Health Assessment Of Reinforced Concrete Structures - A Case Study

Similar documents
Non-destructive Testing of Concrete - Methods of Test. Lecture No. 26

Maryam Nasser AlHarthy Student, Department of Built and Natural Environment, Muscat, Sultanate of Oman Corresponding author:

Reliability Of Non-Destructive Tests For Hardened Concrete Strength

Destructive and Non- Destructive Testing for Concrete in Sudan - A Comparative Study

Non-Destructive Evaluation of Concrete using Ultrasonic Pulse Velocity

In situ non-destructive testing: the steel and concrete resistance assessment of ancient r/c structures

Application of Rebound Hammer Method for Estimating Compressive Strength of Bricks

An Experimental Investigation on BioMedical Waste Concrete

Study on Estimated In-situ Cube Strength from Cores and Cube Strength

CORROSION MONITORING IN REINFORCED CONCRETE BY ACOUSTIC EMISSION

PRISM TEST, FLAT JACK TEST, REBOUND HAMMER, & MECHANICAL PULSE VELOCITY

The choice of concrete as a building material in con-structing

Ultrasonic Pulse Velocity and Rebound Hammer Testing for Nondestructive Evaluation of Existing Concrete Structure

International Journal of Advance Engineering and Research Development. The Experimental Investigation of Durability Test on Concrete Cubes

Pushover analysis of RC frame structure using ETABS 9.7.1

Assessing the strength of reinforced concrete structures through Ultrasonic Pulse Velocity and Schmidt Rebound Hammer tests

AN EXPERIMENTAL STUDY ON GLASS FIBRE REINFORCED CONCRETE

EARTHQUAKE ANALYSIS OF A G+12 STOREY BUILDING WITH AND WITHOUT INFILL FOR BHUJ AND KOYNA EARTHQUAKE FUNCTIONS

Course Concrete Technology Course Code Theory Term Work POE Total Max. Marks Contact Hours/ week

Structural Assessment and NDT Procedures

Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

Comparative Study of R.C.C and Steel Concrete Composite Structures

Restoration and Rehabilitation FRP Wrapping

DETERMINING THE STRENGTH OF SOLID BURNT BRICKS IN HISTORICAL STRUCTURES

Studies on ductility of RC beams in flexure and size effect

Module 8: Composite Testing Lecture 36: Quality Assessment and Physical Properties. Introduction. The Lecture Contains

MECHANICAL PERFORMANCE OF RECYCLED PET FIBER REINFORCED CONCRETE WITH LOW VOLUME FRACTION

UNIT 9 INSPECTION AND QUALITY CONTROL

Mix Design and Pumped Concrete

Measurement and Documentation for Structural Integrity Assessment of an In-Service School. Building at Risk

THE EFFECTS OF P-DELTA AND CONSTRUCTION SEQUENTIAL ANALYSIS OF RCC AND STEEL BUILDING WITH RESPECT TO LINEAR STATIC ANALYSIS

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 07, 2014 ISSN (online):

In-plane testing of precast concrete wall panels with grouted sleeve

5th Pan American Conference for NDT 2-6 October 2011, Cancun, Mexico

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Early age strength assesement for high rise buildings

Strength of Normal Concrete Using Metallic and Synthetic Fibers Vikrant S. Vairagade* a and Kavita S. Kene b

Reinforced Concrete Design. A Fundamental Approach - Fifth Edition

Base Isolation In Seismic Structural Design

Non-Destructive Assessment of the Historic World War Memorial Baseball Stadium, Greensboro, North Carolina

BEHAVIOR OF REINFORCED CEMENT CONCRETE BEAM WITH BAMBOO AS PARTIAL REPLACEMENT FOR REINFORCEMENT

Experimental Investigation of Recycled Plastic Aggregate in Concrete

ctbuh.org/papers Prediction and Compensation of Column Shortening for Bitexco Financial Tower Title:

The Utilization of Quarry Dust as Fine Aggregates in Concrete

ANALYSIS OF SIMPLY SUPPORTED REINFORCED CONCRETE SKEW SLABS

SEISMIC BEHAVIOR OF RC BUILDING FRAME WITH STEEL BRACING SYSTEM USING VARIOUS ARRANGEMENTS

SIGNIFICANCE OF STRUCTURAL INTEGRITY ASSESSMENT IN THE SUSTENANCE OF NIGERIA S INFRASTRUCTURAL DEVELOPMENT

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

Replacement of Fine Aggregate in Concrete with Municipal Solid Waste Bottom Ash from Incinerator

STRENGTH PERFORMANCE OF CONCRETE USING BOTTOM ASH AS FINE AGGREGATE

FIBER ADDITION AND ITS EFFECT ON CONCRETE STRENGTH

Specified Tests for Concrete Quality

Fracture Parameters of Coir Fibre Reinforced Concrete

EVALUATION & REPAIR OF CORROSION DAMAGED ROOF LIFT SLAB WITH WIRE POST-TENSIONING SYSTEM (BUTTON HEADS)

Deflection Analysis with Shoring Load Transfer Coefficient for Post-Tensioned Slab

CONTINUOUS FLIGHT AUGER (CFA) PILES QC/QA PROCEDURES. Preferred QC/QA Procedures

Available online at ScienceDirect. Procedia Engineering 144 (2016 )

NEW HYBRID GLULAM BEAM REINFORCED WITH CFRP AND ULTRA-HIGH-PERFORMANCE CONCRETE

SHEAR BEHAVIOR OF DOUBLY REINFORCED CONCRETE BEAMS WITH AND WITHOUT STEEL FIBERS AFFECTED BY DISTRIBUTED CRACKS

STRENGTH APPRAISAL BY FIBRE EINFORCEMENT IN CONCRETE

UHPC Connection of Precast Bridge Deck

Fundamentals of Concrete

DAMAGE ASSESSMENT REINFORCED CONCRETE BEAMS USING ACOUSTIC EMISSION TECHNIQUE

Utilization of Stone Dust as Fine Aggregate Replacement in Concrete

Investigations on Some Properties of no-fines Concrete

In-situ Concrete Strength Assessment based on Ultrasonic (UPV), Rebound, Cores and the SONREB Method

Satish Sharma, B.S. Rao. Adarsh Kumar NS, Rizwan Anwar, Ankit Sharma National Council for Cement and Building Materials, India

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

Study of P-Delta Effect on Tall Steel Structure

DURABILITY PROPERTIES OF HIGH PERFORMANCE CONCRETE USING INDUSTRIAL BYPRODUCTS

Impact of Admixture and Rice Husk Ash in Concrete Mix Design

Dr. SWARUP RANJAN DEBBARMA B.Tech (Civil), M.E (Structures), Phd

Size and Dosage of Micro Silica Fume Behaviour for Partial replacement of Cement in Concrete

Failure Process in Shear Bonding Strength Tests between Existing Concrete and Repairing Material by Acoustic Emission Technique

Study of Shear Behavior of RC Beams: Non Linear Analysis

Study of Modulus of Elasticity of Steel Fiber Reinforced Concrete

CONCRETE MIX DESIGN. Dr. B.N. KRISHNASWAMI TECHNICAL MEETING ON ORGANISED BY CIVIL ENGINEERS & ARCHITECTS ASSOCIATION, KUMBAKONAM

Residual Compressive Strength of Recycled Brick Aggregate Concrete at High Temperatures

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

MURALT WALLS: VIANE AND SCHELPHOEK, NETHERLANDS

FATIGUE DURABILITY OF A REINFORCED CONCRETE DECK SLAB IN A COLD SNOWY REGION

3. Bond, Anchorage and Shear This chapter will discuss the following topics:

DETECTION OF INCLINED CRACKS INSIDE CONCRETE STRUCTURES BY ULTRASONIC SAFT

High Volume Fly Ash Concrete for Paver Blocks Som Nath Sachdeva, Vanita Aggarwal, S. M. Gupta

Using Thermal Integrity Profiling to Confirm the Structural Integrity of foundation applications

The Detection and Analysis of Reservoir Dam Crack Depth and Grouting Quality Analysis

Determining in-place concrete strengths is particularly

Behaviour of Concrete Filled Rectangular Steel Tube Column

Concremote shall be verified and evaluated based on demonstration castings using 4 unique mix-designs.

Strength Evaluation of Existing Concrete Buildings

ESTIMATION OF THE IN-SITU CONCRETE STRENGTH: PROVISIONS OF THE EUROPEAN AND ITALIAN SEISMIC CODES

Investigation of Natural Plasticizers in Concrete

STRENGTHENING OF INFILL MASONRY WALLS USING BONDO GRIDS WITH POLYUREA

RENOVATION OF A NATIONAL MONUMENT IN HUNGARY: THE KEREPESI GRANDSTAND

NLFEA Fire Resistance of 3D System Ceiling Panel

Behavior of Steel Fiber Reinforced Concrete for M-25 Grade

ABSTRACT. KEY WORDS: Tubular piles; composite behavior; offshore structures; push-out strength; bond strength; slip.

CONCREEP 10. September 21-23, 2015 Vienna, Austria. SPONSORED BY RILEM Engineering Mechanics Institute of ASCE

BEHAVIOR OF REINFORCED CONCRETE BEAM WITH OPENING

Service life extension of existing precast concrete girders

Transcription:

IOSR Journal of Mechanical & Civil Engineering (IOSR-JMCE) ISSN: 2278-1684, PP: 37-42 www.iosrjournals.org Health Assessment Of Reinforced Concrete Structures - A Case Study Prof. Dr.D.K.Kulkarni. Professor, Civil Engineering Deptt, S.D.M College of Engg. And Technology. Dharwad, Karnataka-India. Mr. Teke Sudhakar. S. Research Scholar, Civil Engineering Deptt. I.C.R.E, Gargoti-416209,Dist-Kolhapur, Maharastra-India. ABSTRACT: It is often necessary to test concrete structure to determine its suitability for which it is designed. Ideally such testing should be done without damaging the concrete. The test available for testing concrete range from the completely non-destructive, where there is no damage to the concrete, through those where the concrete surface is slightly damaged, to partially destructive tests, such as core tests and pullout and pull off tests, where the surface has to be repaired after the test. The range of properties that can be assessed using nondestructive tests and partially destructive tests is quite large and includes such fundamental parameters as density, elastic modulus and strength as well as surface hardness and surface absorption, and reinforcement location, size and distance from the surface. As is been worked on assessment of in place concrete strength of R.C.C residential buildings of different age groups and elevated storage reservoirs of ages 25 yrs.and 30 yrs. respectively, it is been found that the use of NDT techniques are much reliable and can well be fit to assess the quality of concrete structures. In this paper the field investigation for strength assessment and hence resolving the doubts of quality of construction of an existing structure has been presented based upon nondestructive testing. 1. INTRODUCTION Any structure that is in use for which it is intended to, shows some structural disorder, requires to be assessed for its quality, structural integrity and in place concrete compressive strength. Standing structure can not be assessed by conventional methods adopted to evaluate structural integrity and in place concrete compressive strength same as by testing standard specimens up to failure. Hence for structures, standing decades together, an efficient system of assessment of structure for in place strength is urgently required. It is also true to the new structures, as more and more clients and their consultants are well aware of the quality assurance in booming infrastructure sector in India. Non Destructive Testing ( NDT ) has the potential of becoming an effective tool for quality assurance and damage assessment. 2. NON-DESTRUCTIVE METHODS The objective of a non destructive test is to obtain an estimate of properties of material by measuring certain quantities which are empirically related to it. To make a strength estimation, it is necessary to know the relationship between the result of the non destructive test and strength of material. The accuracy of interpretation of results depends directly on the correlation between strength of material and measured quantity. Thus, the user of NDT should have an understanding of what quantity is measured by the test and how this quantity is related to the strength of material. Test methods range widely in reliability and complexity. Hence, appropriate experience is necessary in selection of the proper tests and correct interpretation. The following NDT techniques are generally employed - 1. Schmidt s Rebound Hammer test for assessing the concrete compressive strength. 2. Ultrasound pulse Velocity tests for establishing quality of concrete. 3. Coring for taking out concrete cores for laboratory testing for determining compressive strength. 4. Rebar locator tests for locating reinforcement bars and for determining their diameters and spacing. 5. Carbonation test for determining the depth of carbonation of concrete. 6. Half- cell potential test for determining the likelihood of corrosion. 7. Determination of chloride contents of concrete In the present paper, health assessment methods such as A) Rebound Hammer and B) Ultrasonic Pulse Velocity are closely scrutinized to explore some fundamental aspects of R. C. structure health monitoring. 37 Page

Health Assessment Of Reinforced Concrete Structures - A Case Study 2.1 Rebound Hammer Method This method is explained in IS:13311 (part2):1992. Principle of test: When the plunger of the rebound test hammer is pressed against the surface of the concrete the spring controlled mass rebounds and the extent of such rebounds depends upon surface hardness of the concrete. The rebound is then be related to the compressive strength of concrete. Factors affecting the Rebound Number i. Type of cement ii. Type of aggregate iii. Concrete moisture condition iv. Curing and age of concrete v. Presence of surface carbonation etc. 2.2 Ultrasonic Pulse Velocity This method is explained in IS 13311 (part 1):1992, which involves measurement of the time of travel of electronically generated mechanical pulses through the concrete. The ultrasonic pulse velocity method could be used to establish: a) Homogeneity of concrete b) Presence of cracks & voids c) Changes in structures of the concrete d) The quality of the concrete in relation to standard requirement e) The values of dynamic elastic modulus of the concrete The principles behind the Ultrasonic Pulse Velocity is that the pulses are generated by an electroacoustical transducer, when pulse is induced into the concrete from a transducer, it undergoes multiple reflections at the boundaries of different material phase within the concrete. A complex system of waves is developed which include longitudinal, shear and surface waves. The receiving transducer detects the onset of longitudinal waves which is the fastest. Because the velocity of the pulses is independent of the geometry of the material through which they pass and depends only on its elastic properties. When quality of concrete in terms of density, homogeneity and uniformity is good, higher velocities are obtained. In case of poorer quality of concrete lower velocities are obtained. In general the velocity criterion are as shown in table No.1. Table No.1. Sr. No Pulse Velocity ( Km/sec) Concrete Quality Grading 1. Above 4.5 Excellent 2. 3.5 to 4.5 Good 3. 3.0 to 3.5 Medium 4. Below 3.0 Doubtful Factors affecting the pulse velocity i. Surface condition and moisture content ii. Temperature of concrete iii. Micro cracks in concrete iv. Water cement ratio v. Age of concrete vi. Presence of steel reinforcement vii. Type of aggregate 3. CASE STUDY 3.1 General Information In a prime locality of Gargoti, (kolhapur) a G + II storied institute building was under construction a couple of years before. The grade of concrete used was M20. The floor system consisted of beam slab construction. Part of the first floor slab and beams were cast on a particular day. The cube test results yielded lower values and the concrete failed to achieve the acceptance criteria. It was decided to perform nondestructive tests to estimate the properties of concrete in the structure. Non-destructive tests provide alternatives to core tests for estimating the strength of concrete in a structure, or can supplement the data obtained from a limited number of cores. These methods are based on measuring a concrete property that bears some 38 Page

Health Assessment Of Reinforced Concrete Structures - A Case Study relationship to strength. The accuracy of these methods, in part, is determined by the degree of correlation between strength and the physical quality measured by the non-destructive tests. 3.2 Scope of work The quality of the concrete was to be evaluated by performing Non-destructive Testing. In order to assess the quality of concrete, the following methods of testing were employed: (i) Ultrasonic Pulse Velocity test as per IS:13311 (Part 1). (ii) Rebound Hammer test as per IS:13311 (Part 2) 3.3 Visual Inspection & Selection of Spots for Testing. Ultrasonic Pulse Velocity test :- ( Fig. 1. ) Fig. 1. Rebound Hammer test :- (Fig.2 ) Fig. 2. Apparently no abnormality in concreting was observed at the 1 st floor. At different parts of the floor slab and beam, spots were selected for performing the NDT work. Rebound Hammer tests were performed on the floor slab by holding the hammer vertically down. Readings were taken also on beam sides with direction of hammer horizontal. All these locations were assessed by USPV tester. Majority of the observations were surfaces probing whereas for beam sides cross probing was adopted. 3.4 Summary of Observations & Interpretation of Results In view of the limitations of the methods for predicting the strength of concrete in the structure, it is preferable that both ultrasonic pulse velocity and rebound hammer methods be used in combination to alleviate the errors arising out of influence of material, mix and environmental parameters on the respective measurements. Relationships between pulse velocity, rebound number and compressive strength of concrete are obtained by regression analysis of the measured values on laboratory test specimen. For the structure under investigation a detailed NDT scheme was adopted and the summery of observation is mentioned below- Concrete at 1 st floor level Rebound Hammer & USPV readings were noted at 10 spots on a number of slab panels and beams. Jist of observation on 1 st floor Slab and beams Rebound Hammer Direction of hammer i.e. held vertically downwards Rebound index = 23.17 Direction of Hammer i.e. held horizontal Rebound index= 33.84 USPV- USPV (surfaces) = 2.05 km/s USPV (cross) = 4.1 km/s 39 Page

COMPRESSIVE STRENGTH ( N/mm2) --- COMPRESSIVE STRENGTH ( N/mm2) --- Health Assessment Of Reinforced Concrete Structures - A Case Study 3.5 Correlation Between compressive Strength of concrete & NDT Parameters viz. Rebound Index & USPV In an attempt to develop correlation between USPV & Rebound index with compressive strength, cubes were casted of same grades and cured and left to meet with the site conditions. A total of 4 cubes each of M20 Grades concrete were obtained for testing in the laboratory. As per IS:13311 (part 2), the cubes were tested by Rebound hammer by holding them in compression testing machine under a fixed load of 7 N/mm 2. Rebound Number or indices for horizontal position were obtained. About 9 readings on each of the two faces of the cubes were noted. Values of Rebound indices, USPV and compressive strengths of the cubes are presented in table 2. Table 2: Results of Destructive and Non-destructive tests on cube specimens. Grade of Rebound Hammer USPV Results (km/s) Compressive Strength (Mpa) concrete Hammer Direction ( ) Cross Probing Compressive Strength (Mpa) M 20 29.06 4.02 27.08 M 20 30.35 4.1 2 31.73 M 20 29.78 4.21 32.14 M 20 31.18 4.17 30.52 Based on the procedure outlined in Is-13311 (part 1) and (part 2) relationships between compressive strength and USPV and Rebound numbers have been developed using regression shown in figures 3 to 4. from the relevant correlation curves, most likely cube compressive strength of concrete has been obtained after allowing for necessary corrections. HAMMER REBOUND NO. Fig. 3 HAMMER REBOUND NUMBER --- 10 2 3 4 5 ULTRASONIC PULSE VELOCITY (Km/sec)--- Fig. 4. Using these relationships, the compressive strengths of concrete have been evaluated from the observations taken on the actual structure. 3.5.1 Compressive Strength from Rebound indices 1 st Floor concrete, Grade adopted M20 Average value of Rebound number with hammer held horizontal = 33.84( ) 40 Page

COMPRESSIVE STRENGTH ( N/mm2) --- COMPRESSIVE STRENGTH ( N/mm2) --- Health Assessment Of Reinforced Concrete Structures - A Case Study From the correlation developed between rebound numbers and compressive strength, compressive strength was obtained as 32.58 MPa. ( Fig. 5.) 32.58 33.84 HAMMER REBOUND NUMBER --- Fig. 5. 3.5.2 Compressive Strength from USPV Observations on concrete at 1 st floor level The average value of USPV for cross probing of 1 st floor concrete was obtained as 4.1 km/s which as per IS:13311 (part 1) can be considered as good quality concrete. From the correlation developed between USPV and compressive strength, compressive strength was obtained as 30 MPa. ( Fig. 6. ) 30 10 4.1 2 3 4 5 ULTRASONIC PULSE VELOCITY (Km/sec)--- Fig. 6. 3.6 Comparison of Strength Results from Existing Models / Relationship A classical example of this application is the SONREB method, developed largely due to the efforts of RILEM technical committees 7 NDT and 43 CND and under the chairmanship of facaoaru has been adopted in Romania. A general relationship between compressive strength of concrete, rebound hammer number, and ultrasonic pulse velocity. In accordance with the tentative recommendations for in-situ concrete strength estimation by combined non-destructive methods, RILEM committee TC 43 CND, 1983, forms the basis of SONREB technique. this relationship is in the form of a nomogram. By knowing the rebound number and pulse velocity, the compressive strength is estimated. Based on the correlations developed between the Non-destructive parameters and compressive strength the most likely compressive strength of concrete at the 1 st floor is mentioned here. Estimated compressive strength of concrete investigated at 1 st floor level (beams & slabs has been obtained as 32.58 MPa from rebound indices which becomes as 22.80MPa when age correction factor is applied ( Age correction factor = 0.7 for 300 days) and 30 MPa from USPV. For the building under consideration, the estimated value of the compressive strength as obtained from the nomogram ( Fig. 7. ) on the basis of values of rebound index ( 33.84) and USPV ( 4.1 Km/sec.) is 23 MPa. This value is well in agreement with the values obtained by statistical correlations developed from specimens tested in the laboratory. 41 Page

Health Assessment Of Reinforced Concrete Structures - A Case Study Fig. 7. ISO- Strength Curves for reference concrete in SONREB method. 4. CONCLUSION Health assessment work may be performed on new structures if concrete fails to attain the desired strength at 28 days age. This case study deals with the health assessment work where the strength of the concrete existing in a new structure was ascertained by developing statistical correlation between NDT properties and compressive strength of concrete as per IS: 13311. REFERENCES 1) S. Watanabe and Sudhir Mishra., Non Destructive Evaluation of Concrete Structures A case study in detailed inspection using 24-year old Reinforced Concrete, Non Destructive Testing in Civil Engineering 2003, International Symposium, pp 24-27. 2) T. Parhizkar and Ali Akbar Ramezanianpour., The Role of Non Destructive Tests for Evaluation of a Concrete Structure A Case Study, Non Destructive Testing in Civil Engineering 2003, International symposium, pp 24-27. 3) Dr. S. K. Kaushik, ( 2005 ) Non destructive testing in civil engineering, New Building Materials & Construction World October,2005, pp 40-64 4) Atul K. Desai, Krupesh A. Chauhan and Dr. N. C. Shah., Method of health monitoring of structures and diagnostic medicine, Civil Engineering And Construction review-may,2008, pp 42-50. 5) Kaushal Kishore., Testing concrete for cement content, water content and ph value. Civil Engineering And Construction review April,2008, pp 54-59.Dr. M. Verman., Non Destructive Testing For Damage Assessment of Civil Engineering Structures, Instrumentation and Non Destructive Testing Civil Engineering and Construction Review, Vol. 21, No.4, April,2008, pp 26-36. 6) Dr S.K.Dubey (2009 ), Strength Assessment of Concrete Structures By Non- Destructive Testing, New Building Materials & Construction World December,2009, pp 208-217.Dr.Santanu Bhanja., Health Assessment Of Reinforced Concrete Structures- Case Studies, New Building Materials & Construction World February,2010, pp 111-125. 7) Method of Non-destructive Testing of Concrete Ultrasonic Pulse Velocity, IS: 13311 pt.1 (1992), BIS, New Delhi. 8) Method of Non-destructive Testing of Concrete Rebound Hammer, IS: 13311 pt.2 (1992), BIS, New Delhi. 9) Indian Standard Code Of Practice For Plane Reinforced Concrete Structures. IS: 456 (2000), Bureau of Indian Standards, New Delhi. 10) Guidebook on non-destructive testing of concrete structure, International Atomic Energy Agency, Vienna, 2002. 42 Page