Gas Generators Parker Balston Zero Air Generators Ultra High Purity Hydrogen Generators for Fuel and Carrier Gas Hydrogen Generators for Fuel Gas Self Contained Membrane Nitrogen Generators Membrane Nitrogen Generators Ultra High Purity Nitrogen Generators Makeup Gas Generators FID Gas Stations Halogenated Hydrocarbon Scrubber Membrane Air Dryers 400 400 401 401 402 402 403 404 404 405 405 398
Featured Products Zero Air Generators Hydrogen Generators 400 402 401 for Fuel Gas Self Contained Membrane Nitrogen Generators Notes from the Support Desk In-house gas generators provide a number of significant benefits to the laboratory, including a dramatic improvement in safety, an increase in convenience, and a lower cost. INSTRUMENT GAS REQUIREMENTS GAS PURITY REQUIREMENTS FLOW RATES GENERATOR RECOMMENDATION Atmospheric Pressure Ionization (API-MS) Gas Chromatograph (GC) GC-FID Air for Nebulizer Gas Nitrogen for Curtain, Sheath, and Shield gas Air for Nebulizer Gas Nitrogen for Curtain, Sheath, and Shield gas Clean, Dry, Hydrocarbon-free <30 LPM Zero Air Generator (HPZA-30000) 99% or higher <20 LPM Nitrogen Generator (N2-14, N2-22, N2-35, NitroFlowLab) Zero Air as Flame Support Air Clean, Hydrocarbon-free 150 600 cc/min Zero Air Generator (HPZA-3500) Hydrogen as Flame Fuel Gas Ultra High Purity 30 40 cc/min Hydrogen Generator (H2PEM-260) Hydrogen as Capillary Carrier Gas Ultra High Purity Varies Hydrogen Generator (H2PD-300) Nitrogen as Packed Carrier Gas Ultra High Purity, Zero Grade Varies UHP Nitrogen Generator (UHPN2-1100) Nitrogen as Make up Gas Ultra High Purity, Zero Grade <100 cc/min UHP Nitrogen Generator (UHPN2-1100) GC-FPD Zero Air as Flame Support Air Clean, Hydrocarbon-free <200 cc/min Zero Air Generator (HPZA-3500) Hydrogen as Flame Fuel Gas Ultra High Purity 50 70 cc/min Hydrogen Generator (H2PEM-260) Hydrogen as Capillary Carrier Gas Ultra High Purity Varies Hydrogen Generator (H2-1200) Nitrogen as Packed Carrier Gas Ultra High Purity Varies UHP Nitrogen Generator (UHPN2-1100) GC-NPD Zero Air to Rubidium/Thermonic Bead Dry, Clean, Hydrocarbon-Free 60 200 cc/min Zero Air Generator (HPZA-3500) Hydrogen as Detector Support Gas Ultra High Purity <10 cc/min Hydrogen Generator (H2PEM-100) Hydrogen as Capillary Carrier Gas Ultra High Purity Varies Hydrogen Generator (Palladium) (H2PD-300) Nitrogen as Packed Carrier Gas Ultra High Purity Varies UHP Nitrogen Generator (UHPN2-1100) GC-ECD Nitrogen as Carrier Gas Ultra High Purity, Zero Grade Varies UHP Nitrogen Generator (UHPN2-1100) Nitrogen as Make up Gas Ultra High Purity, Zero Grade <100 cc/min UHP Nitrogen Generator (UHPN2-1100) GC-ELCD, HALL Hydrogen as Reaction Gas Ultra High Purity 70 200 cc/min Hydrogen Generator (H2PD-300) GC-TCD Hydrogen as Carrier & Reference Gas Ultra High Purity Varies Hydrogen Generator (H2PD-300) LC/MS Nitrogen as a Curtain Gas LC/MS Grade 3 60 Ipm Nitrogen Generator (N2-14, N2-14ANA, NitroFlowLab) (N2-35, N2-35ANA) ICP Spectrometer Nitrogen as Optic/Camera Purge Ultra High Purity <1 5 Ipm Nitrogen Generator (76-97NA, 76-98NA) Gas Generators 800.822.5242 952.431.6000 www.chromtech.com 399
GAS GENERATORS Parker Balston Parker Balston Zero Air Generators Produce UHP zero air from house compressed air (<0.05 PPM THC) Eliminate inconvenient and dangerous zero air cylinders from the lab Qualitative smart-display provides operational status at a glance Recommended and used by many GC and column manufacturers Silent operation and minimal operator attention required Parker Balston s Zero Air Generators are systems manufactured with state-of-the-art, highly reliable components engineered for easy installation, operation, and long term performance. Parker Balston s Zero Air Generators eliminate all the inconveniences and costs of cylinder gas supplies and dependence on outside vendors. Uncontrollable vendor price increases, contract negotiations, long term commitments and tank rentals are no longer a concern; Parker Balston Zero Air Generators offer long term cost stability. There is no need to use valuable laboratory floor space to store excessive reserves to protect yourself from late deliveries, transportation interruptions, or periods of tight supplies. With a Parker Balston Zero Air Generator, you control your supply. NUMBER OF FIDs Up to 2 Up to 8 Up to 16 Up to 40 Up to 66 PART NO 75-83NA HPZA-3500 HPZA-7000 HPZA-18000 HPZA-30000 PARKER BALSTON ZERO AIR GENERATORS SPECIFICATIONS OUTLET HYDROCARBON CONCENTRATION (AS METHANE) 75-83NA, HPZA-30000: < 0.1 ppm HPZA-3500, HPZA-7000, HPZA-18000: < 0.05 ppm MIN/MAX INLET AIR MAX INLET HYDROCARBON CONCENTRATION (AS METHANE) 40 PSI/125 PSI 100 ppm 4 PSI MAX INLET AIR TEMPERATURE INLET/OUTLET PORTS DIMENSIONS (W X D X H) SHIPPING WEIGHT 78 F (26 C) 1/4" NPT (female) 75-83NA: 10" x 3" x 12" (25 x 8 x 30 cm) HPZA-3500, HPZA-7000, HPZA-18000, HPZA-3000: 1" x 13" x 16" (27 x 34 x 42 cm) DROP AT MAX FLOW RATE 75-83NA: 7 lbs (3 kg) HPZA-3500, HPZA-7000, HPZA-18000, HPZA-3000: 41 lbs (19 kg) PARKER BALSTON ZERO AIR GENERATORS FLOW RATE 1 LPM 3.5 LPM 7 LPM 18 LPM 30 LPM PART NO 75-83NA HPZA-3500 HPZA-7000 HPZA-18000 HPZA-30000 MAINTENANCE KIT MK7583 MK7840 MK7840 MK7840 MK7840 INSTALLATION KIT IK76803 IK76803 IK76803 IK76803 IK76803 400 Chrom Tech your chromatography specialists
Parker Balston GAS GENERATORS Parker Balston Ultra High Purity Hydrogen Generators for Fuel and Carrier Gas Cascading feature connects up to 32 hydrogen generators together to supply a large number of instruments Includes 3 year cell warranty Simple maintenance Eliminates cylinders Safe produces only as much gas as you need Automatic water feed for continuous operation Remote PC monitoring features PARKER BALSTON H2PEMPD SPECIFICATIONS HYDROGEN PURITY OXYGEN CONTENT WATER CONTENT POWER 99.99999+% < 0.01 ppm <1 ppm 100 230 VAC, 50/60 Hz MAX OUTLET OUTLET CONNECTION DIMENSIONS SHIPPING WEIGHT 100 or 175 PSI 1/4" compression 17.1" x 13.5" x 21" 60 lbs TECH TIP Delivery pressure of up to 175 PSI; ideal for high speed and fast GC applications. PARKER BALSTON H2PEMPD HYDROGEN GENERATORS FLOW RATE 510 cc/min 650 cc/min 850 cc/min 1100 cc/min 1300 cc/min Max Outlet Pressure H2PEMPD-510-100 H2PEMPD-650-100 H2PEMPD-850-100 H2PEMPD-1100-100 H2PEMPD-1300-100 to 100 PSI (6.8 bar) Max Outlet Pressure H2PEMPD-510-175 H2PEMPD-650-175 H2PEMPD-850-175 H2PEMPD-1100-175 H2PEMPD-1300-175 to 175 PSI (11.9 bar) 6 MONTH SERVICE KIT 1 MKH2PEMPD-6M 24 MONTH SERVICE KIT 2 MKH2PEMPD-24M Certified for laboratory use by CSA, IEC 1010, and CE Mark 1) Includes Deionizer cartridge, 100 µm Water filter, (2) Environmental filters, and Filter replacement tool 2) Includes Deionizer cartridge, 100 µm Water filter, (2) Environmental filters, Filter replacement tool, Tube clamp, Water pump, and (2) Fan guards Parker Balston Hydrogen Generators for Fuel Gas Ideal for fuel gas, up to 14 FID s Includes 2 year cell warranty Eliminates dangerous and expensive hydrogen gas cylinders Exclusive water management system and control circuitry maximize uptime Unique display lighting changes color for easy status checks Remote control and remote monitoring capable Compact and reliable only one square foot of bench space required No liquid caustics PARKER BALSTON H2PEM SPECIFICATIONS HYDROGEN PURITY OUTLET PORT DELIVERY 99.9995+% 1/8" compression 5 100 PSI ± 0.5 PSI POWER DIMENSIONS SHIPPING WEIGHT 100 230 VAC 17.1" x 13.5" x 18" 59 lb PARKER BALSTON H2PEM GENERATORS FLOW RATE 100 cc/min 165 cc/min 260 cc/min 510 cc/min PART NO H2PEM-100 H2PEM-165 H2PEM-260 H2PEM-510 DESICCANT CARTRIDGE (1/EA) MKH2PEM-D 6 MONTH SERVICE KIT 1 MKH2PEM-6M 24 MONTH SERVICE KIT 2 MKH2PEM-24M 1) Includes Deionizer Cartridge, Water Filter, and (3) Environmental Filters 2) Includes Deionizer Cartridge, Water Filter, (3) Environmental Filters, Float, Water Pump, Desiccant Cartridge, and Service Reset Dongle Authorized Distributor 800.822.5242 952.431.6000 www.chromtech.com 401
GAS GENERATORS Parker Balston Parker Balston LC/MS NitroFlow Self Contained Membrane Nitrogen Generators 3 year limited compressor warranty Nearly silent operation; operates at less than 49 db(a) PARKER BALSTON NITROFLOW 60/NITROFLOW 60D SPECIFICATIONS NITROGEN HYDROCARBON PHTHALATE FREE ATMOSPHERIC DEW POINT Up to 60 LPM Yes Yes -58 F OUTLET PORT MAX OUTLET MIN/MAX AMBIENT TEMP DIMENSIONS Female 1/4" NPT 100 PSI 50 F/95 F 43" x 21" x 34" SHIPPING WEIGHT DRY AIR FLOW DRY AIR DEW POINT POWER 643 lbs 5 SLPM (60D only) -40 F (-40 C) (60D only) 195-254 VAC, 60 Hz, 1 Phase, 14A, 230 VAC, 50 Hz, 1 Phase, 13A 2 year compressor warranty Includes state-of-the-art, oil-less compressors PARKER BALSTON NITROFLOW LAB SPECIFICATIONS NITROGEN HYDROCARBON FREE PHTHALATE FREE ATMOSPHERIC DEW POINT Up to 30 LPM <2 ppm (excluding methane) Yes -58 F MAX OUTLET OUTLET PORT SHIPPING WEIGHT MIN/MAX AMBIENT TEMP 116 PSI Female 1/4" NPT 204 lbs 50 F/95 F DIMENSIONS POWER 28" x 12" x 35" 120 VAC, 60 Hz, 20 Amp PARKER BALSTON NITROFLOW GENERATORS DESCRIPTION PART NO Nitroflow Generator, 30 LPM NITROFLOW Nitroflow Generator, 60 LPM NITROFLOW60 Nitroflow Generator, 60 LPM w/dryer NITROFLOW60D Parker Balston Membrane Nitrogen Generators Recommended and used by all major LC/MS manufacturers PARKER BALSTON MEMBRANE NITROGEN SPECIFICATIONS SUSPENDED LIQUIDS PARTICLES > 0.01 µm ATMOSPHERIC DEW POINT NITROGEN PURITY None None 95.0% 99.5% 95.0% 99.5% PHTHALATE FREE HYDROCARBON-FREE MAX INLET AIR TEMP AMBIENT TEMP Yes Yes 110 F 68 72 F COMMERCIALLY STERILE MIN/MAX OPERATING MAX PRESS DROP @99% N2 PURITY, 125 PSI POWER (ANA MODELS ONLY) Yes 60/145 PSI 10 PSI 120 VAC, 60 Hz, 25W 402 The purity level of the nitrogen stream is defined by the user, for the application, and may range from 95% to 99.5%. Chrom Tech your chromatography specialists PARKER BALSTON MEMBRANE NITROGEN GENERATORS NITROGEN FLOW RATE* @ 100 PSI, 99% @ 90 PSI, 99% @ 80 PSI, 99% SHIPPING WEIGHT DIMENSIONS PORTS PART NO 4 LPM 4 LPM 3 LPM 42.5 lbs 16" x 11" x 13" 1/4" NPT N2-04 13 LPM 11 LPM 10 LPM 80 lbs 52" x 18" x 16" 1/4" NPT N2-14 20 LPM 18 LPM 15 LPM 80 lbs 52" x 18" x 16" 1/4" NPT N2-22 30 LPM 27 LPM 23 LPM 90 lbs 52" x 18" x 16" 1/4" NPT N2-35 53 LPM 44 LPM 35 LPM 250 lbs 67" x 24" x 20" 1/2" NPT N2-45 79 LPM 66 LPM 53 LPM 250 lbs 67" x 24" x 20" 1/2" NPT N2-80 106 LPM 89 LPM 71 LPM 250 lbs 67" x 24" x 20" 1/2" NPT N2-135 *Flow rate is dependent on incoming air pressure and the purity level of the nitrogen stream selected. Please call for a quote for Preventative Maintenance or Extended Warranty options
Parker Balston GAS GENERATORS Parker Balston Ultra High Purity Nitrogen Generators Produce a continuous supply of high purity nitrogen gas from existing compressed air Eliminate the need for costly dangerous, inconvenient nitrogen cylinders Compact design frees up valuable laboratory floor space Offers long term cost stability uncontrollable vendor price increases, contract negotiations, long term commitments and tank rentals are no longer a concern Ideal for carrier gas applications PARKER BALSTON UHPN2-1100 SPECIFICATIONS NITROGEN PURITY CO CONCENTRATION CO 2 CONCENTRATION O 2 CONCENTRATION 99.9999% < 1 ppm < 1 ppm < 1 ppm H 2 0 CONCENTRATION HYDROCARBON CONCENTRATION ARGON CONCENTRATION MIN/MAX INLET < 1 ppm < 0.1 ppm 0.9% 60 PSI/125 PSI REC. INLET TEMP AMBIENT OPERATING TEMP MAX AIR CONSUMPTION INLET CONNECTION 78 F (25 C) 60 F 100 F (16 C 38 C) 42 LPM (1.5 scfm) 1/4" NPT (female) OUTLET CONNECTION POWER DIMENSIONS SHIPPING WEIGHT 1/8" compression 120 VAC/60 Hz 12" x 16" d x 35" h 110 lbs (50 kg) INLET AIR (PSI) MAX OUTLET FLOW (cc/min) 125 1100 85 110 1000 75 100 900 65 90 800 60 80 700 50 70 600 45 60 500 35 MAX OUTLET (PSI) PARKER BALSTON ULTRA HIGH PURITY NITROGEN GENERATORS DESCRIPTION UHP NITROGEN Generator PART NO UHPN2-1100 TECH TIP Parker Balston Extended Support Programs Parker Balston plans range from the standard Depot class of support to the exclusive Express class of support. Both types of plans are convenient and are designed to match your needs and budget. Parker Balston Extended Support Plans are smart to select when you depend upon high performance analytical equipment. Our exclusive Express support program offers the piece-of-mind of a new or like new replacement generator arriving at your door the very next business morning. PARKER BALSTON EXTENDED SUPPORT PROGRAMS Next day delivery of new or like new temporary replacement unit EXPRESS (EN2) DEPOT (DN2) N/A Extends warranty coverage to 24 months Covers replacement parts for repair Covers labor charges for repair Covers packaging material for repair Covers freight charges for repair Authorized Distributor 800.822.5242 952.431.6000 www.chromtech.com 403
GAS GENERATORS Parker Balston Parker Balston Makeup Gas Generators & FID Gas Stations Makeup Gas Generator Produces Makeup Grade Nitrogen Ideal for up to 5 6 FIDs In addition to nitrogen, Model MGG-2500NA also produces 2500 cc/min zero air Eliminates dangerous and costly helium or nitrogen cylinders from the laboratory Improves flame shape within the FID detector and maximizes sensitivity Recommended and used by many GC and column manufacturers Typical payback period of less than one year Silent operation and minimal operator attention required PARKER BALSTON MAKEUP GAS GENERATOR SPECIFICATIONS NITROGEN PURITY ZERO AIR PURITY 99.9999+% (with respect to hydrocarbons) 99+% (with respect to oxygen) MGG-2500NA Only : <0.05 ppm (total hydrocarbon as methane) NITROGEN OUTLET ZERO AIR OUTLET CERTIFICATIONS POWER 60 100 PSI MGG-2500NA Only: 60 100 PSI IEC 1010-1; CSA 1010; UL 3101; CE Mark 120 VAC, 60 Hz INLET PORT OUTLET PORTS DIMENSIONS SHIPPING WEIGHT 1/4" NPT (female) 1/4" NPT (female) 7" x 26" x 16.5" (18 x 66 x 42 cm) 60 lbs / 27 kg PARKER BALSTON MAKEUP GAS GENERATORS Max Nitrogen Flow Rate Max Zero Air Flow Rate 400 cc/min N/A 400 cc/min 2500 cc/min PART NO MGG-400NA MGG-2500NA ANNUAL MAINTENANCE KIT MKMGG2500-12 MKMGG2500-12 FID Gas Station Produces UHP Zero Air & Hydrogen Gas Produces UHP zero air from house compressed air and 99.9995% pure hydrogen gas Eliminate inconvenient and dangerous zero air and hydrogen cylinders Increases accuracy of analysis and reduces the cleaning requirement of the detector Recommended and used by many GC and column manufacturers Payback period of typically less than one year Automatic water fill Silent operation and minimal operator attention required PARKER BALSTON FID GAS STATION SPECIFICATIONS ZERO AIR PURITY ZERO AIR OUTLET HYDROGEN PURITY HYDROGEN OUTLET <0.1 ppm (total hydrocarbon as methane) 40 125 PSI 99.9995% 60 PSI CERTIFICATIONS POWER INLET PORT OUTLET PORTS IEC 1010-1; CSA 1010; UL 3101; CE Mark 120 VAC, 60 Hz 1/4" NPT (female) compressed air supply 1/8" Compression DIMENSIONS SHIPPING WEIGHT 10.5" x 17" x 16.5" (27 x 43 x 42 cm) 53 lbs / 24 kg PARKER BALSTON FID GAS GENERATORS MAX NITROGEN FLOW RATE MAX HYDROGEN FLOW RATE 90 cc/min 1,000 cc/min 250 cc/min 2500 cc/min PART NO FID-1000NA FID-2500NA INSTALLATION SERVICE FID-1000-INST FID-2500-INST ANNUAL MAINTENANCE KIT MKFID1000 MKFID1000 404 Chrom Tech your chromatography specialists
Parker Balston GAS GENERATORS Parker Balston Halogenated Hydrocarbon Scrubber Ideal for removing halogenated hydrocarbons from compressed air Extended-life adsorbent requiring minimal maintenance Protects equipment from chlorinated solvent vapors Purified bulk inert non-corrosive gases Parker Balston Halogenated Hydrocarbon Scrubbers effectively remove halogenated hydrocarbons from an existing compressed air supply. The scrubber can be used with any Parker Balston Zero Air Generator or UHP Nitrogen Generator if the compressed air supply contained halogenated hydrocarbons. PARKER BALSTON 76080 HALOGENATED HYDROCARBON SCRUBBER SPECIFICATIONS MIN/MAX INLET/OUTLET PORTS CHANGE FREQUENCY AT 17 LPM 60 PSI 125 PSI 1/4" NPT (female) 18 Months DIMENSIONS (h x w x d) SHIPPING WEIGHT 41" x 15" x 8" 29 lbs PARKER BALSTON HALOGENATED HYDROCARBON SCRUBBER DESCRIPTION PART NO Halogenated hydrocarbon scrubber 76080 Parker Balston Laboratory Membrane Air Dryers Low dewpoint instrument air prevents analytical instrument contamination Dry air for hazardous areas No electricity required low operating costs No refrigerants or freons environmentally sound Explosion proof No moving parts or motors silent operation PARKER BALSTON MEMBRANE AIR DRYER SPECIFICATIONS MIN/MAX INLET AIR TEMP RECOMMENDED OPERATING TEMP RANGE MIN/MAX INLET -40 F/140 F 60 F 100 F 60 PSI/150 PSI < 4 PSI MAX DROP WALL MOUNTABLE INLET/OUTLET PORT SIZE SHIPPING WEIGHT DIMENSIONS (w x h x d) Yes 64-01, 64-02: 1/4" NPT (female) 64-10: 1/2" NPT (female) 64-01: 9 lbs (4 kg) 64-02: 10 lbs (5 kg) 64-10: 18 lbs (9 kg) 64-01: 6" x 22" x 5" 64-02: 6" x 23" x 5" 64-10: 6" x 37" x 5" PARKER BALSTON MEMBRANE AIR DRYERS MAX FLOW RATE AT -40 F DEWPOINT MAX FLOW RATE AT 32 F DEWPOINT 2 LPM 71 LPM 57 LPM 142 LPM 283 LPM 708 LPM PART NO 64-01 64-02 64-10 ANNUAL MAINTENANCE KIT MK7601 MK7601 MK7610 Authorized Distributor 800.822.5242 952.431.6000 www.chromtech.com 405