a ratio of 5:1:10, as recommended by the manufacturer. These modified columns were then confined with three layers of CFRP. A wet lay-up method was applied to bond the CFRP to the columns with adhesive. The adhesive was prepared by mixing an epoxy resin and a slow hardener with a ratio of 5:1. Preliminary testing The average compressive strength of concrete at the testing day is shown in Table 1. The tests to measure the tensile strength of N12 deformed bars and R6 plain bars, 542 MPa and 499 MPa, respectively, was conducted in accordance with AS 1391 (2007). The CFRP was tested according to ASTM D3039 (2010) to determine its tensile strength. The test revealed that the tensile strength of the three layered CFRP was 2105 N/mm, corresponding maximum strain of 1.74 %. Specimen Testing All the columns were tested using the 5000 kn Denison testing machine to failure. In order to transfer the loading from the machine to the specimens uniformly, each column was levelled by high strength plaster at both ends. The eccentric loading was applied on the columns using the loading heads and the knife edges, as described by Hadi and Widiarsa (2012). The loading heads had two grooves, which were located at 25 mm and 50 mm from their centrelines. Strain gauges (SG) were attached onto the surface of the middle CFRP ring to investigate the actual strain of CFRP in the hoop direction. Four strain gauges were symmetrically bonded in all concentrically loaded columns while each eccentrically loaded column had ten strain gauges, as shown in Figure 2. More strain gauges were installed in the compression region due to the largest confining pressure of the CFRP in this region. The axial load was measured by the load cell of the 5000 kn Denison Compression machine at the University of Wollongong. Two LVDTs were attached to the lower plate of the loading machine to measure the axial deflection of the columns. For columns that were subjected to eccentric loading (25 mm and 50 mm), a laser triangulation was set up at the mid-height of the columns to record their lateral deflection. All specimens were tested under displacement control with a loading rate of 0.3 to 0.5 mm/min. RESULTS AND DISCUSSIONS Distribution of CFRP hoop strain under different loading conditions The CFRP strain in hoop direction (out of the overlap zone) of the concentrically loaded columns was almost uniform. However, the CFRP hoop strain became the largest at the extreme fibre in the compression region of the columns under the eccentric loading. Concentrically loaded columns The CFRP of concentrically loaded columns ruptured at the ultimate load. The CFRP hoop strain at rupture was calculated from the average values from the strain gauges outside the overlap zone. The average hoop strains in the CFRP at failure were approximately 1.29% and 1.05% for Specimens C40-0, C80-0, respectively. In addition, the smallest strain was always found within the overlap zone, which was about 75% of the average strain in CFRP at rupture. This is because the thickness of CFRP within the overlap zone was thicker than

outside the overlap zone. The strain in the jacket is inversely proportional to the thickness of the jacket for the same confinement pressure. Table 2. Results of CFRP strain at rupture for concentrically loaded columns Specimen C40-0 C80-0 Ultimate Load (kn) 3343 3462 CFRP strain at rupture (%) 1.29 1.05 CFRP strain in overlapping zone at failure (%) 1.01 0.81 Strain efficiency factor 0.74 0.60 Figure 2. Details of strain gauge positions As stated above, the average ultimate strain from flat coupon tests was 1.74%. The CFRP strain efficiency factor of these specimens, defined as the ratio of the actual hoop rupture strain to the ultimate strain of CFRP from flat coupon tests, are given in Table 2. Eccentrically loaded columns The CFRP rupture of eccentrically loaded columns did not simultaneously occur when these columns achieved the ultimate load, as shown in Figure 3. Therefore, the CFRP strain distributions of these specimens were obtained at the ultimate load and at CFRP rupture. The CFRP strain was the highest at the extreme compression fibre, whereas the smallest strain arose at the extreme tension fibre of the columns. The CFRP strain decreased gradually from the extreme compression fibre to the extreme tension fibre, as shown in Figure 4. Figure 4 also shows the strain on the overlap zone compared with the hoop strain distribution over the columns' circumference. The CFRP strains within the overlap zone were always lower than those outside the overlap zone. The strains at the extreme compression fibre were 5.3 and 3.3 times higher than those at the extreme tension fibre when Specimen C80-25 achieved the ultimate load and the CFRP ruptured, respectively. Similarly, these ratios were 10.8 and 9.3 respectively for Specimens C80-50. The results demonstrated that the disproportion between the CFRP strain at the extreme compression fibre and at the extreme tension fibre increased with increasing load eccentricity. at the ultimate load at rupture C80-50 Figure 3. Axial load- CFRP strain diagrams of specimens subjected eccentric loading Figure 4. CFRP hoop strain distribution. Table 3. CFRP hoop strain of the columns at extreme compression fibre at rupture Eccentricity CFRP hoop strain of the columns C40 group C80 group Concentric loading 1.29% 1.05% 25 mm Eccentric loading 1.13% 1.23% 50 mm Eccentric loading 1.22% 1.25% The strain efficiency factor of CFRP under eccentric load is defined as the ratio of CFRP strain at the extreme compression fibre at the ultimate load to the rupture strain of CFRP from flat coupon tests. The higher the load

eccentricity, the lower strain efficiency factor was obtained. For example, the strain efficiency factors were 0.67, 0.4 and 0.26 for the columns under concentric loading, 25 mm eccentric loading and 50 mm eccentric loading. These values were calculated from the average values of the FRP strain efficiency factor from Group C40 and C80. Table 3 shows the result of the CFRP rupture strains in the hoop direction at the extreme compression fibre, which was quite similar to the value of CFRP rupture strain under concentric loading. It is believed that CFRP ruptured when the maximum CFRP hoop strain achieved about 0.68% of the ultimate strain of CFRP from flat coupon tests. Influence of internal transverse steel reinforcement To further investigate the influence of transverse steel reinforcement on FRP-confined columns, four specimens were taken from the study by Hadi et al. (2013) and compared with the relevant specimens in this study. The specimens had the same geometry and FRP-confinement except that the compressive strength of concrete in Hadi et al. (2013) was 27 MPa. The same amount of longitudinal reinforcement was maintained but the ties used by Hadi et al. (2013) had 120 mm spacing compared with 60 mm spacing in current study. Both specimens under concentric and eccentric loading with 25 mm eccentricity are compared. Details of the specimens are given in Table. 4. Table.4 Experimental results of specimens with different transverse steel reinforcement Specimens Tie spacing Yield Load Corresponding Ultimate Corresponding (mm) (kn) Deflection (mm) Load (kn) Deflection (mm) Ductility b R-0 60 894 4.28 919 4.93 1.39 N-0 a 120 707 1.31 717 1.46 1.41 C40-0 60 2140 2.82 3343 13.72 4.96 CF-0 a 120 1478 2.01 2907 13.35 6.98 R-25 60 615 2.84 633 3.13 1.15 N-25 a 120 414 0.96 427 1.08 1.33 C40-25 60 1421 3.43 1519 6.03 3.97 CF-25 a 120 1011 1.08 1170 6.12 5.11 a Denotes specimens taken from Hadi et al. (2013). b Ductility is calculated as the ratio of the deflection at 85% post-peak load to the deflection at yield load. The normalised stress-deflection diagrams for specimens under concentric load and 25 mm eccentric load are shown in Figure 5. The normalised stress was calculated as the ratio of cross-sectional stress to the compressive strength of unconfined concrete. The cross-sectional stress was calculated as the axial force divided by the gross cross-sectional area. It is evident that the specimens with different transverse steel reinforcement behaved in a similar manner. Specimens with smaller tie spacing achieved similar normalised yield and ultimate stress as shown in Table 4. This is probably due to the fact that confining pressure provided by transverse steel reinforcement is much smaller than that by FRP (only between 1% to 7% of the confining pressure provided by FRP). In addition, improvement in ductility was not witnessed for columns with smaller tie spacing. This is mainly due to the instrumentation-related errors. Further experimental investigations on columns with various tie spacing are required to evaluate the effect of tie spacing on FRP-confined columns Normalised Stress Axial Deflection (mm) Axial Deflection (mm) (a) Concentric Load, e=0 (b) Eccentric Load, e=25 Figure 5. Specimens with different transverse steel reinforcement

CONCLUSIONS Based on test observation in the experimental program, the following conclusions can be drawn: The CFRP strain efficiency factors, which were calculated at the ultimate loads, were 0.67, 0.4 and 0.26 for these specimens under concentric loading, 25 mm eccentric loading and 50 mm eccentric loading, respectively. The CFRP rupture strains at the compression tension fibre under eccentric loading were quite similar to the value of CFRP rupture strain under concentric loading. The disproportion between the CFRP strain at the extreme compression fibre and at the extreme tension fibre increased with increasing load eccentricity. The difference in transverse reinforcement in FRP confined reinforced concrete columns is negligible in terms of normalised compressive stress, which indicates that the contribution of steel ties is marginal compared to the contribution of FRP. In addition, the ductility of the columns is not affected by the amount of transverse steel reinforcement based on this study but further investigation is encouraged. ACKNOWLEDGMENTS The authors acknowledge the technical assistance of Messers Alan Grant, Fernando Escribano, Cameron Neilson, Ritchie McLean and Colin Devenish. The authors also thank Mr. Eric Lume for his advice on casting HSC. The first author would like to thank the scholarship of University of Da Nang and the University of Wollongong. The second author would acknowledge the University of Wollongong for funding his studies. The third author would also like to acknowledge the Vietnamese Government and the University of Wollongong for the support of full PhD scholarship. REFERENCES Australian Standard (AS) 3600 (2009). Concrete structures, Standards Australia. Australian Standard (AS) 1391 (2007). Metallic materials Tensile testing at ambient temperature. Standards Australia. ASTM D3039 (2008). Standard test methods for tensile properties of polymer matrix composite materials, ASTM International. Hadi, M., Pham, T., and Lei, X. (2013)."New Method of Strengthening Reinforced Concrete Square Columns by Circularizing and Wrapping with Fibre-Reinforced Polymer or Steel Straps."Journal of Composites for Construction, 17(2), 229-238. Hadi, M. N. S., and Widiarsa, I. B. R. (2012). "Axial and Flexural Performance of Square RC Columns Wrapped with CFRP under Eccentric Loading." Journal of Composites for Construction, 16(6), 640-649. Lam, L., and Teng, J. G. (2003). "Design-oriented stress-strain model for FRP-confined concrete."construction and Building Materials, 17(6-7), 471-489. Pessiki, S., Harries, K. A., Kestner, J. T., Sause, R., and Ricles, J. M. (2001). "Axial behaviour of reinforced concrete columns confined with FRP jackets." Journal of Composites for Construction, 5(4), 237-245. Pellegrino, C & Modena, C. (2010). Analytical model for FRP confinement of concrete columns with and without internal steel reinforcement, Journal of Composites for Construction, 14(6), 693-705.