The Open Air Office Climatic adaptation of the office building typology in the Mediterranean

Similar documents
681: Environmentally Responsive Architecture; Passive Design for School in Southern India

A Case Study on the Daylighting and Thermal Effects of Fixed and Motorized Light Louvers

HOW CURRENT TRENDS IN THE DESIGN OF FACADES INFLUENCE THE FUNCTIONAL QUALITY OF INTERIOR SPACES

Nearly Zero Energy Building in Lecco Modern technological building compared to an ancient Villa

Designing carbon neutral schools: The Victor Miller Building, a critical review

The effect of shading design and control on building cooling demand

Assessment of the energy demand in energy-saving office buildings from the viewpoint of variations of internal heat gains

Assessment of shading devices with integrated PV for efficient energy use

Deakin Research Online

ENERGY PERFORMANCE OF DIFFERENT TYPES OF DOUBLE SKIN FACADES IN VARIOUS CLIMATES

Energy-Efficient Passive House using thermal mass to achieve high thermal comfort

Thermal Delight in Architecture

THERMAL MASS CHAPTER 6. Understanding thermal mass. Seasonal effects of thermal mass

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

BUILDING DESIGN FOR HOT AND HUMID CLIMATES IMPLICATIONS ON THERMAL COMFORT AND ENERGY EFFICIENCY. Dr Mirek Piechowski 1, Adrian Rowe 1

POST OCCUPANCY DESIGN INERVENTION TO IMPROVE COMFORT AND ENERGY PERFORMANCE IN A DESERT HOUSE

Facade Design for Super High- Rise Building in Subtropic Region in China

Using passive solutions to improve thermal summer comfort in timber framed houses in South-west France

Effects of Fixed and Motorized Window Louvers on the Daylighting and Thermal Performance of Open-Plan Office Buildings

Student Modeling Competition

Thermal Comfort & Green Buildings. Dr. Ommid Saberi. "Green Retrofit Conference. WSP Environment & Energy (Middle East)

Case study the Vela Roof UNIPOL, Bologna Use of on-site climate and energy resources

Bruck an der Mur. Project summary. Energy concept: Background for the renovation reasons

Design Strategies and Guide lines for Tropical Coast of Pakistan, Using Climate Consultant

A STUDY OF DAYLIGHTING TECHNIQUES AND THEIR ENERGY IMPLICATIONS USING A DESIGNER FRIENDLY SIMULATION SOFTWARE

Comparative Performance of Internal Venetian Blind and Roller Blind with Respects to Indoor Illumination Levels

Is Your Envelope Effective? BCBEC Luncheon January 29, 2009

Thermal Delight in Architecture

COMFEN A COMMERCIAL FENESTRATION/FAÇADE DESIGN TOOL

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

INTEGRAL BUILDING AND ENERGY DESIGN OF AN OFFICE BUILDING COMPARISON OF INITIAL DESIGN IDEAS WITH MONITORED RESULTS

A parametric study of the energy performance of double-skin façades in climatic conditions of Crete, Greece

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

optimize daylighting Opportunities

Thermal Bridging and Whole Building Energy Performance

COMPARISION OF FIVE WINDOW SHADE STRATEGIES

Iconography. KAPSARC Mosque

OPTIMIZATION OF WINDOW-WALL RATIO FOR DIFFERENT BUILDING TYPES

A Comparative Analysis On The Effect Of Double- Skin Façade Typologies On Overall Building Energy Consumption Performance In A Temperate Climate

SUMMER THERMAL COMFORT IN TYPICAL FRENCH RESIDENTIAL BUILDINGS: IMPACT ASSESSMENT OF BUILDING ENVELOPE INSULATION ENHANCEMENT

Solar Shading System Based on Daylight Directing Glass Lamellas

Thermal Comfort in Architecture

SageGlass. SageGlass Product Guide. Dynamic glass for a changing world

Sustainable Building Design and Renewable Applications

Daylight, Solar Gains and Overheating Studies in a Glazed Office Building

5.0 Daylighting Analysis (Breathe Study)

ARCH 5901 A02 Office Building Program FALL 2015

Using Radiant Cooled Floors to Condition Large Spaces and Maintain Comfort Conditions

PLANNING SUSTAINABLE IN CHINESE CITIES: DWELLING TYPES AS A MEANS TO ACCESSING POTENTIAL IMPROVEMENTS IN ENERGY EFFICIENCY

Smart. Easy. Profitable.

Energy Audit of two Apartment Buildings in Cagliari using Energy Simulation

Solar Energy Technologies

DESIGN AND SIMULATION WORKFLOW OF AN OFFICE BUILDING IN NEW DELHI, INDIA

Evaluating Appropriate Residential Ventilation Strategies in Dense Urban Environments and the Challenges for Passive Design

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

Bioclimatic Design Approach Integration into Architectural Design: a Library Case Study

Work Package 2: Performance of naturally ventilated buildings

IBP FRAUNHOFER INSTITUTE FOR BUILDING PHYSICS IBP ENERGY SYSTEMS

Solar Home Design and Thermal Mass

ARPAN JOHARI. Architect. 13/08/10 AW Design. Ahmedabad

Effect of Building Shape And Neighborhood Design On Solar Potential And Energy Performance

COMMERCIAL LOAD ESTIMATING. Load Estimating Level 3: Block and Zone Loads. Technical Development Program

Flexibility in typology, technology, construction and performances: an innovative approach for an open construction kit

Capturing the Stakeholder Values of a Construction Project

ARCH-MEDES (I) CONSULTANTS PVT. LTD. Green Park Delhi

! #! %%%%&%%% &( &% )) + # +,% #.!. # 0! 1 2! ,%,% 0 # 0! 1 2! ,4&,) 5,%

Energy Efficient Buildings in Germany An Introduction

Whole Building Energy Analysis using BIM

Procedia - Social and Behavioral Sciences 222 ( 2016 )

Transformable Design Methods

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Energy System Design and Optimization of a Solar Decathlon House

OFSETTING THE NATURE

Impact of increasing the depth of urban street canyons on building heating and cooling loads in Tel Aviv, Israel

Green Building Guideline of Jordan

SOLAR PHOTOVOLTAIC ASI GLASS E. ASI Glass. Integrated Architecture Powered by the Sun

Great Ocean Rd Ice Creamery

Chapter 5 Glazing Properties

Climate Analysis. Daylighting uses solar angles, cloud cover/precipitation, and context. Temperature. Humidity. Precipitation. Wind.

Field investigation on indoor thermal environment of a high-rise condominium in hot-humid climate of Bangkok, Thailand

GIFT 6th of August Trends in financial services buildings internationally. Pierre Jaboyedoff Effin Art

LEED v4 Building Design and Construction Quiz #8 EQ

The Effects of Set-Points and Dead-Bands of the HVAC System on the Energy Consumption and Occupant Thermal Comfort

Passive Houses in South West Europe

Bioclimatic approaches of modern residential architecture in Cyprus,

Pearl River Tower. Guangzhou, China. AEI Professional Project Awards January 2014 PHOTO CREDIT: TIM GRIFFITH

Available online at ScienceDirect. Energy Procedia 91 (2016 )

Available online at ScienceDirect. Energy Procedia 57 (2014 )

Effect of a Window Shade on Home Energy Use

Building performance analysis for double skin residential buildings ABSTRACT BACKGROUND. Porooshat Akhgari

DEVELOPMENT AND CONSTRUCTION OF BIOCLIMATIC DOUBLE SKIN ACTIVE FACADE FOR HOT AND HUMID CLIMATE OF UAE

Optimization of air tightness and night ventilation for Passive houses in Italian climates under Fanger and Adaptive comfort models

Extended pilot study of an energy efficient glazed office building during pre-design and design. Åke Blomsterberg (WSP och LTH)

This is the accepted manuscript version of the article

Passive cooling and energy conservation design strategies of school buildings in hot, arid region: Riyadh, Saudi Arabia

Fall 2013 Re-Making the Future. Annie Ranttila. Hazelwood Climate Analysis

INFLUENCE OF HIGH PERFORMANCE FAÇADE ON HEATING/COOLING LOAD IN OFFICE BUILDINGS IN LONDON AND HONGKONG

C H A P T E R 3. Completing the Residential Analysis Worksheet STEP 1: WINDOWS AND OTHER GLASS AREAS

Transcription:

The Open Air Office Climatic adaptation of the office building typology in the Mediterranean JONATHAN NATANIAN (MSc) Technion Israel Institute of Technology leyonatan@gmail.com ASTRACT The paper reports on a dissertation project undertaken at the Architectural Association School of architecture towards a Master s degree in Sustainable Environmental Design by the Author. The starting point for the research was the troubling common practice of office buildings in Israel - racing towards the tallest, highly mechanical and fully glazed buildings, scarcely applying any environmental considerations and occasionally using the local green point system code to render them as green. This research aims at contextualizing the office building typology to the local Mediterranean climatic conditions of Israel; based on a theoretical framework and a detailed study of local common practices and climate, followed by an analytic optimization study, the Open Air Office concept is introduced: one which uses an integrated environmental design approach to rethink some of the core values that drive office building designs in Israel today. INTRODUCATION Adoption without adaptation In contrast to a history of successful adaptations of international building styles in Israel which demonstrated high sensitivity towards the local climate, the adoption of the fully glazed office building typology in Israel- mostly throughout the late 80's and 90's- has been almost automatic (Figure 1), with very little awareness towards the environmental impacts of these buildings on all levels - from the cityscape to the occupant. (1) Figure 1 Gradual abandonment of climatic considerations throughout the history of Israeli Architecture. (Source, left to right: Le Corbusier, author s sketch, Arieh Sharon, Emporis, and Telavivinf.com) Jonathan Natanian is a Teaching Fellow in the Faculty of Architecture and Town Planning, Technion Israel Institute of Technology, Haifa, Israel. 1

Starting from evaluating the performance challenges of this common practice in Israel against the potentials of the local climate, this research began by questioning how to improve performance by taking simple considerations into account in the early stages of office buildings design in Israel; using the common practice as a base case this study gradually explored the possibilities of optimizing both comfort and efficiency by applying preliminary, good and further on best practice environmental strategies that fit Israel s climatic conditions. In conclusion, this research aimed at offering a platform for architectural design that will give a new angle to the correlation between the contemporary indoor office space and the local climate. Methodology Firstly, a study was conducted on new global workplace trends and explored the potential of new occupancy patterns to affect both comfort and performance levels of office buildings in the near future. Secondly, the local climate of Israel was studied, followed by relevant basic and advanced environmental strategies evaluation. In order to study the existing context, combined literature and analytic work were used to help gather insights regarding the current performance, layout and materiality of the local common practice office building. These insights helped highlight specific challenges and potentials, so as to define the base cases towards further studies. The analytic work, which was focused on thermal, daylight and Solar geometry aspects, moved through different levels - from the simplest preliminary environmental concepts to more advanced ones, evaluating their potential to improve both efficiency and comfort levels within the typical office space; Simulations were conducted by using Tas (thermal, by EDSL), Ambiens (CFD, by EDSL), Radiance (Daylight, by Berkley lab) and Ecotect (solar geometry, by Autodesk) software. The last part of this research explored and analyzed the unique opportunity of the Mediterranean climate to open up the building s envelope towards the outdoors throughout different seasons of the year with correlation to the changing internal office layouts. The performance analysis for this Open Air concept, was followed by an applicability study of one possible office building configuration, which proved its potential to work very well with the local climate and office culture while providing high performance and comfort levels within the office space. THE FUTURE WORKSPACE Nowadays, in contrast to the prescribed tasks of the traditional office factory through single fixed workstations, the economic shift towards the knowledge society has created a need for variety of alternative spaces, with higher levels of interaction and autonomy (Harrison et al. 2004); As new technologies enable people to work virtually anywhere and new interaction between users within the office space through virtual computing (Johnson et al. 2011), a new office layout terminology has been evolved which encourage higher levels of flexibility, collaboration and autonomy (Duffy, 1997); The Israeli work culture, characterized by a vivid, creative informal atmosphere, with strong communal routs is highly exposed to global trends, which are commonly taken into account during the design process. Therefore, the future trends which shape workspaces globally served as an important anchor for this research. ISRAEL S OFFICE BUILDING DESIGN CULTURE Common practice design The research has focused on the climatic and urban context of the Tel Aviv metropolitan area, the economical center of Israel, due to its large conglomeration of office buildings. Building design. High rise office buildings are becoming common within the Central Business District of Tel Aviv. The Israeli market is highly speculative, predominated by Shell & Core buildings, being designed within a central core rectangular layout due to costs and internal space considerations. Materiality. Reinforced concrete frame & floor slabs is the prevailing framing method, cladding is usually done with different variations of curtain wall systems which combine glazing and opaque 2

cladding materials; Fully glazed buildings are very common and solar control is usually applied by reflective or tinted glazing systems combined with internal venetian or roller blinds. Office space layouts. The demand for enclosed private offices is still relatively high; the common practice consists of 4.5 deep office spaces with changing widths. Double-sided or single-sided open space offices are becoming more and more common, with depths ranging from 9m (single-sided) to as much as 30m (double sided); These observations helped generate the base case as shown in Figure 2. Performance criteria and benchmarks Although it is widely acknowledged (McKinsey and Co. 2009) that most buildings in Israel are big energy consumers, official energy consumption database or performance criteria for office buildings are currently unavailable. In order to establish a reliable reference point for the performance studies throughout the research, data was gathered from HVAC experts in Israel and was correlated with published cooling energy consumption data from similar climatic zones within the US. For this comparison, Tel Aviv climate had been considered as part of the A2 category (using ASHRAE international climatic zone definition) and energy consumption data of office buildings in Houston Texas was selected as a general reference. (2) (3) 4.5 m 9 m 15 m Figure 2 Common practice office space base case. Figure 3 Common practice energy cooling demand for 3 typical office layouts 1 (in kwh\m2, Source: TAS). Common practice performance Based on findings from the common practice design studies, three layout configurations have been modeled, as shown in Figure 2. The boundary conditions 1 for all the three base cases have been closely considered in regard to typical glazing, solar control, occupancy and materiality properties which have been identified as prevailing during the common practice studies. As a starting point, in order to establish a reference for further parametric optimization studies, a thermal simulation was conducted using TAS for the three different base cases facing West (or East West) orientation (a very common orientation for office buildings with proximity to the Israeli coastline). The combination of high exposure, together with their West-facing orientation, resulted in very high cooling energy demands across all three office layouts, mostly in cellular office layouts due to 1 Boundary condition in all cases included fully glazed 75% WWR designs, oriented West (or West-East orientation in double sided configuration), no external shading, w. internal semi opaque blinds. 3

their high window to floor ratio (Figure 3). These results were found to correlate well with the data gathered from the actual practice in Israel, in which HVAC systems are being designed to supply cooling energy of approximately 200 kwh/m 2 annually. ANALYTIC WORK - OPTIMIZATION PROCESS Preliminary optimization The first level of optimization was set up to explore the hypothesis that a high level of efficiency and comfort could be gained by applying very basic environmental design strategies at the very early design stages of office buildings. The parametric approach included four different strategies which were assessed separately (Figure 4), and were conclusively merged into different typical combinations according to the common office building design scenarios in Israel (Figure 5). Set point temperature. When considering the adaptive comfort model, the common fixation of the temperature set point on 23 o C or even lower during cooling period seems inappropriate. In order to test the implication of set point changes on performance, the three base case models were thermally simulated for three different set point temperatures (23, 25, 28 o C); Simulations showed how this simple operational change could substantially improve the annual cooling loads in all office layouts by 20-30%. Orientation. Thermal simulations for the three different layouts revealed large amplitudes in annual cooling energy demand between different orientations. In contrast to the Cellular base case which is more thermally fragile, open space layouts reacted more mildly, with the double sided model showing very limited performance effect by orientation. Shading. Different external shading geometries were simulated and studied in Ecotect for all four major orientations. After daylight levels had been verified through simulations (Radiance), selected optimized shading configuration were modeled thermally TAS. Window to wall ratio (WWR). This study explored the balance between minimizing exposure for thermal considerations while insuring adequate daylight levels for the 3 base case layouts through different orientations. (4) (5) (A) (A) (B) (C) (B) (C) Figure 4 Parametric optimization study of annual cooling energy demand for 3 typical office layouts (in kwh\m 2, Source: TAS). Figure 5 Annual cooling energy demand for different preliminary optimization scenarios (in kwh\m2, Source: TAS). Scenario A - Optimized configuration (A+B+C+D). Scenario B - Fully glazed configuration, all parameters applied besides the reduction in WWR (A+B+C). Scenario C - Sea View/Western configuration, all parameters applied besides optimized orientation (A+C+D). 4

Preliminary optimization. Figure 4 shows the effect of each of the parameters on the base case cooling energy demand; the chart demonstrates how orientation is critical for cellular offices (A); when oriented North, cellular offices will perform better than the double sided open space (C) due to reduction of solar gains being replaced by the effect of other internal gains. The chart also shows the changing trends between single (B) and double sided (C) open spaces, the latter being less effected by orientation due to its double orientation exposure. The combination of different strategies (Figure 5) indicates similar trends in cooling energy demands between the three layouts, in which differences observed between the three base cases dissolved in different scenarios when solar gains were being effectively modulated by applying external shading. Good practice optimization Aiming at higher performance and comfort levels, the following studies evaluated the potential of more advanced strategies to further reduce the resultant temperature and cooling loads accordingly; Glazing properties. The thermal balance of glazing, being a dominant component, was studied; for each base case, five envelope properties were considered, each offering a different balance between heat gains vs. losses as well as different daylight intensity (Figure 6). Thermal mass and night ventilation. The possibility of applying high thermal capacity materials within the common office space layout was narrowed down to the 3 scenarios; (a) Exposed concrete floor, (b) a + concrete partitions, (c) b + exposed ceiling. Thermal simulations for the three scenarios revealed considerably lower days within comfort for scenario (c) during cold periods, indicating that heating might have to be introduced, and that the cold outcome might work better in cases of high internal gains due to occupancy patterns or equipment usage. Natural ventilation. These studies evaluated the balance between space cooling and physiological cooling considerations; after determining the required air flow rates needed to optimize performance, CFD simulations had been used in order to evaluate resultant temperatures and air flow rates throughout the office space for a typical mid-season week. Natural ventilation studies proved that in periods when external temperature reaches above certain limits, the space cooling effect achieved by natural ventilation was often very limited; however, under the same conditions, physiological cooling effect by air movement throughout the space could effectively lower the resultant temperature towards comfort. (6) (7) Cooling Heating Figure 6 Annual cooling energy demand of five different glazing properties scenarios for Cellular base case (in kwh\m2, Source: TAS). Figure 7 Cooling energy demand for different good practice optimization parameters (in kwh\m2, Source: TAS). Good practice optimization. The study showed how further efficiency improvements could be achieved by applying advanced strategies (Figure 7); however, high internal gains will still generate an inevitable need for cooling (mostly during hot period), and by cutting off solar gains during cold period, 5

heating demand will increase. Nevertheless, during the process of their evaluation, strategies such as natural ventilation or thermal mass should also be measured against their added values for the quality of the space; i.e. by creating desirable air flow and stabilizing internal temperatures. Towards best practice Aiming towards the zero carbon office space, this part of the research, within the recognition of air conditioning as the main energy consumer, focused on the passive cooling solutions that might reduce or eliminate its use. After four selected passive cooling strategies had been evaluated (based on data from contemporary research, literature and precedents), this section highlighted radiant and ground cooling as the most effective passive cooling strategies for Israel s climate. However, considering the highly speculative Israeli market, the applicability of these strategies in Israel is expected to face strong market barriers, and most probably would be considered only for a use value building (Harrison et al. 2004), custom designed for specific end user organization. The limiting potential of the Israeli air to effectively absorb excess heat indicates the need for hybrid or mixed mode systems in which low energy mechanical systems are coupled with natural forces; e.g. hybrid evaporation systems could be very efficient, as well as heat recovery mechanisms which could be coupled with the ground cooling system. These should be integrated aside renewable systems (which were not addressed in this research), mostly solar systems, in the light of Israel s high solar radiation availability. THE OPEN AIR OFFICE CONCEPT The inspiration for an open approach for office buildings in Israel was drawn from the local building tradition; one in which the potential of outdoor and semi-outdoor activities to take place throughout a considerable time of the year had been widely recognized, mostly throughout the pre- AC era. The Open Air concept aimed at reintroducing that potential to the contemporary office building typology (Figure 8). The need for diversity and informal reflection and meeting areas as part of the new office space, generated an excellent opportunity to reinvent these spaces in the Israeli office building typology through transitional or outdoor spaces. A dynamic semi-outdoor space, which could be opened or closed according to the user demand and the outdoor conditions, could serve as an extension to the internal office space and activity. Analysis methodology (8) For the thermal and daylight analysis, a double sided section had been chosen with similar proportions as the previous 15m base case used throughout this research. The layout of 15m X 12m which included the fully optimized configuration (as previously studied) was coupled with a 3m transitional space projected towards to South, with openable full height glass partitions between them calculated to be opened when the adjacent semi outdoor space temperature was within the boundaries of comfort (Figure 9). Figure 8 the Open Air Concept evolution 6

Thermal simulations for the internal office space in a free running mode (Figure 10), revealed resultant temperature fluctuating very closely to the external ones and relatively high levels of comfort hours yearly; strong potential was evident for opening the office space to the outdoors in sunny days during cold-periods, as well as through most of the mid-period. Daylight simulations for the same boundary conditions showed the potential of the adjacent space to serve as an effective buffer from direct sunlight without compromising the required daylight levels in the office space. (10) (9) Internal space Semi outdoor space Figure 9 Case study model for the Open Air Concept analysis. Figure 10 Annual resultant temperature simulation (Source: TAS). External temperature (oc) Internal office space resultant temperature (oc) ASHREA 55 comfort band Thermal vs. visual comfort By applying adaptive opportunities and space diversity, the occupants interact both with building elements and with the building space. In addition to the basic environmental strategies applied (orientation, exposure, ventilation etc.), the application of the adjacent semi-outdoor space towards the South is taking performance further - by serving as a mediator between internal and external conditions, and by offering a good balance between thermal and visual issues. Figure 11 shows how the deep projection addresses glare and excess heat issues effectively while the adjustable louver-shelf serves as solar protection for the semi-outdoor space and redistributes light towards the depth of the office space. (12) (11) Figure 11 Adaptable envelope design. Figure 12 Exterior view of the open air case study showing the design expression of the environmental concepts. 7

Activities The diversity of space which is required to address new patterns of office activities have been addressed and distributed according to visual and thermal considerations; e.g. presentation areas in less exposed spaces, informal areas in semi outdoor spaces with higher tolerance levels to the outdoor climatic conditions and fixed workstations, with higher control levels and stabilized thermal conditions. Design expression The external figure of the building (Figure 12), reflects the shift of mind from the sealed glass building, disconnected from its environment, to a new model in which different levels of exposure drive the building s external image. The correlation between the external layout and the performance becomes complete and corresponds with the local architectural design language from earlier times in Israel s history, in which climatic considerations helped contextualize the modern trends to the local climate. CONCLUSION This research showed that by adopting an environmentally responsive approach, the troubling performance of the Israeli common practice office could be dramatically enhanced - even up to a zero energy balance. As overheating was identified as the main issue, optimization phases mostly focused on blocking solar heat gains while dissipating internal ones; while preliminary optimization studies showed how effective simple design decisions could be, In further optimization levels, when direct solar gains were effectively blocked, internal heat gains became predominant, and issues such as control, adaptability and thermal vs. visual comfort balance became critical to comfort and performance. Aside the more technical aspects which evaluate comfort and performance through numerical prediction, the architectural performance of the space must also be accounted for and correspond to the office concepts of tomorrow. In the new work environment where borders dissolve (e.g. home and work or virtual and real ), the same levels of flexibility and adaptability will have to be applied to the spatial differentiation between in and out ; The ability of the coastal Mediterranean climate to dissolve these boundaries within comfortable outdoor climatic conditions, offers the unique opportunity to open up the sealed office glass box to the outdoors. The open air office approach had been incorporated into this concept, in which new office organizational trends and spatial design values reintroduce the potential for working with the Israeli outdoor climate. ACKNOWLEDGEMENTS I would like to thank Professor Simos Yannas for his personal guidance and feedback throughout the process of my work on this research. I would also like to thank the Architectural Association for the bursary that supported this research. REFERENCES ANSI/ASHRAE/IESNA Standard 90.1. 2007. Normative Appendix B Building Envelope Climate Criteria. International climatic zone definition Autodesk Ecotect Analysis. 2011. Autodesk. Dixon, M. and Ross, P. 2011. VWork: Measuring the benefits of agility at work. Unwired Ventures Ltd. UK. Duffy F. The New Workspace. 1997. Conran Octopus. EDSL Tas (v.9.2.1.1). 2011. EDSL Ambiens (v.9.2.1.1). 2011. Harrison, Wheeler and Whitehead. 2004. The distributed Workplaces. Spoon Press. Johnson, Counsell and Strachan. 2011. Trends in Office Internal gains and the Impact on space Heating and Cooling. CIBSE Technical Symposium, Leicester, UK. McKinsey and Company, Greenhouse gas abatement potential in Israel, Israel s greenhouse gas abatement cost curve, November 2009. Radiance 2000, Berkeley Lab. US Department of Energy National Renewable Energy Laboratory (NREL). http://www.nrel.gov 8