Agilent G2615A Bar Code Reader

Similar documents
Conversion Station Model 711

EuroForm Barcode 100 User Guide

Universal Tilting TV Mount 32" to 60" Installation Instructions

Cavity Design and U-Channel Relationship

2-finger angular gripper SGB 32-50

OPERATOR S SAFETY MANUAL

BESTMOVE STANDING TRANSFER AID

BESTMOVE STANDING TRANSFER AID

BESTMOVE STANDING TRANSFER AID

BioPrism Solid Surface

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

Bruker BioSpin. Barcodes. for BRUKER Automation User Manual. Version. NMR Spectroscopy. think forward

2-Finger-Parallel-Gripper RH

MOUNTING SYSTEM FOR PITCHED ROOF WITH TILES. mounting system for pitched roof with tiles for solar panels in landscape setup. Rev

GroundTrac. Installation Manual

SpaVault TM Installation Guide for Bullfrog Spas (7-10 x 7-10 x 38 )

INSTALLATION INSTRUCTIONS. Wall Sleeve Kit. For Use With MGE/MCE/MHP Series Magic-Pak Unit

INSTALLATION GUIDE Sika SolarMount 1 Exposition East West

Soil Volume Change Meter (PVC)

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

Modular Coldroom Installation Manual

Normalization, Dilution and Transfer Methods for the Maxprep TM Liquid Handler Technical Manual

Pick Smarter. Pick Better. Pick UNEX. MODULAR FLOW-THROUGH WORK STATIONS FOR ASSEMBLY AND LINESIDE STORAGE

Installation Guide EcoFoot5D High Density 5-Degree Ballasted Racking System Document No. ES10560

Smarter. Safer. Leaner.

Installation. Smart-UPS VT in Parallel kva 380/400/415 V 208/220 V 200/208 V

DRYWALL DOLLY 900 LB. CAPACITY

Light Duty Ramps. Loadingdocksupply.com PHONE:

TWO-DIMENSIONAL GEL ELECTROPHORESIS THE FIRST DIMENSION

FW66 FORESTRY WINCH FW66. Owner s Manual 19/02/2016

Turbocharger / TPL-C Original assembly instructions English

DOUBLE SLIDE RAIL INSTALLATION METHOD. Double Slide Rail August

PS-4045 Adjustable-Height Pallet Stand Use and Maintenance Manual

Labels make the brand. krones Contiroll. Reel-fed labelling

BakeMax Dough Mini Moulder BMMDM02

Trench Duct Class Catalog 5230CT9601R10/08

MERIGAUGE MODEL 3900 OPERATING INSTRUCTIONS

Font DIMM Printer and Font DIMM Kit User s Guide (For use with Hewlett-Packard LaserJet P2055 Series Printers)

INSTALLATION GUIDE Tranquil Mount Model: TMO400A

Installation Manual. Orion. TL-3 Steel Barrier. VHD (v2)

Thank you for purchasing our product. *Please read these instructions and follow them step by step.

Kingspan Day-Lite Klick

7 PIECE TUBE FLARING KIT

ROOF MOUNT KIT OWNERS MANUAL

Streamline your Business Processes with Barcodes:

Breaking Strength and Elongation of Pressure Sensitive Tapes

Chapter 7. Roof Framing

RC9 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: R3 Updated April 2005

INDUSTRIAL CURTAINS INSTALLATION INSTRUCTIONS CHAIN SUPPORT MOUNTING

INSTRUCTIONS FOR THE ASSEMBLY AND INSTALLATION OF THE VORTOX LIQUID SAMPLER

Freedom One-Piece Barrier Free Showers Installation Instructions

Pneumatic PalletPal Level Loader

Air flue duct for use with ecotec boilers

This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated by these symbols.

R-Group Finland Oy. REA Lifting Inserts Technical Manual According to Eurocodes, EU Machinery directive 2006/42/EC and VDI/BV-BS 6205 CE Approved

PVC Project Assembly Guide a FORMUFIT field manual

ZS880 Linear Shower Drain Installation Instructions

TRANSFER THE QUARTZ BLOCK FROM THE ROLLER MECHANISM TO THE QB PRECISION MANIPULATOR CART

LOAD RAMP 1000 LB. CAPACITY

Elcometer 118/2. Moisture Meter. Operating Instructions

Cold Work Cladding Fabrication & Application

ArmorZone TL-2 Barrier and End Treatment

Automated Plate Replication

Mar Cor Purification. Carbon Block Filtration System. Operation & Maintenance Manual

COMPOSITE (WPC) ENGINEERED VINYL FLOORING INSTALLATION

TOUCH FOIL INSTALLATION GUIDE

Installation Instructions

ifix INSTALLATION MANUAL PV flat roof installation system Version

SECTION 15 CARTON REQUIREMENTS

TITAN Quadcopter Assembly Instructions 1

Com-Tray. Under Floor

Introduction to GS1 Barcodes. Performance, Packaged

RHE3 Dock Leveler Installation Manual

Operating Instructions

PORTA-FAB Cleanroom Wall Systems

SOLAR SHADING SYSTEMS - Manual Solar Shade SECTION ROLLER WINDOW SHADES

Instructions for 12 IGT system

Zone E Kohl s PO Number Style Number color size total units (if Prepack, total units by size and color)

Symmetra PX kw 208 V. Receiving and Unpacking 08/2015.

How to Conduct a Magnet Pull Test

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual

Instructions for Continued Airworthiness Talon LC Keeperless Cargo Hook Kit For the AS350 Series. System Part Number STC SR00886SE

A-44 J. Magnetic ERIEZ. Pull Test Kits. Digital Calibrated Kit includes NIST traceable digital scale

Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment.

Customer Packaging Guidelines

GS1 in Europe Logistic Label

Single Post Anchor Part Number Spectrum Lane ~ Missoula MT ~

Owner s Manual & Safety Instructions

General Guidelines. Tools Required. Instructions for Part # SC500-AF. Safety

Canopies & Exposed Structure Areas Commercial Ceilings and Walls Solutions Guide

Preparation and Installation of the FA, FAV, and FAS Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Thermo Scientific 8-Channel Handheld Screw Cap Capper/ Decapper. User Manual

VISE MOUNTED. Model 97359

STEP UP SHOWER BASE INSTALLATION GUIDE FOR TIMBER AND CONCRETE FLOORS

DL-NL-TS SERIES. Owner s/user s Manual. EOD Dock Leveler

CIRRUS AIRPLANE MAINTENANCE MANUAL

Fixed LCD TV/Monitor Mount 10" to 24" Installation Instructions

Spectralink PIVOT 8744 Smartphone. Barcode Administration Guide

ASSEMBLY INSTRUCTIONS. Due to continuing improvements, actual product may differ slightly from the product described herein.

Transcription:

Agilent G2615A Bar Code Reader User Information Agilent Technologies

Notices Agilent Technologies, Inc. 2002 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Agilent Technologies, Inc. as governed by United States and international copyright laws. Manual Part Number G2615-90007 Edition First edition, May 2002 Printed in USA Agilent Technologies, Inc. 2850 Centerville Road Wilmington, Delaware 19808-1610 USA Safety Notices CAUTION A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. WARNING A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. 2 Bar code reader

Agilent G2615A Bar Code Reader User Information Parts identification 4 Installation 5 About bar codes 7 Label and vial information 13 Applying labels 14 In case of difficulty 18 The Agilent G2615A Bar Code Reader (BCR) attaches to the tray of a 7683 Automatic Sampler. It reads labels attached to sample vials for positive sample identification. The reader attaches directly to the 7683 tray. A provided spacer may be required to attach some trays. The G2615A Bar Code Reader is not compatible with trays for 18596A, 18596B or 18596C samplers. The 7683 tray must be delivered from Agilent with A.01.04 or greater firmware. Field upgrade to A.01.04 or greater is not adequate. You can verify your tray firmware using the 6890N keypad and display. Select Options/Diagnostics/Instrument status. Scroll to observe what firmware is installed on the G2614A tray. 6890A and 6890 Plus GCs will not display the tray firmware. Contact your local Agilent office for assistance. Agilent Technologies 3

Parts identification Figure 1 identifies those parts in the installation kit that may not be easily recognized. Label applicator Vial plates Roll of labels Labeled vial Long screws 2-mm hex wrench Short screws Bar code reader with mounting bracket Spacer Cable Figure 1 Parts identification 4 Bar code reader

Installation 1 Locate the recess in the bottom front of the tray. The BCR must be located at this location. See Figure 2. Mounting screw holes Spacer mounts in this recess if needed Figure 2 Mounting location 2 Locate the mounting screw holes. Some trays have two holes that are flush with the bottom of the recess. Those trays require the spacer. Other trays have raised areas around three mounting holes and do not need the spacer. The tray shown in Figure 2 is the two hole version. This style tray requires use of the spacer to mount the BCR. 3 If the spacer is needed, align the holes in the spacer with the mounting holes in the bottom of the tray. Place the mounting bracket under the spacer, insert the two long screws and tighten them firmly. If the spacer is not needed, place the mounting bracket under the mounting holes in the bottom of the tray. Insert the three short screws and tighten them firmly. 4 Run the cable to the back of the tray and connect it to the Barcode receptacle. Tighten the two securing screws. See Figure 3. Bar code reader 5

Barcode receptacle Figure 3 Connecting the cable 5 This completes bar code reader installation. See the section on Automatic Samplers in your Agilent 6890 Series Gas Chromatograph user information to configure the bar code reader. 6 Bar code reader

About bar codes Bar code elements A bar code is a printed pattern of bars and spaces that encodes information. The most frequently encountered bar code is the UPC code (Universal Product Code) that appears on most packaged products in the supermarket. The information in a UPC symbol is not the price of the product; it is simply a number that has been assigned to that product to distinguish it from all others. The supermarket checkout register obtains the price by looking up the code in a master list (actually, the store computer does it). The Agilent Bar Code Reader (BCR) reads and decodes several different bar codes. The most useful one for general laboratory use is the Standard 3 of 9 Code, which encodes both letters and numbers and allows variable message length. The others may prove useful in special cases. The preprinted labels available from Agilent are in Standard 3 of 9 Code without a checksum. See Table 1. All codes represent the characters as a pattern of dark bars and light spaces. Some codes only distinguish between narrow and wide bars, some have several possible bar widths, some use spaces to encode characters, others use spaces only as bar separators, and so on. Why so many different ways of accomplishing the same simple task? They were developed by different groups at different times and for different purposes. Bar code reader 7

Standard 3 of 9 code Each character is represented by five bars and the four spaces between them. The bar/space patterns are defined so that exactly three are wide and the rest narrow. Characters are separated by a narrow space. See Table 1. Table 1 Standard 3 of 9 code properties Character set Capital letters: A to Z (check values 10 to 35) Numerals: 0 to 9 (check values 0 to 9) Other characters: -. space $ / + % (check values 36 to 42) Message length Checksum Variable Optional The three wide and six narrow requirement makes each character self-checking, but an additional checksum character may be inserted in the message if desired. The checksum is generated by adding the check values for all the message characters, dividing by 43, and using the remainder to select the checksum character. If a checksum is used, the character is placed after the message characters. When a checksum is used, the bar code reader verifies that the checksum in the message matches the checksum calculated from the message characters, but does not include the checksum character in the returned message. An extended 3 of 9 code includes the complete ASCII character set, but it is not read by the bar code reader. 8 Bar code reader

Interleaved 2 of 5 code Message length, including the checksum character if used, must be an even number. If it is not, a leading zero is inserted. See Table 2. Table 2 Interleaved 2 of 5 code properties Character set Numerals: 0 to 9 (check values 0 to 9) Message length Checksum Variable (may require a dummy character) Optional EAN/JAN-13 codes Each character is represented by five elements, of which two are wide and three are narrow. Characters in odd-numbered positions are encoded with five bars. Characters in even numbered positions are encoded with the five spaces associated with the preceding even character. There is no character separator. The printed EAN/JAN-13 symbol is divided into left and right halves by a pattern of narrow bars and spaces. Two different code pattern sets are defined for the left side and one for the right side. Bars and spaces may be 1, 2, 3, or 4 units wide. See Table 3. Bar code reader 9

Table 3 EAN/JAN-13 code properties Character set Numerals: 0 to 9 Message length Checksum 13 (2 country-of-origin characters, 10 data characters, 1 checksum character) Required EAN/JAN-8 codes The printed EAN/JAN-13 symbol is divided into left and right halves by a pattern of narrow bars and spaces. Two different code pattern sets are defined for the left side and one for the right side. Bars and spaces may be 1, 2, 3, or 4 units wide. The left side contains the code patterns for the country-of-origin characters and the first five data characters. The last five data characters and the checksum character are on the right side. The first country-of-origin character determines which of the left side pattern sets to use for the rest of the left side characters. For example, call the left side pattern sets A and B. If the first country-of-origin character is 0, the second country of origin character and the first five data characters will all be encoded using pattern set A (AAAAAA). If it is 1, the pattern sets for the left side are AABABB. A different pattern set is used for the right side characters. This is a variation on the EAN/JAN-13 codes. The left side consists of the two country-of-origin characters and the first two data characters, all encoded using the left side A pattern set. The right side contains the last three data characters and the checksum character, all encoded as right side characters. 10 Bar code reader

UPC codes The UPC-A symbols are a subset of the EAN/JAN symbols. There are two sides, but only one code pattern set for each side. The symbol is equivalent to an EAN/JAN-13 symbol with the first country-of-origin character set to 0 and the second one replaced by a number-system character. The number-system character depends on the kind of product and whether the symbol is applied at the factory (pre-packaged products) or at the store (weighed items such as meat). See Table 4. Table 4 UPC code properties Character set Numerals: 0 to 9 Message length Checksum UPC-A: 12 (1 number-system character, 10 data characters, 1checksum character) UPC-E: 6 (6 data characters & checksum character compressed into 6 encoded characters) Required The UPC-E code is called the "zero suppressed" version and is used for small packages. It requires that the number system character and at least four of the 10 data characters be 0 (zero). The Bar Code Reader can process both versions. UPC-E is not divided into halves but still uses two different code pattern sets. One is identical to the left side UPC-A set; the other is the reverse of the right side UPC-A set. The choice of which to use is based on the position of the data character and the value of the checksum. Bar code reader 11

Summary The Standard 3 of 9 code offers the greatest versatility for laboratory use. It can encode both letters and numbers, plus a few punctuation marks, and message length can be varied to suit both the amount of data to be encoded and the space available. Interleaved 2 of 5 code is restricted to numbers but does allow variable message length. The other codes are number-only and fixed message length. 12 Bar code reader

Label and vial information To minimize label and/or vial induced errors, always use labels and vials that meet the specifications in Figure 4 and Figure 5 respectively. No label or tape 3.6 min All dimensions in millimeters 5.6 ± 0.6 Bar code here Text here 20.5 ± 1.0 No label or tape 12.56 Maximum width measured at overlap Figure 4 Label dimensions 6.25 ± 0.25 3.7 8.2 ± 0.2 32 ± 0.5 All dimensions in millimeters 34.5 11.7 ± 0.2 Figure 5 Vial dimensions Bar code reader 13

Applying labels Label applicator One roll of preprinted labels, numbered from 1 to 1000, is provided with the bar code reader. This roll of labels is designed for use with the Label Applicator, discussed later in this section. To purchase additional labels, see your Agilent consumables and supplies catalog or visit our web site at www.agilent.com. If you have worked as an analyst for more than a day, you have encountered the problem of sample labels that do not stick to sample bottles. Rubber bands, transparent tape, putting the bottle and the (loose) label in a beaker these are some common solutions. But they will not work with bar code labels. The following hints will help avoid loose labels. Label adhesives have an annealing time during which the strength of the bond increases. For the Agilent labels, this is about 20 minutes. Give the label bond a chance to anneal before you stress it, whether mechanically or by placing it in a refrigerator or freezer. The Agilent labels have a slight overlap. Be sure that the tail of the label is firmly pressed down. The adhesive anneals best when both the label and the bottle are at room temperature. After the bond has strengthened, it will retain that strength when refrigerated. It is difficult to stick anything to a wet surface, including the thin film of moisture that condenses almost immediately on a bottle removed from a refrigerator. If you do find it necessary to overwrap the label with transparent tape, apply it smoothly and avoid placing the ends over the bar code itself. Keep the bottles and the labels clean. This improves both adhesion and readability. Do not write over the bar code. The Label Applicator (part number 18587-60530) supplied with the bar code reader applies Agilent preprinted labels in the correct position on the vial. 14 Bar code reader

Two vial plates are supplied with the applicator. The one marked UNCAPPED VIALS is used when applying labels to vials that have not been capped. Vials that have been capped will not fit in this plate. A second plate, marked CAPPED VIALS, allows for the extra length of the cap. While uncapped vials will fit in this plate, they may not be properly positioned when the label is applied. Loading labels The following instructions assume that Agilent labels are used. 1 Remove the screws holding the side plate. See Figure 6. 2 Remove the side plate and discard the empty roller (if any). 3 Unwrap a new roll of labels. Use care because the roll will tend to unwind. 4 Place a new roll of labels on the three posts. The labels must be on the outside of the roll and the roll must feed from the bottom. See Figure 6. Do not let tape uncoil Side plate Side Vial plate Figure 6 Loading labels 5 Replace the side plate and the screws. 6 Verify that the correct vial plate (CAPPED or UNCAPPED) is in place. If not, remove the four screws holding the top and bottom plates, make the change, and replace the screws. Bar code reader 15

7 The roll begins with a 12-label leader. These labels contain text but no bar code. Peel off and discard these leader labels. Cut the end of the backing tape to a point to make loading easier. 8 Feed the end of the tape under the bottom plate and up through the large opening. See Figure 7. Remove leader labels and cut to a point Pass tape under the bottom plate Figure 7 Threading the tape. Under the bottom plate. 9 Fold the tape and feed the end through the space between the bottom and top plates. It will help to bend the tip upward. See Figure 8. Top plate Bottom plate Figure 8 Threading the tape. Between the plates. 16 Bar code reader

10 Pull the backing through until it points straight up. See Figure 9. Label position guage Vial Figure 9 Ready to apply labels Using the applicator 1 Place a bottle in the opening in the top plate. It will only fit in one position (to the right). See Figure 9. 2 Pull the backing up until the end of a label appears under the bottle. 3 Hold the bottle in position (let it rotate) and continue to feed the label onto the bottle. 4 Remove the bottle and press down the trailing edge of the label. 5 Verify correct position with the gauge on top of the label applicator. With the bottle on the ledge, there must be no white space above or below the code and visible in the slot. See Figure 9. Bar code reader 17

In case of difficulty CAUTION Correct sample vial and label dimensions and label placement are critical for proper tray gripper operation. Vials and labels that do not meet the specifications in Figure 4 and Figure 5 may cause sampler errors. Service calls and repairs found to be due to vials or labels that do not meet these specifications are not covered under warranty or service contract. How the tray gripper works Labels Residue on gripper It slides over the vial body near the vial shoulder As the gripper rises, the vial may slide down in the gripper so that the underside of the cap rests on the top edge of the gripper fingers Bar code labels must not be in the gripper area. This may interfere with the gripper s ability to engage the vial. The maximum height of the top of the label, measured from the outside bottom of the vial, is 21.5 mm. Label thickness must not increase the vial outside diameter such that the vials do not fit in the various sampler, BCR, and tray locations. Labels or tape on the lower part of the vial may interfere with delivering the vial to its destination. Labels must be applied smoothly with no bumps. Ends must be securely fastened down. Bar code labels supplied by Agilent meet these restrictions when properly placed. Any buildup of residue (grease, label adhesive, etc.) on the gripper may interfere with its ability to engage the vials. Inspect gripper fingers periodically and clean if necessary. 18 Bar code reader

Vial caps Labeled test vial The vial is sometimes carried by the underside of the vial cap. It is important that the lowest edge of the cap is perpendicular to the sides of the vial. If this is not so, the vial may be carried at an angle and the base of the vial may miss its intended receptacle when lowered. A properly labeled test vial is provided with the bar code reader. It is labeled in Standard 3 of 9 code and the message (a number) is printed on the label. If you suspect that the reader is not working correctly, use this vial to verify that it does successfully read a properly labeled vial. Bar code reader 19

Agilent Technologies Agilent Technologies, Inc. Printed in USA, May 2002 G2615-90007