K.S. Rawat 1, H. Khulve 2, A.K. Pratihar 3 1,3 Department of Mechanical Engineering, GBPUAT, Pantnagar , India

Similar documents
Working fluid selection of low grade heat geothermal Organic Rankine Cycle (ORC)

Investigations of N 2 O Transcritical Refrigeration Cycle Using Dedicated Mechanical Subcooling. Sanjeev Kumar 1 and Dr. D.K.

EXPERIMENTAL STUDY ON THE REPLACEMENT OF HFC-R134A BY HYDROCARBONS MIXTURE IN AUTOMOTIVE AIR CONDITIONER. Skudai, Johor, Malaysia 81310

Organic Rankine Cycle and Its Working Fluid Selection-A Review

Lecture No.3. The Ideal Reheat Rankine Cycle

Refrigeration Cycle. Definitions , , 11-46, 11-49,

Cool Producing Systems Based on Burning and Gasification of Biomass

Honeywell Refrigerants Improving the Uptake of Heat Recovery Technologies 1

Performance of a Combined Organic Rankine Cycle and Vapor Compression Cycle for Heat Activated Cooling

Improvement of distillation column efficiency by integration with organic Rankine power generation cycle. Introduction

a. The power required to drive the compressor; b. The inlet and output pipe cross-sectional area. [Ans: kw, m 2 ] [3.34, R. K.

ORGANIC RANKINE CYCLE AS EFFICIENT ALTERNATIVE TO STEAM CYCLE FOR SMALL SCALE POWER GENERATION

ANALYSIS OF REFRIGERATION CYCLE PERFORMANCE WITH AN EJECTOR

MULTI-OBJECTIVE OPTIMIZATION OF TURBO-EXPANDER IN ORGANIC RANKINE CYCLE SYSTEM

Analysis of Low Temperature Organic Rankine Cycles for Solar Applications

Low-Grade Waste Heat Recovery for Power Production using an Absorption-Rankine Cycle

Feedwater Heaters (FWH)

Comparison of micro gas turbine heat recovery systems using ORC and trans-critical CO 2 cycle focusing on off-design performance

Low temperature cogeneration using waste heat from research reactor as a source for heat pump

Consider a simple ideal Rankine cycle with fixed turbine inlet conditions. What is the effect of lowering the condenser pressure on

Review Questions for the FE Examination

DEVELOPMENT OF TWIN PISTON EXPANDER WITH SOLENOID VALVE FOR ORGANIC RANKINE CYCLE

OUTCOME 2 TUTORIAL 2 STEADY FLOW PLANT

CO 2. transcritical refrigeration cycles: potential for exploiting waste heat recovery with variable operating conditions

Investigation of Separator Parameters in Kalina Cycle Systems

Exergy analysis of transcritical carbon dioxide refrigeration cycle with an expander

ENERGY RECOVERY IMPROVEMENT USING ORGANIC RANKINE CYCLE AT COVANTA S HAVERHILL FACILITY

LIFE CYCLE COST ANALYSIS OF WASTE HEAT OPERATED ABSORPTION COOLING SYSTEMS FOR BUILDING HVAC APPLICATIONS

Chapter 6 THE SECOND LAW OF THERMODYNAMICS

IOP Conference Series: Earth and Environmental Science PAPER OPEN ACCESS

Revue des Energies Renouvelables Spécial ICT3-MENA Bou Ismail (2015) Numerical study of a single effect ejector-absorption cooling system

AN EXERGY COST ANALYSIS OF A COGENERATION PLANT

TransPacific Energy Advantage: Case Studies

DESIGN ANALYSIS OF A REFRIGERATED WAREHOUSE USING LNG COLD ENERGY

Mechanics, Energy, Environment

Waste Heat Recovery at Compressor Stations

MCG THERMODYNAMICS II. 22 April 2008 Page 1 of 7 Prof. W. Hallett

Efficiency improvement of steam power plants in Kuwait

Conceptual Design of Nuclear CCHP Using Absorption Cycle

EFFECT OF AMBIENT TEMPERATURE, GAS TURBINE INLET TEMPERATURE AND COMPRESSOR PRESSURE RATIO ON PERFORMANCE OF COMBINED CYCLE POWER PLANT

Waste Heat Recovery of IC Engine Using VAR System

Energy And Exergy Analysis Of Fully Condensing Steam Turbine At Various Steam Load Condition

Design and Optimization of Kalina Cycle for Geothermal Energy in Kenya

Hydrogen oxygen steam generator integrating with renewable energy resource for electricity generation

Exergy Analysis of a Power Plant in Abu Dhabi (UAE)

Pinch Analysis for Power Plant: A Novel Approach for Increase in Efficiency

Multi-Variable Optimisation Of Wet Vapour Organic Rankine Cycles With Twin-Screw Expanders

CONTROL VOLUME ANALYSIS USING ENERGY. By Ertanto Vetra

Refrigeration Kylteknik

Estimation of Boil-off-Gas BOG from Refrigerated Vessels in Liquefied Natural Gas Plant

ENHANCEMENT OF COEFFICIENT OF PERFORMANCE IN VAPOUR COMPRESSION REFRIGERATION CYCLE

R442A (RS-50) Features and uses of the R442A (RS-50) Lubricants TECHNICAL DATA SHEET. Barcelona Girona Madrid Zaragoza

A thesis submitted for the degree of Doctor of Philosophy. Liang Li, M.Sc.

Efficiency enhancement of the ocean thermal energy conversion system with a vapor vapor ejector

Energy Analysis of Supercritical Water and Ammonia (Kalina) Power Cycle

Energy and Buildings

Thermodynamic Comparison of Organic Rankine Cycles Employing Liquid-Flooded Expansion or a Solution Circuit

ES Analysis of Performance of Direct Dry Cooling. for Organic Rankine Cycle Systems

A Design of the Organic Rankine Cycle for the Low Temperature Waste Heat

Heat recovery from diesel engines and gas turbines

Thermally operated mobile air-conditioning system

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM IV (ME-41, 42,43 & 44)] QUIZ TEST-1 (Session: )

Zero-ODP, Low GWP, Non-Flammable Working Fluid for Organic Rankine Cycles: HFO-1336mzz-Z

POWER RECOVERY IN FLOATING LNG REGASIFICATION PLANTS

Modeling and Investigation of Refrigeration System Performance with Two-Phase Fluid Injection in a Scroll Compressor

Refrigerant Selection Considerations


Application of Two Stage Ejector Cooling System in a Bus

Solar Absorption Aqua-Ammonia Absorption system simulation base on Climate of Malaysia

Application of Taguchi s Methods for Optimizing Organic Rankine Cycle for Recovering Low Grade Industrial Waste Heat

Supercritical Fluid Parameters in Organic Rankine Cycle Applications

Comparison of combined heat and power systems using an organic Rankine cycle and a low-temperature heat source

THE CHOICE OF WORKING FLUID: (AND AN EFFICIENT TURBINE) Ennio Macchi Department of Energy - Politecnico di Milano

PureCycle 200 Heat-to-Electricity Power System

COMBINED CYCLE OPPORTUNITIES FOR SMALL GAS TURBINES

Waste Heat Recovery with Organic Rankine Cycle Technology

Performance of a Gas Turbine Power Plant

MECHANICAL ENGINEERING THERMAL AND FLUID SYSTEMS STUDY PROBLEMS

Hydrocarbon Refrigerant Performance in UAE Air-Cooled Chillers

OVERFED EVAPORATORS AND PARALLEL COMPRESSION IN COMMERCIAL R744 BOOSTER REFRIGERATION SYSTEMS AN ASSESSMENT OF ENERGY BENEFITS

Thermodynamic analysis on post combustion CO 2 capture of natural gas fired power plant

Analysis of carbon dioxide emission of gas fuelled cogeneration plant

A Simplified Thermal Model for a CO2 Compressor

Utilization of Abandoned Coal Mines as a Low Enthalpy Geothermal Resource and Subsequent Energy Exploitation

Performance Assessment of Large Vapor Absorption System

Organic Rankine Cycles

AN ABSTRACT OF THE THESIS OF

Thermodynamic analysis of a regenerative gas turbine cogeneration plant

THERMODYNAMIC ANALYSIS OF R134A DMAC VAPOR ABSORPTION REFRIGERATION (VAR) SYSTEM

Validating a Thermodynamic Model of the Otahuhu B Combined Cycle Gas Turbine Power Station

Exergy Analysis of Absorption Power Cycle Depending on Source Temperatures

Secondary Systems: Steam System

Using Carbon Dioxide in a Transcritical Vapor Compression Refrigeration Cycle

3.17. PROCESS INTEGRATION AND PINCH TECHNOLOGY

Secondary Coolant Systems for Supermarkets

In this lecture... Solve problems related to First law of thermodynamics for closed and open systems Heat engines Refrigerators and heat pumps

LECTURE-15. Ideal Reverse Brayton Cycle. Figure (6) Schematic of a closed reverse Brayton cycle

Magnetically Coupled Submerged Cryogenic Pumps and Expanders for Ammonia Applications

OPTIMIZATION OF AN ORGANIC RANKINE CYCLE IN ENERGY RECOVERY FROM EXHAUST GASES OF A DIESEL ENGINE

Performance of Organic Rankine Cycle Using Biomass As Source of Fuel

Transcription:

Thermodynamic Analysis of Combined ORC-VCR System Using Low Grade Thermal Energy K.S. Rawat 1, H. Khulve 2, A.K. Pratihar 3 1,3 Department of Mechanical Engineering, GBPUAT, Pantnagar-263145, India 2 Department of Mechanical Engineering, RIMT, Bareilly-243407, India Abstract The world is facing energy and environmental challenges due to population growth and economy development. The utilization of renewable energy can significantly contribute to reduction in consumption of conventional energy and environmental pollution. Low grade thermal energy can be utilized in organic Rankine cycle driven vapour compression refrigeration system (combined ORC-VCR) to produce refrigeration effect. Low grade renewable energy can be obtain from the source such as solar, geothermal and waste heat of industries. This work deals with thermodynamic analysis of combined ORC- VCR system with low GWP working fluids. In this paper four hydrocarbons; butane (), iso-butane (a), propane () and propylene () are used as a working fluid to analyze the effect of various operating parameters of combined organic Rankine cycle drive vapour compression refrigeration system and evaluated to find the best candidate for the system. It is found that the butane () gives the highest overall COP of combined system as the boiler exit temperature is between 60 to 90 0 C, the condenser temperature 30 to 55 0 C and evaporator temperature range -15 to 15 0 C. At boiler exit temperature 90 0 C, the butane () gives maximum overall system COP is 0.4696. Keywords Organic Rankine Cycle; Vapour Compression Refrigeration Cycle; Low Grade Energy; Hydrocarbons; Low GWP I. INTRODUCTION World is facing energy crisis and environmental challenges due to the rapid growth of population and industrial development. The utilization of low-grade thermal energy can significantly contribute to reduce the conventional energy consumption and meanwhile to relieve the environmental pollution. In this respect, thermally activated cooling technologies as methods to recover the low-grade thermal energy have gained considerable interest [1]. The thermally activated refrigeration can be fulfilled by sorption (adsorption and absorption), thermoelectric and Rankine cycle powered vapour compression refrigeration (VCR) systems. Comparing with the others, the last one has flexibility associated with the mechanical power delivered by an expander, which makes the system to continuously utilize the thermal energy throughout the year [2]. The temperature of heat sources below 100 C is called low grade heat because a Rankine cycle using water cannot work efficiently at such low temperatures. Statistical data indicates that 50 % or more of total heat generated by industry is low-grade waste heat [3]. Generally, low grade thermal energy produced during industrial processes as well as natural ones like such as geothermal heating, ocean heating, solar heating and biomass combustion etc. is discarded in the atmosphere as waste heat. This thermal pollution has become major environmental concern [4]. Fig. 1 shown [5] that contribution of biomass organic Rankine cycle (ORC) is a highest and geothermal energy which used is the most significant one is in second position currently. Waste heat recovery in different industries which is in third place and solar ORC still has only 1% of ORC market due to lack of awareness. But this technology has also a huge potential. Fig. 1. ORC market share for different heat sources 515

A. Organic Rankine Cycle Organic Rankine cycle is a simple Rankine power cycle in which working fluid are mainly an organic fluid instead of water. Organic fluids are the high molecular mass fluids with lower degree of boiling temperature in comparison with water. For low-grade heat recovery systems, the working fluid used is mainly an organic fluid. The main reason for this is that these always have a lower heat of vaporization than water and hence can be vaporized more easily with low-grade heat. Such characteristics make ORC favourable for applications of low temperature heat recovery. ORC is preferable for the low-grade thermal energy utilization due to which it has a good efficiency over a wide temperature range [6]. ORC has several advantages over steam cycle. It is known that working fluids in ORC has higher molecular weight than water. This will increase mass flow rate of fluid for the same sizes of turbine. More mass flow rates will give better turbine efficiencies and less turbine losses [7]. Many studies had been carried out on Combined ORC-VCR systems with various working fluids: chlorofluorocarbons (CFCs), hydro chloro fluoro carbons (HCFCs) and hydro fluoro carbons (HFCs) [8-10]. However, these working fluids have negative impact on environment [11], so various hydrocarbons (natural fluids) are recognized as possible alternatives to the CFCs, HCFCs and HFCs [12]. Hydrocarbon refrigerants (,, a & ) are natural, nontoxic refrigerants that have excellent thermo-physical properties, no ozone depleting properties (zero ODP) and absolutely low global warming potential (GWP). TABLE I: PROPERTIES OF THE FOUR HYDROCARBONS M NBP T crit p crit Refrigerant Chemical Formula (kg/mol) ( 0 C) ( 0 C) (kpa) Safety group C 3 H 8 44.10-42.09 96.68 4247 A3 C 4 H 10 58.12-0.55 151.98 3796 A3 a C 4 H 10 58.12-11.67 134.67 3640 A3 C 3 H 6 42.08-47.69 92.42 4665 A3 Hydrocarbons are highly flammable as they are in A3 safety group but Venkatarathnam et al. (2012) and Palm (2008) indicated that with adequate safety precautions and regulations, the flammability will not be a major problem in the usage of hydrocarbons [13-14]. II. COMBINED ORC-VRC SYSTEM DESCRIPTION The schematic diagram of the ORC VCR system is shown in Fig. 2. This system consists of two cycles, first is ORC identified as 1-2-3-4-1 and the other is VCR cycle as 5-6-3-7-5. This system uses the same working fluid for both the power and refrigeration cycles. In this system, expander of the organic Rankine cycle and the compressor of the vapour compression refrigeration cycle are directly coupled through shaft. The mechanical power delivered from the organic Rankine cycle through the expander is just enough to drive the compressor and boiler feed pump and the organic Rankine cycle and vapour compression refrigeration cycle share a common condenser. Fig. 2. Schematic diagram of the Combined ORC-VCR system 516

The T-s diagram of the organic Rankine cycle drive vapour compression refrigeration cycle is shown in Fig. 3. Accordingly, the various processes of the system are presented as follows: 1 2 : actual expansion in the expander; 1 2s : isentropic expansion in the expander; 2 3 : heat rejection (condensation) in the ORC; 3 4 : actual pumping work; 3 4s : isentropic pumping work; 4 1 : heat addition in the boiler; 3 7 : isenthalpic expansion in the throttle valve; 7 5 : heat absorption (evaporation) in the VCR cycle; 5 6 : actual compression in the compressor; 5 6s : isentropic compression in the compressor; 6 3 : heat rejection (condensation) in the VCR cycle. Fig. 3.T-s diagram of the combined ORC-VCR system III. THERMODYNAMIC ANALYSIS Thermodynamic analysis of ORC-VCR system has been carried out in this work. In order to simplify the analysis, some assumptions are made as follows: steady-state conditions are considered in all components; heat and friction losses in the system is neglected; the condenser has a given subcooling of 3 0 C to prevent boiler feed pump cavitations; the working fluid leaving the boiler and evaporator is saturated. The thermo-physical properties of the hydrocarbon refrigerants were calculated using a software package called an Engineering Equation Solver (EES).A major feature of EES is the high accuracy thermodynamic and transport property database that is provided for hundreds of substances in a manner that allows it to be used with the equation solving capability [15]. A. Governing Equations Based on these assumptions and referring to the ORC VCR system presented in Fig. 2 and Fig. 3, the mathematical model for the system is given below. For the organic Rankine cycle (1) (2) The thermal efficiency of the ORC is defined as (3) (4) (5) For vapour compression refrigeration cycle 517

(6) (7) The COP of the VCR cycle is expressed as (8) (9) (10) The working fluid mass flow rate of per KW cooling capacity in ORC-VCR system: The expansion ratio across the expander and the compression ratio across the compressor, which are proportional to the expander and compressor sizes, respectively: (11) (12) IV. RESULTS AND DISCUSSION The input parameters and boundary conditions are presented in Table II. The maximum boiler exit temperature is set to 90 0 C. (13) TABLE II: INPUT PARAMETER AND BOUNDARY CONDITIONS Parameters Value Range Working fluid mass flow rate in ORC 1 kg/s - Evaporator temperature 5 0 C -15 to15 0 C Boiler exits temperature 80 0 C 60 to 90 0 C Condensation temperature 40 0 C 30 to 55 0 C Expander isentropic efficiency 0.80 0.60 to 0.90 Compressor isentropic efficiency 0.75 0.60 to 0.90 Boiler feed pump isentropic efficiency 0.75 - A. Effect of Boiler Exit Temperature Fig. 4 shows the Variation of COP overall and MkW with boiler exit temperature. It has been observed from the figure that COP overall of the combined ORC-VCR system increases with increase in boiler exit temperature. Performance of the system is 518

COP OVERALL 0.55 0.5 0.45 0.4 0.35 0.3 0.25 a a 2 x 10-2 2 x 10-2 MKW[kg/(s-KW)] 0.2 8 x 10-3 0.15 6 x 10-3 60 65 70 75 80 85 90 BOILER EXIT TEMPERATURE[ 0 C] Fig. 4. Variation of COP overall and MkW with boiler exit temperature. best with butane () than follow by a, and over the entire range (60 to 90 o C) of the boiler exit temperature. The maximum overall thermal efficiency in the case of is due to the higher critical temperature. So it can be concluded that higher critical temperature organic fluids may leads to better performance. Fig. 4 also shows that the MkW decreases with the boiler exit temperature for the four hydrocarbons, and the minimum is seen in the case of within the temperature range, followed by a, and. 4 3.5 3 a EPR 2.5 2 1.5 1 60 65 70 75 80 85 90 BOILER EXIT TEMPERATURE[ 0 C] Fig. 5. Variation of EPR with boiler exit temperature. COPOVERALL 0.8 0.7 0.6 0.5 0.4 0.3 0.2 a a 0.04 0.035 0.03 0.025 0.02 0.015 MKW[kg/(s-KW)] 0.1 0.01 0 0.005 30 35 40 45 50 55 CONDENSER TEMPERATURE[ 0 C] Fig. 6. Variation of COP overall and MKW with condensation temperature Fig. 5 shows the variation in the EPR with boiler exit temperature. It can be seen in the figure that EPR increases with increase in boiler exit temperature and at 90 o C its value approximately doubles that at 60 o C for four hydrocarbons. It is found that higher value of EPR is in the case of, followed by a, and, except for those with the boiler exit temperature between 85 and 90 o C. However, the differences among the EPR values for these hydrocarbons are very small. B. Effect Of Condenser Temperature Fig. 6 shows the Variation of COP overall and MkW with condenser temperature. It has been observed from the figure that COP overall of the combined ORC-VCR system decreases with increase in condenser temperature. Performance of the system is best with butane () than follow by a, and over the entire range (30 to 55 o C) of the condenser temperature. Fig. 6 also shows 519

that the MkW increases with increase in condenser temperature for the four hydrocarbons, and the minimum is seen in the case of within the temperature range, followed by a, and. EPR 5 4.75 4.5 4.25 4 3.75 3.5 3.25 3 2.75 2.5 2.25 2 1.75 1.5 a a 1.5 30 35 40 45 50 55 CONDENSER TEMPERATURE[ 0 C] Fig.7. Variation of EPR and CMR with condensation temperature 5 4.5 4 3.5 3 2.5 2 CMR 0.8 0.7 a a 3 x10-2 0.6 2 x10-2 COP OVERALL 0.5 0.4 0.3 0.2 0.1 2 x10-2 1 x10-2 1 x10-2 MKW[kg/(s-KW)] 0 5 x10-3 -15-10 -5 0 5 10 15 EVAPORATION TEMPERATURE[ 0 C] Fig. 8. Variation of COP overall and MKW with evaporation temperature 8 7 6 5 a CMR 4 3 2 1 0-15 -10-5 0 5 10 15 EVAPORATION TEMPERATURE[ 0 C] Fig. 9. Variation of CMR with evaporation temperature It is observed from Fig.7 that as the condenser temperature increase, EPR across the expander in the ORC decreases. The differences between EPR values for the four hydrocarbons are small and these differences are further reduced at a higher condenser temperature. However CMR increases with increase in condenser temperature and the differences between CMR values for the four hydrocarbons are significant and these differences are further increased at a higher condenser temperature. C. Effect Of Evaporator Temperature Fig. 8 shows the effect of evaporation temperature on COP overall and MkW of the combined ORC-VRC system. It has been observed from the fig. 8 that increase in evaporator temperature increases the COP overall of the ORC VCR system and decreases the MkW of the ORC VCR system. Performance with is best and MkW for is lowest. Fig. 9 shows the effect of evaporation temperature on CMR. It can be shown in the fig. 9 increase in evaporator temperature, decreases compression ratio across the compressor in the VCR cycle. 520

Nomenclature COP VCR : refrigeration cycle coefficient of performance - COP overall : overall system coefficient of performance - CMR : compression ratio in compressor - EPR : expansion ratio in expander - MkW : working fluid mass flow rate of per kw cooling capacity (kg/(s-kw)) ORC : organic Rankine cycle - VCR : vapour compression refrigeration - W comp : compressor work input (kw) m ORC : power cycle mass flow rate (kg/s) m VCR : refrigeration cycle mass flow rate (kg/s) W pump : pump power consumption (kw) W net : network output (kw) W exp : expander work output (kw) P critical : critical pressure (kpa) Q evap : evaporator cooling capacity (kw) Q boiler : boiler heat input (kw) h : enthalpy (kj/kg) t critcal : critical temperature ( 0 C) v 1 : specific volume of working fluid at expander inlet (m 3 /kg) v 2 : specific volume of working fluid at expander outlet (m 3 /kg) V. CONCLUSIONS Thermodynamic analysis is the key tool to study the performance of ORC-VCR system. Thermodynamic analysis is used to find out the vital parameters affecting the system performance. In this work thermodynamic analysis of combined ORC-VCR system using hydrocarbon refrigerants (, a, and ) has been carried out which leads to following conclusions: Overall COP of the combined ORC-VRC system increases with increase in, boiler exit temperature and evaporator temperature. However, performance decreases with increase in condenser temperature. MkW of the combined ORC-VRC system decreases with increase in, boiler exit temperature and evaporator temperature. However value of MkW increases with increase in condenser temperature. EPR across the expander in the Organic Rankine Cycle increases with increase in boiler exit temperature and decreases with condenser temperature. CMR across the compressor in the vapour compression refrigeration cycle increases with increase in condenser temperature and decreases with evaporator temperature. The results show that each parameter has similar effects on the performance of the ORC VCR system using different hydrocarbon refrigerants. From the analysis it is concluded that (butane) is most promising working fluid in combined ORC-VCR system. REFERENCES [1] Deng J., Wang R.Z., Han G.Y., 2011, A Review of Thermally Activated Cooling Technologies for Combined Cooling, Heating and Power Systems, Progress in Energy and Combustion Science 37: 172 203. [2] Wang et al., 2011, Performance of a Combined Organic Rankine Cycle and Vapour Compression Cycle for Heat Activated Cooling, Energy 36: 447 458. 521

[3] Hung T.C., Shai T. Y. and Wang S. K., 1997, A Review of Organic Rankine Cycle for the Recovery of Low Grade Waste Heat, Energy 22: 661-667. [4] Declaye S., 2009, Design, Optimization and Modeling of an Organic Rankine Cycle for Waste Heat Recovery, Master Thesis, Electromechanical Engineer, University of Liege: 1-92. [5] Quoilin, S., 2007, Experimental Study and Modeling of a Low Temperature Rankine Cycle for Small Scale Cogeneration, Master Thesis, University of Liege: 1-129 [6] Tchanche B.F., Lambrinos G., Frangoudakis A., 2011. Low-Grade Heat Conversion into Power using Organic Rankine Cycles A Review of Various Applications, Renewable and Sustainable Energy Reviews 15: 3963 3979. [7] Drescher U., Bruggemann D., 2007, Fluid Selection for the Organic Rankine Cycle (ORC) in Biomass power and Heat Plants, Applied Thermal Engineering 27: 223 228. [8] Dubey M., Rajput S.P.S., Nag P.K., Misra R.D., 2010, Energy analysis of a coupled power - refrigeration cycle, Journal of Power Energy 224: 749-759. [9] Baik Y.J., Kim M., Chang K., Lee Y.S., Yoon H.K., 2013, A Comparative Study of Power Optimization in Low-Temperature Geothermal Heat Source Driven R125 Transcritical Cycle and HFC Organic Rankine Cycles [10] Aphornratana S., Sriveerakul T., 2010, Analysis of a Combined Rankine-Vapour Compression Refrigeration Cycle, Energy Conversion and Management 51: 2557-2564. [11] Calm J.M., 2008, The Next Generation of Refrigerants Historical Review, Considerations, and Outlook. International Journal of Refrigeration 31: 1123 1133. [12] Granryd E., 2001, Hydrocarbons as Refrigerants An Overview, International Journal of Refrigeration 24: 15 24. [13] Venkatarathnam G., Murthy S.S., 2012, Refrigerants for Vapour Compression Refrigeration Systems, Resonance 17: 139 162 [14] Palm B., 2008, Hydrocarbons as Refrigerants in Small Heat Pump and Refrigeration Systems A Review, International Journal of Refrigeration 31: 552 563. [15] EES: Engineering Equation Solver, 2014. fchart Software Inc. [16] Arora C.P., 2012, Refrigeration and Air Conditioning, 3 rd edition New Delhi: Tata McGraw Hill. [17] Cengel Y.A., Boles M.A., 2009, Thermodynamics: an Engineering Approach, 6 th edition New Delhi: Tata McGraw Hill. 522