MIFAB SAMPLE FIXTURE SCHEDULE & SPECIFICATIONS

Similar documents
MIFAB Master Specification. Plumbing Drainage & Specialties - Specification For Commercial, Industrial & Institutional Facilities

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

FLOOR AND AREA DRAINS

FIXTURE CARRIERS TABLE OF CONTENTS S-WD-FC

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

SECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms.

Grease Interceptors. Design & Operation. Material & Characteristics

DIVISION 22 PLUMBING

C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers.

SECTION PLUMBING PIPING SYSTEMS. A. Types of plumbing piping systems specified in this section include the following:

SECTION FACILITY SANITARY SEWERS

200 Series In-Slab Pool Fittings

Specification Drainage Engineering Guide. Hydrants.

LIT-058 ROOFGUARD-2017 The Uncloggable Roof Drain Dome Go to for the most current product specification sheets.

ENGINEERING COMMUNIQUÉ

Series Sump and Sewage Systems

1 Exam Prep Florida Building Code- Plumbing, 2014 Tabs and Highlights

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION FACILITY SANITARY AND VENT PIPING

C. Up to Two and One-half (2-1/2) inches: Full port, 2-piece, bronze body ball valves with teflon seat conforming to MSS SP-110.

Duravit Vero toilet with Geberit Monolith in White Glass. Geberit Product Catalog May 2013

Copyright 2017, ProVent Systems Inc., All Rights Reserved

Technology. Enabling Design. Geberit Duofix Carrier

Engineering Design Center. Standard Drawings. 1st Edition -January 2016

CHAPTER 7 SANITARY DRAINAGE SYSTEMS

CI/SfB (52) Drainage Systems. frostdrainage.com

Jay R. SMITH Mfg. Co.

C. Inspect all waster lines and repair all joints that are leaking. Replace all damaged or broken drain lines.

Water Service Inspection Checklist

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter X X X Adopt Entire Chapter as amended (amended sections listed below) X X X X X X

PORT OF SAN FRANCISCO PLUMBING CODE. Based on the 2010 California Plumbing Codes

EDP NO PAGE: 1 OF 11 SUPERSEDES:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION COOLING TOWER

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

GENERAL REGULATIONS CHAPTER 3

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

SECTION FACILITY STORM DRAINAGE

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)

2015 UPC Chapter 6 Water Systems Part 1 RV

CHAPTER 6 WATER SUPPLY AND DISTRIBUTION

COMMERCIAL CONSTRUCTION INFORMATION PACKET Implemented: November 1, 2011 Revised: January 15, 2015

Roof Drains. Specification Drainage Engineering Guide

WB produces >>> FLOATING ROOF DRAIN SYSTEMS 2. ALUMINUM DOME COVERS 3. INTERNAL FLOATING ROOF SYSTEMS 4. EXTERNAL FLOATING ROOF SEAL SYSTEMS

Concealed Flushing and Installation Systems. PERFORMANCE AND INNOVATION

Specifications. Waterhill ExactTemp with 5 Function Transfer Valve Vertical Spa CRITICAL DIMENSIONS DESCRIPTION

2010 FBC General Requirements, Plumbing

Sanitary Drainage Systems PSD 175. Continuing Education from Plumbing Systems & Design MARCH 2011 PSDMAGAZINE.ORG

CHAPTER 7 SANITARY DRAINAGE

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

CARRIER SELECTION AND FIXTURE ROUGHING-IN DIMENSIONS

CUMULATIVE ANALYSIS OF UNIFORM PLUMBING CODE CHANGES

CHAPTER 7 SANITARY DRAINAGE

Estimate Form for Bathroom Design and Installation

NOTICE OF DISCONTINUATION,

No # Specifications Rate To Be Quoted. Unit Qty (in figures) (in words) Total Amount

SERVICE LINES, METERS AND APPURTENANCES

The following tubing can be supplied from stock, on futures or on a periodic release program which we can design to fit your needs.

D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Valves. MUELLER Tapping Sleeves and Crosses. MUELLER Stainless Steel Tapping Sleeves

The Ultimate Home Value with Quality,

Geberit Duofix. Need a frame for every application? There s a Geberit for it.

ADDENDUM NO. 1. Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities

SPECIFICATIONS FOR THE INSTALLATION OF REDUCED PRESSURE BACKFLOW PREVENTERS AND CONCRETE VAULTS FOR METERS 4 AND LARGER

COLONIAL PLANS. 708 North Street US Highway Route 1 Houlton, Maine (207)532,2444

Natural Gas Service Installation and Meter Clearance Requirements

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

SIDEWALK & RAILING REPLACEMENT BOARD OF ED BUILDING

3. Sanitary Plumbing Single Stack System

OVERHEAD SERVICE DISTRIBUTION

Installation Standard For PVC BUILDING DRAIN, WASTE AND VENT PIPE AND FITTINGS IAPMO IS

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

K FAIRFAX BATH & SHOWER TRIM SET ALSO K-T12007, K-12014, K-T Codes/Standards Applicable Specified model meets or exceeds the following:

DUKE UNIVERSITY CONSTRUCTION STANDARDS

Typical Finished Basement Details

PARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 )

HOSPITALITY BARRIER-FREE RESIDENTIAL COMMERCIAL

Chapter 3: General Regulations

Bathrooms for Behavioral Healthcare Facilities

INSTALLATION STANDARD FOR ABS BUILDING DRAIN, WASTE, AND VENT PIPE AND FITTINGS IAPMO IS

ELLA S MILLENNIAL SERIES

Vertical Turbine Pumps

Fairfax County, Virginia

ACO Drainage for Medical and Health Care Centers Explore the innovative range of ACO Drainage

Sprinkler Identification Numbers (SINs)

WATER SUPPLY AND DISTRIBUTION

Pre-Sloped Drain System

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210)

1. Unified Facilities Criteria - Design: General Building Requirements (UFC ).

karsten castle limited

UL / FM D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves

KITCHEN REMODELS CITY OF MISSION VIEJO BUILDING SERVICES DIVISON 200 CIVIC CENTER, MISSION VIEJO, CA (949)

ADDENDUM. Project: BYU-I Smith Building Chiller Replacement Project No.: Addendum No.: 1

CHAPTER 6 WATER SUPPLY AND DISTRIBUTION

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR GLASS LAVATORIES, SINKS AND COUNTER TOPS IAPMO IGC

B. Drainage Piping: Building sewer piping outside building that conveys storm drainage from building.

GCI60 Hampton Cast Iron Pellet Insert

Transcription:

ITEM FIXTURE WASTE WATER DESCRIPTION NOTES OPTIONS MIFAB # F1102-5-1-7 MIFAB TRAP PRIMER FD-1 w/ 2 ½ CAST IRON DRAIN, w/ 5 DIA. MIFAB # F1102-C-5- & TRAP PRIMER 1-7 FD-2 w/ MIFAB # F1102-5-1 CAST IRON DRAIN, w/ 5 DIA. MIFAB # F1102-C-5-1 FD-3 w/ MIFAB # F1102-5-3 CAST IRON DRAIN, w/ 5 DIA. ROUND MIFAB # F1102-C-5-3 FD-4 w/square STRAINER & TRAP PRIMER 2 ½ MIFAB # F1102-S5-1-7 CAST IRON DRAIN, w/ 5 SQUARE MIFAB TRAP PRIMER MIFAB # F1102-C-S5-1-7 FD-5 w/square STRAINER MIFAB # F1102-S5-1 CAST IRON DRAIN, w/ 5 SQUARE MIFAB # F1102-C-S5-1 FD-6 w/ SQUARE STRAINER MIFAB # F1102-S5-3 CAST IRON DRAIN, w/ 5 SQUARE MIFAB # F1102-C-S5-3 FD-7 w/ 8 DIA. ROUND STRAINER MIFAB # F1104-8-3 CAST IRON DRAIN, w/ 8 DIA. ROUND MIFAB # F1104-C-8-3 FD-8 w/ FUNNEL & TRAP PRIMER 2 ½ MIFAB # F1102-EF-1 CAST IRON DRAIN, w/ 5 DIA. NICKEL BRONZE STRAINER & FUNNEL MIFAB TRAP PRIMER MIFAB # F1102-C-EF-1 FS-1 FLOOR SINK, 8 Dia. w/ THREE QUARTER ROUND GRATE 2 MIFAB # FS1752-175 8 DIA. x 6 DEEP ENAMELD CAST IRON FLOOR SINK w/ 3/4 GRATE MIFAB # FS1752-FL-C-175 FS-2 FLOOR SINK, 12 Dia. w/ THREE QUARTER ROUND GRATE 2 MIFAB # FS1762-175 12 DIA. x 8 DEEP ENAMELD CAST IRON FLOOR SINK w/ 3/4 GRATE MIFAB # FS1762-FL-C-175 FS-3 FLOOR SINK, 8 Sq. w/ THREE QUARTER SQUARE GRATE 2 MIFAB # FS1522-175 8 x 8 x 6 DEEP ENAMELD CAST IRON FLOOR SINK w/ 3/4 GRATE MIFAB # FS1522-FL-C-175

FS-4 FLOOR SINK, 12 Sq. w/ HALF GRATE 2 MIFAB # FS1722-150 12 x 12 x 6 DEEP ENAMELD CAST IRON FLOOR SINK w/ HALF GRATE MIFAB # FS1722-FL-C-150 FS-5 FLOOR SINK, 12 Sq. w/ HALF GRATE 4 MIFAB # FS1734-150 12 x 12 x 8 DEEP ENAMELD CAST IRON FLOOR SINK w/ HALF GRATE MIFAB # FS1734-FL-C-150 AD-1 w/ 8 SQUARE STRAINER MIFAB # F1104-S8-3 CAST IRON DRAIN, w/ 8 SQUARE MIFAB F1004-C-S8-3 AD-2 2 ½ MIFAB # F1303-4 CAST IRON DRAIN, w/ 7 DIA. ROUND MIFAB TRAP PRIMER MIFAB # F1303-C-4 AD-3 3 - MIFAB # F1324-4 CAST IRON DRAIN, w/ 9 DIA. ROUND FOR UNDER-DECK MIFAB # F1324-C-4-40 MIFAB # F1324-C-4 AD-4 MIFAB # F1344-4 CAST IRON DRAIN, 12-3/4 ROUND FOR UNDER-DECK MIFAB # F1344-C-4-40 MIFAB # F1344-C-4 AD-5 6 - MIFAB # F1366-4 CAST IRON DRAIN, 15-3/4 ROUND FOR UNDER-DECK MIFAB # F1366-C-4-40 MIFAB # F1366-C-4 CO-1 w/ 5 DIA. ROUND NICKEL BRONZE 2, 3, MIFAB # C1222-R-1 CAST IRON FERRULE CLEANOUT BODY w/ ADJ. 5 DIA. NICKEL BRNZ. AND 3½ BRASS PLUG 3 LINE SIZE: C1223-R-1 4 LINE SIZE: C1224-R-1 CO-2 w/ 5 DIA. ROUND 6-8 - MIFAB # C1226-4 CAST IRON CLEANOUT BODY w/ ADJ. 8 DIA. 10,000LB DUCTILE IRON AND BRASS PLUG FOR 8 LINE SIZE: C1228-4 CO-3 w/ 5 SQUARE NICKEL BRONZE MIFAB # C1102-S-1 CAST IRON CLEANOUT BODY w/ ADJUSTABLE 5 SQUARE NICKEL BRONZE # C1102-C-S-1 FOR 4 LINE USE C1104-S-1 CO-4 w/ 5 SQUARE MIFAB # C1002-S-3 CAST IRON CLEANOUT BODY w/ ADJUSTABLE 5 SQUARE 7,499 lb RATED # C1002-C-S-3 FOR 4 LINE USE C1104-S-3

CO-5 WALL CLEANOUT w/ 6 DIA. ROUND - - MIFAB # C1434-RD6 6 DIA. WALL CLEANOUT, WITH THREADED BRONZE LINE PLUG DD-1 DECK DRAIN w/ 8 SQUARE STRAINER MIFAB # F1104-S8-3 CAST IRON DRAIN, w/ 8 SQUARE FOR NICKEL BRONZE SQUARE STRAINER USE # F1104-S8-1 MIFAB F1004-C-S8-3 RD-1 8 DIA. ROOF DRAIN MIFAB # R1102-M-B-U, 8 DIA. CAST IRON DRAIN, w/ METAL DOME, SUMP RECEIVER, & ROOF DRAIN R1102-EU-M RD-2 8 DIA. ROOF DRAIN 3 - MIFAB # R1103-M-B-U, 8 DIA. CAST IRON DRAIN, w/ METAL DOME, SUMP RECEIVER, & COUPLING # R1903 ROOF DRAIN R1103-EU-M RD-3 8 DIA. ROOF DRAIN MIFAB # R1104-M-B-U, 8 DIA. CAST IRON DRAIN, w/ METAL DOME, SUMP RECEIVER, & ROOF DRAIN R1104-EU-M RD-4 RD-5 8 DIA. ROOF DRAIN CONDENSATE RECEIVER 8 DIA. ROOF DRAINS w/ COMBINATION MIFAB # R1102-RS-B-U 8 DIA. CAST IRON DRAIN, w/ NICKEL BRONZE STRAINER EXTERNAL DAM MIFAB # R1152-M-U, 12 x 24 SUMP RECEIVER, CAST IRON DRAINS, WITH OVERFLOW, METAL DOMES, (2) MIAFB EXPANSION RD-6 8 DIA. ROOF DRAINS w/ COMBINATION MIFAB # R1154-M-U, 12 x 24 SUMP RECEIVER, CAST IRON DRAINS WITH OVERFLOW, METAL DOMES, (2) MIAFB EXPANSION RD-9 15 DIA. ROOF DRAIN MIFAB # R1204-M-B-U, 15 DIA. ROOF DRAIN R1204-EU-M RD-10 15 DIA. ROOF DRAIN 5 - MIFAB # R1205-M-B-U, 15 DIA. ROOF DRAIN R1205-EU-M

RD-11 15 DIA. ROOF DRAIN 6 - RD-12 15 DIA. ROOF DRAIN 8 - MIFAB # R1206-M-B-U, 15 DIA. MIFAB # R1208-M-B-U, 15 DIA. ROOF DRAIN R1206-EU-M ROOF DRAIN R1208-EU-M RD-13 16 DIA. HIGH FLOW ROOF DRAIN 10 - MIFAB # R1261-M-B-U, 16 DIA. CAST IRON HIGH FLOW ROOF DRAIN, w/ METAL DOME, SUMP RECEIVER, & R1261-EU-M OD-1 8 DIA ROOF DRAIN MIFAB # R1102-R-M-B-U 8 DIA. (2) R1102-EU-R-M OD-2 8 DIA ROOF DRAIN MIFAB # R1104-R-M-B-U 8 DIA. (2) R1104-EU-R-M OD-5 15 DIA ROOF DRAIN MIFAB # R1204-R-M-B-U 15 DIA. (2) R1204-EU-R-M OD-6 15 DIA ROOF DRAIN 6 - MIFAB # R1206-R-M-B-U 15 DIA. R1206-EU-R-M OD-7 15 DIA ROOF DRAIN 8 - MIFAB # R1208-R-M-B-U 15 DIA. R1208-EU-R-M OD-8 16 DIA. HIGH FLOW 10 - MIFAB # R1261-R-M-B-U, 16 DIA. CAST IRON HIGH FLOW OVERFLOW DRAIN, w/ METAL DOME, SUMP RECEIVER, & R1261-EU-R-M

FIXTURE CARRIERS ITEM FIXTURE CARRIER WASTE VENT DESCRIPTION NOTES OPTIONS MIFAB # MC-10L/R SINGLE FLOOR FOR ADA HEIGHT FOR AN ADDITIONAL 2 WC-1 SUPPORTED, LEFT/RIGHT-HAND FIXTURES LOCATED IN VENT/INLET USE MC-10L/R-27. HORIZONTAL WASTE, ADJUSTABLE THE MIDDLE OF A (Horizontal Waste) WATER, 4 NO- BATTERY OF CLOSETS HUB, 2 VENT USE MC-10L/R-EXT MC-10L/R-CI-8 WC-2 BACK-TO-BACK (Horizontal Waste) MIFAB # MC-10L/R-D BACK-TO-BACK FLOOR SUPPORTED, LEFT/RIGHT- HAND HORIZONTAL WASTE, ADJUSTABLE WATER CLOSET CARRIER, 4 NO-HUB, 2 VENT WC-3 MIFAB # MC-13L/R SINGLE FLOOR SUPPORTED ADJUSTABLE WATER, WITH VERTICAL WASTE, AND WITH LEFT/RIGHT- HAND INLET, WITH 4 NO-HUB CONNECTIONS, 2 VENT MC-10L/R-CI-8 WC-4 BACK-TO-BACK MIFAB # MC-13L/R-D BACK-TO-BACK FLOOR SUPPORTED ADJUSTABLE WATER, WITH VERTICAL WASTE, AND WITH LEFT/RIGHT-HAND INLET, WITH 4 NO-HUB CONNECTIONS, 2 VENT WC-5 MIFAB # MC-12 FLOOR SUPPORTED, VERTICAL WASTE, ADJUSTABLE WATER, 4 NO- HUB, 2 VENT WC-6 BACK-TO-BACK MIFAB # MC-12D BACK-TO-BACK FLOOR SUPPORTED, VERTICAL WASTE, ADJUSTABLE WATER, 4 NO-HUB, 2 VENT UR-1 WALL-HUNG URINALCARRIER MIFAB # MC-32 FLOOR SUPPORTED URINAL CARRIER, ADJUSTABLE HANGER PLATE WITH ADDITIONAL SUPPORT BEARING PLATE, FOR BACK-TO-BACK CARRIER ASSEMBLY USE # MC-32-D L-1 WALL-HUNG CONCEALED ARM LAVATORY CARRIER MIFAB # MC-41 FLOOR SUPPORTED ADJUSTABLE, CONCEALED ARM LAVATORY CARRIER FOR BACK-TO-BACK CARRIER ASSEMBLY USE # MC-41-D

L-2 WALL-HUNG LAVATORY CARRIER MIFAB # MC-31 FLOOR SUPPORTED ADJUSTABLE LAVATORY CARRIER FOR BACK-TO-BACK CARRIER ASSEMBLY USE # MC-31-D EWC- 1 SINGLE WALL-HUNG ELECTRIC WATER COOLER CARRIER MIFAB # MC-31 FLOOR SUPPORTED ADJUSTABLE, ELECTRIC WATER COOLER CARRIER EWC- 2 HI-LO WALL-HUNG ELECTRIC WATER COOLER CARRIER MIFAB # MC-33 FLOOR SUPPORTED ADJUSTABLE, HIGH-LOW DUAL HEIGHT WATER COOLER CARRIER ITEM FIXTURE WATER DESCRIPTION NOTES OPTIONS TP-1 TRAP PRIMER ½ MIFAB PRESSURE DROP ACTIVATED TRAP SEAL PRIMER ACCESS UA12X12SS WHA-1 WHA-2 WHA-3 WHA-4 WHA-5 WHA-6 HB-1 HB-2 HB-3 ARRESTOR ½ ARRESTOR ARRESTOR 1 ARRESTOR 1¼ ARRESTOR 1½ ARRESTOR 2 HOSE BIBB WALL MOUNT w/ VACUUM BREAKER HOSE BIBB WALL MOUNT w/ VACUUM BREAKER HOSE BIBB RECESSED BOX w/ VACUUM BREAKER MIFAB # MWH-A MIFAB # MWH-B (for 1 to 11 fixture units) MIFAB # MWH-C (for 12 to 30 fixture units) MIFAB # MWH-D (for 31 to 60 fixture units) MIFAB # MWH-E (for 61 to 113 fixture units) MIFAB # MWH-F (for 114 to 154 fixture units) MIFAB # MHY-9041 FIP ROUGH BRASS MIFAB # MHY-9241 FIP POLISHED CHROME PLATED BRASS MIFAB # MHY-95 FIP ROUGH BRASS HOSE BIBB AND CAST BRASS RECESSED BOX ACCESS ACCESS ACCESS ACCESS ACCESS UA12X12SS ACCESS UA12X12SS WITH WITH WITH FOR DISTRIBUTION TO MULTIPLE DRAINS MIFAB # MI-DU FOR WHITE PRIMER COATED STEEL ACCESS PANEL, USE MIFAB UA10X10 FOR WHITE PRIMER COATED STEEL ACCESS PANEL, USE MIFAB UA10X10 MPFR10X10SS MPFR12X12SS MPFR12X12SS MPFR12X12SS

HB-4 HB-5 HOSE HYDRANT RECESSED BOX W/ VACUUM BREAKER HOSE HYDRANT RECESSED BOX W/ VACUUM BREAKER MIFAB # MHY-55 FIP POLISHED CHROME BRASS HYDRANT, NICKEL BRONZE BOX MIFAB # MHY-55-3 FIP POLISHED CHROME BRASS HYDRANT, BOX WITH WITH J. R. Smith to MIFAB General Series Comparison: J. R. Smith MIFAB 1010-1089 Series Roof Drains R1200 Series Roof Drains 1310 Series Roof Drains R1220 Series Roof Drains 1330 & 1470 Series Roof Drains R1100 Series Roof Drains 2005 Series Floor Drains F1100 Series Floor Drains 2100 & 2200 Series Floor Drains F1300 Series Floor Drains 2300 & 2400 Series Floor Drains F1400 Series Floor Drains 3020-3060 Series Floor Sinks FS1750 & FS1760 Floor Sinks 3100 & 3101 Series Floor Sinks FS1520 Series Floor Sinks 3110-3161 Series Floor Sinks FS1720 & FS1730 & FS1740 4000-4200 Series Cleanouts C1100 Series Cleanouts