HPW Protocol Reference Manual

Similar documents
Boulder City NV Prepared by (Print Name) Signature Date

CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8)

Insulation Inspection Procedures. Inspection Requirement? Insulation Inspection Procedures. Assessment: Grade I. Boundary condition for Grade I

PREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

Plan Check & Field Inspection Guide

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

A. Source Limitations: Obtain each type of building insulation through one source.

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: RHINO LININGS CORPORATION

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

EcoTouch Insulation with PureFiber Technology

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

Questar ThermWise Duct Technical Specifications

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

Thermal Bridging in Residential Construction

GOWANDA, NEW YORK SEPTEMBER 18, 2008 ARCH PROJECT NO

BUILDING PERMIT APPLICATION

FIBERGLASS BATTS ACHIEVING GRADE I INSULATION WITH. Prepared by

Administrative Changes

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

Trusted DIVISION: 07 SYSTEM. Conformity! ICC-ES Evaluation. not specifically. Copyright 2014

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: NATURAL POLYMERS, LLC

2016 CALGREEN RESIDENTIAL CHECKLIST MANDATORY ITEMS City of San Carlos - Building Division 600 Elm Street, San Carlos, CA Phone:

Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards 2013 Residential Compliance June 2014

DIVISION: THERMAL AND MOISTURE SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

CHECKLIST Inspecting a Garage

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION (RIGID PU SYSTEMS)

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

Residential Accessory Structures & Room Additions

The Inspection Process. Waxhaw N.C.

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210)

1 Exam Prep Prov Module: Thermal and Moisture Protection Questions and Answers

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

2013 COMMERCIAL PRODUCTS

APPROVED. Acceptable to the code official for compliance with the provisions of the applicable Code or referenced Standard.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

HATFIELD TOWNSHIP DECK/PATIO PERMIT PROCEDURES

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

!"#!$%&'(%)*+,-./(0."1-+1)(234,)(5(6)7#/(!38,-.41-)9(23:)($;":<#)( (

Project Address: Name of Person Completing Form:

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

SPECIFICATION DIVISION 7 NUMBER SECTION DESCRIPTION DIVISION 07 THERMAL AND MOISTURE PROTECTION SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

Cellulose Insulation Products. Date: Submitted to: Submitted by: Job Reference: Job Name

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Originally Issued: 07/31/2015 Revised: 07/31/2017 Valid Through: 07/31/ General

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

2003 International Residential Building Code

Radon Vent Pipe System. Labeling Performance Indicators

Training Certification Categories

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition

Container Installation Guide

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 5 and Marine 4

BASEMENT FINISH CONSTRUCTION PLANS REFERENCE: 2015 INTERNATIONAL RESIDENTIAL CODE. PERMITS

Requirements for Additions/Enclosed Deck/Finished Bonus Room/Dormer

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE SPRAY MARKET, INC.

California Building Envelope Solutions

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

One and Two Family Additions

Trusted ICC ES DIVISION: ATLANTA, CGF PRO, ENERGYS. Look. Conformity! Evaluation. ICC-ES Evaluation

HCM UNIVERSITY OF ALASKA FAIRBANKS Building Challenges in Alaska UNIVERSITY OF ALASKA FAIRBANKS

Gold Bond BRAND Gypsum Sheathing

Advanced Ventilation for Residential applications FBC Res 2010.

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

INSPECTION GUIDELINES: JOIST AND UNDERFLOOR COMBO

Building Codes and Ordinances ARC 227

2

Continuous Insulation Systems for Exterior Walls

Container Installation Guide

NEW HOMES PROGRAM 2017 PROGRAM GUIDE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Is Yours? Homes Across Missouri are Being Built to the Latest National Energy Efficiency Standards

SECTION GYPSUM BOARD ASSEMBLIES

Chapter 2: Foundation

FIRE AND SMOKE PROTECTION FEATURES

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

Floor Plan. *The floor plan represents a section view of a residence which has had an imaginary cut made approximately 4 feet above the floor line.

Design & Construction Standards, Revised January

New Hampshire Residential Energy Code

INTERIOR ENVIRONMENT

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: CITADEL ARCHITECTURAL PRODUCTS, INC.

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

Transcription:

1 HPW Protocol Reference Manual

Change Log: UPDATED BY DATE UPDATED VERSION UPDATE DETAILS 2

Table of Contents: HIGH PERFORMANCE WALL ASSEMBLY... 4 THERMAL SPECIFICATION... 4 REQUIREMENTS FOR HPW INSULATION... 4 R-VALUE VERIFICATION... 6 CERTIFICATES... 6 CERTIFICATES AND AVAILABILITY... 6 BATT AND BLANKET INSULATION... 6 LOOSE FILL INSULATION... 7 RIGID BOARD INSULATION... 8 SPRAY POLYURETHANE FOAM (SPF) INSULATION... 9 STRUCTURAL INSULATED PANEL (SIP)... 10 INSULATED CONCRETE FORM (ICF)... 10 APPENDIX A: FORMS... 11 3

High Performance Wall Assembly These procedures detail the installation and inspection protocols necessary to qualify for Quality Insulation Installation (QII) for High Performance Wall Assemblies. These procedures must be field verified before the building construction permit is finalized in order to claim QII energy compliance. These procedures are to be followed by the insulation installer and a qualified Home Energy Rating System (HERS) rater must verify that the installed components adheres to these procedures in order to meet the requirements of the Standards. THERMAL SPECIFICATION The R-value of the component is dependent on the type of material and its thickness, and is typically marked on the product. Specific product R-values are readily available from the manufacturer for the specific materials being installed. The installed insulation must meet the R-value stated on the compliance documentation. REQUIREMENTS FOR HPW INSULATION a) Materials shall comply with, and be installed in conformance with, all applicable building codes. b) Materials shall meet California Quality Standards for Insulating Material, Title 24, Part 12, Chapter 4, Article 3, listed in the California Department of Consumer Affairs Consumer Guide and Directory of Certified Insulating Materials. c) Materials shall comply with flame spread rating and smoke density requirements of Chapter 26 and Section 706 of the Title 24, Part 2: all installations with exposed facings must use fire retardant facings which have been tested and certified not to exceed a flame spread of 25 and a smoke development rating of 450. Insulation facings that do not touch a ceiling, wall, or floor surface are considered exposed applications. d) Materials shall be installed according to manufacturer specifications and instructions. e) Wall stud cavities shall be caulked or foamed to provide a substantially air-tight envelope to the outdoors, attic, garage and crawl space. All plumbing and wiring penetrations through the top and bottom plates and electrical boxes that penetrate the exterior sheathing shall be sealed. All gaps in the air barrier shall be caulked, taped, or sealed with minimally expansive foam. 4

5 f) Bottom plates of framed and non-framed assemblies shall be sealed to the ground subfloor or slab, and above ground subfloor. g) Narrow spaces less than 1 inch in width at windows and door jambs, shall be filled with minimally expansive foam. h) Narrow spaces less than 2 inches in width, such as between studs at building corners, and at the intersection of interior partition walls to exterior walls, shall be filled with insulation snuggly fitted in the space, or with minimally expansive foam. i) Hard to access wall stud cavities, such as corner channels, wall intersections, and behind tub/shower enclosures shall be insulated to the proper R-value. In most cases this can only be completed prior to the installation of the tub/shower enclosure, the exterior sheathing, or the exterior stucco lath. j) An air barrier shall be installed on the inside of the exterior wall(s) directly adjacent to the tub/shower enclosure. k) Framing and bracing used for structural purposes shall be identified on plan documents with diagrams and/or design drawings. l) Insulation shall be installed in a manner that restricts thermal bridging through the structural framing assembly. m) Insulation shall be applied to fully enclose and/or adhere to all sides and ends of structural assembly framing that separate conditioned from unconditioned space. n) The structural portions of assemblies shall be air-tight.

R-VALUE VERIFICATION The HERS rater shall verify the installed thickness of the insulation in all assemblies and locations and shall ensure that insulation levels and installation integrity meet the R-value specified on the Certificate of Compliance, and all other required compliance documentation. CERTIFICATES a) All provisions of Residential Appendix RA2 shall be met. An Insulation Certificate of Installation signed by the insulation installer shall be provided that states the installation is consistent with the plans and specifications for which the building permit was issued. The certificate shall also state the installing company name, insulation manufacturer s name and material identification, and the installed R-value. The insulation installer shall also complete the applicable sections of the Certificate of Installation form and attach a product specification or data sheet for every insulation material used. b) For loose-fill insulation, compliance information shall include the minimum installed weight-per-squarefoot (or the minimum weight per cubic foot) consistent with the manufacturer s labeled installeddesign-density for the desired R-value, and the thickness in inches required to achieve the desired R-value. CERTIFICATES AND AVAILABILITY All provisions of Residential Appendix RA2 shall be met. The Insulation Certificate of Installation, with insulation material labels or specification/data sheets attached and signed by the insulation installer, shall be available on the building site for each of the HERS rater s verification inspections. Note: The HERS rater cannot verify compliance credit without these completed forms. BATT AND BLANKET INSULATION a) Batt and blanket insulation shall be correctly sized to fit snugly at the sides and ends. b) Batt and blanket insulation shall be installed so that they will be in contact with the air barrier. c) Where necessary, batt and blanket insulation shall be cut to fit properly - there shall be no gaps, nor shall the insulation be doubled-over or compressed. d) When batt and blanket insulation are cut to fit a non-standard cavity, they shall be snugly fitted to fill the cavity without excessive compression. e) Batt and blanket insulation shall be cut to butt-fit around wiring and plumbing, or be split (delaminated) so that one layer can fit behind the wiring or plumbing, and one layer fit in front. f) Insulation shall uniformly fill the cavity side-to-side, top-to-bottom, and front-to-back. g) Batt insulation shall fill the cavity by friction fitting, inset or face stapling of flanges of faced batts, or by other support methods as necessary. h) Batt and blanket insulation shall be installed to fill the cavity and be in contact with the sheathing on the back and the wallboard on the front - no gaps or voids. i) Batts with flanges that are inset stapled to the side of the stud must be flush with the face of the cavity (or protrude beyond) except for the portion that is less than two inches from the edge of the stud. j) Insulation shall be placed between the sheathing and the rear of electrical boxes and phone boxes. 6

k) In cold climates, where water pipes may freeze (such as Climate Zones 2, 11-14 and 16) pipes shall have at least 1/2 of the insulation between the water pipe and the outside surface of the exterior wall. If the pipe is closer to the exterior finish assembly layers, as much insulation as possible shall be placed between the pipe and the outside (without excessive compression), and remaining insulation shall be placed between the pipe and the interior assembly material. l) Insulation shall fill the entire cavity; or, an additional air barrier shall be installed inside the double wall or bump-out and in contact with the insulation so that the insulation fills the cavity formed with the additional air barrier. m) Entire double walls and framed bump-outs shall be air-tight. 7 LOOSE FILL INSULATION a) Loose fill insulation shall be installed so that it will be in contact with the air barrier. b) Loose fill insulation shall uniformly fill the cavity side-to-side, top-to-bottom, and front-to-back. c) Loose fill wall insulation shall be installed to fit around wiring, plumbing, and other obstructions. d) The installer shall certify on the Certificate of Installation forms that the manufacturer s minimum weight-per-square-foot requirement has been met. e) Loose fill insulation shall fill between the sheathing and the rear of electrical boxes and phone boxes. f) In cold climates, where water pipes may freeze (such as Climate Zones 2, 11-14 and 16) pipes shall have at least 1/2 of the insulation between the water pipe and the outside surface of the exterior wall. If the pipe is closer to the exterior finish assembly layers, as much insulation as possible shall be placed between the pipe and the outside (without excessive compression), and remaining insulation shall be placed between the pipe and the interior assembly material.

g) Loose fill insulation shall fill the entire cavity; or, an additional air barrier shall be installed inside the double wall or bump-out and in contact with the loose fill insulation so that the loose fill insulation fills the cavity formed with the additional air barrier. h) Entire double walls and framed bump-outs shall be air-tight. RIGID BOARD INSULATION a) Rigid board insulation shall be attached according to the manufacturer s specifications. b) Rigid board insulation may be used as the air barrier provided it has been tested to conform to the air barrier performance conditions of the Standards. c) Installation shall uniformly fit across the plane of the wall and taping and/or caulking of all joints and seams of the rigid board insulation shall be maintained to be considered as the air barrier. d) Penetrations and obstructions to the rigid board insulation shall be completely caulked and sealed. e) Rigid board insulation shall fill between the exterior sheathing and the rear of electrical boxes and phone boxes. f) Rigid board insulation shall fill the entire cavity; or, an additional air barrier shall be installed inside the double wall or bump-out and in contact with the rigid board insulation so that the rigid board insulation fills the cavity formed with the additional air barrier. g) Entire double walls and framed bump-outs shall be air-tight. 8

9 SPRAY POLYURETHANE FOAM (SPF) INSULATION a) The installer shall determine and the HERS rater shall verify that the manufacturer s nominal insulation thickness has been installed and certified and that all requirements of the Certificate of Verification have been met. b) The installer shall determine and the HERS rater shall verify that insulation is in substantial contact with the assembly air barrier. When SPF insulation is being used to provide air barrier control, the SPF insulation must cover and be in contact with the entire surface of the framing. c) SPF insulation shall be applied by SPF applicators trained and experienced in the use and maintenance of high-pressure, plural-component equipment. SPF applicators shall be certified by the SPF insulation manufacturer for the application of SPF insulation systems. d) SPF insulation shall be spray-applied to fully adhere to assembly framing within the construction cavity. When multiple layers of SPF material are applied, each foam lift (i.e. spray application) shall have adhesion at substrate and foam interfaces. SPF insulation shall not exhibit areas that: 1. Have voids or gaps in the uniformity of the insulation 2. Are extremely soft or spongy 3. Show the presence of liquid 4. Have blistering between lifts 5. Show differences in coloration of adjacent foam layers 6. Indicate the presence of other materials between lifts e) SPF insulation shall be installed in conformance with the manufacturer s specifications, recommendations and temperature/humidity limitations. f) Substrates to which SPF insulation is applied shall be secure and free of surface moisture, frost, grease, oils, dirt, dust or other contaminants that would adversely affect SPF adhesion. g) SPF insulation shall meet all provisions of the CBC Title 24, Parts 2 and 2.5. SPF shall be separated from occupied spaces by an approved thermal barrier, such as 0.5 inch gypsum wallboard or other approved material, or show equivalence through testing in accordance with CBC, Title 24, Part 2, Section 2603, and Part 2.5, Section R316. h) SPF insulation may be used as the air barrier provided it has been tested to conform to the air barrier performance conditions of the Standards. i) SPF insulation shall be kept away from combustion appliance flues in accordance with flue manufacturers installation instructions or labels on the flue for clearance. j) SPF insulation shall be applied to provide an air-tight envelope to the outdoors and between adjoining cavity surfaces of conditioned and unconditioned space, such as the: attic, garage, and crawl space. Special attention shall be paid to plumbing and wiring penetrations through the top plates and bottom plate framing, and electrical boxes that penetrate the sheathing and the sheathing seal to the top and bottom plate framing. k) SPF insulation installation shall uniformly cover the cavity side-to-side and end-to-end and shall be installed to cover and form an air barrier on the framing at the top, bottom and sides of each cavity. l) Non-standard width cavities shall be filled with SPF insulation at a depth consistent with the SPF thickness required to achieve the specified R-value. m) SPF insulation shall be applied to fully seal around wiring and plumbing. n) SPF insulation shall be applied to fully seal between the sheathing and the rear of electrical boxes and telephone boxes.

o) In cold climates, where water pipes may freeze (Climate Zones 14 and 16), pipes shall have at least 2/3 of the insulation between the water pipe and the outside surface of the exterior wall. If the pipe is near the exterior finish assembly layers, as much insulation as possible shall be placed between the pipe and the exterior assembly material. STRUCTURAL INSULATED PANEL (SIP) a) SIP systems are considered an air barrier; however, extension of the air barrier shall be made across all interconnections of panels, at window and door openings, and at all adjoining surfaces of different panel areas (i.e., where SIP walls adjoin the floor and roof/ceiling). b) Connections of wall panels shall be sealed, caulked, foamed, or taped (i.e., SIP tape) to provide a substantially air-tight envelope to the outdoors, attic, garage and crawl space. All plumbing and wiring penetrations through the top and bottom of panels, and electrical boxes that penetrate the SIP sheathing shall be sealed. All gaps in the air barrier shall be caulked, or sealed with minimally expansive foam or taped (i.e., SIP tape). c) Bottom connections of wall panels shall be sealed to the ground subfloor or slab, and above ground subfloor. d) Insulation shall uniformly fit across the plane of the wall and taping (i.e., SIPs tape), caulking or sealing of all joints and seams of panel joints (i.e., spline connections) shall be maintained to be considered as the air barrier. e) Penetrations and obstructions to the SIP shall be completely caulked and sealed. f) Insulation shall fill between the sheathing and the rear of electrical boxes and phone boxes. g) Insulation shall fill the entire cavity; or, an additional air barrier shall be installed inside the double wall or bump-out and in contact with the insulation so that the insulation fills the cavity formed with the additional air barrier. h) Entire double walls and framed bump-outs shall be air tight. INSULATED CONCRETE FORM (ICF) a) ICF systems are considered an air barrier; however, extension of the air barrier shall be made across all interconnections of window and door openings, and at all adjoining surfaces of exterior envelope assemblies of different materials (i.e., where ICF walls adjoin framed floors and roof/ceilings). b) Connections of ICF walls shall be grouted and sealed meeting manufacturer s specifications. All plumbing and wiring penetrations through the top and bottom of the ICF, and electrical boxes that penetrate the plane of the ICF shall be sealed. All gaps between interconnecting envelope assemblies of different materials shall have air barrier caulked, or sealed with minimally expansive foam or taped. c) Bottom connections of ICFs shall be sealed to the ground subfloor or slab, and above ground subfloor. d) Insulation shall uniformly fit across the plane of the wall and taping, caulking or sealing of all joints and seams of the ICF shall be maintained to be considered as the air barrier. e) Penetrations and obstructions to the ICF shall be completely caulked and sealed. f) Insulation shall fill between the sheathing and the rear of electrical boxes and phone boxes. g) Insulation shall fill the entire cavity; or, an additional air barrier shall be installed inside the double wall or bump-out and in contact with the insulation so that the insulation fills the cavity formed with the additional air barrier. h) Entire double walls and framed bump-outs shall be air tight. 10

11 Appendix A: Forms

CERTIFICATE OF VERIFICATION Quality Insulation Installation (QII) High Performance Wall Assembly Project Name: Enforcement Agency: Permit Number: Dwelling Address: City: Zip Code: General Requirements Wall stud cavities shall be caulked or foamed to provide a substantially air-tight envelope to the outdoors, attic, garage and crawl space. All 01 plumbing and wiring penetrations through the top and bottom plates and electrical boxes that penetrate the exterior sheathing shall be sealed. All gaps in the air barrier shall be caulked, taped, or sealed with minimally expansive foam. 02 Bottom plates of framed and non-framed assemblies shall be sealed to the ground subfloor or slab, and above ground subfloor. 03 Narrow spaces less than 1 inch in width at windows and door jambs, shall be filled with minimally expansive foam. 04 Narrow spaces less than 2 inches in width, such as between studs at building corners, and at the intersection of interior partition walls to exterior walls, shall be filled with insulation snuggly fitted in the space, or with minimally expansive foam. Hard to access wall stud cavities, such as corner channels, wall intersections, and behind tub/shower enclosures shall be insulated to the 05 proper R-value. In most cases this can only be completed prior to the installation of the tub/shower enclosure, the exterior sheathing, or the exterior stucco lath. 06 An air barrier shall be installed on the inside of the exterior wall(s) directly adjacent to the tub/shower enclosure. 07 Framing and bracing used for structural purposes shall be identified on plan documents with diagrams and/or design drawings. 08 Insulation shall be installed in a manner that restricts thermal bridging through the structural framing assembly. 09 Insulation shall be applied to fully enclose and/or adhere to all sides and ends of structural assembly framing that separate conditioned from unconditioned space. 10 The structural portions of assemblies shall be air-tight. 11 The HERS rater shall verify the installed thickness of the insulation in all assemblies and locations and shall ensure that insulation levels and installation integrity meet the R-value specified on the Certificate of Compliance, and all other required compliance documentation. 12 Verification Status: Pass - all applicable requirements are met; or Fail - one or more applicable requirements are not met. Enter reason for failure in corrections notes field below; or All N/A - This entire table is not applicable 13 Correction Notes: The responsible person s signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. Batt and Blanket Insulation 01 Batt and blanket insulation shall be correctly sized to fit snugly at the sides and ends. 02 Batt and blanket insulation shall be installed so that they will be in contact with the air barrier. 03 Where necessary, batt and blanket insulation shall be cut to fit properly - there shall be no gaps, nor shall the insulation be doubled-over or compressed. 04 When batt and blanket insulation are cut to fit a non-standard cavity, they shall be snugly fitted to fill the cavity without excessive compression. 05 Batt and blanket insulation shall be cut to butt-fit around wiring and plumbing, or be split (delaminated) so that one layer can fit behind the wiring or plumbing, and one layer fit in front. 06 Insulation shall uniformly fill the cavity side-to-side, top-to-bottom, and front-to-back. 07 Batt insulation shall fill the cavity by friction fitting, inset or face stapling of flanges of faced batts, or by other support methods as necessary. 08 Batt and blanket insulation shall be installed to fill the cavity and be in contact with the sheathing on the back and the wallboard on the front - no gaps or voids. 09 Batts with flanges that are inset stapled to the side of the stud must be flush with the face of the cavity (or protrude beyond) except for the portion that is less than two inches from the edge of the stud. 10 Insulation shall be placed between the sheathing and the rear of electrical boxes and phone boxes. Registration Number: Registration Date/Time: HERS Provider:

CERTIFICATE OF VERIFICATION Quality Insulation Installation (QII) High Performance Wall Assembly Project Name: Enforcement Agency: Permit Number: Dwelling Address: City: Zip Code: In cold climates, where water pipes may freeze (such as Climate Zones 2, 11-14 and 16) pipes shall have at least 1/2 of the insulation 11 between the water pipe and the outside surface of the exterior wall. If the pipe is closer to the exterior finish assembly layers, as much insulation as possible shall be placed between the pipe and the outside (without excessive compression), and remaining insulation shall be placed between the pipe and the interior assembly material. 12 Insulation shall fill the entire cavity; or, an additional air barrier shall be installed inside the double wall or bump-out and in contact with the insulation so that the insulation fills the cavity formed with the additional air barrier. 13 Entire double walls and framed bump-outs shall be air-tight. 14 Verification Status: Pass - all applicable requirements are met; or Fail - one or more applicable requirements are not met. Enter reason for failure in corrections notes field below; or All N/A - This entire table is not applicable 15 Correction Notes: The responsible person s signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. Loose Fill Insulation 01 Loose fill insulation shall be installed so that it will be in contact with the air barrier. 02 Loose fill insulation shall uniformly fill the cavity side-to-side, top-to-bottom, and front-to-back. 03 Loose fill wall insulation shall be installed to fit around wiring, plumbing, and other obstructions. 04 The installer shall certify on the Certificate of Installation forms that the manufacturer's minimum weight-per-square-foot requirement has been met. 05 Loose fill insulation shall fill between the sheathing and the rear of electrical boxes and phone boxes. In cold climates, where water pipes may freeze (such as Climate Zones 2, 11-14 and 16) pipes shall have at least 1/2 of the insulation 06 between the water pipe and the outside surface of the exterior wall. If the pipe is closer to the exterior finish assembly layers, as much insulation as possible shall be placed between the pipe and the outside (without excessive compression), and remaining insulation shall be placed between the pipe and the interior assembly material. 07 Loose fill insulation shall fill the entire cavity; or, an additional air barrier shall be installed inside the double wall or bump-out and in contact with the loose fill insulation so that the loose fill insulation fills the cavity formed with the additional air barrier. 08 Entire double walls and framed bump-outs shall be air-tight. 09 Verification Status: Pass - all applicable requirements are met; or Fail - one or more applicable requirements are not met. Enter reason for failure in corrections notes field below; or All N/A - This entire table is not applicable 10 Correction Notes: The responsible person s signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. Registration Number: Registration Date/Time: HERS Provider:

CERTIFICATE OF VERIFICATION Quality Insulation Installation (QII) High Performance Wall Assembly Project Name: Enforcement Agency: Permit Number: Dwelling Address: City: Zip Code: Rigid Board Insulation 01 Rigid board insulation shall be attached according to the manufacturer's specifications. 02 Rigid board insulation may be used as the air barrier provided it has been tested to conform to the air barrier performance conditions of the Standards. 03 Installation shall uniformly fit across the plane of the wall and taping and/or caulking of all joints and seams of the rigid board insulation shall be maintained to be considered as the air barrier. 04 Penetrations and obstructions to the rigid board insulation shall be completely caulked and sealed. 05 Rigid board insulation shall fill between the exterior sheathing and the rear of electrical boxes and phone boxes. 06 Rigid board insulation shall fill the entire cavity; or, an additional air barrier shall be installed inside the double wall or bump-out and in contact with the rigid board insulation so that the rigid board insulation fills the cavity formed with the additional air barrier. 07 Entire double walls and framed bump-outs shall be air-tight. 08 Verification Status: Pass - all applicable requirements are met; or Fail - one or more applicable requirements are not met. Enter reason for failure in corrections notes field below; or All N/A - This entire table is not applicable 09 Correction Notes: The responsible person s signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. Spray Polyurethane Foam (SPF) Insulation 01 02 03 04 05 06 07 08 09 The installer shall determine and the HERS rater shall verify that the manufacturer s nominal insulation thickness has been installed and certified and that all requirements of the Certificate of Verification have been met. The installer shall determine and the HERS rater shall verify that insulation is in substantial contact with the assembly air barrier. When SPF insulation is being used to provide air barrier control, the SPF insulation must cover and be in contact with the entire surface of the framing. SPF insulation shall be applied by SPF applicators trained and experienced in the use and maintenance of high-pressure, plural-component equipment. SPF applicators shall be certified by the SPF insulation manufacturer for the application of SPF insulation systems. SPF insulation shall be spray-applied to fully adhere to assembly framing within the construction cavity. When multiple layers of SPF material are applied, each foam lift (i.e. spray application) shall have adhesion at substrate and foam interfaces. SPF insulation shall not exhibit areas that: 1. Have voids or gaps in the uniformity of the insulation 2. Are extremely soft or spongy 3. Show the presence of liquid 4. Have blistering between lifts 5. Show differences in coloration of adjacent foam layers 6. Indicate the presence of other materials between lifts SPF insulation shall be installed in conformance with the manufacturer s specifications, recommendations and temperature/humidity limitations. Substrates to which SPF insulation is applied shall be secure and free of surface moisture, frost, grease, oils, dirt, dust or other contaminants that would adversely affect SPF adhesion. SPF insulation shall meet all provisions of the CBC Title 24, Parts 2 and 2.5. SPF shall be separated from occupied spaces by an approved thermal barrier, such as 0.5 inch gypsum wallboard or other approved material, or show equivalence through testing in accordance with CBC, Title 24, Part 2, Section 2603, and Part 2.5, Section R316. SPF insulation may be used as the air barrier provided it has been tested to conform to the air barrier performance conditions of the Standards. SPF insulation shall be kept away from combustion appliance flues in accordance with flue manufacturers' installation instructions or labels on the flue for clearance. Registration Number: Registration Date/Time: HERS Provider:

CERTIFICATE OF VERIFICATION Quality Insulation Installation (QII) High Performance Wall Assembly Project Name: Enforcement Agency: Permit Number: Dwelling Address: City: Zip Code: SPF insulation shall be applied to provide an air-tight envelope to the outdoors and between adjoining cavity surfaces of conditioned and 10 unconditioned space, such as the: attic, garage, and crawl space. Special attention shall be paid to plumbing and wiring penetrations through the top plates and bottom plate framing, and electrical boxes that penetrate the sheathing and the sheathing seal to the top and bottom plate framing. 11 SPF insulation installation shall uniformly cover the cavity side-to-side and end-to-end and shall be installed to cover and form an air barrier on the framing at the top, bottom and sides of each cavity. 12 Non-standard width cavities shall be filled with SPF insulation at a depth consistent with the SPF thickness required to achieve the specified R-value. 13 SPF insulation shall be applied to fully seal around wiring and plumbing. 14 SPF insulation shall be applied to fully seal between the sheathing and the rear of electrical boxes and telephone boxes. In cold climates, where water pipes may freeze (Climate Zones 14 and 16), pipes shall have at least 2/3 of the insulation between the water 15 pipe and the outside surface of the exterior wall. If the pipe is near the exterior finish assembly layers, as much insulation as possible shall be placed between the pipe and the exterior assembly material. Pass - all applicable requirements are met; or 16 Verification Status: Fail - one or more applicable requirements are not met. Enter reason for failure in corrections notes field below; or All N/A - This entire table is not applicable 17 Correction Notes: The responsible person s signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. Structural Insulated Panel (SIP) Insulation 01 SIP systems are considered an air barrier; however, extension of the air barrier shall be made across all interconnections of panels, at window and door openings, and at all adjoining surfaces of different panel areas (i.e., where SIP walls adjoin the floor and roof/ceiling). Connections of wall panels shall be sealed, caulked, foamed, or taped (i.e., SIP tape) to provide a substantially air-tight envelope to the 02 outdoors, attic, garage and crawl space. All plumbing and wiring penetrations through the top and bottom of panels, and electrical boxes that penetrate the SIP sheathing shall be sealed. All gaps in the air barrier shall be caulked, or sealed with minimally expansive foam or taped (i.e., SIP tape). 03 Bottom connections of wall panels shall be sealed to the ground subfloor or slab, and above ground subfloor. 04 Insulation shall uniformly fit across the plane of the wall and taping (i.e., SIPs tape), caulking or sealing of all joints and seams of panel joints (i.e., spline connections) shall be maintained to be considered as the air barrier. 05 Penetrations and obstructions to the SIP shall be completely caulked and sealed. 06 Insulation shall fill between the sheathing and the rear of electrical boxes and phone boxes. 07 Insulation shall fill the entire cavity; or, an additional air barrier shall be installed inside the double wall or bump-out and in contact with the insulation so that the insulation fills the cavity formed with the additional air barrier. 08 Entire double walls and framed bump-outs shall be air tight. 09 Verification Status: Pass - all applicable requirements are met; or Fail - one or more applicable requirements are not met. Enter reason for failure in corrections notes field below; or All N/A - This entire table is not applicable 10 Correction Notes: The responsible person s signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. Registration Number: Registration Date/Time: HERS Provider:

CERTIFICATE OF VERIFICATION Quality Insulation Installation (QII) High Performance Wall Assembly Project Name: Enforcement Agency: Permit Number: Dwelling Address: City: Zip Code: Insulated Concrete Form (ICF) Insulation ICF systems are considered an air barrier; however, extension of the air barrier shall be made across all interconnections of window and 01 door openings, and at all adjoining surfaces of exterior envelope assemblies of different materials (i.e., where ICF walls adjoin framed floors and roof/ceilings). Connections of ICF walls shall be grouted and sealed meeting manufacturer's specifications. All plumbing and wiring penetrations through 02 the top and bottom of the ICF, and electrical boxes that penetrate the plane of the ICF shall be sealed. All gaps between interconnecting envelope assemblies of different materials shall have air barrier caulked, or sealed with minimally expansive foam or taped. 03 Bottom connections of ICFs shall be sealed to the ground subfloor or slab, and above ground subfloor. 04 Insulation shall uniformly fit across the plane of the wall and taping, caulking or sealing of all joints and seams of the ICF shall be maintained to be considered as the air barrier. 05 Penetrations and obstructions to the ICF shall be completely caulked and sealed. 06 Insulation shall fill between the sheathing and the rear of electrical boxes and phone boxes. 07 Insulation shall fill the entire cavity; or, an additional air barrier shall be installed inside the double wall or bump-out and in contact with the insulation so that the insulation fills the cavity formed with the additional air barrier. 08 Entire double walls and framed bump-outs shall be air tight. 09 Verification Status: Pass - all applicable requirements are met; or Fail - one or more applicable requirements are not met. Enter reason for failure in corrections notes field below; or All N/A - This entire table is not applicable 10 Correction Notes: The responsible person s signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. Registration Number: Registration Date/Time: HERS Provider:

CERTIFICATE OF VERIFICATION Quality Insulation Installation (QII) High Performance Wall Assembly Project Name: Enforcement Agency: Permit Number: Dwelling Address: City: Zip Code: DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Company: Address: City/State/Zip: Date Signed: CEA/HERS Certification Information (if applicable): Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Verification is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. BUILDER OR INSTALLER INFORMATION AS SHOWN ON THE CERTIFICATE OF INSTALLATION Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Responsible Builder or Installer Name: HERS PROVIDER DATA REGISTRY INFORMATION Sample Group Number (if applicable): CSLB License: Dwelling Test Status in Sample Group (if applicable): HERS RATER INFORMATION HERS Rater Company Name: Responsible Rater Name: Responsible Rater Certification Number w/ this HERS Provider: Responsible Rater Signature: Date Signed: Registration Number: Registration Date/Time: HERS Provider: