Power control of a photovoltaic system connected to a distribution frid in Vietnam

Similar documents
Optimization with Energy Management of PV Battery Stand-Alone Systems over Life Cycle

How Resilient Is Your Organisation? An Introduction to the Resilience Analysis Grid (RAG)

Conception of a new engineering curriculum in smart buildings

Environmental Impact of PV Systems: Effects of Energy Sources Used in Production of Solar Panels

Comparison of lead concentration in surface soil by induced coupled plasma/optical emission spectrometry and X-ray fluorescence

Impact of cutting fluids on surface topography and integrity in flat grinding

Performance evaluation of centralized maintenance workshop by using Queuing Networks

PhD Dissertation Defense Presentation

Custom Power Interfaces for Renewable Energy Sources

Densification superficielle de matériaux poreux par choc laser

Power Flow Control Scheme for Wind Energy Conversion System

Design and Simulink of Intelligent Solar Energy Improvement with PV Module

Distributed Maximum Power Point Tracking in Solar Photovoltaic Applications Using Multiphase Switching Converters

New experimental method for measuring the energy efficiency of tyres in real condition on tractors

Modeling and simulation of grid-connected photovoltaic generation system

Fatigue of High Purity Copper Wire

Occupational accidents in Belgian industry in restructuring contexts

Anne Peretz. To cite this version: HAL Id: halshs

Modeling and Simulation of Utility Interfaced PV/Hydro Hybrid Electric Power System P. V. V. Rama Rao, B. Kali Prasanna, Y. T. R.

Facility Layout Planning of Central Kitchen in Food Service Industry: Application to the Real-Scale Problem

DISLOCATION RELAXATION IN HIGH PURITY POLYCRYSTALLINE ALUMINUM AT MEGAHERTZ FREQUENCIES

Designing and Implementing a Framework for Process-Oriented Logistics-Costs Measurement in an Automotive-Supplier Group

Balanced Scorecard leading indicators to monitor performance variability in OHS management systems.

Aeration control in a full-scale activated sludge wastewater treatment plant: impact on performances, energy consumption and N2O emission

Integrating Aspects of Supply Chain Design into the Global Sourcing Process Insights from the Automotive Industry

Value-Based Design for Gamifying Daily Activities

Can combining web and mobile communication channels reveal concealed customer value?

Effects of temperature on monotonic and fatigue properties of carbon fibre epoxy cross ply laminates

Micro-generation using LMS Imagine.Lab AMESim

Environmental impact for offshore wind farms: Geolocalized Life Cycle Assessment (LCA) approach

Erosion wear behaviour and model of abradable seal coating

ANALYSIS OF THE BEHAVIOR FOR REACTIVE POWER COMPENSATION USING SVC CONTROLLED HYBRID SOLAR/WIND POWER GENERATING SYSTEMS

H AND REPETITIVE CONTROL

Towards a Modeling Framework for Service-Oriented Digital Ecosystems

Separation of Decision Modeling from Business Process Modeling Using New Decision Model and Notation (DMN) for Automating Operational Decision-Making

Synergic effects of activation routes of ground granulated blast-furnace slag (GGBS) used in the precast industry

Averaging techniques for single-trial analysis of oddball event-related potentials

Design of Grid Connected PV System Using Pvsyst

A new emerging rural world. An overview of rural change in Africa, Atlas for the Nepad Rural Futures programme,

Innovation Management in European Projects

An Outlook for the Non-Compliance Mechanism of the Kyoto Protocol on Climate Change

In-Situ Study of Thermal Comfort Enhancement in a Renovated Building Equipped with Phase Change Material Wallboard

Facade sound isolation: a few questions

Modeling and Simulation for an 8 kw Three-Phase Grid-Connected Photo-Voltaic Power System

Agricultural biodiversity, knowledge systems and policy decisions

Switch Solar. Praveen Raj. [20 KWp Solar Power Plant Technical Proposal] Noble Hospital Chennai, Tamil Nadu.

PV Fluctuation Balancing Using Hydrogen Storage a Smoothing Method for Integration of PV Generation into the Utility Grid

OPTIMIZATION STRATEGY OF REACTIVE POWER COMPENSATION IN GI - PV SYSTEM

ELLIPSOMETRY OF NICKEL-OXIDES AND -HYDROXIDES IN ALKALINE ELECTROLYTE

Power quality improvement by using STATCOM control scheme in wind energy generation interface to grid

ATOM-PROBE ANALYSIS OF ZIRCALOY

The Effect of Nitrogen on Martensite Formation in a Cr-Mn-Ni Stainless Steel

Impacts of the Decentralized Wind Energy Resources on the Grid

Wind Energy Conversion Using Shunt Active Power Filter

On the relation between the Luders deformation and grain boundary structure in aluminium alloy

Smarter Round Robin Scheduling Algorithm for Cloud Computing and Big Data

AR No. # - Install Photovoltaic Array

Implementation of Novel Hybrid Wind Solar Energy Conversion System

Hybrid Systems Introduction

Specification and Configuration of Customized Complex Products

Design Installation and Testing of 1.6 kwp GPV System

LOW CARBON AND SILICON STEEL QUADRUPOLE MAGNETS

Growth and characterization of ferrite film prepared by pulsed laser deposition

New method to evaluate the heat storage density in latent heat storage for arbitrary temperatureranges

This is an electronic reprint of the original article. This reprint may differ from the original in pagination and typographic detail.

Incremental conductance (IncCond) algorithm for Maximum Power Operating Point (MPOP) of Photo-Voltaic (PV) power generation system

Crack nucleation and propagation in highly heterogeneous microstructure models based on X-ray CT images of real materials

Exploring the Impact of ICT in CPFR: A Case Study of an APS System in a Norwegian Pharmacy Supply Chain

Details of the A*STAR funded MEMS project are available at

LASER CLADDING BY POWDER INJECTION : OPTIMIZATION OF THE PROCESSING CONDITIONS

Silicon carbonitrides - A novel class of materials

Performance Analysis of grid connected PV Wind Hybrid Power System

The Effect of the Volt/Var Control of Photovoltaic Systems on the Time-Series Steady-State Analysis of a Distribution Network

Capability Profile for Enterprise Application Integration

Natural ventilation and acoustic comfort

Simulation of Solar Generation System for MPPT

Journal of Asian Scientific Research

Monitoring of 20 kwp photovoltaic system

INTEGRATED ELECTRIFICATION SOLUTION FOR REMOTE ISLANDS BASED ON WIND-PV HYBRID SYSTEM

ACTIVITY 6: Series and Parallel Wiring

ENERGY HARVESTING. Energy Conversion Systems. Solar, Wind, and Ocean. Omer C. Onar. Alireza Khaligti

Energy Processing for Smart Grid (4.4)

Atom-probe study Ti Al based alloy

Compatibility of the French white certificate program to fulfil the objective of energy savings claimed by the Energy Service Directive

The State of the Art of Generators for Wind Energy Conversion Systems

A Model Integration Framework for Assessing Integrated Landscape Management Strategies

Performance loss rates of grid-connected photovoltaic technologies in warm climates

J. Electrical Systems 11-2 (2015): Regular paper

ABSORPTION OF THE INFRARED RADIATION IN LASER SURFACE TREATMENTS OF FERROUS ALLOYS

THE TEMPERATURE DEPENDENCE OF THE ANISOTROPY FIELD IN R2Fe14B COMPOUNDS (R = Y, La, Ce, Pr, Nd, Gd, Ho, Lu)

Grid-Connection Single-Stage Photovoltaic Inverter System with Double-Linear-Approximation MPPT

IMPACT OF SMALL PRODUCERS ON POWER QUALITY IN DISTRIBUTION GRIDS BASED ON ELEKTRILEVI OÜ GRID

Local Government Challenges in post apartheid South Africa

ANALYSIS OF BERKEN ENERGY THERMOELECTRIC TECHNOLOGY

Perishable Inventory Challenges

Testing and Evaluation of Dynamic Energy Simulations for the development of an Intelligent Management of Energy for the ADREAM Smart Building

Ductility of Ultra High Purity Copper

High School Lesson Plan: Photovoltaic Power Potential

NON-CONVENTIONAL SOURCE OF ENERGY FOR SUSTAINABLE GROWTH OF RURAL AND URBAN AREAS

Transcription:

Power control of a photovoltaic system connected to a distribution frid in Vietnam Xuan Truong Nguyen, Dinh Quang Nguyen, Tung Tran To cite this version: Xuan Truong Nguyen, Dinh Quang Nguyen, Tung Tran. Power control of a photovoltaic system connected to a distribution frid in Vietnam. Vietnam Academy of Science and Technology Journal of Science and Technology, 2015, pp.331-336. <hal-01166546> HA Id: hal-01166546 https://hal.archives-ouvertes.fr/hal-01166546 Submitted on 23 Jun 2015 HA is a multi-disciplinary open access archive for the deposit and dissemination of scientific research documents, whether they are published or not. The documents may come from teaching and research institutions in France or abroad, or from public or private research centers. archive ouverte pluridisciplinaire HA, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des établissements d enseignement et de recherche français ou étrangers, des laboratoires publics ou privés.

Journal of Science and Technology 53 (3A) (2015) POWER CONTRO OF A PHOTOVOTAIC SYSTEM CONNECTED TO A DISTRIBUTION GRID IN VIETNAM Nguyen Xuan Truong 1,*, Nguyen Dinh Quang 1, 2, Tran Tung 1 1 Clean energy and sustainable development laboratory, Renewable energies department, University of Science and Technology of Hanoi 2 Institute of Energy Science, Vietnam Academy of Science and Technology * Email: nguyen-xuan.truong@usth.edu.vn Received: May 10, 2015; Accepted for Publication: June 15, 2015 ABSTRACT The demand for electrical energy is increasing in Vietnam in recent decades; which has motivated the use of renewable energy sources (RES). Among them, Photovoltaic (PV) energy is becoming a promising energy sources because of their advantages. The connection and use of PV in distribution grid in Vietnam should be in line with the framework of sustainable energy development worldwide. The different techniques of modeling and control of grid connected PV system with objective to help intensive penetration of PV electricity into grid have been proposed so far in different literatures. The current methodologies for optimizing of generation power of PV system are not completely efficient. Therefore many researches are required for overall configuration of the grid connected PV system, the Maximum Power Point Tracking algorithm, the synchronization of the inverter. This paper presents a control technique of the PV generation power by shift of phase angle of the inverter output voltage and grid voltage. In order to synchronize an alternative current output of the PV system s inverter into grid, the proposed method has been described, simulated in MATAB/Simulink. The work helps to give a study results about interconnection standard, power generation optimization method of PV system into power grid. Keywords: grid-connected PV systems, power control, interconnection standard, phase shifting 1. INTRODUCTION Renewable energy sources such as solar energy, wind power, biomass and geothermal energy are abundant, inexhaustible and widely available. The development and use of renewable energy sources can enhance diversity in energy supply markets, contribute to securing long-term sustainable energy supplies, and help reduce local and global environmental impacts. Photovoltaic (PV) power system has attracted the interest of governments, industry and researchers alike due to its zero greenhouse gas emission. It consisting of solar cells converts sun light into electricity through the photoelectric effect. This system is being used regularly to supply electricity to individual and/or grid-connected systems. Grid-connected PV systems have many technical advantages such as flexibility, simplicity to install in many area where the solar

Nguyen Xuan Truong et al irradiation is available, being non-polluting, emitting no noise and requiring little maintenance [1]. The PV system shows a non linear current-voltage characteristics varying with the irradiance and temperature which affects its power output. It is normally used a maximum power point tracking (MPPT) technique to continuously deliver highest possible power in different conditions. The MPPT control is critical for the success of a PV generation system [2]. In application of PV system connected to the grid, the core technology associated with PV system is an inverter unit that converts the solar output electrically (DC voltage) to the utility grid (AC voltage) with nominal specification same with grid s specification (angle, frequency, amplitude). The main purpose for PV grid-connected system is to control the power flow between the primary renewable energy source and the grid, as well as the power factor of PV inverter-grid connection with high power quality [3-5]. This paper is organized in the following manner: Section 2.1 introduces the basic operation principle of the PV grid-connected system. Section 2.2 describes the control strategy based on the phase shifting of the inverter output voltage. Section 3 shows the simulation results demonstrating the validity and performance of the control strategy. Conclusions are finally drawn in the last section. We focus only on the interconnection and use of PV in low-voltage grid for household s application. The voltage output of the PV grid-connected inverter must be obeys the standards given by the power company in general, such as safety conditions, grid s specification, and synchronization conditions [6]. 2.1 Operational principle 2. GRID-CONNECTED PV GENERATION SYSTEM Figure 1(a) shows the configuration of the grid-connected PV system for single-phase inverter composed by a DC/DC Boost converter, and in cascaded with an inverter DC/AC. The DC/DC Boost converter performs MPPT for maximizing the output power of PV array to fully utilize the PV power and voltage boost to match that of grid inverter. The boost converter controls the PV array operating point by the switch duty command, and the post single phase inverter controls the DC-link capacitor voltage C PV and controls the output current to be in-phase with the grid voltage. Then a single-phase buck DC/AC inverter with four power switches IGBT is used to step down and to modulate the output voltage according to the grid voltage (±10, 49.7 50.3 Hz, and 220 Vrms ±10%). Power switches are controlled by a pulse-width modulation (PWM) technique to open and close in low and supply AC voltage to the grid. Commonly, energy storage elements, such as the DC-link capacitor C DC, are used to compensate the difference between the DC power from the PV array and the time-varying instantaneous power absorbed by the grid. The filter f C f is designed to reduce high-order harmonics introduced by the sinusoidal pulse generator of the DC/AC inverter. Moreover, the control of the power flow to the grid, according to the European standards (EN 61727), is based on the control of active and reactive power [3, 6]. The shortage of load power from the PV array is supplemented by the grid. On the contrary, the excessive power from the PV array to the load can be fed to the grid. The balance of power flow is controlled through the inverter.

Power control of a photovoltaic system connected to a distribution grid in vietnam (a) (b) Figure 1. Single-phase inverter connected to the grid (a), Phase diagram of E, V, I out, U and angle δ (b) 2.2. Power control method for a single phase grid-connected PV generation system 2.2.1 Grid-connected inverter control description The characteristics of the circuit can be understandable when see on the Figure 1(b), which represents the phase diagram of the fundamental components, including the inverter output voltage (E), the inverter output current (I out ), the drop voltage on the inductance (V = jx I out ), and the fundamental component of the grid (U) [4, 5]. φ is power angle the phase shift between the grid voltage and the inverter output current. And, δ represents for phase shift between inverter output voltage (E) and grid voltage (U). The following equation can be expressed, according to the figure 1: E U V U jx I out (1) Esin V cos X I cos (2) out The active power (P) output of inverter inject to grid can be expressed as following: U. E sin P UIoutcos (3) X And the reactive power (Q) provided by the converter to the grid can be represented: Q U. I out sin (4) X. I Q out.sin E cos U U E cos U X Base on the figure (1) and equation (3), it can seen that the active power inject in to grid will be affected by the variable of grid voltage (U), inverter output (E), inductance and also the shift angle (δ) between inverter output voltage and grid voltage. On the other hand, to inject power into grid, the value of the DC voltage must be high enough so that the output voltage E can get a value which is equal or greater than the grid peak voltage. (5)

Nguyen Xuan Truong et al It can also be deduced that active power (P) can be controlled by change the value of amplitude of E and the phase shift (δ). However, the injected power into grid affected direct proportional by the grid voltage (U). So, the PV energy send into grid will be changed if the amplitude of U variation. According to equation (5) at the same time, the reactive power can be controlled by the inverter output voltage magnitude (E) [2-6]. 2.2.2 Power control structure for single-phase Grid-connected PV The control structure for a single-phase inverter grid-connected is shown in the figure 2(a) [2-6]. The system is composed of a PV array, a DC/DC converter with MPPT controller, a PWM single-phase inverter DC/AC, and an active and reactive power controller. The control circuit consists of two stages. The front stage controls the active power injected and/or absorbed into grid by the phase shift (δ), and the latter stage controls the reactive power through the inverter output voltage magnitude (E). The control structure is associated with proportional-integral (PI) controllers since they have a satisfactory behavior when regulating DC variables. As show in figure 2(a), the capacity of PV source (P r ),-the reference signal, is compared with output active power of inverter P g which produced by the controller, generating an active power error. This different active power through PI controller, the principle of controller is repeat that the higher or lower of active power is injected into grid will be adjusted by reducing or increasing the value of sin(δ) in order to keep equation (3) constant. Resulting is corresponding shift angle δ. This angle is then added to phase-angle of grid voltage (θ u ), and generate output voltage phase-angle of inverter is (δ+ θ u ). On the other hand, the controller compensate the reactive power injected into the grid (Q g ) and compares it with its reference Q r, - the output capacity of PV inverter, originating an reactive power error. This value pass the other PI controller, the output that is suitable voltage ΔE is added to grid voltage amplitude U m. The output voltage amplitude E m is result of this processing. The amplitude E m is multiplied by sin(δ+ θ u ), the output of inverter is represented below: e E m sin( ), where u E U E (6) m m This control strategy is implementation at control circuit at digital sinusoidal pulse width modulation. We shift the time generate pulse which to active open IGBT, the method creates the delays the time generate pulse is t (second). The time (t) is calculated as below: T t T T(1 ) (7) 0 0 360 360 Where, (t) the shifting time correspond to shift angle δ, and (T) the period of grid voltage. At that time we have the inverter voltage output earlier than grid voltage shift angle is δ. 3. SIMUATION RESUTS AND DISCUSSION In this report we assign a constant value to output voltage of PV source, this is responsibility of MPPT technique and DC/DC Boost converter. So it is working as constant DC source. Matlab/simulink software were used in all simulations, which shows the results obtained for voltage waveform, active, reactive and apparent powers on the AC side supplied to the grid. The rate value of grid voltage (U = 220 Vrms) and the inverter is connected to the grid through a coupling inductance g = 10 mh. A simulation at low power scale (less than 3 kw) is implemented in predicting the behavior of the system for experiments will be performed on our laboratory test bench and because it is suitable for household scale.

Power control of a photovoltaic system connected to a distribution grid in vietnam 3.1. Variation of load Figure 2(b) represented how inverter output power and grid power influence by local load variation. In this situation, the inverter is connected to grid at 0.02 (sec) without load, it can be seen the output active power of inverter (P Int = 732 watt) is injected into grid fully, pink curve is the active power of grid receive or inject to load. At 0.08 sec to 0.16 sec, the load is connected to system with 242 watt, it can be seen that the red curve is represented for power of load by time. During this period the grid receive less power from inverter, the power reduction equal load power. At 0.16 sec the load demand increase to 1500 watt, over the capacity of inverter, the local load consumes power on both inverter and grid site. The output power of inverter is stable although power of load change. (a) (b) Figure 2. Control structure for a single phase grid-connected PV system (a) [2-5], Inverter output power and grid power respond to variation of local load (b) 3.2. Variation of grid voltage The Figure 3(a) shows behavior of output power of inverter corresponding to grid voltage. The grid voltage is kept at 220 volt until 0.04 sec, inverter inject active power to grid is 667 watt as shows on red curve. At 0.04 sec the grid voltage is reduced to 200 volt, the corresponding inverter power output is reduced to 623 watt. At 0.08 sec, the grid voltage is increase to 240 volt, the inverter power output is increase to 672 watt. The grid receives active power is represented by blue curve, amounts of power equal to output power of inverter at correspond time. (a) (b) Figure 3. Inverter output power and grid power respond to variation of grid voltage (a), and respond to variation shift angle δ (b)

Nguyen Xuan Truong et al 3.3. Variation of shift angle between inverter voltage and grid voltage The relation between inverter output power and shifting angle δ are represented by red curve in Figure 3(b). Inverter is controlled to inject power into grid at 0.08 sec, it take a 0.1 sec to reach stable and keep constant around 900 watt correspond at δ=9 until 0.2 sec. At that time we control the δ reduce from 9 to δ = 8, result is output inject in to grid is fluctuated and stable at lower value around 500 watt. At 0.3 sec, we increase δ to 10, the output power increase back and stability around 1300 watt. On the other hand, the blue curve show the grid absorb power, and this value as same as output power of inverter. 4. CONCUSIONS This work presented the power control shifting phase technique for controlling a power of the single phase grid-connected PV system, which controls inverter output power by control the phase angle δ between PV inverter output voltage and grid voltage. This control strategy does not require complicated device, it is foundation for promotes low cost grid-connected PV system. It allows controlling not only an active power needs to be injected into grid but also a reactive power. When the reactive power reference is zero, the power factor will approach to the unity. The modeling and simulation of a single-phase grid-connected PV system was carried. The simulation results express quite clear the behavior of inverter output how influence by variation of grid voltage, the phase angle δ between the inverter output voltage respect to the grid voltage and loader. The results are explainable by theory and also it help to give a study about interconnection standard of PV system into power grid. In addition, the results of test in real time were being carried out on experimental bench in our laboratory with the real conditions (solar radiation, grid conditions, load conditions). The experimental results were corresponding to the proposal control method and simulation results. 5. REFERENCES 1. Makrides G, Zinsser B, Norton M, Georghiou G, Schubert M, and Werner J. Potential of photovoltaic systems in countries with high solar irradiation, Renewable Sustainable Energy. Reviews. 15 (2010), pp. 754-762. 2. Hassaine, Olias E, Quintero J, and Barrado A. Power control for grid connected applications based on the phase shifting of the inverter output voltage with respect to the grid voltage, Electrical Power and Energy Systems. 57 (2014), pp. 250-260. 3. Guerrero-Rodriguez N. F, Herrero-de ucas. C, Alexis. B. Rey-Boué, and Martinez- Rodrigo F. Control and synchronization algorithms for a grid-connected photovoltaic system under harmonic distortions, frequency variation and unbalances, Electric Power Systems Research 80 (2015), pp. 380-395. 4. Rezapour E, Tavakoli Bina Md, Hajizadeh A. Active and reactive power controller for single phase connected photovoltaic systems, International Journal of Emerging Science and Engineering. 2 (5) (2014), pp. 22-24. 5. Tran-Cong B, Mai-Tuan D, Ngo-Manh D, Phan-Quang A, Pham-Dinh T and Nguyen-Huu P. Active and reactive power controller for single-phase grid-connected photovoltaic systems, Proceedings of AUN-SEEDNet Conference on Renewable Energy- Bandung- Indonesia, March (2009). 6. IEEE Standard for Interconnecting distributed resources with electronic power systems, IEEE 1547-1, (2005).