VESDURA VINYL PLANKS 7.5MM WPC CLICK LOCK - AMERICANA COLLECTION

Similar documents
Installation Procedure of Floating floors

INSTALLATION INSTRUCTIONS

Concrete 1,8 2,0 Anidrite 0,3 0,5

HYBRID. Pre-Laying Checks

COMPOSITE (WPC) ENGINEERED VINYL FLOORING INSTALLATION

SPECTRA CLICK RESILIENT VINYL PLANK INSTALLATION GUIDELINES

ENGINEERED LUXURY VINYL GENERAL INSTALLATION INSTRUCTIONS FOR ANGLE-TO-ANGLE FLOORING

LUXURY VINYL GENERAL INSTALLATION INSTRUCTIONS FOR LOCKING FLOORING

USA USA USA PURE CLICK

ENGINEERED WATERPROOF FLOORING GENERAL INSTALLATION INSTRUCTIONS FOR VÄLINGE 2G LOCKING FLOORING

General Commercial Installation Guide LAMINATE

INSTALLATION INSTRUCTION BJOORN PARQUET PARALLEL ROWS

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

CLICK TOGETHER ENGINEERED LONGSTRIP HARDWOOD FLOORING CLICK TOGETHER CORK FLOORING CLICK TOGETHER BAMBOO FLOORING

UNDERLAYMENT INSTALLATION INSTRUCTIONS

ANTIQUED SOLID / SOLID HARDWOOD

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

FlexLok Adhesive Tabs for Carpet Tile

Bentley. Lifetime. 5yr Lt.

Technical Service. INSTALLATION INSTRUCTIONS FOR TARAFLEX SPORT PRODUCTS over Gypsum base Products. This document refers to the following products:

TILE TILE

DURABASE CI 1/5. Underlay mats for decoupling and waterproofing tiled flooring APPLICATIONS AND FUNCTION.

SELECT SURFACES LAMINATE FLOORING INSTALLATION GUIDE DRIFTWOOD

GLUE-DOWN INSTALLATION VIRTUO 30 / 55

RAUPEX SPEED SYSTEM Installation Guide

WATER TUFF VINYL FLOORING ATTENTION! READ BEFORE INSTALLING! Angle-Tap Installation Instructions

Commercial Resilient Sheet Flooring

BOLON BY YOU INSTALLATION INSTRUCTIONS ROLLS

STEP UP SHOWER BASE INSTALLATION GUIDE FOR TIMBER AND CONCRETE FLOORS

SUBFLOOR AND INSTALLATION PREPARATION INSTRUCTIONS

Section III Installation Guidelines & Methods Page Chapter 7 Parquet Installation 30 Chapter 8 Engineered Wood Flooring Installation 34 Chapter 9

Channel Drain Shower Base. Aqua Line pro. Installation Instructions

1. Division 09 Section "Rough Carpentry."

WOOD FLOORING WOOD FLOORING

FLOORING FOR FLOOD-PRONE AREAS. Vinyl Flooring. Pros of Vinyl Flooring for Flood-Prone Areas

Product Width Thickness Installation direction Seam treatment. Taraflex Sport M Comfort Approximately mm + 5mm Same Heat Welded

Section II Subfloor Guidelines & Specifications Page Chapter 4 Wood Subfloor Guidelines 23 Chapter 5 Concrete Subfloor Guidelines 26 Chapter 6

INSTALLATION INSTRUCTION BJOORN PARQUET HERRINGBONE

DURABASE CI. Underlay mats for decoupling and sealing tiled flooring 1/5 A P P L I C A T I ONS AND FUNCTION.

Carpet Tile & Plank Direct Glue Down

ATTENTION! READ BEFORE INSTALLING!

Container Installation Guide

Installation Guide LVP Glue Down

DeZign Glue Down Luxury Vinyl

Tufted and Woven Goods Direct Glue-Down

INSTALLATION INSTRUCTIONS

Installation Instruction

RESILIENT FLOORING: Hot and Heavy - Secoya

safari installation instructions

Footfall sound dampening system for wood flooring

High viscous (thixotropic) elastic adhesive for wood flooring

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

Installation Guide. PrivacyShield Outdoor Enclosure

BLUE FOREST Flooring Installation Instructions

Infinity Modular/Infinity Modular RE Carpet Tile Installation Guidelines

INSTALLATION GUIDELINES Signature Naturals PureForm Solid Strip Bamboo Flooring

Warmup helpline:

SECTION PREFINISHED FSC MAPLE FLOORING. This is a template: edit this specification carefully to suit specific project requirements.

Floors. Allwood Floors 5/8" & 9/16" Floating Floors For Staple-Down or Glue-Down Installations. Installer/Owner Responsibility

HAND-SCRAPED FLOORING INSTALLATION INSTRUCTIONS

INSTALLATION GUIDELINES PREFINISHED SOLID & ENGINEERED WOOD

PURE INSTALLATION MANUAL

RADIANT PANEL SYSTEM PLANNING & INSTALLATION. Roth Radiant Heating Systems

Container Installation Guide

ENGINEERED. 12mm engineered hardwood flooring INSTALLATION INSTRUCTIONS

RAUPANEL DRY SYSTEM HIGH PERFORMANCE PANEL SYSTEM

TB 2. Installation of Multilayer Modular Floor Coverings (MMF)

9.5, 10, 10.5 & 12mm. Product Use & Installation Options. Engineered hardwood flooring INSTALLATION INSTRUCTIONS

CONNOR Control XT Page 1

MILLTOWN. Product Use & Installation Options. 12mm engineered hardwood flooring INSTALLATION INSTRUCTIONS

BioPrism Solid Surface

GUIDE SPECIFICATIONS IN CSI FORMAT: RESILIENT FLOORING

Installation & Maintenance Guide

HAWORTH PORCELAIN FLOORING SYSTEM CSI Specifications 03/29/2017. A. Concrete work and concrete floor sealer is specified in Section

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

Freedom One-Piece Barrier Free Showers Installation Instructions

RESILIENT FLOORING: Select Step Wood

INSTALLATION INSTRUCTIONS

SECTION RESILIENT SHEET FLOORING

IVC US Commercial Installation Guide - LVT. Leading the Way

Subfloor heating and cooling instructions for Hakwood flooring products Duoplank 20mm (¾ ) and Duoplank 15mm (⅝ )

GUIDE SPECIFICATION

STORAGE AND TRANSPORTION

INSTALLATION GUIDELINES The following instructions shall be reviewed prior to installation. Shaw will not be responsible for improper installation.

Glue. Wood Flooring. to a. Concrete Slab FINE HOMEBUILDING

COMMERCIAL INSTALLATION GUIDE

SECTION GYPSUM CEMENT UNDERLAYMENT RECOMMENDED SPECIFICATION FOR DURA-CAP FLOOR UNDERLAYMENT OVER EXTRUDED OR EXPANDED POLYSTYRENE FOAM

Specification Data -- RESILIENT TILE FLOORING

ACOUSTIC INSULATION DIRECTLY UNDER FLOOR COVERINGS made from recycled rubber

DURABASE. Systems for decoupling, sealing, drainage, sound and heat insulation. Systematic underlays. WP page 4/5. CI++ page 2/3. DD page 6.

Modular Coldroom Installation Manual

Installation and Maintenance

CONTRACT PAGE 1 OF 5

INSTALLATION INSTRUCTIONS 2G DA VINCI LVT

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

Construction. Solvent free elastic adhesive for Wood Flooring. Product Description. Product Data Sheet Edition _1. 1 SikaBond -52 Parquet 1/6

INSTALLATION INSTRUCTIONS FOR GERFLOR TARASAFE ULTRA VINYL SHEETGOODS

Installation of Large Format Tile & Stone

HOW TO: BOARD ROOMS WITH HIGH HUMIDITY AND CONDENSATION GTEC MOISTURE AND VAPOUR BOARD WITH PLASTERBOARD

B. Related Sections: 1. Division 07 Section "Joint Sealants" for sealing of expansion, contraction, control, and isolation joints in tile surfaces.

Transcription:

VESDURA VINYL PLANKS 7.5MM WPC CLICK LOCK - AMERICANA COLLECTION Before You Start Click lock vinyl plank flooring is normally laid without adhesive. Before installation, planks must be allowed to acclimatize to the room conditions. For that purpose, the original packages shall be horizontally stored unopened full-area supported n groups of 4-5 for at least 48 hours in the room with normal temperature conditions. Make sure that temperature in the room of installation lies between 18 C and 25 C. Relative humidity should lie between 40%-65% (minimum and maximum values, respectively). Both limit values must also be maintained during installation and afterwards, in the course of regular living use. Subfloor temperature must be at least 15ºC. To avoid damage to the product, handle packages carefully and open them just prior to installation. Vinyl plank flooring provides a very close fit. Very little force is required to lay the floor. An unprofessional installation can result in damage to the click profile. Check the vinyl plank flooring for possible defects prior the installation. Complaints can only be accepted before installation. Slight variations in color and structure are designed to enhance natural appearance. Mixing the sheets creates a uniform laying pattern. Sub Floors 1. The subfloor must be constructed properly clean, dry, sound and flat. Any bumps caused by paint or plaster drops etc. must be removed. Vinyl plank flooring can be installed on existing firm floors (Linoleum, PVC), but all textile floors must be removed. When laying the floor on tiles, fill the gaps with grout to make the surface smooth. 2. Vinyl plank flooring is not sensitive to moisture, but for building biological reasons the permitted moisture content according to CM-method for concrete slabs must be < 2.0 % CM (radiant heated 1.8 % CM), for anhydrite slabs: < 0.3 % CM (radiant heated 0,3 % CM). Unevenness in the subfloor may not exceed 4 mm (1/6 ) at a measure-distance of 1 m (3 1/4 ) (DIN 18202, table 3, line 3). 3. Vinyl plank flooring is already quiet to walk on. Additional noise reduction is only possible using specialist materials. 4. Installation over sub floor heating - some important issues: a. Max allowed temperature on top of the vinyl plank flooring is 28 C. Please note that normal loose carpets insulate i.e. increase the floor surface temperature about 2 C! b. Important: Follow the heating regulation recommendations given by the system supplier. c. Separate floor areas not having sub floor heating with expansion joints. Measurements Agree with the client on which direction the floor boards should run since this influences the visual size ratio of the space. Installation parallel to the longest wall or the main light-source is recommended for best visual effects. Pre-plan the floor by measuring the room first. If the width of the last row is less than 5 cm (2 ) saw the first and the last plank in equal width. For larger areas of flooring expansion space from the building site always must be taken on. Otherwise place expansion space in room-narrowings and in the door-rebate. Cover the expansion space with suitable coverings. Page 1

VINYL INSTALLATION INSTRUCTIONS Fig 1. First plank, first row. Place a distance 10 mm thickness to the left and position the plank against the wall. Later, after 3 rows, you can easily position the flooring against the front wall with distances 10 mm. Fig 2. Insert the end section of the next floorboard at an angle to the first one, then lay down. Complete the first row in the same manner. Fig 3. At the end of the first row, put a distance 10 mm, to the wall and measure the length of the last plank to fit. Page 2

Fig 4. Cut with a jig saw, WPC turned down or with a hand saw with the WPC visible. Fig 5. Second row. First plank min length 500 mm. Put a distance against the wall. Fig 6. Place the floorboard at an angle against the floorboard in the previous row, press forward and fold down at the same time. Page 3

Fig 7. Place the short end of the floorboard at an angle against the previous installed floorboard and fold down. Ensure that the board is positioned in the integral locking strip of the floorboard in the previous row. Fig 8. Lift both the current as well as the previous plank from this row, push to slide the current plank against the row in front so it aligns with the previous plank. The current and previous plank can now be folded completely down to horizontal position. Fig 9. After 2-3 rows. Adjust the distance to the front wall by placing distances 10 mm. Page 4

Fig 10. Last row (and perhaps also first row). Minimum width 50 mm. Remember distance to wall 10 mm. Tip! Put a distance before measuring. Cut the panels lengthwise and glue the short ends. Small Panel Widths Joining at short ends length cut plank. Cut the tongue at the same time you cut the length of the plank and install as shown above. Please note that the smallest width of a plank is ca 50 mm at the last row if not - first row must be adjusted. This can easily be calculated when measuring the room with before installation! Horizontal Installation Cut off the locking element with a chisel, push the planks horizontally together. If necessary, place some distances between the last panel and the wall to keep the planks together during the curing time of the glue Radiator Pipes Installation at radiators. Drill the holes 20 mm larger than the diameter of the pipes. Page 5

Radiant Heated Sub Floors Vinyl plank flooring can also be installed on a radiant heated subfloor. Special installation instructions concerning the subfloor must be followed. Page 6