A TECHNICAL GUIDE SOLVENT EMISSIONS CONTROL: Operation. How Solvent Vapors Escape. Whose Problem Is It? Our Commitment.

Similar documents
COLD SOLVENT CLEANING AND STRIPPING OPERATIONS (Adopted & Effective 5/23/07) (2) Any cleaning of application equipment is not subject to this rule.

Safe use of solvent degreasing plant

Solvent Recovery Systems

Flux Collection and Self-Clean Technique in Reflow Applications

Switch-Tek. LV41 & LV42 Series Manual. Sump Float Level Switches

B. System Design and Performance Requirements

Risk Assessment and Preventive Measures Checklist for Construction and Renovation. Location of Construction: Project Start Date: Estimated Duration:

Reclaimed Water Treatment, Distribution, Pumping and Storage Engineering Report Form

SAFETY POLICY AND PROCEDURE MANUAL All Euramax Subsidiaries. Number E-2.0 Safety Audits and Inspection Program

Indoor Air Quality Plan

KEYWORDS: Deaerator, Condensate, Oxygen Removal, Boiler Feed Water, Heater, Water Treatment

PP/TPO Processing Guidelines and Troubleshooting Guide

VpCI PROTECTION SYSTEM FOR ELECTRICAL/ ELECTRONIC ENCLOSURES

Sahara Pro Advanced colorant performance

Meet the new T-80 Series

QUICKTEMP TECHNOLOGY IMPROVED EFFICIENCY ACROSS THE ENTIRE T-80 RANGE OF UNITS

Standard Operating Procedures for Servicing Laboratory Exhaust Systems

Chlorinated Organics Closed Loop Unloading of Solvent Tank Trailers

Suggested Practices for Fluoride Design

DOUBLE SLIDE RAIL INSTALLATION METHOD. Double Slide Rail August

STERIS Continuous Effluent Decontamination (CED) System

Pesticide Chemical Safety

CHILLED WATER DISTRIBUTION SYSTEM

Preliminary Hazard Analysis and Risk Assessment for the Wood Centre Development, Southwood Resources - Huon

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

Controlling NOx and other Engine Emissions

HAZOP and What-If Analyses

T-Series. An all-new line of self-powered truck units destined to become the new industry benchmark.

Jack Werner, Ph.D, Lic#255 Phone: 405/

SOLVENT CONSUMPTION IN DRY-CLEANING

ISO Monitoring and Measurement Nonconformance and Corrective and Preventative Action

International SEMATECH Technology Transfer # A-TR

LOUISIANA URBAN STORMWATER COALITION. EXECUTING A SWPPP DURING CONSTRUCTION Presented by: Diane T. Baum

Pesticide Safety Program

Honeywell Refrigerants Improving the Uptake of Heat Recovery Technologies 1

Environmental Conditions Laboratories (for commercial use) Group

Milk Pre-Cooler Plumbing Considerations. ATCP 65, Wisconsin Administrative Code and the 2015 PMO

Before You Start Renovating Your Bathroom

Property Condition Assessment

PureCycle 200 Heat-to-Electricity Power System

UFL Micro Biogas CHPs

Absorption in cartridge systems for ultimate disposal, or even off-site recovery may be an alternative to use for small businesses..

BIOMEDICAL WASTE FACILITY INSPECTION REPORT* Facility name: Permit #: Date of Inspection:

DUQUESNE UNIVERSITY ASBESTOS OPERATIONS & MAINTENANCE PROGRAM

Flooded Type Water-Cooled Chillers. R134a

SUMMER 15 EXAMINATION

CHECKLIST PESTICIDE STORAGE, HANDLING AND DISPOSAL

Plant Layout and Material Handling

IN-TANK TECHNOLOGY INSTRUCTIONS FOR USING FLO KING IN-TANK CARBON BAG

CHECKLIST Inspecting a Garage

Indoor Building Survey and Product Inventory

CCSD & CCSE Series Oil/Water Separators

Virginia Department of Health Office of Drinking Water

Comparing Evaporative Technologies for the Recycling of Produced Waters

TransPacific Energy Advantage: Case Studies

ISPE CASA Energy Management Forum - Energy Management of Capital Projects at Novartis

TRENCH SAFETY TRAINING

Background. AEM Tier 2 Worksheet Greenhouse Maintenance

Ethylene Oxide Sterilant Alternatives

Environmental Requirement Review Checklist and Certification

How are Industry Standards, Engineering Codes, Best Management Practices and Other Measures of Compliance Being Met by Facilities?

Bryant University s Energy Guidelines for Sustainability

The 5S Philosophy. A better Work Environment for Everyone

Living With a Septic System A homeowner s guide to basic septic system operation and maintenance

MATERIAL SAFETY DATA SHEET

POLLUTION PREVENTION MEASURES FOR THE AEROSPACE INDUSTRY

Nilan VPL Active heat recovery and cooling (air/air)

COMPOSITION / INFORMATION ON INGREDIENTS

RADON WELLISUMP BASIN FOR NEW HOME CONSTRUCTION

Energy Savers: Air-Source Heat Pumps

This policy will generally explain the following in regards to the City sewerage collection systems:

TEMPERATURE AND HEAT DISTRIBUTION PROTOCOL FOR PROCESSING IN DISCONTINUOUS AGITATING RETORTS

SONO JELL # 9 PETROLATUM

Training Certification Categories

Basic Septic And Plumbing Maintenance. By: All-Clear Septic & Wastewater Services

GAF Scheduled Maintenance Checklist

HELICAL OIL SEPARATORS

Standard Test Method for Effects of Heat and Air on Asphaltic Materials (Thin-Film Oven Test) 1

COLD NEUTRON SOURCE AT CMRR

General Foam Information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210)

Design & Construction Standards, Revised January

QUALITY ASSURANCE MANUAL FOR APPLICATORS OF ELASTOMERIC SHEET LININGS

Energy efficiency of cooling systems: Optimization through precise energy monitoring

Texas Pollutant Discharge Elimination System Industrial Storm Water Permit TXR Storm Water Pollution Prevention Plan Worksheet Instructions

Water Level Meter User Manual

Fiberglass Cooling Towers

Aqua-Swirl Stormwater Treatment System

U. S. Army Corps of Engineers Soil Vapor Extraction Subsurface Performance Checklist

State of Ohio Environmental Protection Agency

Green Building Guideline of Jordan

Chem 355 Jasperse DISTILLATION

Fiji Thermal and Plasma Atomic Layer Deposition System (ALD) By Ultratech (Cambridge)

Measuring Bulk Solids on a Conveyor

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)

Partnership. Medical Waste Autoclaves. Medical Waste Autoclaves

Green Building Guideline of Jordan

NEW PROJECT ENVIRONMENTAL CHECKLIST

Transcription:

SOLVENT EMISSIONS CONTROL: A TECHNICAL GUIDE Branson Ultrasonics Corporation recognizes the need for environmental responsibility in manufacturing today. As an international corporation whose cleaning equipment is used widely in industry, Branson holds an obligation to address environmental concerns. Branson is committed to fulfilling this obligation by designing solvent and aqueous cleaning equipment with environmental safeties as integral elements, by sharing our research into emissions control with industry, and by participating actively with government and corporate groups to find ways to protect earth s environment. Branson therefore calls for responsibility in chemical handling and conservation and offers methodology for substantially decreasing emissions in the cleaning process. Our Commitment As a manufacturer of aqueous as well as solvent equipment, Branson is bias-free in its recommendations. Our commitment becomes action as we at Branson: Work with environmental & legislative groups. Test solvent alternatives in our Cleaning Applications Laboratory. Incorporate emission control design into product concepts. Promulgate solvent emission control information & techniques. Solvent Emissions Scientific evidence indicates the global ozone layer is being depleted or thinned by chlorofluorocarbons (CFCs) released into the atmosphere. Holes in the layer allow the penetration in large doses of ultraviolet radiation which can be harmful to human health and environmental balance. Many nations already have signed a pact to reduce CFC production levels immediately, with the ultimate goal of total CFC phaseout by the turn of the century. Legislation undoubtedly will be forthcoming. Industry is responding by searching for alternatives to CFC-based chemicals. Whose Problem Is It? Solvents used for cleaning processes represent about 20 percent of the CFCs produced annually. Refrigerators, found in every home, and air conditioners in homes, cars, and places of business are by far the greatest users. But the problem belongs to all of us. Regulation will affect a// users. A calm and forward-thinking approach toward environmental protection is needed. Although solvent alternatives are being developed and some with less CFCs already are available, the issue of environmental responsibility will remain. Never again can we consider any chemical completely safe for the environment or human health. Therefore we must institute good work practices now to decrease emissions of any chemical as much as possible. How Solvent Vapors Escape Solvent loss in the cleaning process can be attributed to three areas: Operation Equipment Design Maintenance Operation Our research has shown that improper operation of the cleaning process is the primary source of solvent emissions from open-top degreasers. Operation is the leading cause because human physiology makes exact process control nearly impossible. For example, lowering part fixtures into a degreaser faster than 10 feet per minute will forcefully displace solvent vapors above the cooling coil and out of the tank. Yet data collected by industry shows that the typical operator lowers the parts between 30 and 100 feet per minute. Even the most conscientious operator will tend to violate this parameter and contribute to unnecessary emissions. With part loads ranging from a few pounds to tens of pounds, precise and slow speeds are very difficult to perform. Even if a mechanical hoist is used, proper vertical speeds often are exceeded in the interest of increased production. Branson believes it is imperative that action be taken to reduce solvent emissions while alternatives are sought. We have researched the subject and have found that automation of a cleaning process is the optimal way to substantially reduce solvent emissions. Our test measurements of emissions show that a vertical speed of 20 feet per minute in the cleaning process can consume from 30 to 50 percent more solvent than a vertical speed of 10 feet per minute. Branson recommends a controlled vertical speed of no more than 10

feet a minute when parts enter or exit a solvent cleaner. Correct residence time within the vapor zone is another aspect of solvent cleaning that often falls short. Proper procedure calls for holding the parts in the vapor zone for a final vapor dry until condensation on the part ceases. Condensation will cease when the temperature of the part is in equilibrium with the temperature of the vapors. It is critical that the time required for this step be carefully observed since it is difficult for the human eye to determine where condensation ceases. If the part is pulled out too soon, liquid solvent will vaporize and escape from the equipment. Depending on the mass and complexity of the part, the vapor dry time could range from 30 seconds to several minutes. If this is done manually, extended vapor dry times can be physically demanding and, therefore, often shortened. Correct freeboard residence time also is important. As the parts are removed from the vapor zone to the freeboard area, the remaining solvent condensation will vaporize and, being heavier than air, will fall back into the vapor zone. If the parts are held in the area of the cooling coils in the freeboard area while still above the vapor zone, more vapors are returned. But, as with the vapor zone, it is physically demanding to suspend the parts in the freeboard area manually. Operation - Solution Branson recommends automating for precise control of the correct process speeds and residence times. Our research shows that solvent emissions can be decreased 70% by automating the process. In a test conducted to measure the effect of certain working conditions on solvent emissions, our base data was generated with a covered, idling, Branson BSD Model 1216 solvent cleaner. The base measurement was assigned a value of one. A representational workpiece load was processed under optimal conditions, that is following all of the recommended procedures to minimize solvent emissions. Processing was controlled through use of a Branson TDR automated transport system. Production parameters were a slow vertical transport speed, 30-second vapor zone time above the boiling sump, 30 seconds of ultrasonic immersion, 60 seconds in the vapor zone for drying and 30 seconds in the freeboard zone. Good processing achieved a value of two. Industry norm, however, of the actual solvent cleaning process generates an emission value of eight. Typical operations include practices such as fast vertical speed of the parts into the equipment, reduced residence times, liquid drag-out, and uncontrolled spraying. SOLVENT EMISSIONS EMISSION FACTOR 8 7 6 5 4 3 2 1 0 TYPICAL GOOD BAS E Solvent emissions can he reduced from eight to two on the value scale by automating for precise process control, Summary: Regardless of how efficient the design of a cleaning system, improperly operated equipment is the biggest source of emission. Through proper operator training and awareness programs, the industry norm of "eight" can be reduced. But to get dramatic results of a reduction from "eight" to "two", a programmable transport is necessary to control residence times and proper processing speeds. In addition, production benefits are realized - an automated system can increase throughput by running unattended and it minimizes health concerns for operator safety near solvents. Equipment Design Many features in properly designed cleaning equipment will work toward decreasing solvent emissions. Some aspects to look for are: Attached sliding cover. Actual measurements of operating equipment show that an idling covered machine will have 15-20 percent less emissions than a machine left uncovered. Attached sliding covers are best, not only for convenience, hut also because by moving horizontally, it does not create disturbance of the vaporiair interface and thereby reduces emissions. Vertical lift-off and hinged covers, when opened cause disturbances in the interface by creating turbulence within the machine and increasing solvent emissions. 100% freeboard. The greater the distance between the top of a stable vaporiair interface and the top of the unit, the greater the diffusion distance that solvent vapors must travel to escape the machine. Measurement has shown that the diffusion losses from a 75-80 percent freeboard unit are 15-20 percent higher than 100 percent freeboard.

BRANSON SOLVENT EMISSIONS AUDIT Just place this on a clipboard and take a few minutes to unobtrusively observe your solvent cleaning operation while you check these seven questions. 1. - - When the load is withdrawn, is any liquid solvent visible? 2. - - Does your operator withdraw the load without holding it in the freeboard zone? 3. - - Does your operator hold the product in the vapor zone for less than 30 seconds before withdrawing it from the unit? 4. - Does your operator spray above the vapor zone? 5. - Does your operator spray for more than 10 seconds? 6. - Does your operator withdraw the parts in a quick, jerking motion? 7. - Does your equipment have a lip vent exhaust or vapor recovery system? ANALYSIS ON BACK BRANSON ULTRASONICS CORPORATION

PROCESS ANALYSIS If you checked 'Yes' to any question on the front of this sheet, here are the estimated values for each item. This represents the percentage of extra solvent emissions as compared to a properly operated unit. Question 1. + 150% 2. + 60% 3. + 75% 4. + 50% 5. + 15% 6. + 30% 7. + 20% For example, if your solvent cleaning system has a lip vent exhaust or vapor recovery system, then tests show you have a 20% increase in solvent emissions. Since some practices contribute significantly more than others, the cumulative values for questions may not accurately reflect total emission savings possible, but they provide a screening tool to determine potential savings. Branson Ultrasonics can help you minimize solvent emissions for environmental and economic benefit. For practical information and processing guidelines that can be implemented in your plant, write for our Solvent Efficiency Package of literature. It includes Solvent Em issions Co ntrol: A Technical Guide. Write to us at Branson Ultrasonics Corporation, SEP Department, 41 Eagle Road, Danbury, Ct., 06813-1961, or call today at (203) 796-0330. BRANSON The Clean Idea People

Coolant flow meterltemperature sensor. Solvent emissions can occur through failure of the cooling coils, which would be caused by either insufficient coolant flow or inappropriate coolant temperature. A coolant flow meter and a temperature sensor should he designed into the equipment to shut down the heaters immediately if either condition should occur. Such safety devices prevent emissions. Low liquid level float. Once the liquid level in the boiling sump of a solvent cleaner falls low enough to expose the heating elements, the temperature of the elements could rise to the point where solvent decomposition could take place causing an acid condition. That contaminates the remaining solvent, which requires disposal as hazardous waste. A liquid level float would guarantee a minimum level of solvent above the heating elements. Some cautions lip vent exhausts actually create drafts over the top of the machine. This device draws air across the top of the solvent cleaner, which acts as a vacuum to draw additional solvent vapor out. As much as 20 percent more solvent will be consumed by a system with a lip vent exhaust. Carbon adsorption systems, fed hy the lip vent exhaust, collect solvent escaping the machine. Since the lip vent increases emission by 20 percent, the carbon adsorption system must be efficient enough to recover this additional solvent if it is to be advantageous. However, a major weakness of the lip ventcarbon adsorption systems is that they are effective only on the solvent they see. If liquid solvent is heing dragged out of the machine, then the lip vent exhaust and carbon adsorption would provide limited benefit. Sprays. Sprays are a commonly accepted part of the cleaning process, but they aggravate solvent emissions and should be avoided when possible. If sprays are required, they should be used under the vapor blanket with fixed spray manifolds angled downward. An uncontrolled hand-held spray will increase emissions significantly above the manifold spray. Equipment Maintenance Where solvent cleaning equipment is placed and how it is maintained are important factors in solvent emission control. leaks. All joints should he checked for tightness routinely to ensure no solvent is leaking. Because the solvent will vaporize, visual inspection often is not enough to detect leaks. Proper gasketing material should be used for the same reason. location. Avoid placing equipment near drafts, such as from fans or air conditioners, which cause disturbances in the vapor/air interface. Direct expansion refrigeration systems on cleaners can contribute to emissions through air movement from the fans used to cool the compressor. These drafts can be eliminated with a remotely-located chiller. Maintenance. Solvent loss can occur from spills when the degreasing system is cleaned during routine maintenance. Avoid this possibility by selecting equipment that includes features to simplify maintenance, such as clean-out doors that are easy to use, easily accessible sump drains, and pumpout kits. A Systems Approach An important step towards solvent emissions management is treating the solvent cleaning process as an integrated system rather than a piece of equipment operating independently. A well-designed emission efficient system is comprised of an environmentally-sound solvent cleaner and 501- vent recovery still, a remotely-located chiller, and an automated material handling system, with all pieces integrated to communicate with each other for safety and production efficiency. An automated transport system is the most effective means of achieving exact control of the process speeds and times. That control reduces solvent emissions dramatically. The proper process speed attainable only through automation prevents the piston effect of displacing solvent and eliminates drag-out losses from vapor/air interface disturbances when workloads enter or exit the solvent cleaner. Correct residence time within the vapor zone and the freeboard area is achieved with an automated transport system. An efficient system is easily programmed with exact parameters for repeatability in the cleaning process. A solvent recovery still concentrates contaminants from the workpiece cleaning in the still boil sump, This reduces the need of frequent solvent cleaner maintenance, which reduces the chances of spills or leaks. A still can be hard-plumbed to the solvent system and waste disposal drums through the use of pumps, so all solvent can be transferred mechanically, eliminating the need for manual handling, reducing spillage opportunity and worker exposure. By concentrating the contaminants in the still, the solvent cleaner works more effectively. A remotely located chiller avoids drafts created by direct expansion systems. With this system you can minimize solvent emissions while gaining predictable, consistent cleaning,

I Improper Operation Dragout Drafts I Piston Effect Accidental I Emission Liquid Waste Leaks Primary cause - Proper operation is inconsistent with human physiology. Carefully calibrated entrance & exit speeds of parts cannot be achieved by hand. Solution - Automation provides consistency, proper speed. Primary cause - Liquid on parts, inadequate vapor dry phase. Solution - Automation for reliable timing. Primary cause - Disturbances in vaporlair interface caused by currents from heating, air conditioning, fans from refrigeration units or lip vent exhausts. Solution - Equipment covers, draft-free environment. Primary cause - Displacement of vaporlair interface by too rapid movement of parts Solution - Slower or regulated entrancelexit speed. I ~~ ~~ Primary cause - Failure of cooling coils, vapors escape before heat is shuldown. Solution - Redundant coolina coil temderaturelflow measurement in equipment. Primary cause - Acid breakdown contaminates entire sump volume producing hazardous waste. Solution - Backup safety features to reduce chance of acid formation, periodic check of stabilizers in chemistry. Primary cause - Routine maintenance cycles. Solutions - Check all joints for tightness, use appropriate gasket material, look for easily accessible maintenance features in equipment. Branson Ultrasonics can help you with emission con- For the self-audit Emissions Checklist, a Solvent Effitrol techniques. We are prepared to work with you to ciency Package of equipment literature, or for a Cleanreduce solvent emissions through operation awareness, ing Applications Laboratory form, call us at process control, system automation, or equipment 203-796-0349 or write to Branson Ultrasonics Corpospecifications. We can supply you with a self-audit to ration, Solvent Efficiency Information, 41 Eagle Road, check operations in your own plant for solvent emis- Danbury, Ct. 06813-1961. sions. Information on the effectiveness of solvent alternatives on specific applications also is available from our Cleaning Applications Laboratory. BRANSON ULTRASONICS CORPORATION 41 Eagle Road, Danbury, CT 06813-1961 (203) 796-0400 BRANSON The Clean Idea eode @ Branson Ultrasonics Corporation. 1989 S-996 Printed in the USA, 6/89