CARES Technical Approval Report TA1-B 5064

Similar documents
Properties of Reinforcing Steels

TERWA REBAR CONNECTION COUPLERS. CARES Technical Approval 5058 TA1B

HIGH PERFORMANCE REINFORCEMENT PRODUCTS. Product Catalogue.

TERWA REBAR CONNECTION COUPLERS

National technical approval Coupler

ISO Steels for the reinforcement of concrete Reinforcement couplers for mechanical splices of bars Requirements

How to calculate anchorage and lap lengths to Eurocode 2

COLUMN SHOES HPKM, PPKM, PEC

fischer Test Report Fixing Tests for Bison Hollow Core Slabs

KENYA STANDARD KS 574:2017. Steel fabric for reinforcement of concrete Specification

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: DEXTRA MANUFACTURING CO., LTD.

R-Group Finland Oy. REA Lifting Inserts Technical Manual According to Eurocodes, EU Machinery directive 2006/42/EC and VDI/BV-BS 6205 CE Approved

Originally Issued: 02/02/2009 Revised: 11/09/2017 Valid Through:02/28/2019

SINTEF Building and Infrastructure confirms that. HRC 700 cast-in connection system

Shackles. Applications. Range. Design. CAD drawings. Finish

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: SAS STRESSTEEL INC. 100 NEW DUTCH LANE FAIRFIELD, NEW JERSEY 07004

-165 C / -265 F CRYOGENIC REBAR SPLICING SYSTEMS

PRECAST CONCRETE CONNECTIONS - US PRACTICE

R-Group Finland Oy. RTA, RWTL and RWTS Lifting anchors Design instructions

SECTION REINFORCING STEEL

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP DRY FIX BONDING STRIP (GDFBS 70 AND GDFBS 110)

Originally Issued: 11/24/2010 Revised: 01/20/2017 Valid Through: 11/30/ Design

European Technical Assessment ETA-16/0865 of 08/11/2016

HILTI HY 150 REBAR DESIGN GUIDE

Lifting Sockets. Flat Lifting Sockets

1. Cast-in-place concrete is specified in Section

European Technical Assessment ETA-10/0422 of 08/01/2016

MAX FRANK EGCOBOX CANTILEVER CONNECTION SYSTEM EGCOBOX CANTILEVER CONNECTION SYSTEM

1 Exam Prep Placing Reinforcing Bars Tabs and Highlights

EVALUATION REPORT. PFC-5551 Reissued April 1, Filing Category: DESIGN Steel (038)

Lintel Tables Design Notes and Limitations

Structural Design of Pergola with Airfoil Louvers

European Technical Assessment. ETA 15/0226 of General Part TCM400PE, TCM600PE. Trade name of the construction product

Agrément Certificate 17/5450 website: Product Sheet 1 FOSROC HYDRO-EXPANSIVE WATERSTOPS SUPERCAST SW

Class III Pipes Fittings (Dy 500 mm)

EN REINFORCED MASONRY DESIGN EXAMPLE 1 (NOTE: THIS USES THE UK NATIONAL ANNEX NDP VALUES)

METHOD STATEMENT for INSTALLATION OF MICROPILE

Couplers For Reinforcement Bars

Tips For Designing Constructable Concrete Buildings

GROUND RELEASE SHACKLE

RADBAR DAMP-PROOF COURSES RADBAR HIGH PERFORMANCE DAMP-PROOF COURSE

WAVIN ROAD GULLIES. Date of First issue: 16 April 2014 Brian Chamberlain Claire Curtis-Thomas

KOMPOZITOR CHIMNEY SYSTEMS FURANFLEX-RWV CHIMNEY LINING SYSTEM

European Technical Assessment ETA-14/0453 of 11/12/2014

Building Regulations

Smarter. Safer. Leaner.

XYPEX WATERTIGHT CONCRETE SYSTEM XYPEX ADMIX C-1000 NF

CURRICULUM FOR STEEL FIXER

USE OF 500 GRADE STEEL IN THE DESIGN OF REINFORCED CONCRETE SLAB. Prof. M. Shafiul Bari, Ph.D Department of Civil Engg., BUET

Safety Barrier Solutions

Subcommittee 3, Connections August 15, 2012

ISO INTERNATIONAL STANDARD

Structural Eurocodes an overview

PRODUCT SHEET 1 KRYSTOL INTERNAL MEMBRANE HS (KIM-HS)

USE OF 500 GRADE STEEL IN THE DESIGN OF REINFORCED CONCRETE SLAB. Prof. M. Shafiul Bari, Ph.D Department of Civil Engg., BUET

Z5033 E3 Ball joint adapter Mounting instructions

DURABILITY AND SERVICEABILITY

Schöck Isokorb type CV

INNOVATIVE SLOPE STABILISATION BY USING ISCHEBECK TITAN SOIL NAILS

Post installed rebar connections

TWO-WAY POST-TENSIONED SLABS WITH BONDED TENDONS

SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 5 REINFORCING STEEL. 5.1 General Certification Fabrication...

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: BARSPLICE PRODUCTS INC WEBSTER STREET DAYTON, OHIO

3. Bond, Anchorage and Shear This chapter will discuss the following topics:

DESIGN OF POST-TENSIONED MEMBERS IN BENDING USING ACI SIMPLIFIED PROCEDURE

Protective Capony RTC-16

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

Reinforcement. Fabrication and Site Handling of Reinforcing Bars. PRACTICE NOTE No.

Reinforced concrete beam-column joints with lap splices under cyclic loading

In-plane testing of precast concrete wall panels with grouted sleeve

JULY 2014 LRFD BRIDGE DESIGN 5-1

ROK HCS slab support Design instructions

Perfect Manhole Installation Manual May 2012 Rev 8 Perfect Manhole System Precast concrete manholes with load bearing elastomeric joints

Adhesive Anchors SECTION CONTENTS. General Information. Installation Information Design Information Material Information Ordering Information

Specification texts FRIAFIT sewage system

Lightning Protection System for PC Buildings

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

Mapefix PE Wall. Chemical anchor for masonry and light loads

W-09 ANCHOR CHAIN CABLES AND ACCESSORIES FOR SHIPS

Bond between self-compacting concrete and reinforcement

AS/NZS 1477:2017. Australian/New Zealand Standard. PVC pipes and fittings for pressure applications. Superseding AS/NZS 1477:2006 AS/NZS 1477:2017

1. Structural Steel Sections Structural steel sections can be classified into various groups according to their shapes.

fischer Test Report Fixing Tests for

SERIES 1100 KERBS, FOOTWAYS AND PAVED AREAS

SEPTEMBER construction type cavity barriers. SP Firestop Systems. The purpose-made solution for cavity fire stopping

Section 906. STRUCTURAL STEEL

Frequently Asked Questions (FAQ) about Epoxy-Coated Reinforcing Bars

TRUSTSEAL HIGH-FRICTION SURFACING SYSTEM KEYGRIP EPOXY 924

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 17.

specification sheet for approval

European Technical Assessment. ETA-12/0398 of 29/12/2017. General Part. Instytut Techniki Budowlanej. Technical Assessment Body issuing the

SCAFFOLDING RUNWAY SYSTEM

CHEMICAL /4" 3/8" to 5/8" /8" 3/4" to 1-1/4" 1 10

Z5043 MAX Horizontal bracket Mounting instructions

PUDLO CWP (CEMENT WATERPROOFING POWDER)

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

Easy to Use A7 Saves You Time and Money

Method of Measurement for Road Works Series MM Structural Concrete

XTRATHERM THIN-R INSULATION XTRATHERM THIN-R FLAT ROOF INSULATION BOARD (FR ALU)

Transcription:

CARES Technical Approval Report TA1-B 5064 Issue 1 BARUS SimGrip Standard and Positional Parallel Threaded Couplers Assessment of the BARUS SimGrip Standard and Positional Parallel Thread Coupler Product and Quality System for Production 5064

Product BARUS SimGrip Standard and Positional parallel threaded mechanical couplers for reinforcing steel 1 Product Summary BARUS SimGrip Standard and Positional parallel threaded couplers are for the mechanical connection of deformed high yield carbon steel bars for the reinforcement of concrete complying with the requirements of BS4449 Grade B500B. Product approval held by BARUS Muhendislik Metal Ins. Taah. San. Ve Dis Tic. Ltd. Sti. Sekerpınar Mah. Basak Sok. 14-B Cayirova 41420 Kocaeli / Turkey Tel: +90 (262) 658 19 41 Fax: +90 (262) 658 19 42 Email: info@bar-us.com 1.1 Scope of Application BARUS SimGrip Standard and Positional parallel threaded mechanical couplers, in the size range 16mm - 40mm, have been evaluated for use as follows: a) Static tension applications in reinforced concrete structures designed for EC2 and BS8110: Part 1: in accordance with CARES Appendix TA1-B. 1.2 Design Considerations BS 8110 Clause 3.12.8.9 Laps and Joints states Connections transferring stress may be lapped, welded or joined with mechanical devices. They should be placed, if possible, away from points of high stress and should preferably be staggered. However, BS 8110 Clause 3.12.8.16.2 Bars in tension states The only acceptable form of full-strength butt joint for a bar in tension comprises a mechanical coupler satisfying specified slip and tensile strength criteria. 1

CARES Technical Approval Report TA1-B 5064 Eurocode 2, Clause 8.7 Laps and mechanical couplers 8.7.1 General (1)P Forces are transmitted from one bar to another by: lapping of bars, with or without bends or hooks; welding; mechanical devices assuring load transfer in tension-compression or in compression only. Clause 8.8 Additional rules for large diameter bars goes on to state that Splitting forces are higher and dowel action is greater with the use of large diameter bars. Such bars should be anchored with mechanical devices. The specified cover for fire resistance and durability should be provided to the coupler sleeve. All couplers have been designed with controlled mechanical properties to be compatible with reinforcing bars complying with reinforcement of the relevant Grade in accordance with BS4449. 1.3 Conclusion It is the opinion of CARES that BARUS SimGrip Standard and Positional parallel threaded couplers are satisfactory for use within the limits stated in paragraph 1.1 when applied and used in accordance with the manufacturer s instructions and the requirements of this certificate. L. Brankley Chief Executive Officer June 2017 5064 2

2 Technical Specification 2.1 General BARUS SimGrip Standard and Positional parallel threaded mechanical couplers are for joining deformed grade B500B steel reinforcing bars complying with BS4449 thereby create structural continuity of the reinforcing system. BARUS SimGrip Standard and Positional couplers provides a full strength connection. Each end of the bar to be joined is cut square, enlarged using a cold forging process and a standard metric threaded onto the enlarged bar end. The thread form is such that the cross sectional area of the bar ends is not reduced, thus ensuring the strength of the connection matches or exceeds that of the parent bars. 2.2 SimGrip-St (Standard) Coupler The SimGrip-St (Standard) is comprised of an internally threaded coupler and is used in applications where the continuation bar can be rotated freely. The ends of the bars are cold upset and threaded for half the length of the coupler. SimGrip-St (Standard) Coupler L (mm) Bar Size Product Code L D Metric Thread Colour Code TA1B B500B (mm) (mm) (mm) (mm) tension only Table 1 16 BSGC16 40 28 M20x2.5 Pink 20 BSGC20 48 32 M24x3.0 Green 25 BSGC25 60 40 M30x3.5 Blue 32 BSGC32 72 50 M36x4.0 Yellow 40 BSGC40 90 62 M45x4.5 Red ØD (mm) 3

CARES Technical Approval Report TA1-B-5012 5064 2.3 SimGrip-Ps (Positional) Coupler The SimGrip-Ps coupler is designed for use when both bars would be impossible or difficult to rotate because of their size, length or location, the SimGrip splice system simply extends the thread onto the ribs of the bar, thereby enabling the coupler to be fully screwed onto it. It is then unscrewed from one bar and back onto the second bar to accomplish the connection. The SimGrip-Ps positional coupler type is the same as for standard type, however, one bar is threaded for a full coupler length. SimGrip-Ps (Positional) Coupler Bar Size Product Code L D Metric Thread Colour Code TA1B B500B (mm) (mm) (mm) (mm) tension only Table 2 L (mm) 16 BSGC16 40 28 M20x2.5 Pink 20 BSGC20 48 32 M24x3.0 Green 25 BSGC25 60 40 M30x3.5 Blue 32 BSGC32 72 50 M36x4.0 Yellow 40 BSGC40 90 62 M45x4.5 Red 3 Product Performance and Characteristics Full tests have been carried out to demonstrate compliance with performance requirements defined in CARES Appendix TA1-B including the performance requirements of EC2 and BS8110 when used with reinforcing bars to BS4449 Grade B500B. ØD (mm) CARES APPENDIX TA1-B strength requirements Permanent deformation is less than 0.10mm at 325 MPa for B500B in tension 5064 4

4 Installation 4.1 Process The bars to be spliced are cut square and cold-upset using the BARUS rebar forging machine, and then threaded. For proper installation, SimGrip Method Statement must be followed. The parts are screwed together and tightened using a suitable wrench. The machines must be operated by suitably trained and certified staff in accordance with BARUS operating instructions. The semi-automatic, PLC controlled equipment specifically designed and manufactured by BARUS for use in the coupler industry to ensure and enhance product performance. See figure 1 and 2. Figure 1 - BARUS Cold Forging Press Figure 2 - BARUS Threading Machine Cold upsetting Threaded bar Figure 3 5

CARES Technical Approval Report TA1-B-5012 5064 4.2 BARUS SimGrip Standard parallel threaded coupler installation 1 Screw the coupler onto the fixed bar until it hits the end of the threading and lock tight. The bar end should be centered within the coupler. 2 3 4 Remove the plastic caps from the coupler and rebar. Attach the continuation bar into the coupler and rotate as far as the continuation bar will turn. Tighten the joint using a wrench on the continuation bar. 6

4.3 BARUS SimGrip Positional parallel threaded coupler installation 1 Remove the BARUS concrete spacer plug and rebar thread protector. 2 3 Screw the coupler from the continuation bar and rotate until it hits the end of the threading on the opposing bar and lock tight. Tighten the joint using a wrench on the continuation bar. 7

CARES Technical Approval Report TA1-B-5012 5064 5 Safety Considerations Couplers are supplied in wooden containers as per BARUS packing procedures and must be followed and handled with appropriate lifting equipment. It is advisable to use safety equipment such as gloves, hard hat and eye protection during rebar cutting, forging and installation. 6 Product Testing and Evaluation BARUS SimGrip Standard and Positional parallel threaded couplers have been tested to satisfy the requirements of EC2 and BS8110 when used with reinforcing bars to BS4449 Grade B500B. The testing comprised the following elements: EC2 and BS8110 Tensile Strength Permanent Deformation The products are subject to a programme of periodic testing to ensure that they remain within the performance limits of this technical approval. 7 Quality Assurance BARUS SimGrip Standard and Positional couplers are produced under an ISO9001 quality management system certified by CARES. The quality assurance scheme monitors the production of the couplers and ensures that materials and geometry remain within the limits of this technical approval. 5064 8

8 Building Regulations 8.1 The Building Regulations (England and Wales) Structure, Approved Document A BARUS SimGrip Standard and Positional parallel threaded couplers, when used in EC2 based designs using the data contained within this technical approval, satisfy the relevant requirements of The Building Regulations (England and Wales), Approved Document A. Materials and Workmanship, Approved Document This technical approval gives assurance that the BARUS SimGrip Standard and Positional parallel threaded couplers comply with the material requirements of EC2. 8.2 The Building Regulations (Northern Ireland) Materials and Workmanship This technical approval gives assurance that BARUS SimGrip Standard and Positional parallel threaded couplers comply with the material requirements of EC2 by virtue of regulation 23, Deemed to satisfy provisions regarding the fitness of materials and workmanship. 8.3 The Building Standards (Scotland) Fitness of Materials This technical approval gives assurance that BARUS SimGrip Standard and Positional parallel threaded couplers comply with the material requirements of EC2 by virtue of Clause 0.8. Structure BARUS SimGrip Standard and Positional parallel threaded couplers, when used in EC2 based designs using the data contained within this technical approval, satisfy the requirements of The Building Standards (Scotland) Clause 1. 9

CARES Technical Approval Report TA1-B-5012 5064 9 References BS 4449:2005 Specification for carbon steel bars for the reinforcement of concrete. BS8110: Part 1: 1997 (Amended 2007) Structural Use of Concrete, Code of Practice for Design and Construction. BS EN 1992-1-1:2004 Eurocode 2 Design of concrete structures - General rules for buildings. BS EN ISO 9001: 2008 Quality systems. Model for quality assurance in production, installation and servicing. CARES Appendix TA1-B; Quality and Operations Schedule for the Technical Approval of Couplers for Reinforcing Steel For BS8110 and ENI 992-1-1 Applications for Static Loading in Tension or Tension and Compression. 5064 10

10 Conditions 1. The quality of the materials and method of manufacture have been examined by CARES and found to be satisfactory. This technical approval will remain valid providing that: a. The product design and specification are unchanged. b. The materials, method of manufacture and location are unchanged. c. The manufacturer complies with CARES regulations for technical approvals. d. The manufacturer holds a valid CARES Certificate of Product Assessment. e. The product is installed and used as described in this report. 2. CARES make no representation as to the presence or absence of patent rights subsisting in the product and/or the legal right of BARUS to market the product. 3. Any references to standards, codes or legislation are those which are in force at the date of this certificate. 4. Any recommendations relating to the safe use of this product are the minimum standards required when the product is used. These requirements do not purport to satisfy the requirements of the Health and Safety at Work act 1974 or any other relevant safety legislation. 5. CARES does not accept any responsibility for any loss or injury arising as a direct or indirect result of the use of this product. 6. This Technical Approval Report should be read in conjunction with CARES Certificate of Product Assessment No 5064. Confirmation that this technical approval is current can be obtained from UK CARES. 11

CARES Technical Approval Report TA1-B 5064 BARUS SimGrip Standard and Positional Coupler Applications SimGrip Standard and Positional parallel threaded couplers in high-rise projects; foundations, columns, slabs curtain walls. SimGrip Standard and Positional parallel threaded couplers in Cages, Pre-Cages, Piles and Diaphragm Walls. SimGrip Standard and Positional parallel threaded couplers in columns. 12

UK CARES Pembroke House 21 Pembroke Road Sevenoaks Kent TN13 1XR Phone: +44(0)1732 450000 Fax: +44(0)1732 455917 E-mail: general@ukcares.com URL: www.ukcares.com TECHNICAL APPROVAL 002 Independent Product Assessments for the Construction Industry Copyright UK CARES 9.6.17