OFFICIAL SOUTH CAROLINA WOOD INFESTATION REPORT

Similar documents
1C Vineyard Trail Garland, TX Address of Inspection Company City State Zip Telephone No.

In Depth Home Inspection LLC Report # Doe STRUCTURAL PESTS & DRY ROT INSPECTION REPORT

COMPLETE REPORT LIMITED REPORT X SUPPLEMENTAL REPORT REINSPECTION REPORT General Description:

WOOD DESTROYING PESTS AND ORGANISMS INSPECTION REPORT. Alyssa Duggan The Duggan Group 231 Market Place #224 San Ramon, CA 94583

WOOD DESTROYING PESTS AND ORGANISMS INSPECTION REPORT. Building No. Street City Zip Date of Inspection Number of Pages

ADDRESS OF PROPERTY INSPECTED: 25 XXXXXXXXXXXX Street, Perth WA NAME OF CLIENT: XXXX XXXXXXXXXXXXXXX CLIENT S ADDRESS: XXXXXXXXXXXXXXXXXX

InterNACHI. Advanced Inspection of Crawlspaces for home inspectors

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

CONDITION OF PROPERTY SURVEY Structural Integrity of Framing.

TEXAS OFFICIAL WOOD DESTROYING INSECT REPORT Page 1 of 3

Truth in Sale of Housing Disclosure Report NOTICE - Read Entire Report Carefully. This is not a Buyer's Inspection!

Inspection Report. Provided By PBG NSW P/L. Po Box 194, Stockton, New, 2295, Australia P

KEVIN BURNS HOMES PRACTICAL COMPLETION REPORT VISUAL BUILDING INSPECTION REPORT

APPLICATION FOR PORCH / DECK PERMIT

Chapter 2 Understanding The Problem

HANDOVER REPORT. Property Address: XXXXX XXXXX. Report Number: Inspection Date & Time: XXXXX

I m Having a Wood Destroying Insect Inspection What Can I Expect To See On My Report?

Post Remediation Warranty

Residential Building Permit Application

FIBERGLASS BATTS ACHIEVING GRADE I INSULATION WITH. Prepared by

The Inspection Process. Waxhaw N.C.

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

MOLD INSPECTION REPORT Block Home Inspections LLC

Detached Garages and Building Permits. 1 and 2 Family Dwellings

Presented by The National Association of Certified Home Inspectors Chicago Chapter

Administrative Changes

Visual Timber Pest Inspection Report

Storm Damage Assessment Report For: 1234 Example Street., Houston, TX 77002

Encapsulated, Sealed & Closed Crawlspace Installation Manual

District of Barriere A GUIDE TO BUILDING PERMITS

Home Inspection Report Report Number: For The Property Located On:

CITY OF GLASGOW BUILDING PERMIT APPLICATION 126 E. Public Square Glasgow, KY Phone: (270) Fax: (270)

Continuing Certificate of Occupancy Pre-Inspection Checklist

Application Requirements for obtaining a Building Permit

SPRAY FOAM Insulation & Termites

Close-Up Home Inspection Home Inspection Report

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

Rebuilding your Home after the storm? Adding on, renovating, or remodeling your home? Here's information YOU need to know about the 50% Rule.

Sample Pre-drywall Inspection Report

Basement Renovation Guide For Residential Dwellings

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

Infrared Inspection Report

SAMPLE. Building Inspection Report. Inspection Date: Thu, 11 Feb 2016 Property Address:

City of Centerville Building, Zoning & Code Enforcement Department

STRATEGIES FOR TERMITE RESISTANCE TEK 3-9A

BASEMENT FINISH CONSTRUCTION PLANS REFERENCE: 2015 INTERNATIONAL RESIDENTIAL CODE. PERMITS

OWNER S REPONSIBILITIES AND PREPARATION INSTRUCTIONS. Schedule "C"

AGREEMENT CONCERNING EXISTING AS BUILT CONSTRUCTION

Radon Vent Pipe System. Labeling Performance Indicators

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Advanced Ventilation for Residential applications FBC Res 2010.

_Truth Termite Bait_ _1_75313_.pdf

This report is general in nature and not technically exhaustive.

CITY of COLDWATER. Requirements for Obtaining Building Permits City of Coldwater, Michigan

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

EXPERT BUILDING INSPECTION 51 KENT STREET BALLSTON SPA, NY PREPARED FOR JOHN DOE 123 MAIN STREET ANYTOWN, NY 12345

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

FAIRA TRANSPARENCY REPORTS. January 12 th, 2017

Visual Building Inspection

Applying for Permits to build a new house in Linn County

REQUIREMENTS FOR SUBSTANTIALLY DAMAGED AND SUBSTANTIALLY IMPROVED STRUCTURES

Inspection Report Summary

PRE-PURCHASE PROPERTY INSPECTION REPORT To AS

NB Power s Home Insulation Energy Savings Program as of August 1, PROGRAM INTRODUCTION PROGRAM OVERVIEW ELIGIBILITY...

HomeGuard DPC Termite Moisture Barrier

BUILDING INSPECTION. Mar 16, 2015 PROPERTY ADDRESS Killymoon Drive Hope Island, QLD 4212, Australia. 1 of 44

Important Notice To Building Permit Applicants and Designers

Chapter 6 The Improvements Section

Home Building Planner

2003 International Residential Building Code

Subterranean Termites

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

PRE-FABRICATED HOUSING

Trusted DIVISION: 07 SYSTEM. Conformity! ICC-ES Evaluation. not specifically. Copyright 2014

Structural Inspection

Asbestos Consulting Radon Measurements Lead Assessments Indoor Air Quality Testing Mold Investigations. Project Number: Page 1 of 22

Course Information. Title: Modular Building Foundations Advanced Module

Building Moisture Survey

PRINCIPLES FOR THE CONSERVATION OF WOODEN BUILT HERITAGE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION (RIGID PU SYSTEMS)

THE CONSTRUCTION SUPERVISOR

NARI National 2018 CotY Program Categories Please read category descriptions carefully as some criteria have changed.

3D Home Improvement and Inspection Services, Inc

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

TOWN OF DEWITT PLANNING AND ZONING PERMIT REQUIREMENTS FOR DECKS

FOOTINGS AND FOUNDATIONS

Technical Bulletin. No. 21 : Insulating Basements and Crawl Spaces (Revised 7/04) hwinsulation CONTRACTORS ASSOCIATION OF AMERICA

Residential Accessory Structure Application Packet (Carport, Shed, Garage, Pool)

RESIDENTIAL DETACHED STORAGE STRUCTURES (GARAGE)

Property Inspection Report

MOLD & FUNGI TECHNICAL BULLETIN

Building Permit Application Instructions INFORMATION REQUIRED FOR ISSUANCE OF A BUILDING PERMIT

St. Louis County Department of Public Works Division of Code Enforcement. When is a Building Permit required for Residential Projects?

PHASE (pre-drywall) INSPECTION REPORT

Commercial Tax Abatement

BASEMENT FINISH CONSTRUCTION

1996 Bachelor of Science, Civil Engineering University of Central Florida, Orlando, Florida

Transcription:

OFFICIAL SOUTH CAROLIA WOOD IFESTATIO REPORT THISREPORTVALIDFOR45 DAYS OLY. THISREPORTMAY OT BEUSEDIAREALESTATECLOSIGAFTER45DAYS. THIS REPORT IS OT TO BE COSTRUED AS A GUARATEE OR WARRATY AGAIST FUTURE IFESTATIO OR DAMAGE. IT IS RECOMMEDED BY THE DEPARTMET OF PESTICIDE REGULATIO, REGULATORY AD PUBLIC SERVICE PROGRAMS AD THE SOUTH CAROLIA PEST COTROL ASSOCIATIO THAT THE PURCHASER OF THE STRUCTURE, RATHER THA THE SELLER, OBTAI THIS WOOD IFESTATIO REPORT. Date 7/17/2007 File o. This is to report that aqualified inspector employed by the below named firm has carefully inspected readily accessible areas, including attics and crawl spaces which permit entry, of the property located at the below address for termites, other wood-destroying insects, and fungi. The inspection for fungi and fungi damage commonly called water damaged wood, rot or decay is limited to the areas below the first main floor of the structure as defined by DPRP-198. This report specifically excludes hidden areas and areas not readily accessible and the undersigned pest control operator disclaims that he has made any inspection of such hidden areas or of such areas not readily accessible. Theinspection described has been made on the basis of visible evidence, and special attention was given to those accessible areas which experience has shown to be particularly susceptible to attack by wood-destroying insects. Probing and/or sounding of those areas and other visible accessible wood members showing evidence of infestation was performed. This report is submitted without warranty, guarantee, or representation as to concealed evidence of infestation or damage or as to future infestation. If there is evidence of active infestation or past infestation of termites and/or other wood destroying insects or fungi, it must be assumed that there is some damage to the building caused by this infestation; however any visible damage to awood member in accessible areas has been reported. The below-named firm's inspectors are not engineers or builders, and you may wish to call aqualified engineer or expert in the building trade to provide their opinion as to whether there is structural damage to this property. LOCATIO OF PROPERTY ISPECTED 9830 Cornell Avenue OWER Rusty Jordan CITY Charleston STATE SC ZIP CODE 29423 STRUCTURE TYPE House w/ Attached Garage TYPE OF TRASACTIO: FHA VA COVETIOAL LOA ASSUMPTIO CASH SALE Check Only IF AY OF THE FOLLOWIG ITEMS ARE MARKED YES, DESCRIBE O SIDE 2: Appropriate Items o WERE AY AREAS OF THE PROPERTY OBSTRUCTED OR IACCESSIBLE?... IFESTATIO 1. There is visible evidence of active: (A) subterranean termites... (B) other wood-destroying insects 2. There is visible evidence of a previous infestation of: (A) subterranean termites... (B) other wood-destroying insects 3. There is visible evidence of prior subterranean termite treatment... 4. There is evidence below the first main floor of the presence of: (A) active wood-destroying fungi (wood moisture content 28% or above)... (B) wood-destroying fungi is present but not active (less than 28% wood moisture content) 5. There is evidence of the presence of excessive moisture conditions below... the first main floor (20% or above wood moisture content, standing water, etc.) DAMAGETermite, other wood-destroying insects and fungi (ote: reporting of fungi damage to wood, commonly called water damage, decay or rot, is limited to the area below the first main floor of the structure as defined by DPRP-198.) At the time of our inspection, there were visibly damaged wooden members (e.g. insect damage to columns,... sills, joists, plates, doorjambs, headers, exterior stairs, porches, or fungi damage to the first main floor) If the answer is "YES," specify causes and location(s) on back (Side 2). Check Appropriate DAMAGE OBSERVED (IF AY) Block Below A.... Will be or has been corrected by this company... B. Will be or has been corrected by another company, see attached contract... C. Will not be corrected by this company, recommend that structure be thoroughly and completely... evaluated by a qualified building expert licensed or registered with the S.C. Department of Labor, Licensing, and Regulations, Residential Home Builder's Commission and that needed repairs be made D. In our opinion there is insufficient visible damage to recommend repair.... (Explain on the reverse why repair was not recommended. Check Appropriate TREATMET Block Below 1. The property described was treated by us for the prevention or control of termites 04/29/2008 (date of treatment) A waiver has been issued and is attached to this form.... The present treatment will expire on 06/29/2008 and may be renewed initially at by the owner. 2. The property described has not been treated by us and is not now under contract with our firm. #CL-100 Approved by the South Carolina Pest Control Association, Inc. and the Division of Regulatory and Public Service Programs of Clemson University.... Revised 3/99 - Supersedes earlier versions. SEE SIDE TWO OF THIS REPORT FOR ADDITIOAL CODITIOS GOVERIG THIS REPORT Side 1

CODITIOS GOVERIG THIS REPORT Please read carefully. This report is based on the observations and opinions of our inspector. It must be noted that all buildings have some wood members which are not visible or accessible for inspection. It is not always possible to determine the presence of infestation without extensive probing and in some cases actual dismantling of parts of the structure being inspected. All inspections and reports will be made on the basis of what is visible, and we will not render opinions covering areas that are enclosed or not readily accessible, areas of finished rooms, areas concealed by wall coverings, floor coverings, insulation, furniture, equipment, stored articles, or any portion of the structure in which inspection would necessitate tearing out or marring finished work. We do not move furniture, appliances equipment, etc. Plumbing leaks may not be apparent at the time of inspection. If evidence of such leaks is disclosed, liability for the correction of such leaks is specifically denied. o opinion can be rendered as to infestation or damage on the portion of sheathing, siding, or other susceptible material which continues below soil grade. The areas of the substructure and attic that are accessible and open for inspection have been inspected. The substructure is defined as that portion of the building below the first main floor living space. Detached garages, sheds, lean-tos, fences, or other buildings on the property are not included in this inspection report unless specifically noted. The company, upon specific request and agreement as to additional charge, will open any inaccessible, concealed, or enclosed area and inspect same and make a report thereon. REMARKS THIS SPACE IS TO BE USED TO DETAIL AY "YES" ASWERS FROM THE FROT OF THIS FORM. ICLUDE ITEM UMBER WITH EACH EXPLAATIO. CLARIFICATIO AD EXPLAATIO OF OTHER ITEMS MAY ALSO BE ICLUDED. either Inor the company for which Iam acting have had, presently have, or contemplate having any interest in this property. Ido further state that neither I nor the company for which I am acting is associated in any way with any party to this transaction. LICESE UMBER OF PERSO SIGIG THIS REPORT 123456 (MUST BE CERTIFIED I CATEGORY 7A) Firm: ABC Pest Group Business License umber 1234567890 ADDRESS PO Box 2831 OF FIRM: Charleston 2942 29423 ACKOWLEDGMET: PURCHASER ACKOWLEDGES THAT A COPY OF THIS REPORT HAS BEE REVIEWED AD RECEIVED BY: Sam Eagleye DATE ACKOWLEDGED Side 2 PURCHASER'S SIGATURE

Address of Property Inspected 9830 Cornell Avenue Charleston, SC 29423 Additional Comments Graph Date 7/17/2007 File umber Copyright 2007 ew Image Software All rights reserved. Attachment A

Wood Destroying Organism Inspection Report Addendum Inspector s ame: Sam Eagleye Property Address: 9830 Cornell Avenue, Charleston, SC, 29423 Date File umber otes Here Attachment A

ISPECTIO PHOTOS # 1 # 2 # 3 # 4 # 5 # 6 P1 9830 Cornell Avenue, Charleston, SC, 29423