MP-300. The most thermally efficient, robust and reliable medical incinerators on the market. Simply Built Better!

Similar documents
Incinerator Options. Surefire TS Fixed Hearth Incinerators. todaysurematthews.com +44 (0) Application. Throughput Capacities

MultiZon incinerator for batch operation

De Montfort Mark 7 Incinerator (Flatpack)

Bio-medical Wastes Disposal Incinerator Systems - Understanding, Criteria and Analysis For Comparative Selection, By Homi R. Mullan.

UFL Micro Biogas CHPs

APPROVAL FOR HAZARDOUS (BIOMEDICAL) WASTE INCINERATION PLANT FOR HOSPITALS

SANY ASPHALT BATCHING PLANT

Product catalogue. Compliant with EN norm

Technical Description Package Micro Auto Gasification System (MAGS )

Appendix VIII: Determination of chimney heights

RIELLO 40 N SERIES. One Stage Heavy Oil Burners FIRING RATES HEAVY OIL. N kw N kw

TECHNICAL DATA SHEET GRILON TS V0

Experts in Furnaces. Engineering. Fast and flexible. THERMCONCEPT powerd by innovation

DICTATOR Lift Shaft System

Furnace Monitoring and Billet Cutting System

Furnaces for Research and Laboratory. Testing Drying Ashing Tempering Preheating Sintering Firing Annealing

Online Gas Analyzer / Monitor

Design and distribution of air nozzles in the biomass boiler assembly

HIGH TEMPERATURE FURNACES. High Temperature Chamber Series High Temperature Tube Series High Temperature Elevator Series

Overview of the Gaz de France R&D activities on flameless oxidation applied to high temperature processes

Three-sided barrier compliant to DIN EN ISO Depending on location, design also as wind protection. Clear height (DH) Three-sided barrier

Oil Conservation in Biscuit Industry

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

PRODUCT BROCHURE ARCHITECTURAL FABRICATIONS

Reflow Oven. USA HEADQUARTERS:

Combustion Laboratory Unit C492

Downsizing a Claus Sulfur Recovery Unit

Design & Construction Standards, Revised January

Agenda. About Designplan. Robust. Considerations for Robust Products. Applications. Characteristics

Information Pack BG25 / BG50

170MM 360MM Specifications

Non-contact temperature measurement from 50 C to 2200 C

Thermocouple for Flue Gas Temperature Measurements,

GUIDANCE NOTE ON THE BEST PRACTICABLE MEANS FOR

Assessment of Losses of Reheating Furnace in a Steel Re-Rolling Mill

Electric Furnace Off-Gas Cleaning Systems Installation at PT Inco ABSTRACT

Tek Spec 4.0. Reference Guide

All boilers with touch screens. Log Wood

Legal Aspects and Process of Biomedical Waste Management Practices in India. *Prakash V **Dr. N. Palaniraj

60 years. of progressive development

THE COMBUSTION OF HYDROCARBONS. I love the smell of napalm in the morning smells like victory!

WM2008 Conference, February 24-28, 2008, Phoenix, AZ Abstract #8216. Thermal Pretreatment For TRU Waste Sorting

Burning inspiration 1

Combustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

AB-1020 EP Dust Free Vacuum Blast Machine

BURNERS EXCESS AIR SINGLE TUNNEL COOL FLAME

Emissions from wood-fuelled equipment. Senior research scientist Heikki Oravainen Technical Research Centre of Finland

AIRCOOL VENTILATORS FURTHER INFORMATION

Compact flue gas analyser: testo 300 M-I

Product Data Sheet RESOPAL EXCELLENT

DESIGN OF GRAIN DRYER

Dunbrik A1 Concrete Flue Liners

Controlling NOx and other Engine Emissions

CARBON STEEL BARS HOT ROLLED

Technical Notes for Biomass and Air Quality Guidance

composition. Environmental Choice) as having lower environmental impact. Certification and further information is available at

Foundry.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

MOBILE SUBSTATIONS TRAILER AND SKID. tgood.com. Energy, Fast!

european fire standards and national legislation

DISTRICT HEATING SYSTEMS FROM LIGNITE FIRED POWER PLANTS TEN YEARS EXPERIENCE IN GREECE

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

Controlled Environments. Product Data Sheet. Controlled Environment Panel System KS1100 CS

PTAC PROCESS TECHNOLOGY II - SYSTEMS. Last Reviewed: Page 1 of 10

Define fuel. List any two characteristics that you would look for in a good fuel. Answer.

FLAME AERODYNAMICS COMBUSTION AND FUELS

GLAUNACH THE SILENCER HANDBOOK INSULATION SUPPLEMENTARY ACOUSTIC SHIELDING OF SILENCERS, PIPES & CO GLAUNACH GMBH ALL RIGHTS RESERVED -

OIL AND GAS FIRED. Energy Conservation, Efficiency,Environmental Protection

Vengen 28. There s a much bigger picture to be found at Ruskin Air Management. Double Glazed Thermal Break Louvre Window. naco.

Building Design Data

Gas Fireplaces

The illbruck Pocket Guide to The Complete Range of PU Foams


Geothermal Power Plant

ELECTRICAL SAFETY INSPECTION REPORT

Experimental Study on Combustion of Biomass in a Boiler with Gasification

learncbse.in learncbse.in COMBUSTION AND FLAME

Shipping Container R&D Test Plan

Thermoforming packaging machine R 145 with MULTIVAC Clean Design. Maximum process reliability and cleanroom suitability

Catalogue EDITION: MAY 2014

Technical Leaflet. Product Data Sheet for HPL Composite Panels

TECHNICAL SPECIFICATION

COMBIMASS Thermal Gas Flow

HILTI CP 657 Firestop Brick

RECONSTRUCTION AND REPLACEMENT OF EARTHQUAKE DAMAGED MASONRY CHIMNEYS

White Paper. Fire Sprinkler Riser Corrosion. (May 2014) Jeffrey Kochelek (Engineered Corrosion Solutions, LLC) V.1.0.1

FITOCLIMA WALK-IN STABILITY

Steam Power Station (Thermal Station)

Recent Technologies for Steam Turbines

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: EARTHCORE INDUSTRIES, LLC

Laboratory.

Hamm MW Pyrolysis Plant. Integrated Pyrolysis into Power Plant Plant capacity 100,000 t/a Pre-processed Waste Materials

Special Electrically Resistant Heated Furnaces

Plant construction and waste heat systems for the chemical industry

Mapping Solid Waste II Sample Collection & Analysis

BURNER FLAME TEMPERATURE DURING WARM UP AND HOT STANDBY. Alan D. Mosher KPS Technology & Engineering LLC

INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK

Transcription:

The most thermally efficient, robust and reliable medical incinerators on the market Simply Built Better! Specifically designed for medical waste. MP-300 The MP medical hot hearth Incinerators The Addfield range of Medical & Pathological incinerators (MP Series) are bespoke incinerators specifically designed for the destruction of high category medical/pathological red bag waste. These wastes types generally have high moisture contents and low calorific values such as blood, human organs/tissues swabs etc. The MP series has been specifically designed to completely and efficiently destroy these wastes with the higher moisture contents of 50% and above. MP-300 AI Controller e: e: sales@addfield.com sales@ www.addfield.com www Unit Hollies 9 Zone Park 4 Burntwood Cannock Business Staffordshire Park Staffordshire WS11 1DB UK WS7 3XD UK CFD Modelling Hot Hearth All information should be used as a guide only, specifications are subject to change without notice. Addfield Environmental Systems Ltd

The MP range is designed as a two stage incinerator unit comprising of a primary loading chamber that incorporates a hot hearth construction for the total destruction of the solid/liquid wastes. The unit is further complemented by an integral after burner system. This afterburner draws the hot gases from the primary chamber under the hearth through an integral refractory brick system. This ensures maximum gas turbulence/ mixing is achieved thus aiding clean combusted gases. All gases then reside inside the after burner chamber for a minimum of 2 seconds at temperatures of 850-1150 C ensuring complete high temperature termination/ oxidation of the gas combustion products. emissions testing concluded the following results based on two second residue time within the secondary chamber, results are well below the EC limits. Expected Emissions* Carbon Dioxide (C02) Water (H20) Oxygen (02) Sulphur Dioxide (S02) Nitrogen (N2) Smoke (Not detectable under standard operating conditions) Odour (Not detectable under standard operating conditions) Volume of ash (Dependent on waste stream) % by Volume 5% 29% 6% 6% 54% 0% 0% 1-3% values of 6kcal/g (blood) 45.7MJ/kg (human organs), 70-100% moisture contents. With no other waste streams present other than general packaging containers that do not make up more than 1.5% of the total load weight. Composition of fuel being used: Fuel Input Diesel Composition % Carbon Hydrogen Nitrogen Oxygen C H1 N2 O 2 86% 13.2% 0.70% 0.00% Machine Specifications MP-300 External Length (mm) External Width (mm) External Height (mm) Primary Chamber Sizes: Internal Length (mm) Internal Width (mm) Internal Height (mm) Max Load Capacity (kg) <300 Nominal Burn Rate UK*(kg/hr) <50 Burn Rate [Export Only]* (kg/hr) 50-75 Thermal Capacity (kw/hr) 190 Power Supply 50/60hz 210/230v Fuel Options: Diesel LPG N-Gas 2640 1150 2100 1600 700 700 Based on general municipal waste streams * Depending on the type waste stream being loaded and excludes heat up time. and quality of materials from time to time, so long as the alteration is minor or an improvement to the said products. Ideal for Category 2, 3 & 4 type red bag waste with high density and high moisture contents. mental Systems Ltd e: sales@ www e: sales@addfield.com www.addfield.com Unit Hollies 9 Zone Park 4 Burntwood Cannock Business Staffordshire Park Staffordshire WS11 1DB UK WS7 3XD UK

Computational Fluid Dynamically Modelled Incinerators Key Features: We have CFD modelled all of our incinerators by utilising some of the most advanced software available. By using Computational Fluid Dynamics software it helps us to predict gas velocities /movements within the chambers along with external surface temperatures whatever the external ambient parameters maybe. We also use this information to develop a more durable, robust and efficient incinerator by: Identifying heat build-up and stress points within the structure. Reducing thermal heat loss by increasing insulation systems. Designing out hot & cold spots to ensure compete combustion within the chamber. General Construction Robust, Reliable and Efficient Pre-fabricated 8 & 10mm robust mild steel casing, seam welded & suitably stiffened/ braced where necessary. using a two pack high grade paint system that is baked onto the steel structure at 70 C for 10hrs. Standard colours of the MP Series are cherry red for the main body, with a solid black door and upper cover plates. ing a tight seal & gives excellent thermal efficiency. Primary & secondary chamber lining thickness 221mm, rated at 1750 C. Low thermal mass roof lining, with removable roof and back plate for ease of maintenance. Primary Chamber Fully insulated internal refractory lining, constructed from high grade refractory brick ensuring a self-supporting interlocked arrangement. One fully interlocked, manually operated, access door One waste ignition burner, temperature controlled on-off, complete with internal air fans One hot hearth combustion burner, temperature controlled on-off, complete with internal air fans Secondary combustion burner air fans with automatically controlled distribution to their designated area. Two temperature sensor mounting points Secondary Chamber Fully insulated internal refractory lining, constructed from high grade refractory brick and low thermal mass insulation. One secondary chamber burnout burner, temperature controlled on-off, complete with internal air fans Integrated combustion burner air fans with automatically controlled distribution to their designated area. All combustion fuel pipe work All electrical requirements One temperature sensor mounting point at the reaches the necessary 850 C/1100 C minimum. are subject to change without notice. e: e: sales@addfield.com sales@ www.addfield.com www Unit Hollies 9 Zone Park 4 Cannock Burntwood Staffordshire Business Park WS11 Staffordshire 1DB UK WS7 3XD UK

Addfield Intelligent Controller Waste Loading and De-Ashing The MP Series of incinerators are designed for manual loading only through the main access door due to the type of wastes they incinerate, bio-security measures should be in place on the site of the incinerator due to the possibility of Why Addfield? spillage and spread of disease. At the end of every incineration process ash should be discharged through the loading door onto the supplied catcher tray prior to being loaded for the next burn. Key Features: Plug and play design for easy & efficient replacement. Zone ramp sequence three zone controller Incoming and outgoing cable terminations Burner control gear Interface relays and contactors Temperature indication and control of the primary chamber Temperature indication and control of the secondary chamber Plant status indicators Cycle status indicators Fault status indicators Operator interface. Waste types to be used in the MP Series - Category 4 Minimum 50-100% moisture Blood, drips, human faeces Human organs Human tissues Human limbs Cancer treatment wastes Pharmaceuticals Surgery waste Syringes/ needles Combustion System The burner system comprises of fully automatic package burners, these burners come complete with the following features: Flame failure controls Integral fuel pump Solenoid valves Integral continuous air fan Fuel sensors t: e: +44(0)1543 sales@ 571280 f: +44(0)1543 www 571173 e: sales@addfield.com www.addfield.com Unit Hollies 9 Zone Park 4 Burntwood Cannock Business Staffordshire Park Staffordshire WS11 1DB UK WS7 3XD UK

MP-100 INCINERATOR MP-300 Incinerator Weather Guard 450 400 400 400 720 3558 1658 1800 FLOOR PLAN 150mm concrete base 781 600 Front loading door Chimney Sections *Can be made longer 1500 Control Panel 3 2644 1150 100 4644 rev. description date 2150 Incinerate - Cremate Addfield Environmental Systems Ltd Addfield Environmental Systems Ltd Unit Unit 9, 17 Zone Hollies 4, Park Burntwood Cannock Business Park, Staffordshire, WS11 WS7 1DP 3XD www.addfield.com www.addfield.co.uk title GENERAL ARRANGEMENT OF MP.300 INCINERATOR scale:- Not to scale All information should be used as a guide only, specifications are subject to change without notice. Addfield Environmental Systems Ltd drg. no. RLC drawn:- date:- MP.300-GA rev.