Portable Emissions Measurement System (PEMS) for nanoparticle counting and classification.

Similar documents
Fine particle measuring system

Multi-function VAC measuring instrument

GAS 3050P NDIR FLUE GAS

testo 350 M testo 350 XL

Product data sheet Palas Condensation particle counter UF-CPC 100

TECHNICAL DATA SHEET

testo 330 Flue gas analysis with increased convenience and safety

Compact flue gas analyser: testo 300 M-I

To: PMP Working Group From: Chris Parkin

The Fast and Robust Flue Gas Measuring Instrument for All Important Parameters

COMBIMASS. Technical Data COMBIMASS GA-m / GA-e Version

Using the PPM2 Portable Trace Moisture Transmitter

testo 340 Speed, power & precision in industrial combustion analysis.

New Measurement Engineering For Monitoring Emissions In Industry

Humidity/temperature measuring instrument

Particle Measurement Programme

EUROλYZER STx. Flue Gas Analyzer. BlueLine

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Flue gas analyzer. We measure it. testo 310 Flue gas analysis the easy way. Robust design for daily use. Battery lifetime up to 10 hours

Combustion Laboratory Unit C492

Online Gas Analyzer / Monitor

Measurement & Analytics Measurement made easy. AlSCAN TM and AlSCAN TM Argon Hydrogen analysis in liquid aluminum

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

TARGAS-1. Portable Photosynthesis System. Photosynthesis Soil Respiration Canopy Assimilation Environmental Monitoring

Gas concentrations in the air

Explore the future of osmometry. Multi-Sample Micro-Osmometer

CHAPTER 6 : GAS SAMPLING SYSTEMS

Instruction Manual Dräger MSI EM200-s

Online data sheet MCS100E HW-C CEMS SOLUTIONS

Flue gas analyser. We measure it. testo 327 The special class entry instrument. Simple menu structure

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

Sampling method for particle measurements of vehicle exhaust

MMEA D Results of the feasibility studies for combustion and diesel exhaust gas measurements

Hydrant Pressure Monitoring Five of the most popular uses of Telog s HPR-31, hydrant pressure recorder, are:

WEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month

MEASUREMENT OF BRAKE WEAR EMISSIONS BY THE ENGINE EXHAUST PARTICLE SIZER (EEPS) SPECTROMETER AND OPTICAL PARTICLE SIZER (OPS)

Model BF 260 Incubators Avantgarde.Line with forced convection

Flue gas analysis brilliantly easy: testo 350

Model BF 720 Incubators Avantgarde.Line with forced convection

FIDAS FINE DUST MONITORING SYSTEMS. Fidas the world s only certified optical fine dust measurement system with single particle analysis for PM 2.

TURBIDITY TB 300 IR TB 210 IR TB 250 WL. General Catalogue April 2015

Instruction Manual HI Portable ph/ec/tds/ C Meters

TVOC Heated FID VE 7

EBI 10 High Precision Wireless Data Loggers

HyPM-HD POWER MODULES. for light and heavy duty mobility. HyPM. The industry benchmark for durable, zero emission mobility

The Leader in Performance Indoor Air Quality Measurements

SPECTRO XRF Report. SPECTRO xsortxhh03. Analysis of Solid Metal Samples. Summary

MRU Instruments, Inc. Houston, Texas Tel.: (844) (Toll Free)

ENGLISH Datasheet JIS Miniature Thermocouple Connector In-Line Plugs Types K, J, T, E, R/S & B (JIS Colour Code)

Melting Point M-565 Technical data sheet

Epson Solutions for Financial Institutions

Fpollutant-free zero air for analytical

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

FLUXUS F601. Portable, quick and reliable. Clamp-on ultrasonic flow meter. Measure from outside what's flowing inside

Carbon / Sulfur Analyzers

SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed

Sensor unit MC2 for toxic gases and oxygen with analog output

For Safe and Delicious Water

The Applications and Reference Design of Railway Rolling Stock in Transportation Systems 1

FoodScan for meat. Dedicated Analytical Solutions

TSI Model 3063 Thermal Mass Flowmeter

12 Temperature measurement SCT analogue

Particle Measurement Programme (PMP) Light-duty Inter-laboratory Correlation Exercise (ILCE_LD) Final Report

ProFoss for in-line process analysis of dairy powder

GreenLine 8000 GAS ANALYSIS. Portable Industrial Combustion & Emission Analyser O 2 CO 2 CO CO% SO 2 CH X Y NO 2 HS 2

It s All a Matter of TechNiQ. NiQ: Our latest generation of energy-saving motors.

Faraday efficiency and energetic efficiency of a PEM electrolyser

tempmate. -GS Stay Online and Well-Informed to Avoid Unpleasant Surprises: Cold Chain Monitoring 4.0

YSI 2900 Series Biochemistry Analyzers BIOPROCESS FOOD & BEVERAGE BIOFUELS MEDICAL RESEARCH

NovaWAVE. A new category of Automated Microwave Digestion

Chloride/Sulfate Analyzer

GRIMM Aerosol Technik Grimm Instrumentation The future of particle measurement Ing. Wolfgang Brunnhuber Environmental Division Manager

Data Logging Solutions from Lascar Electronics

Dry Hematology Analyzer Fast, Simple CBC Analysis Designed for the Point of Care

THE ULTIMATE Environmental fine dust measurement devices

Online data sheet SMC209 C CEMS SOLUTIONS

Coating Thickness Meter Data Sheet / Instructions

UCI Hardness Tester NOVOTEST T-U3 NEW

Stack Gas Analyzer ENDA-7000 ULTIMATE. Ultimate Reliability. Ultimate. Ultimate. Dependability. Accessibility

Counting Yeast, Human Platelet, and Algae

64C Amplification Block. Instruction Manual

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

Metal Transitions HIGH TEMPERATURE

Series description Wilo-Drain STS 40

ph & TDS instrumentation 2017 specialists in temperature measuring equipment for over 30 years

Moisture Analyzers ISO 9000 CERTIFIED

Leadership in Filtration. ScandMist Industrial air cleaners

Wireless Freezer Manual Installation Guide

XSTi Standby UPS. 400VA, 600VA, 800VA Models. User & Installation Manual

8 stream capability with dual mode (H 2 S & total Sulphur)

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

ELISA STAR Standard Solutions

GENECHECKER Ultra-Fast PCR System

Thermoforming packaging machine R 145 with MULTIVAC Clean Design. Maximum process reliability and cleanroom suitability

General Plan OXYGEN SERVICE CONTAINER 2005 Version 1.02

Low-mass PM analyzer MEXA-1370PM Improvement of the Performance for PM Composition Analysis

The answer is... yes!

Sampling. Stationary Portable. Sampling. Sewage Treatment. Municipal Sewerage Systems. Water Protection Control

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Transcription:

Portable Emissions Measurement System (PEMS) for nanoparticle counting and classification. testo NanoMet3

The portable solid particle counter testo NanoMet3. Measure in real environmental situations.

Onboard measurement of real driving emissions. Easy handling: One button measurement. Test any vehicle. Everywhere.

Portable Emissions Measurement System PEMS for nanoparticle counting and classification Raw gas particle concentration: 1E4 to 3E8 pt/ccm Particle size: 10 to 700 nm Power supply: 12-24 VDC / 100-240 VAC Gas conditioning: ThermoDilution PMP compliant testo NanoMet3 is a Portable Emissions Measurement System PEMS to measure number concentration and average diameter of solid nanoparticles in the size range 10 700 nm under real driving conditions. It is compact, easily portable, rugged design and provides on-line response over a wide concentration range. These properties make it a suitable instrument for particle number concentration measurements in non-laboratory settings and even OBD instrumentation. In addition to standard 100 240V AC power supply, testo NanoMet3 can be 12 24V DC battery operated for onboard and field measurements. The response time is short enough to measure transient engine operation, providing a complete data string with particle number concentration, average size, lung deposited surface area LDSA and calculated particle mass with 1Hz resolution. The wide measurement range (diluted 1E4 3E8 pt/cm3) covers practically all exhaust emission standards regarding particle number including the latest requirements of EURO6. Testo believes that NanoMet3 is therefore the ideal candidate for in-use-compliance testing, as well as for future PEMS type approval.

PEMS matters The increasing importance of accurate and cost effective testing has become a significant issue for the industry. A vast experience in nanoparticle measuring equipment for automotive, laboratory and ambient applications enabled us to develop a rugged, portable and costeffective solid nanoparticle counter. The PEMS methodology and approach has been recognized by many governmental entities such as the U.S. Environmental Protection Agency USEPA and the United Nations Framework Convention on Climate Change UNFCCC. Particle counting on diesel light-duty vehicles is mandatory in Europe for type approval through Euro 5b since September 2011 and has been also introduced for GDI technology through Euro 6 by September 2014. The European Union and other countries worldwide will continue to integrate particle counting into their emission standards, especially since the World Health Organization reclassified diesel engine exhaust as carcinogenic to humans. Moreover, the European Commission is working on the approach for the technical assessment of PEMS for particle number emitted by light-duty vehicles. The oncoming test procedure for EURO 6c standards may include on-road measurements as an extension of the PMP. Portable Emission Measurement Systems (PEMS) have been proven for certain applications to better identify in-use performance of vehicles than standard laboratory measurements. They are designed to measure emissions during the actual use of an internal combustion engine vehicle or equipment in its regular daily operation under real-world conditions. Furthermore PEMS constitute a cost effective solution to perform in-service testing of heavy-duty engines: rather than extracting the engines from the vehicles and then installing them on an engine dynamometer to run their official regulatory cycles, the vehicles are equipped with on-board emission measurement systems and tested during their real in-use operation. Measurement principle When the sampling point of the PEMS during Real Driving Emissions is at the outlet of the tailpipe, the volatile substances may condense into nanodroplets, which can be detected as particles together with nonvolatile solid particles. To measure only the solid particle fraction, it is necessary to condition the sample thermally to remove the volatile fraction. NanoMet3 features a separate sample at the source and conditioning of the exhaust probe according to Testo patented Thermo-Dilution principle, which is fully PMP compliant. The portable system is completed with Testo proprietary Diffusion Size Classifier technology, a new sensor for measuring the number concentration and average diameter of nanometer sized particles. Since its measuring principle uses electrical charging to count particles, it not only enhances the quality of the global measurement, but also the cost of acquisition and costs per test are significantly lower. Hydrocarbon emission measurement will no longer be affected by butanol contamination in the testing room, nor will it be influenced by contaminated air.

testo NanoMet3 assists you from engine development to vehicle certification. testo NanoMet3 provides easy and cost-effective access to valuable data such as: Communication Digital Memorycard» Raw data can be stored in internal HD, exported by SD-card or directly read by a host computer. Technical Specifications For more detailed information call +49 (0)7653 681 5062 sales-nanoparticle@testo.de aerosol concentration range particle size average particle size range (mode diameter) inlet gas flow primarily diluted exhaust gases or air which contains nanoparticles sensor: 1E3 to 1E6 pt/ccm; diluted: 1E4 to 3E8pt/ccm 10 to 700 nm = 0.01 to 0.70 μm 10 to 300 nm = 0.01 to 0.30 μm 4.0 ln/min, actively fed to the diluter by internal pump dilution factor standard: 10, 100, 300. Optional one custom DF. measuring gas power supply power consumption evaporation tube temperatures assembly weight operating conditions sensor calibration system calibration 1.0 ln/min measuring gas 12-24 VDC, max. 60A. 90-240 VAC 50/60 Hz nominal 650W; 300 W under standard ambient conditions ambient to 300 C / 572 F; accuracy ±3 C / 5,4 F 19" case with handles approx. 18 kg; with complete connections: ca. 23 kg Tamb: 5 to 35 C; 0 to 80%RH, max. 80%@30 C, linearly degrading to 50%@35 C, noncondensing standard calibration with NaCl particles against PMP-System with soot from CAST @ GMD 60 nm and 85 nm

testo NanoMet3 vs PMP 3.0E+11 2.5E+11 2.0E+11 1.5E+11 1.0E+11 0.5E+11 NEDC PMP-Benchmark NanoMet3 140 120 100 80 60 40 20 Benchmark measurements on NEDC cycles show 90-99% correlation* between NM3 and PMP systems. *(under regular conditions) 0 0 200 400 600 800 1000 1200 testo NanoMet3, DF=300 Benchmark, DF=300 (20x15) ECE: PN avg : 115 nm EUDC: avg ECE: PN avg PN : 95 nm avg avg EUDC: PN vg Correlation Particle Count testo NanoMet3 vs PMP-Benchmark 6.0E+12 5.0E+12 4.0E+12 3.0E+12 2.0E+12 1.0E+12 0.0E+00 0.0E+00 1.0E+12 2.0E+12 3.0E+12 4.0E+12 5.0E+12 6.0E+12 y = 1.12x - 2E+10 R2 = 0.99 Main features particle size plots versus time, total counts provided by software interface concentration removable memory card or internal hard disk diluter between recommended service Ordering information Order No. Description 444 testo NanoMet3 - Portable solid nanoparticle counter (PEMS PNC) Incl. transport case, heated line, LAN cable, antenna wireless, SD-card, USB extension cable, external signal cable, battery cable, D-Sub socket and D-Sub plug, waste-gas hose with coupling socket, country specific power cord and calibration sheet Please select the country specific power cord: 78021 Power cord 2 m, 3 x 1 mm 2 CH-plug 78022 IEC power 2.5 m 3 x 1 mm 2, Schuko plug 78023 Power cord 2 m, 3 x 1 mm 2 US-plug 78024 Power cord 2.5 m, 3 x 1 mm 2 GB-plug 78025 Power cord, 3 x 1 mm 2 AU-plug 2444 Yearly Service Pack (including calibration) for NanoMet3 2446 Calibration NanoMet3 Order No. Description Accessories and spare parts NanoMet3 333 NanoMet3 Sensor N3001 Transport case N1602 Heated sampling line 6424 Battery cables (power supply) N4303 Antenna wireless 2,4 GHz 6425 External signal cable for analog output Set excess-gas output 68010 Silicon hose N3509 Coupling socket Set OBD adapter 4445 OBD-BT-Adapter Scantool 4446 USB-BT-Adapter for OBD Communication 4447 Navilock GPS 4448 INCA Connection (Hardware and Software) Spare 3-pin power cord 78021 Power cord 2 m, 3 x 1 mm 2 CH-plug 78022 IEC power 2.5 m 3 x 1 mm 2, Schuko plug 78023 Power cord 2 m, 3 x 1 mm 2 US-plug 78024 Power cord 2.5 m, 3 x 1 mm 2 GB-plug 78025 Power cord, 3 x 1 mm 2 AU-plug

sts. Get in contact with our speciali Send an Email to Subsidiaries Distributors Your partner in nanoparticle management Our former specialist in nanoparticle management Matter 7KH H[WHQVLYH VSHFLDOL]HG DQG UHFRJQL]HG 5HVHDUFK Aerosol has been a member of the Testo family since 2010. Development know-how of Matter Aerosol is now completed In 2015 it has been fully integrated into the Testo AG. with more than 50 years expertise from Testo AG as a world With the full integration of the nanoparticle measurement market leader in the field of professional measurement technology business sector, Testo AG is pursuing the technology. With this new arrangement, perfect solutions objective of a targeted and customer-oriented utilization of in the nanoparticle measurement technology sector will be WKH V\QHUJLHV LQ 5HVHDUFK 'HYHORSPHQW DV ZHOO DV WKH developed for you. extensive and proven possibilities and means available in industrial production, service and sales. Testo AG Tel. +49 (0)7653 681 5062 sales-nanoparticle@testo.de www.testo-particle.com Subject to change, including technical changes, without notice. GN/I/0.2015 sales-nanoparticle@testo.de